Commit Graph

1738 Commits

Author SHA1 Message Date
Bernhard Kirchen
f0def2ae89
Selective verbosity (#318)
* DPL: implement verbose logging switch

* MQTT: implement verbose logging switch

* power meter: implement verbose logging switch

* Hoymiles lib: implement verbose logging switch

* cpp linting: "final" makes "virtual" and "override" redundant

... however, using only "final" is not as verbose.
2023-07-18 09:57:03 +02:00
Phantomias2006
a7da000345
Feature: set Huawei offline parameters via MQTT (#315)
* Add Huawei offline parameters via MQTT

* Update README.md

Correction of the docu

* Update MQTT_Topics.md

Correction of the docu
2023-07-18 09:52:31 +02:00
Martin
0dd1566dc6
Fix: WebApp Live-View: adjust window-title and header (#317)
adjust window-title and header from OpenDTU to OpenDTU-onBattery
Additionally change orientation of battery symbol to vertically centered
(looks nicer)

Signed-off-by: Martin Dummer <martin.dummer@gmx.net>
2023-07-18 09:51:59 +02:00
Martin
c393e52185
Feature: add Home Assistant MQTT discovery for Pylontech battery (#314)
When OpenDTU has a Pylontech CAN Bus Battery connected and enabled, this
patch adds the discovery routine for Home Assistant

Signed-off-by: Martin Dummer <martin.dummer@gmx.net>
2023-07-17 09:50:58 +02:00
Bernhard Kirchen
cbc99d715f
DPL: increase backoff while inverter is kept shut down (#310)
if the new calculated power limit is below the minimum power limit
setting, the inverter is shut down. the shutdown() function is called
every time this condition is detected, which is also true if the
inverter is kept shut down for longer. that happens while the battery
is charging in particular (solar passthrough off). there are other
cases.

in such cases we still want to get into the DPL status "stable". to be
able to determine this stable state, we must know if the call to
shutdown did actually initiate a shutdown or if the inverter is already
shut down.

we then can forward this "changed" or "not changed" info up the call
chain, where the loop() will know that the system is actually stable.
2023-07-17 09:40:18 +02:00
helgeerbe
f68f68be77 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-07-13 12:19:21 +02:00
Thomas Basler
3b02ffe7a8 webapp: Update dependencies 2023-07-12 18:40:23 +02:00
Thomas Basler
cf91839838 Upgrade espMqttClient from 1.4.3 to 1.4.4 2023-07-12 18:38:35 +02:00
helgeerbe
633ef88296 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-07-12 13:45:19 +02:00
Bernhard Kirchen
f3297930b5
DPL: account for solar passthrough losses (#307)
* fix another fixable "passtrough" typo

the typo in the config's identifier is not changed to preserve
compatibility while not spending the effort to migrate the setting.

* webapp language: prefer SoC over SOC

* DPL: implement solar passthrough loss factor

in (full) solar passthrough mode, the inverter output power is coupled
to the charge controler output power. the inverter efficiency is already
accounted for. however, the battery might still be slowly discharged for
two reasons: (1) line losses are not accounted for and (2) the inverter
outputs a little bit more than permitted by the power limit.

this is undesirable since the battery is significantly drained if solar
passthrough is active for a longer period of time. also, when using full
solar passthrough and a battery communication interface, the SoC will
slowly degrade to a value below the threshold value for full solar
passthrough. this makes the system switch from charging the battery
(potentially rapidly) to discharging the battery slowly. this switch
might happen in rather fast succession. that's effectively
trickle-charging the battery.

instead, this new factor helps to account for line losses between the
solar charge controller and the inverter, such that the battery is
actually not involved in solar passthrough. the value can be increased
until it is observed that the battery is not discharging when solar
passthrough is active.
2023-07-12 13:20:37 +02:00
MalteSchm
95d7ac7adf
Disable debug mode, increasing power threshold for active channel detection (#301) 2023-07-12 13:19:24 +02:00
Thomas Basler
0d07b1aa4a webapp: add app.js.gz 2023-07-10 20:45:51 +02:00
Thomas Basler
56e2b462fb Update espressif32 from 6.3.1 to 6.3.2 2023-07-10 20:26:07 +02:00
Thomas Basler
b8c75b02a0 Merge branch 'pr1003' into dev 2023-07-10 19:11:54 +02:00
Stephan
1871a9a692 use FSPI for esp32-c3 and revise device profiles 2023-07-10 19:04:13 +02:00
Thomas Basler
99b316587e webapp: Update dependencies 2023-07-10 18:34:55 +02:00
Thomas Basler
fe3d6588bc Feature: Turn off LED 1 if no inverters are enabled for polling
This means that e.g. at night, when polling at night is disabled, LED 1 will be turned off now.
2023-07-10 18:31:04 +02:00
Thomas Basler
0ffbba0cf5 Fix: Allow sending of ChannelChangeCommand even if EnableCommands is disabled
This is required to successfull move the inverter to another frequency and then polling it. Without this command its not even possible to poll a inverter.

