on power meter issues (usually a timeout), keep the inverter enabled and
make it produce the configured base load limit if the battery can be
discharged. that should be okay since the base load config value is
expected to be small and a little less than the actual household base
load, i.e., if this amount of power is produced, the household will
consume it in any case and no energy is fed into the grid.
in your pin_mapping.json, add a powermeter object like this:
[
{
"name": "My Board",
...
"powermeter": {
"rx": <num>,
"tx": <num>,
"dere": <num>
},
...
}
]
the SML power meter requires the rx pin to be set. the SDM power meter
requires the rx and tx pins are set. the "dere" pin pin is optional and
if set, this pin controls the driver enable and receiver enable pins of
the RS485 transceiver. the SDM library handles this pin.
closes#771.
the SDM power meter (among others) writes the power consumption of three
phases in multiple steps. this change helps to prevent getTotalPower()
reading intermediate values, e.g., reading a new value for phase 1 but
old values for phase 2 and 3 since phase 2 is currently read.
cache the values, and write them all at once, protected by a mutex,
later.
closes#732.
* Optimize Sun data calculation
* Remove not required enum
* Split config struct into different sub structs
* Feature: Allow configuration of LWT QoS
* Made resetreason methods static
* Feature: Implement offset cache for "YieldDay"
Thanks to @broth-itk for the idea!
Fix: #1258#1397
* Add Esp32-Stick-PoE-A
* remove broken LilyGO_T_ETH_POE config, use device profile instead
* Feature: High resolution Icon and PWA (Progressive Web App) functionality
Fix: #1289
* webapp: Update dependencies
* Initialize TaskScheduler
* Migrate SunPosition to TaskScheduler
* Migrate Datastore to TaskScheduler
* Migrate MqttHandleInverterTotal to TaskSchedule
* Migrate MqttHandleHass to TaskScheduler
* Migrate MqttHandleDtu to TaskScheduler
* Migrate MqttHandleInverter to TaskScheduler
* Migrate LedSingle to TaskScheduler
* Migrate NetworkSettings to TaskScheduler
* Migrate InverterSettings to TaskScheduler
* Migrate MessageOutput to TaskScheduler
* Migrate Display_Graphic to TaskScheduler
* Migrate WebApi to TaskScheduler
* Split InverterSettings into multiple tasks
* Calculate SunPosition only every 5 seconds
* Split LedSingle into multiple tasks
* Upgrade espMqttClient from 1.4.5 to 1.5.0
* Doc: Correct amount of MPP-Tracker
* Added HMT-1600-4T and HMT-1800-4T to DevInfoParser
Fix#1524
* Adjusted inverter names for HMS-1600/1800/2000-4T
* Add channel count to description of detected inverter type (DevInfoParser)
* Adjust device web api endpoint for dynamic led count
* Feature: Added ability to change the brightness of the LEDs
Based on the idea of @moritzlerch with several modifications like pwmTable and structure
* webapp: Update dependencies
* Update olikraus/U8g2 from 2.35.7 to 2.35.8
* Remove not required onWebsocketEvent
* Remove code nesting
* Introduce several const statements
* Remove not required AsyncEventSource
* Doc: Added byte specification to each command
* Feature: Added basic Grid Profile parser which shows the used profile and version
Other values are still outstanding.
* Optimize AlarmLogParser to save memory
* Add libfrozen to project to create constexpr maps
* Feature: First version of GridProfile Parser which shows all values contained in the profile.
* webapp: Update dependencies
* Apply better variable names
* Remove not required casts
* Add additional compiler flags to prevent errors
* Add const statement to several variables
* Replace NULL by nullptr
* Update bblanchon/ArduinoJson from 6.21.3 to 6.21.4
* Add const keyword to method parameters
* Add const keyword to methods
* Use references instead of pointers whenver possible
* Adjust member variable names in MqttSettings
* Adjust member variable names in NetworkSettings
* webapp: Update timezone database to latest version
* webapp: Beautify and unify form footers
* Feature: Allow setting of an inverter limit of 0% and 0W
Thanks to @madmartin in #1270
* Feature: Allow links in device profiles
These links will be shown on the hardware settings page.
* Doc: Added hint regarding HMS-xxxx-xT-NA inverters
* Feature: Added DeviceProfile for CASmo-DTU
Based on #1565
* Upgrade actions/upload-artifact from v3 to v4
* Upgrade actions/download-artifact from v3 to v4
* webapp: add app.js.gz
* Gridprofileparser: Added latest known values
Thanks to @stefan123t and @noone2k
* webapp: Fix lint errors
* Feature: Add DTU to Home Assistant Auto Discovery
This is based on PR 1365 from @CFenner with several fixes and optimizations
* Fix: Remove debug output as it floods the console
* Fix: Gridprofileparser: Add additional error handling if profile is unknown
* webapp: add app.js.gz
* Fix: Offset cache for "YieldDay" did not work correctly
* webapp: update dependencies
* webapp: add app.js.gz
* Fix: yarn.lock was outdated
* Fix: yarn build error
* Fix: Reset Yield day correction in combination with Zero Yield Day on Midnight lead to wrong values.
* Fix: Allow negative values in GridProfileParser
* Correct variable name
* Fix#1579: Static IP in Ethernet mode did not work correctly
* Feature: Added diagram to display
This is based on the idea of @Henrik-Ingenieur and was discussed in #1504
* webapp: update dependencies
* webapp: add app.js.gz
---------
Co-authored-by: Thomas Basler <thomas@familie-basler.net>
Co-authored-by: Pierre Kancir <pierre.kancir.emn@gmail.com>
* PowerMeter: gracefully handle non-float MQTT values
* PowerMeter: update _lastPowerMeterUpdate conservatively
update the timestampt only if the topic actually matched any
subscription and if the value could be parsed as a float.
* PowerMeter: unsubscribe before subscribing
* PowerMeter: organize subscriptions in a map
this allows for a slightly more elegant code and reduced amount of code
overall.
* PowerMeter: clean up header
* move private methods to private section of class declaration.
* remove unused member variable.
* DPL: implement verbose logging switch
* MQTT: implement verbose logging switch
* power meter: implement verbose logging switch
* Hoymiles lib: implement verbose logging switch
* cpp linting: "final" makes "virtual" and "override" redundant
... however, using only "final" is not as verbose.
In addition to the cyclic query of the power meters, they will be queried on demand when total power is requested and last update is older than 1 second.
* add support for energy & power readings on SML based power meters, taking OBIS 16.7.1 for power (using mod. SML Parser lib. by olliiiver)
* switched SML read to use software serial
* made total power meter response controled by meter source to obtain either the sum of phase powers or explicit total power provided by meter
* made mqtt subscriptions to power meter topics meter source dependend
* simplified SML read loop and OBIS handler registration, + minor refactoring
* minor cleanup/style changes and optim. PowerMeter
* fixed build, add SOURCE_SML == 4
* removed optional usage of HW serial for SML power meter
* switched to usage of _powerMeter1Power for SML power reading to allign better with existing code
---------
Co-authored-by: helgeerbe <helge@erbehome.de>