Commit Graph

2385 Commits

Author SHA1 Message Date
Bernhard Kirchen
4e36c8c9ea
Feature: battery interface: use HW serial 0 on ESP32-C3 or S3 (#933)
this allows to use two VE.Direct interfaces, as there is no conflict
regarding HW serial port 2 after making the battery interfaces use
serial port 0 on devices with USB CDC. on those chips HW serial 0 is
free to be used since serial messages are written through the USB
interface directly.
2024-04-29 20:43:35 +02:00
MalteSchm
64738a6246 Introducing defines for RX2/TX2 2024-04-25 22:54:12 +02:00
MalteSchm
f0df583c13
Feature: support for Huawei target power consumption 2024-04-24 20:26:56 +02:00
Bernhard Kirchen
74330a5617 Feature: restart unresponsive inverter
we found that the inverter sometimes stops responding to commands,
especially to the "start producing" command. we now count the number of
consecutive timeouts when trying to send a new limit or power state
commands. after two timeouts were recorded, every additional timeout
will send a restart command to the inverter.

as a last resort, if the counter keeps climbing, the DTU is restarted.

notice that this only targets unresponsive inverters which are
reachable. unreachable inverters are not restarted and do not cause a
DTU reboot. this is important for solar-driven inverters, which are
unreachable during the night. the DPL will not calculate a new limit and
hence the updateInverter() method will do nothing while the target
inverter is unreachable.

