the absorption and float voltage setting is retrieved from connected
Victron Ve.Direct MPPTs using the HEX protocol. the values are
displayed in the live view, published to MQTT, and added to Home
Assistent auto-discovery.
only on ESP32-S3-USB. this fiddles with the available hardware UARTs to
make it possible to use a third Victron MPPT. if three MPPTs are defined
int the pin mapping, you will not be able to use the SmartShunt and JK
BMS battery interfaces.
note that using a second MPPT will also conflict with the SDM power
meter, and that conflict is not detected, yet.
* process "IL", "AR" and "MON"
* discard "BMV" and (unsolicited) History Data
* simplify isDataValid()
* veMpptStruct, veStruct: new, verbose variable names, including units,
and replace floats (save values with original integer precision)
* comment on rollover situation in isDataValid()
* show charge controller temperature in live view
* send hex requests right after decoding a frame. this seems to have the
best chance of getting an answer to all requests.
* deem 0xFFFFFFFF value of network total DC power as invalid indicator.
neither network state, nor network info, nor network mode seem to
indicate that the charge controller is part of a VE.Smart network. for
that reason, we revert to always querying the network total DC power
value, but testing it for max(uin32_t) value, which seems to indicate
that the charge controller is not part of a VE.Smart network.
* improve (verbose) logging, e.g., use _logId, and print names of
response codes and known registers, always print error messages,
add additional tests to prevent overly verbose messages.
* move hex protocol definitions to VeDirectData.h header
and use enum classes
* define register addresses in enum class
* move values retrieved through hex protocol into main MPPT data struct
* do not send HEX requests if the serial interface cannot send data
* detect whether smart battery sense temperature is available
* web app: make all VE.Direct sub-cards iterable. this makes addind more
values much simpler and saves a bunch of code in the web app.
* make VeDirectFrameHandler state a type-safe enum class
* unindent MPPT controller loop()
* whitespace cleanup
queue every text event until the frame was checked by it checksum. then
process the data directly into the buffer struct. do not clear the
buffer struct, so it will always include the most recent value of a
particular data point.
this change utilizes some of the features from library "frozen", which
was included upstream for the grid profile parser. to improve code
maintainability, a couple of std::maps mapping strings to values or the
other way around were introduced in OpenDTU-OnBattery-specific code at
the expense of some flash and computing overhead.
library "frozen" offers constexpr versions of map and string, which
saves initialization code and offers slightly faster lookups. this
brings the binary size down by ~25kB and should provide a small
performance improvement at runtime.
* introduce VictronMpptClass
this solves a design issue where the loop() method of a static instance
of VeDirectMpptController, which is part of library code, is called as
part of the main loop() implementation. that is a problem because the
call to this loop() must be handled differently from all other calls:
the lib does not know whether or not the feature is enabled at all.
also, the instance would not be initialized when enabling the feature
during normal operation. that would even lead to a nullptr exception
since the pointer to the serial implementation is still uninitialized.
this new intermediate class is implemented with the support for multiple
Victron charge controllers in mind. adding support for more charge
controllers should be more viable than ever.
fixes#481.
related to #397#129.
* VE.Direct: move get.*AsString methods to respective structs
those structs, which hold the data to be translated into strings, know
best how to translate them. this change also simplifies access to those
translation, as no parameter must be handed to the respective methods:
they now act upon the data of the instance they are called for. adds
constness to those methods.
* VE.Direct: simplify and clean up get.*AsString methods
use a map, which is much easier to maintain and which reads much easier.
move the strings to flash memory to save RAM.
* DPL: use VictronMpptClass::getPowerOutputWatts method
remove redundant calculation of output power from DPL. consider
separation of concern: VictronMpptClass will provide the total solar
output power. the DPL shall not concern itself about how that value is
calculated and it certainly should be unaware about how many MPPT charge
controllers there actually are.
* VE.Direct: avoid shadowing struct member "P"
P was part of the base struct for both MPPT and SmartShunt controller.
however, P was also part of the SmartShunt controller data struct,
shadowing the member in the base struct.
since P has slightly different meaning in MPPT versus SmartShunt, and
since P is calculated for MPPT controllers but read from SmartShunts, P
now lives in both derived structs, but not in the base struct.
* VE.Direct: isDataValid(): avoid copying data structs
pass a const reference to the base class implementation of isDataValid()
rather than a copy of the whole struct.
* VE.Direct: unify logging of text events
* VE.Direct: stop processing text event if handled by base
in case the base class processed a text event, do not try to match it
against values that are only valid in the derived class -- none will
match.
* VE.Direct MPPT: manage data in a shared_ptr
instead of handing out a reference to a struct which is part of a class
instance that may disappear, e.g., on a config change, we now manage the
lifetime of said data structure using a shared_ptr and hand out copies
of that shared_ptr. this makes sure that users have a valid copy of the
data as long as they hold the shared_ptr.
