Commit Graph

1968 Commits

Author SHA1 Message Date
Bernhard Kirchen
6e78c5bd1c
Feature: JK BMS: export (more) data to live view and MQTT (#549)
* add more values to web app live view. this should add all interesting
  values for the web app live view. those include important values and
  values that change frequently.

* add more interesting JK BMS dummy messages: one has 0% SoC and an
  alarm (discharge undervoltage) set. the other has the undertemperature
  alarm set.

* add alarms and warnings to live view

* publish alarm and status bits through MQTT individually

* publish cell voltages to MQTT broker

* remove trailing spaces in BatteryStats class
2023-12-15 10:59:07 +01:00
helgeerbe
dd8446df0a Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-11-17 09:30:04 +01:00
Thomas Basler
859b902ef9 webapp: add app.js.gz 2023-11-16 18:15:45 +01:00
Thomas Basler
614c0a0990 webapp: Update dependencies 2023-11-16 18:13:46 +01:00
Thomas Basler
6f685a4ab5 Fix: Day period is only calculated once 2023-11-16 18:03:25 +01:00
helgeerbe
0085970567 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-11-16 09:20:08 +01:00
Thomas Basler
527c2eaf4a webapp: add app.js.gz 2023-11-15 18:00:43 +01:00
Thomas Basler
352fec539a Doc: Add hint regarding wiki 2023-11-15 17:58:43 +01:00
Thomas Basler
22da8ff4c7 Doc: Fix readme syntax errors 2023-11-15 17:03:12 +01:00
Thomas Basler
ac0655ea64 Doc: Add additional breaking changes 2023-11-15 16:47:04 +01:00
Thomas Basler
aea2afad29 webapp: Update dependencies 2023-11-15 16:45:10 +01:00
Thomas Basler
07e2c5998b Build webapp using nodejs v20 2023-11-15 16:40:04 +01:00
Thomas Basler
3d837bdd29 Upgrade actions/setup-node from v3 to v4 2023-11-15 16:39:09 +01:00
Thomas Basler
7b9ddb5033 Upgrade actions/checkout from v3 to v4 2023-11-15 16:38:30 +01:00
Thomas Basler
bd26d09564 Fix: build action fails due to ModuleNotFoundError: No module named 'pkg_resources':
Fix #1500
2023-11-15 16:36:46 +01:00
helgeerbe
8cccce5875 add weapp 2023-11-15 14:26:54 +01:00
helgeerbe
6f7470feb4 fix: ModuleNotFoundError: No module named 'pkg_resources': 2023-11-15 14:07:27 +01:00
helgeerbe
28f46471bf set unique name for test_build action 2023-11-15 13:59:22 +01:00
helgeerbe
a004e94e57 create test_build action 2023-11-15 13:59:09 +01:00
MalteSchm
3dceddfe49
Split Huawei setValue in private/public implementation. Prevent setting values when internal power control mode is enabled (#521) 2023-11-15 12:38:35 +01:00
helgeerbe
d4d42167ec Merge branch 'pr/philippsandhaus/510' into development 2023-11-15 12:33:50 +01:00
Al3x Zamponi
3af0437857
Update MqttHandlVedirectHass.cpp
Fix HASS unit
2023-11-13 17:12:19 +01:00
Thomas Basler
fa7641f715 Fix: Power not set to 0 when not reachable at EOD
If the inverter polling was disabled before it got unreachable the values where not set to zero
Fix: #1488
2023-11-09 22:30:35 +01:00
Thomas Basler
71d1b3b846 BREAKING CHANGE: Home Assistant Auto Discovery to new naming scheme
Please Upgrade to HASS 2023.8 or greater.
Thanks to @LennartF22 for the first implementation
2023-11-07 19:37:28 +01:00
Thomas Basler
17e92fc5eb Feature: Support HMT-1600/1800/2000-4T 2023-11-07 18:34:37 +01:00
Thomas Basler
2ae8ed5e18 Doc: Add class description for inverters 2023-11-05 13:44:08 +01:00
Thomas Basler
0a4945ae39 Adjusted inverter names 2023-11-05 13:43:48 +01:00
Thomas Basler
89b4b8ea85 Merge branch 'pr1441' into dev 2023-10-31 19:30:56 +01:00
CommanderRedYT
7c875187a8
Implemented mDNS 2023-10-30 20:53:45 +01:00
Thomas Basler
a068eb2586 Remove duplicated code 2023-10-30 20:42:56 +01:00
Thomas Basler
aba57e687a Set dnsServerStatus first to prevent running 2023-10-30 20:25:39 +01:00
Thomas Basler
6a64fe6e1a Fix #1456: Prevent white spaces in username field 2023-10-30 16:45:34 +01:00
Thomas Basler
7e7d372338 webapp: Update dependencies 2023-10-29 11:28:49 +01:00
helgeerbe
49a10305e2 fix: liveData is not updated
- due to roll back of upstream commit, duplicated code allocated json buffer twice
- enlarge json buffer to 4200
2023-10-24 15:25:31 +02:00
helgeerbe
9ca3655de6 add webapp 2023-10-23 13:32:12 +02:00
Bernhard Kirchen
254b95cb0f
Fix: replace links to upstream project where applicable (#514) 2023-10-23 13:24:05 +02:00
Bernhard Kirchen
0fa2745ace
Fix: VE.Direct refactor issues from #505 (#516)
* VE.Direct: return non-nullptr as a fallback

the changed return statement was supposed to return a shared_ptr to a
new and valid MPPT data struct as a fallback. however, it did return a
new shared_ptr that was initialized to nullptr.

