# MQTT Topics
|
|
|
|
The base topic, as configured in the web GUI is prepended to all follwing topics.
|
|
|
|
## General topics
|
|
|
|
| Topic | R / W | Description | Value / Unit |
|
|
| --------------------------------------- | ----- | ---------------------------------------------------- | -------------------------- |
|
|
| dtu/ip | R | IP address of OpenDTU | IP address |
|
|
| dtu/hostname | R | Current hostname of the dtu (as set in web GUI) | |
|
|
| dtu/rssi | R | WiFi network quality | db value |
|
|
| dtu/status | R | Indicates whether OpenDTU network is reachable | online / offline |
|
|
| dtu/uptime | R | Time in seconds since startup | seconds |
|
|
|
|
## Inverter specific topics
|
|
|
|
serial will be replaced with the serial number of the inverter.
|
|
|
|
| Topic | R / W | Description | Value / Unit |
|
|
| --------------------------------------- | ----- | ---------------------------------------------------- | -------------------------- |
|
|
| [serial]/name | R | Name of the inverter as configured in web GUI | |
|
|
| [serial]/device/bootloaderversion | R | Bootloader version of the inverter | |
|
|
| [serial]/device/fwbuildversion | R | Firmware version of the inverter | |
|
|
| [serial]/device/fwbuilddatetime | R | Build date / time of inverter firmware | |
|
|
| [serial]/device/hwpartnumber | R | Hardware part number of the inverter | |
|
|
| [serial]/device/hwversion | R | Hardware version of the inverter | |
|
|
|
|
### AC channel / global specific topics
|
|
|
|
| Topic | R / W | Description | Value / Unit |
|
|
| --------------------------------------- | ----- | ---------------------------------------------------- | -------------------------- |
|
|
| [serial]/0/current | R | AC current in ampere | Ampere (A) |
|
|
| [serial]/0/efficiency | R | Ratio AC Power over DC Power in percent | % |
|
|
| [serial]/0/frequency | R | AC frequency in hertz | Hertz (Hz) |
|
|
| [serial]/0/power | R | AC active power in watts | Watt (W) |
|
|
| [serial]/0/powerdc | R | DC power in watts | Watt (W) |
|
|
| [serial]/0/powerfactor | R | Power factor in percent | % |
|
|
| [serial]/0/reactivepower | R | AC reactive power in VAr | VAr |
|
|
| [serial]/0/temperature | R | Temperature of inverter in degree celsius | Degree Celsius (°C) |
|
|
| [serial]/0/voltage | R | AC voltage in volt | Volt (V) |
|
|
| [serial]/0/yieldday | R | Energy converted to AC per day in watt hours | Watt hours (Wh) |
|
|
| [serial]/0/yieldtotal | R | Energy converted to AC since reset watt hours | Kilo watt hours (kWh) |
|
|
|
|
### DC input channel topics
|
|
|
|
[1-4] represents the different inputs. The amount depends on the inverter model.
|
|
|
|
| Topic | R / W | Description | Value / Unit |
|
|
| --------------------------------------- | ----- | ---------------------------------------------------- | -------------------------- |
|
|
| [serial]/[1-4]/current | R | DC current of specific input in ampere | Ampere (A) |
|
|
| [serial]/[1-4]/irradiation | R | Ratio DC Power over set maximum power (in web GUI) | % |
|
|
| [serial]/[1-4]/power | R | DC power of specific input in watt | Watt (W) |
|
|
| [serial]/[1-4]/voltage | R | DC voltage of specific input in volt | Volt (V) |
|
|
| [serial]/[1-4]/yieldday | R | Energy converted to AC per day on specific input | Watt hours (Wh) |
|
|
| [serial]/[1-4]/yieldtotal | R | Energy converted to AC since reset on specific input | Kilo watt hours (kWh) |
|
|
|
|
### Inverter limit specific topics
|
|
|
|
cmd topics are used to set values. Status topics are updated from values set in the inverter.
|
|
|
|
| Topic | R / W | Description | Value / Unit |
|
|
| ----------------------------------------- | ----- | ---------------------------------------------------- | -------------------------- |
|
|
| [serial]/status/limit_relative | R | Current applied production limit of the inverter | % of total possible output |
|
|
| [serial]/status/limit_absolute | R | Current applied production limit of the inverter | Watt (W) |
|
|
| [serial]/status/reachable | R | Indicates whether the inverter is reachable | 0 or 1 |
|
|
| [serial]/status/producing | R | Indicates whether the inverter is producing AC power | 0 or 1 |
|
|
| [serial]/cmd/limit_persistent_relative | W | Set the inverter limit as a percentage of total production capability. The value will survive the night without power. The updated value will show up in the web GUI and limit_relative topic immediatly. | % |
|
|
| [serial]/cmd/limit_persistent_absolute | W | Set the inverter limit as a absolute value. The value will survive the night without power. The updated value will show up in the web GUI and limit_relative topic after around 4 minutes. | Watt (W) |
|
|
| [serial]/cmd/limit_nonpersistent_relative | W | Set the inverter limit as a percentage of total production capability. The value will reset to the last persistent value at night without power. The updated value will show up in the web GUI and limit_relative topic immediatly. | % |
|
|
| [serial]/cmd/limit_nonpersistent_absolute | W | Set the inverter limit as a absolute value. The value will reset to the last persistent value at night without power. The updated value will show up in the web GUI and limit_relative topic after around 4 minutes. | Watt (W) |
|
|
| [serial]/cmd/power | W | Turn the inverter on (1) or off (0) | 0 or 1 |
|
|
| [serial]/cmd/restart | W | Restarts the inverters (also resets YieldDay) | 1 |
|