publish the timeout counter to MQTT for monitoring purposes.
2024-04-24 16:15:01 +02:00
Bernhard Kirchen
eb9bfd1ac6 Fix: DPL mode 2 for solar-powered inverters
for solar-powered inverters, the unconditional full solar-passthrough
implementation now sets the upper limit configured in the DPL settings.
2024-04-22 12:51:31 +02:00
Bernhard Kirchen
1d4bea24ff Fix: JK BMS: BMS name is second part of product ID 2024-04-18 16:36:11 +02:00
Bernhard Kirchen
4cd690de66 VE.Direct: publish data retrieved from HEX protocol 2024-04-18 13:06:37 +02:00
Bernhard Kirchen
abe01ae36f Feature: HTTP power meter: support changing sign 2024-04-18 12:10:29 +02:00
Bernhard Kirchen
ede1abb5e6 Feature: HTTP power meter: support mW/kW as units 2024-04-18 12:10:29 +02:00
Bernhard Kirchen
247cfe712e HTTP power meter: prevent out-of-bound array access 2024-04-18 12:10:29 +02:00
Bernhard Kirchen
e92701ccdf reuse power meter's HTTP config struct 2024-04-18 12:10:29 +02:00
Bernhard Kirchen
4bc4defe66 DPL: insist on power meter value more recent than inverter stats
avoid performing a calculation based on a (slightly) outdated power
meter reading, which was aquired just before the limit was actually
applied by the inverter, but which was received by OpenDTU-OnBattery
after the inverter stats.
2024-04-15 23:02:58 +02:00
Bernhard Kirchen
5fcf09d0a0 fix hysteresis hint texts 2024-04-15 23:02:58 +02:00
Bernhard Kirchen
52d7ac9581 Feature: DPL: support setups without power meter
without a power meter configured, the DPL now sets the base load as the
inverter limit if the battery charge allows it. it also takes
solar-passthrough into account, i.e., if the battery is in a charge
cycle but the solar output (Victron MPPT) is significant, the solar
power will be used up until the base load. if the battery reaches the
full solar passthrough threshold, the DPL will match the inverter limit
to the MPPT solar output.
2024-04-15 23:02:58 +02:00
Bernhard Kirchen
7e307114e5 Feature: DPL: introduce base load setting
on power meter issues (usually a timeout), keep the inverter enabled and
make it produce the configured base load limit if the battery can be
discharged. that should be okay since the base load config value is
expected to be small and a little less than the actual household base
load, i.e., if this amount of power is produced, the household will
consume it in any case and no energy is fed into the grid.
2024-04-15 23:02:58 +02:00
Bernhard Kirchen
cf1ea42f8b power limiter: remove obsolete enum 2024-04-15 23:02:58 +02:00
Bernhard Kirchen
4c2822cdbc remove usage of F() macro
frees 888 Bytes of flash.
2024-04-12 15:33:47 +02:00
Bernhard Kirchen
8b3a1bef47 Fix: show AC input power of Huawei AC charger in live view
makes the value match its description. since most values in the top part
of the live view are related to the AC side of the system, it makes
sense to use the correct value rather than to change the description.
2024-04-11 14:27:47 +02:00
Bernhard Kirchen
f634f58788 Fix: DPL: use correct channel type to get inverter efficiency 2024-04-11 08:28:49 +02:00
Bernhard Kirchen
a9c3e05f05 PowerMeter admin: URL examples to the top and hidden if disabled 2024-04-10 20:44:46 +02:00
PhilJaro
165a9bc168
adjust VE.Direct MPPT yield resulotion (#859) 2024-04-09 20:31:05 +02:00
eu-gh
0ed09aeb4c Feature: Huawei: add SoC stop threshold and verbose logging switch 2024-04-07 17:16:50 +02:00
SW-Nico
b9ad1e3054 VE.Direct: process more values and refactor variable names
* process "IL", "AR" and "MON"
* discard "BMV" and (unsolicited) History Data
* simplify isDataValid()
* veMpptStruct, veStruct: new, verbose variable names, including units,
  and replace floats (save values with original integer precision)
* comment on rollover situation in isDataValid()
2024-04-07 17:13:07 +02:00
Bernhard Kirchen
3934906001
Merge pull request #836 from helgeerbe/merge-v24.3.31
Merges v24.3.31 from upstream
2024-04-03 20:08:09 +02:00
Bernhard Kirchen
21cdc69625 Feature: use VE.Direct "network total DC power"
1. makes the DPL use the power generated by all connected charge
   controllers for calculations based on solar passthrough.
2. makes the network total DC power appear as "MPPT Total Power" in the
   live view at the top.
3. shows the network total DC power in the VE.Direct live data card.
2024-04-03 16:33:15 +02:00
Bernhard Kirchen
6b8c93d2e6 polish VE.Direct HEX support
* show charge controller temperature in live view
* send hex requests right after decoding a frame. this seems to have the
  best chance of getting an answer to all requests.
* deem 0xFFFFFFFF value of network total DC power as invalid indicator.
  neither network state, nor network info, nor network mode seem to
  indicate that the charge controller is part of a VE.Smart network. for
  that reason, we revert to always querying the network total DC power
  value, but testing it for max(uin32_t) value, which seems to indicate
  that the charge controller is not part of a VE.Smart network.
* improve (verbose) logging, e.g., use _logId, and print names of