* VE.Direct: make liveview total use total MPPT values

this change makes the call to VictronMppt.getData() obsolete, which in
turn will therefore not cause an error message on the console if
VE.Direct (MPPT) is not enabled. this change also takes care that once
multiple VE.Direct MPPT charge controllers are supported, the sums of
the respective total values are used in the web app totals.
2023-10-23 13:23:06 +02:00
Philipp Sandhaus
8ba9048f99
Show battery temperature when sensor is present (#511) 2023-10-23 13:22:10 +02:00
Al3x Zamponi
c5427dedce
Add calculated values to hass auto discovery (#509)
Add battery P and E as well as panel I to auto discovery values of HA
2023-10-23 13:18:24 +02:00
Thomas Basler
b477db7045 Fix #1440: Add CSS code to stop numbers changing the size of their container 2023-10-21 12:54:51 +02:00
Philipp Sandhaus
b159c31258 Display efficiency measuremnt for Huawei AC charger in % in web interface 2023-10-20 22:14:45 +02:00
helgeerbe
b833d5ab52 add webapp 2023-10-19 16:24:19 +02:00
Bernhard Kirchen
4d4aadf8de
Feature: AC charger: configurable CAN controller frequency (#500) 2023-10-19 16:16:01 +02:00
Bernhard Kirchen
d23b991f5c
VE.Direct: Fix design issues and prepare support for multiple instances (#505)
* introduce VictronMpptClass

this solves a design issue where the loop() method of a static instance
of VeDirectMpptController, which is part of library code, is called as
part of the main loop() implementation. that is a problem because the
call to this loop() must be handled differently from all other calls:
the lib does not know whether or not the feature is enabled at all.
also, the instance would not be initialized when enabling the feature
during normal operation. that would even lead to a nullptr exception
since the pointer to the serial implementation is still uninitialized.

this new intermediate class is implemented with the support for multiple
Victron charge controllers in mind. adding support for more charge
controllers should be more viable than ever.

fixes #481.

related to #397 #129.

* VE.Direct: move get.*AsString methods to respective structs

those structs, which hold the data to be translated into strings, know
best how to translate them. this change also simplifies access to those
translation, as no parameter must be handed to the respective methods:
they now act upon the data of the instance they are called for. adds
constness to those methods.

* VE.Direct: simplify and clean up get.*AsString methods

use a map, which is much easier to maintain and which reads much easier.
move the strings to flash memory to save RAM.

* DPL: use VictronMpptClass::getPowerOutputWatts method

remove redundant calculation of output power from DPL. consider
separation of concern: VictronMpptClass will provide the total solar
output power. the DPL shall not concern itself about how that value is
calculated and it certainly should be unaware about how many MPPT charge
controllers there actually are.

* VE.Direct: avoid shadowing struct member "P"

P was part of the base struct for both MPPT and SmartShunt controller.
however, P was also part of the SmartShunt controller data struct,
shadowing the member in the base struct.

since P has slightly different meaning in MPPT versus SmartShunt, and
since P is calculated for MPPT controllers but read from SmartShunts, P
now lives in both derived structs, but not in the base struct.

* VE.Direct: isDataValid(): avoid copying data structs

pass a const reference to the base class implementation of isDataValid()
rather than a copy of the whole struct.

* VE.Direct: unify logging of text events

* VE.Direct: stop processing text event if handled by base

in case the base class processed a text event, do not try to match it
against values that are only valid in the derived class -- none will
match.

* VE.Direct MPPT: manage data in a shared_ptr

instead of handing out a reference to a struct which is part of a class
instance that may disappear, e.g., on a config change, we now manage the
lifetime of said data structure using a shared_ptr and hand out copies
of that shared_ptr. this makes sure that users have a valid copy of the
data as long as they hold the shared_ptr.

* VE.Direct MPPT: implement getDataAgeMillis()

this works even if millis() wraps around.

* VE.Direct: process frame end event only for valid frames

save a parameters, save a level of indention, save a function call for
invalid frames.
2023-10-19 16:15:29 +02:00
Bernhard Kirchen
917242909b
Fix: PowerMeter: update _lastPowerMeterUpdate for SOURCE_SML (#506)
closes #498.
2023-10-19 16:14:36 +02:00
Thomas Basler
11d7b78d80 Apply automatic code formatting 2023-10-11 14:19:20 +02:00
Thomas Basler
97d481fa65 Merge branch 'pr1408' into dev 2023-10-11 14:16:23 +02:00
Thomas Basler
c25e93eb09 Merge branch 'pr1406' into dev 2023-10-11 13:40:05 +02:00
Thomas Basler
f1a8c2ea82 Feature: Added additional event log descriptions and implemented i18n 2023-10-11 13:22:42 +02:00
Thomas Basler
dc5b5e837f Rename "DTU command failed" to "Time calibration" as mentioned in #121 2023-10-10 16:23:11 +02:00