Thomas Basler
f5c15a445b
Move byteAssignment to stack (avoid container) to save heap
2023-04-22 01:12:29 +02:00
Thomas Basler
7c37d289c0
Enabled additional statistics data for HMT inverters
...
Not yet shown in web ui and mqtt
2023-04-15 10:55:48 +02:00
Thomas Basler
25722f6055
Adjust buffer size in StatisticsParser for inverters with more inputs
2023-04-15 10:55:48 +02:00
Thomas Basler
dc91929d6e
First rough implementation of HMT inverters
2023-04-15 10:55:47 +02:00
Thomas Basler
a585ffe199
Add variable for max channel count (to extend serveral arrays)
2023-04-15 10:55:47 +02:00
Thomas Basler
8cbae76797
Implement offsets for YieldTotal ( #549 )
...
This allows to enter a offset in kWh in the inverter properties which will be applied to the read Yield Total value of the inverter. Using this can set your total production to zero if you e.g. are using a used device.
2023-02-13 20:25:00 +01:00
Thomas Basler
ceaf08c1a0
Hoymiles Lib: Rename ChannelMaxPower to StringMaxPower
2023-02-06 19:56:12 +01:00
Thomas Basler
d4c838a16e
BREAKING CHANGE: Prometheus API!
...
Added additional field to the prometheus api which identifies a channel by it's type. That means that e.g. channel 0 exists for type AC and DC.
This commit also introduces a additional field in the statistics byte assignment table. This field identifies whether a channel is on the AC or DC side. MQTT and WebAPI is still compatible with the previous design.
2023-02-06 19:51:10 +01:00
Thomas Basler
6b36369b06
Hoymiles Lib: Migrate byteAssign array to std::list
2023-02-06 19:44:00 +01:00
Thomas Basler
43d25dd24a
Hoymiles Lib: Change field order and move channel to first position
2022-12-25 12:02:11 +01:00
Thomas Basler
1d650b59ae
Hoymiles Lib: Add digits column to byteAssignment table
...
This allows to specify amount of digits for calculated fields
2022-12-25 12:02:11 +01:00
Thomas Basler
5feefed14e
Added missing copyright information
2022-12-14 22:37:37 +01:00
Thomas Basler
4049f6bdb7
Implemented method to get the amount of relevant digits
2022-10-31 11:51:08 +01:00
Thomas Basler
f2a08ba503
Rename FLD_PCT to FLD_PF and assign UNIT_NONE
2022-10-31 00:43:07 +01:00
Thomas Basler
3ab7d9f6fe
Fix #246 : Allow negative float values
...
This is required for the temperature field which can be negative as well
2022-10-20 18:18:36 +02:00
Thomas Basler
373e1e5e8f
Fixed function not used warning
2022-10-05 18:51:21 +02:00
Thomas Basler
862b65e844
Added method to detect whether an inverter is reachable
2022-10-01 02:16:47 +02:00
Thomas Basler
185fea987d
Added some initializations to prevent missunderstandings and errors
2022-09-05 21:53:50 +02:00
Thomas Basler
991838ae2c
Added reactive power output and display
2022-08-10 20:40:26 +02:00
Thomas Basler
ee339fa9bd
Use Parser class in Statistics and Alarm parser
2022-08-10 19:03:02 +02:00
Thomas Basler
857e4a3671
Remove RequestType and place handling of response in the command class
2022-08-03 18:50:34 +02:00
Thomas Basler
b2e41a1cfd
Fix #37 : Typo in statistics name (will lead to incompatible mqtt topic)
2022-07-24 12:38:00 +02:00
Thomas Basler
5bb9acdbc6
Refactored Hoymiles Lib: Move statistics parser into separate class
2022-07-12 18:27:56 +02:00