  response codes and known registers, always print error messages,
  add additional tests to prevent overly verbose messages.
* move hex protocol definitions to VeDirectData.h header
  and use enum classes
* define register addresses in enum class
* move values retrieved through hex protocol into main MPPT data struct
* do not send HEX requests if the serial interface cannot send data
* detect whether smart battery sense temperature is available
* web app: make all VE.Direct sub-cards iterable. this makes addind more
  values much simpler and saves a bunch of code in the web app.
* make VeDirectFrameHandler state a type-safe enum class
* unindent MPPT controller loop()
* whitespace cleanup
2024-04-03 16:33:15 +02:00
SW-Nico
aadd7303ac Feature: add support for VE.Direct hex messages 2024-04-03 16:33:15 +02:00
helgeerbe
ff44267e73 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into merge-v24.3.31 2024-04-03 11:53:03 +02:00
Bernhard Kirchen
8c6e925ca4 VE.Direct: make state machine timeout robust against overflow 2024-04-02 21:05:59 +02:00
Bernhard Kirchen
43f553d2d4 VE.Direct MQTT: simplify code
the use of a #define is warranted here since it saves a lot of code
duplication and improves code readability.
2024-04-02 21:05:59 +02:00
Bernhard Kirchen
92a7f27919 VE.Direct: use float rather than double
double precision floating point numbers are not needed to handle
VE.Direct values. handling double is implemented in software and hence
*much* more resource intensive.
2024-04-02 21:05:59 +02:00
Bernhard Kirchen
b299b9dc6c VE.Direct: simplify access to data
hand out const& to the data structs. this is possible now that this
struct is "stable", i.e., not reset regularly.
2024-04-02 21:05:59 +02:00
Bernhard Kirchen
ad125ea804 Fix: properly handle fragmented VE.Direct messages
queue every text event until the frame was checked by it checksum. then
process the data directly into the buffer struct. do not clear the
buffer struct, so it will always include the most recent value of a
particular data point.
2024-04-02 21:05:59 +02:00
Bernhard Kirchen
187f197e32 Feature: add unique prefix to VE.Direct messages 2024-04-02 21:05:59 +02:00
MalteSchm
8abf614047 Feature: BMS initiated emergency charging
This change logically connects the AC-Charger with the BMS to add BMS
initiated emergency charging and respecting BMS current limits.
2024-04-02 21:05:00 +02:00
PhilJaro
da96273085
Fix typo in German locale (#831) 2024-04-02 12:05:45 +02:00
Thomas Basler
12588655df webapp: add app.js.gz 2024-03-31 23:07:08 +02:00
Thomas Basler
bdff1e1ac3 Added github workflow to do some repository cleanup 2024-03-31 22:39:59 +02:00
Thomas Basler
f0a8cabc2c webapp: update dependencies 2024-03-31 14:31:57 +02:00
Thomas Basler
1888054627 Fix: Re-Request grid profile parameters if received data are invalid / to short
Fixes #1874
2024-03-31 12:42:00 +02:00
Thomas Basler
6f3b8fb8e1 Fix: Change default NTP server
Fixes #1877
2024-03-31 12:27:27 +02:00
Bernhard Kirchen
91a0992964 fix: VE.Direct MPPT data not always updated in websocket
set the "last published" timestampt after handling *all* MPPTs.
2024-03-26 20:48:39 +01:00
Rene
eff8d52014 better alignment inverter, issue 360 2024-03-25 22:42:22 +01:00
David von Oheimb
811b64adb5 PowerLimiter.cpp: simplification and minor correction of logic table comments 2024-03-25 10:55:00 +01:00
Bernhard Kirchen
06f39f8396 Merge remote-tracking branch 'tbnobody/master' into development 2024-03-23 22:58:21 +01:00
Bernhard Kirchen
12f7caf998 fix: HTTP power meter: retrieve multiple JSON paths
if only a single request was made (switch "Individual HTTP requests per
phase" is off), the user could still enable phase 2 and phase 3 config
and configure a respective JSON path. however, the value was never
extracted from the successful HTTP request for phase 1.

closes #637.
2024-03-23 22:13:59 +01:00
Bernhard Kirchen
b8d0998a49 HTTP power meter: refactor tryGetFloatValueForPhase
unindent code, prepare this method for re-use on the same HTTP response
but with a different JSON path.
2024-03-23 22:13:59 +01:00
Bernhard Kirchen
c41d6f5138 HTTP power meter: remove trailing whitespace
this commit is empty when inspecting it with --ignore-all-space.
2024-03-23 22:13:59 +01:00
Bernhard Kirchen
054a677575 DPL settings in web app: split metadata from config
users are manipulating the DPL using HTTP POST requests. often they are
requesting the current settings using HTTP GET on the respective route,
then change a particular settings, and send all the data back using HTTP
POST. if they failed to remove the metadata node from the JSON,
OpenDTU-OnBattery would not be able to process the JSON due to its size.
the web app does not submit the metadata.

to avoid problems, the metadata is now split from the configuration
data.
2024-03-23 22:13:50 +01:00
Bernhard Kirchen
8bfb5c6523 implement and use Utils::checkJsonOverflow()
this method calls the overflowed() method on the respective
DynamicJsonDocument and prints a respective message if not all
data could be added to the DynamicJsonDocument.
2024-03-23 17:57:13 +01:00