Fixes #1127
2023-07-10 18:30:59 +02:00
helgeerbe
1d559c1c40 add webapp 2023-07-09 17:11:09 +02:00
MalteSchm
475aab1e9a
floating point input (#302) 2023-07-09 17:09:33 +02:00
Martin
cdf5c85510
fix: Home Assistant MQTT-Auto-Discovery with VE.Direct (#297)
In Home Assistant, when Home Assistant MQTT-Auto-Discovery is active,
almost all Sensors of the auto-discovered Victron device in Home
Assistant become "unavailable" after a short time - except those
Sensors with frequent changes like battery voltage or panel voltage.

This patch introduces regular mqtt updates for all VE.Direct sensors
when MQTT-Auto-Discovery is enabled.

Signed-off-by: Martin Dummer <martin.dummer@gmx.net>
2023-07-09 17:08:50 +02:00
Bernhard Kirchen
23ff4ef22a
DPL: do not use nullptr when printing debug messages (#303) 2023-07-09 16:42:50 +02:00
helgeerbe
2a858e096b fix: typo 2023-07-07 17:22:04 +02:00
helgeerbe
3fb062b5cc fix: typo 2023-07-07 17:08:51 +02:00
helgeerbe
ffa9be0835 fix: #294 Passthrough Spelling 2023-07-07 17:05:44 +02:00
helgeerbe
344498d440 fix: linting error 2023-07-04 14:55:55 +02:00
helgeerbe
d3adc65d11 add webapp 2023-07-04 12:07:50 +02:00
Bernhard Kirchen
107182f948
DPL: check more requirements and fix backoff initialization (#290)
* DPL: wait for valid time information

we know that the Hoymiles library refuses to send any message to any
inverter until the system has valid time information. until then we can
do nothing, not even shutdown the inverter.

* DPL: wait for device info to be ready

a calculated power limit will always be limited to the reported
device's max power. that upper limit is only known after the first
DevInfoSimpleCommand succeeded. wait for that information to be
available.

* DPL: fix initial calculcation backoff

if the calculation backoff is initialized to zero, the backoff will be
doubled to zero until a new, different power limit was calculated for
the first time. this lead to the DPL recalculating a power limit
hundreds of times without a backoff after startup.
2023-07-04 12:05:10 +02:00
Bernhard Kirchen
e457ab73f9
Fix vedirect polling (#291)
* VE.Direct: remove polling interval

the polling interval was meant to limit the amount of MQTT updates.
however, that is already controlled by the global MQTT publish interval.
the removed interval was instead used to limit polling of the VE.Direct
UART for incoming data.

the Victron device sends data unsolicited. the VeDirectFrameHandler does
not implement any polling mechanism. no data is ever sent to the Victron
device.

what the removed polling interval did was cause a buffer overrun of the
HardwareSerial class, since the incoming data was not processed in time.
so every five seconds, we read a whole valid VE.Direct frame, plus some
old data, which was not a whole frame, leading to VE.Direct error
messages to pop up.

with the polling interval removed, no framing errors are reported, and
instead we gain new data from the charge controller approximately ever
two seconds -- for free.

* VE.Direct: change texts to correct VE.Direct capital letters

* VE.Direct: improve "UpdatesOnly" switch labels

especially since the publish interval setting is gone, the label makes
it hard to comprehend what the switch does. update the texts to better
explain what the switch is used for.

use the same text on the VE.Direct info view.

* VE.Direct: use StatusBadge on info view

there were custom badges to indicate the VE.Direct settings. replace
those by the common StatusBadge to make then look the same as the other
badged on the info views.
2023-07-04 12:04:38 +02:00
helgeerbe
006f63ed02 feature: add digest auth on power meter
Power Meter -> HTTP(S) + Jason configuration allows now basic and digest authentication (all Shelly Gen2 devices)
2023-07-04 11:54:46 +02:00
helgeerbe
9a4eb75160 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-07-02 14:32:12 +02:00
helgeerbe
1f39ed7b9b Merge branch 'pr/MalteSchm/288' into development 2023-07-02 14:28:51 +02:00
helgeerbe
afd8790c3c Merge branch 'pr/schlimmchen/287' into development 2023-07-02 14:20:25 +02:00
Bernhard Kirchen
99876d7c6b
DPL: fix the configured upper limit not being respected (#286)
the requested newPowerLimit was indeed limited to the configured maximum
inverter output and the result was stored in effPowerLimit. later,
however, effPowerLimit must be scaled up (if necessary), not
newPowerLimit. the latter variable is not respecting the configured
maximum inverter output.
2023-07-02 14:11:44 +02:00
Bernhard Kirchen
97f58eeba7
explain DPL modes set through MQTT in more detail (#282)
* explain DPL modes set through MQTT in more detail

* docs: DPL mode change through MQTT does not enable DPL
2023-07-02 14:11:23 +02:00
Bernhard Kirchen
097d464bbb
DPL: use vedirect isdatavalid (#283)
* DPL: use VeDirect.isDataValid()

in case the communication to the Victron charger is disrupted, the
respective values in VeDirect.veFrame are not invalidated such that we
would notice a problem. instead, isDataValid() should be used to make
sure that the Victron charger is actually alive and that we can trust to
use the reported values.

