Thomas Basler
|
f2a08ba503
|
Rename FLD_PCT to FLD_PF and assign UNIT_NONE
|
2022-10-31 00:43:07 +01:00 |
|
Thomas Basler
|
f741fea333
|
Move serial number formatting to inverter class
|
2022-10-29 11:22:56 +02:00 |
|
Thomas Basler
|
f21dd351ef
|
Optimize performance by removing not required string constructors
|
2022-10-29 11:22:56 +02:00 |
|
Thomas Basler
|
9f4d8bdddb
|
Better limit description
|
2022-10-20 19:34:10 +02:00 |
|
Thomas Basler
|
3ab7d9f6fe
|
Fix #246: Allow negative float values
This is required for the temperature field which can be negative as well
|
2022-10-20 18:18:36 +02:00 |
|
Thomas Basler
|
678f165350
|
Fix warning: missing initializer for member
|
2022-10-19 22:16:29 +02:00 |
|
Thomas Basler
|
1dd6e9c453
|
Check 4th byte on DevInfoSimple to get max_power
This is required to detect models with fixed power limits
|
2022-10-19 22:16:18 +02:00 |
|
Thomas Basler
|
d224db4d1d
|
Fixed warning: type qualifiers ignored on function return type
|
2022-10-18 21:42:03 +02:00 |
|
Thomas Basler
|
e762abd18f
|
Show RF chip type in SystemInfoView
|
2022-10-12 00:17:40 +02:00 |
|
Thomas Basler
|
0a577f8002
|
Allow a maximum limit of 100 if limit type is relative
|
2022-10-11 23:28:22 +02:00 |
|
Thomas Basler
|
4c65be8c55
|
Add comma values to inverter limit
|
2022-10-11 23:04:43 +02:00 |
|
Thomas Basler
|
da0998c809
|
Implement inverter restart by mqtt topic
|
2022-10-09 13:16:06 +02:00 |
|
Thomas Basler
|
753ab1312e
|
DevInfoParser: Dont create string object twice
|
2022-10-08 18:15:06 +02:00 |
|
Thomas Basler
|
05d9ce4590
|
Output channel for RX messages
|
2022-10-08 18:14:43 +02:00 |
|
Thomas Basler
|
223b7ff3ce
|
Adjusted serial parsing to detect model
There are some MI-1500 models which are compatible with the Gen3 protocol.
The adjustment takes this into account.
|
2022-10-08 18:03:56 +02:00 |
|
Thomas Basler
|
1cbff8afca
|
Added HM-350 to list of known devices
|
2022-10-08 10:58:59 +02:00 |
|
Thomas Basler
|
b5cb24a46d
|
Fix AlarmDataCommand timeout for 15 entries
|
2022-10-08 02:34:54 +02:00 |
|
Thomas Basler
|
fbd58554b9
|
Show HW Version as decimal instead of hex
|
2022-10-06 23:29:18 +02:00 |
|
Thomas Basler
|
20b799b630
|
webapp: Show NRF24 connection status
|
2022-10-06 23:29:17 +02:00 |
|
Thomas Basler
|
64ae87faf1
|
Define several methods as private
|
2022-10-06 23:29:15 +02:00 |
|
Thomas Basler
|
e1690e8f74
|
Apply limit instantaneously if inverter info is available
|
2022-10-06 23:29:05 +02:00 |
|
Thomas Basler
|
b02d36d042
|
Added IDs to identifiy inverters to DevInfoParser
|
2022-10-06 18:34:31 +02:00 |
|
Thomas Basler
|
373e1e5e8f
|
Fixed function not used warning
|
2022-10-05 18:51:21 +02:00 |
|
Thomas Basler
|
7cede84785
|
Fixed uninitialized variable warning
|
2022-10-05 18:42:41 +02:00 |
|
Thomas Basler
|
d021d7529f
|
Fix parentheses error in AlarmLogParser
|
2022-10-04 23:38:32 +02:00 |
|
Thomas Basler
|
4031b71d7d
|
Implemented resend of PowerCommand
|
2022-10-04 18:12:55 +02:00 |
|
Thomas Basler
|