* VE.Direct MPPT: implement getDataAgeMillis()
this works even if millis() wraps around.
* VE.Direct: process frame end event only for valid frames
save a parameters, save a level of indention, save a function call for
invalid frames.
* Move Mppt logic to subclass
* Added Definitions for Shunts and restructering
* First integration of SmartShunt data into Web Interface
* Code cleanup
* VE.Direct: whitespace cleanup
* VE.Direct: manage HardwareSerial in unique_ptr
* VE.Direct: _efficiency is only needed by MPPT
* VE.Direct: keep as many members private as possible
* VE.Direct: use int8_t for pins (as before)
* VictronSmartShunt: _verboseLogging is not used
* VE.Direct: OR (off reason) is MPPT specific
it also applies to Phoenix inverters and Smart BuckBoost, but since
there is no support for those, the code is moved to the MPPT controller.
* Added Shunt alarms to liveview
Changed from double to int for several readings
* Update build.yml to allow manual builds
---------
Co-authored-by: Philipp Sandhaus <philipp.sandhaus@cewe.de>
Co-authored-by: Bernhard Kirchen <schlimmchen@posteo.net>
* VE.Direct: reset state machine on timeout
there will never be a large gap between two bytes of the same frame.
if such a large gap is observed, reset the state machine so it tries
to decode a new frame once more data arrives.
this is helpful in case of corrupted data that prevents the state
machine of transitioning to the final state even though the VE.Direct
data producer is done sending bytes that belong to the same frame.
* VE.Direct: print problems to MessageOutput
this includes the web console in particular, where many users have
access to while the serial console is not attached or monitored.
* VE.Direct: collect serial input into buffer and print
should help debug issues for users.
* VE.Direct: implement and use verbose logging switch
* VE.Direct: remove polling interval
the polling interval was meant to limit the amount of MQTT updates.
however, that is already controlled by the global MQTT publish interval.
the removed interval was instead used to limit polling of the VE.Direct
UART for incoming data.
the Victron device sends data unsolicited. the VeDirectFrameHandler does
not implement any polling mechanism. no data is ever sent to the Victron
device.
what the removed polling interval did was cause a buffer overrun of the
HardwareSerial class, since the incoming data was not processed in time.
so every five seconds, we read a whole valid VE.Direct frame, plus some
old data, which was not a whole frame, leading to VE.Direct error
messages to pop up.
with the polling interval removed, no framing errors are reported, and
instead we gain new data from the charge controller approximately ever
two seconds -- for free.
* VE.Direct: change texts to correct VE.Direct capital letters
* VE.Direct: improve "UpdatesOnly" switch labels
especially since the publish interval setting is gone, the label makes
it hard to comprehend what the switch does. update the texts to better
explain what the switch is used for.
use the same text on the VE.Direct info view.
* VE.Direct: use StatusBadge on info view
there were custom badges to indicate the VE.Direct settings. replace
those by the common StatusBadge to make then look the same as the other
badged on the info views.
* add calculated values to VE.Direct data
solar current, battery output power, and the charger's efficiency can be
calculated from the values reported by the charger. the efficiency must
be taken with a grain of salt. it seems that the solar power value and
the battery output voltage/current are not always in sync. for that
reason a moving average is used to smooth out the calculated efficiency
value.
* show calculated VE.Direct values in web live view
order the values and translations similarly for the input and output,
starting with power at the top, then voltage, then current as the last
of these three.
* VE.Direct live view: use 'd' as unit for days
'd' is the SI unit symbol for days and does not need translation, which
is desirable as units are not translated throughout the project.
* refactor VE.Direct live view
* move Dynamic Power Limiter data into its own type.
* split VE.Direct data into three types: "device", "input", and
"output". hence all input and output values are now ValueObject, which
allows to iterate over them using a loop without typing issues.
* generate the tables with input and output values using a loop, rather
than defining each row individually.
* localize numbers using $n (vue method), which fixes switching the
number format (dot vs. comma) when switching the language.
* use no decimal point for power values (they are integers), three
decimal points for kWh values (charger only reports two decimal
places, but three are easier to read since the unit is *kilo* Wh), one
decimal point for the efficiency, and two for voltage and current.
* update language tokens to avoid mapping JSON keys to language keys
(use the JSON keys to access the language tokens).
* re-structure language tokes so the brief keys took over from
VeDirectFrameHandler always make sense (nest into "input" and
"output").
* order values similarly from top to bottom: power, then voltage, then
current. this is following the order of the inverters' details.
* group values by type/unit (yield and max. power) and order them
"newest" to "oldest" from top to bottom.
* increase the DynamicJsonDocument as it was too small to hold the newly
added data.
* update webapp_dist to include VE.Direct live view refactoring