* DPL: simplify canUseDirectSolarPower return statement
2023-07-02 14:10:47 +02:00
MalteSchm
e279ce08c4 Dynamic power control and more power control modes on the Huawei PSU 2023-07-01 12:37:55 +02:00
Bernhard Kirchen
9aeb1583b5 DPL: consider the system stable when reusing the old limit
a new status is needed to communicate that no update was sent to the
inverter because its power limit is still valid. in this case,
calculating a new power limit is delayed by an exponentially increasing
backoff. the maximum backoff time is ~1s, which is still plenty fast.

the backoff is actually necessary for another reason: at least
currently, a lot of debug messages are printed to the console. printing
all that information in every DPL loop() is too much.
2023-06-30 21:00:51 +02:00
Bernhard Kirchen
461fce8ff4 DPL: do not repeat being disabled 2023-06-30 21:00:51 +02:00
Bernhard Kirchen
9bab740c43 DPL: replace _plState enum with a simple boolean switch 2023-06-30 21:00:51 +02:00
Bernhard Kirchen
b2d58af5e8 DPL: separate unconditional solar passthrough mode
the unconditional solar passthrough mode, configured using MQTT, works
differently than the normal mode of operation. it is also independent
from the power meter reading. if this mode is active, a shortcut is
taken to a function that implements the actions for this mode. this is
convenient since we don't have to consider special cases in the code
that handles normal mode of operation.
2023-06-30 21:00:51 +02:00
Bernhard Kirchen
71079fa0cc DPL: work on internal copy of pointer to inverter
the DPL already took care to shut down the inverter if anything fishy
was going on, mainly to make sure that the battery is not drained.
however, some cases were missed:

* if the configuration changed such that another inverter is now
  targeted, the one the DPL controlled previously was not shut down.
* if the configuration changed such that another inverter (different
  serial number) was configured at the same index, the previous one
  was not shut down.

this change corrects these problems by making the DPL keep a copy of the
shared_ptr to the inverter. the shared_ptr is only released once the DPL
shut the respective inverter down.
2023-06-30 20:04:39 +02:00
Bernhard Kirchen
2970e84193 DPL requirement: disabled inverter commands
if the inverter is not configured to be sent commands to, the DPL is
unable to control it, so the loop is aborted.
2023-06-30 20:04:39 +02:00
Bernhard Kirchen
18b1076660 DPL: improve responsiveness
this implementation checks all requirements for a new power limit to be
calculated, one after the other. if any requirement is not met, a
respective status is announced.

status messages are communicated on the (serial) console. these can also
be displayed easily on the web app in the future. the status texts
explain clearly what the DPL is currently doing, which aids
understanding how the DPL works. the status is only announced if it
changes, or after a fixed interval.

as each requirement is checked individually, the code readability is
improved as well. previously, all the respective conditions had to be
checked as well, but the statements were more complex.

the DPL loop is now executed with high frequency, i.e., it does not wait
for a fixed timespan to pass before checking requirements. it always
aborts on the first unmet requirement. this should improve responsiveness,
as the DPL checks all requirements more often.

the DPL now waits for all power commands and power limit updates to
complete. when that is the case, a settling time elapses. after the
settling phase, the DPL waits for a new update from the inverter and
from the power meter. now it can be assumed that the values are in sync.
it then makes sense to calculate a new power limit immediately, which
the DPL then does.
2023-06-30 20:04:39 +02:00
Bernhard Kirchen
0b0bcf1dfb fix typo: getLastRequestedPowe*w*rLimit() 2023-06-30 20:04:39 +02:00
Bernhard Kirchen
fd208cf6bb DPL: remove unused member variables 2023-06-30 20:03:21 +02:00
Bernhard Kirchen
8b23324693 ensure only one PowerCommand and ActivePowerCommand is queued
neither a PowerCommand nor an ActivePowerCommand shall be enqueued if
another one is already pending.
2023-06-30 20:03:21 +02:00
Martin
8433820529
Fix typo in error messages (#280)
Signed-off-by: Martin Dummer <martin.dummer@gmx.net>
2023-06-29 13:06:28 +02:00
helgeerbe
0caffe9411 fix: Allow use GPIO0 as onBattery pins 2023-06-29 13:04:35 +02:00
helgeerbe
6ffb5bb897 fix: undefined pin is shown as -1 instead of 255
change pin type for onBattery pins from uint8_t to int8_t.  Negativ pin values means not defined
2023-06-29 13:02:38 +02:00