0fd714b165
|
Implemented first few classes for power control
TurnOn and TurnOff
|
2022-10-04 18:12:55 +02:00 |
|
Thomas Basler
|
66453b0854
|
Return correct formatted HwVersion
|
2022-10-03 13:58:50 +02:00 |
|
Thomas Basler
|
6cbcfacac6
|
Renamed several methods from Sample to Simple
|
2022-10-03 13:14:31 +02:00 |
|
Thomas Basler
|
b2a30621db
|
Extended and updated event log texts
|
2022-10-02 23:52:35 +02:00 |
|
Thomas Basler
|
eef6c37de9
|
Beautify serial output of package log
|
2022-10-02 18:43:19 +02:00 |
|
Thomas Basler
|
18ec145dda
|
Added command names to serial output
|
2022-10-02 17:17:34 +02:00 |
|
Thomas Basler
|
c8c6b2a978
|
Renamed DevInfoSample to DevInfoSimple
|
2022-10-02 17:01:46 +02:00 |
|
Thomas Basler
|
a3d9c6ae0f
|
Fixed array size of 1 channel inverters
|
2022-10-02 16:04:02 +02:00 |
|
Thomas Basler
|
67e0d0274d
|
Code cleanup: Remove not required comments
|
2022-10-02 15:44:33 +02:00 |
|
Thomas Basler
|
1aef350c2e
|
Remove not required method isA()
|
2022-10-02 15:43:11 +02:00 |
|
Thomas Basler
|
2a71be06ab
|
Fix cpplint: Adjust syntax of todo comment
|
2022-10-02 12:34:25 +02:00 |
|
Thomas Basler
|
989026d049
|
Fix cpplint: make one argument constructor explicit
|
2022-10-02 12:33:23 +02:00 |
|
Thomas Basler
|
862b65e844
|
Added method to detect whether an inverter is reachable
|
2022-10-01 02:16:47 +02:00 |
|
Thomas Basler
|
a261eb838c
|
Added method to detect whether a inverter is producing
|
2022-10-01 02:00:56 +02:00 |
|
Thomas Basler
|
754913368a
|
Implemented way to periodically fetch the current limit from the inverter
The fetch is only executed at least 4 minutes after the last set command.
Otherwise it would generate a entry in the event log (ID 2)
|
2022-09-30 18:34:30 +02:00 |
|
Thomas Basler
|
3153ee4993
|
Implemented getTimeout method in AlarmDataCommand
|
2022-09-30 18:34:30 +02:00 |
|
Thomas Basler
|
a707ab501d
|
Implemented method to check whether the last command was successfull
This also allows to retransmit the command after specific time if not successfull
|
2022-09-30 18:34:30 +02:00 |
|
Thomas Basler
|
a8ee8afb17
|
Set correct timeout for DevControlCommand
|
2022-09-30 18:34:30 +02:00 |
|
Thomas Basler
|
a2880cc447
|
Add RX main command to structure which is passed to handleResponse
This is required because the DevControlCommands just set the first byte to define whether the request was successfull or not
|
2022-09-30 18:34:30 +02:00 |
|
Thomas Basler
|
2376da1722
|
Create function to set ActivePower on inverter level
|
2022-09-30 18:34:30 +02:00 |
|
Thomas Basler
|
73e2aaf8fe
|
Implemented setting/getting of limit/type for ActivePowerControl
|
2022-09-30 18:34:30 +02:00 |
|
Thomas Basler
|
d998271944
|
Implemented crc16 calculation for DevControlCommand
|
2022-09-30 18:34:30 +02:00 |
|
Thomas Basler
|
cfdbf5963c
|
Empty classes of ActivePowerControl
|
2022-09-30 18:34:30 +02:00 |
|
Thomas Basler
|
8e2aa8981f
|
Fix #170: Update byte assignment for statistics data
|
2022-09-28 18:44:59 +02:00 |
|