Commit Graph

148 Commits

Author SHA1 Message Date
Thomas Basler
547fe41ab1 Add missing parser class to documentation 2022-10-31 14:14:01 +01:00
Thomas Basler
4049f6bdb7 Implemented method to get the amount of relevant digits 2022-10-31 11:51:08 +01:00
Thomas Basler
27ed4e3cda BREAKING: Change power factor from percent value to value between 0 and 1
If you write these values to a database you have to update them.
2022-10-31 10:50:31 +01:00
Thomas Basler
f2a08ba503 Rename FLD_PCT to FLD_PF and assign UNIT_NONE 2022-10-31 00:43:07 +01:00
Thomas Basler
f741fea333 Move serial number formatting to inverter class 2022-10-29 11:22:56 +02:00
Thomas Basler
f21dd351ef Optimize performance by removing not required string constructors 2022-10-29 11:22:56 +02:00
Thomas Basler
9f4d8bdddb Better limit description 2022-10-20 19:34:10 +02:00
Thomas Basler
3ab7d9f6fe Fix #246: Allow negative float values
This is required for the temperature field which can be negative as well
2022-10-20 18:18:36 +02:00
Thomas Basler
678f165350 Fix warning: missing initializer for member 2022-10-19 22:16:29 +02:00
Thomas Basler
1dd6e9c453 Check 4th byte on DevInfoSimple to get max_power
This is required to detect models with fixed power limits
2022-10-19 22:16:18 +02:00
Thomas Basler
d224db4d1d Fixed warning: type qualifiers ignored on function return type 2022-10-18 21:42:03 +02:00
Thomas Basler
e762abd18f Show RF chip type in SystemInfoView 2022-10-12 00:17:40 +02:00
Thomas Basler
0a577f8002 Allow a maximum limit of 100 if limit type is relative 2022-10-11 23:28:22 +02:00
Thomas Basler
4c65be8c55 Add comma values to inverter limit 2022-10-11 23:04:43 +02:00
Thomas Basler
da0998c809 Implement inverter restart by mqtt topic 2022-10-09 13:16:06 +02:00
Thomas Basler
753ab1312e DevInfoParser: Dont create string object twice 2022-10-08 18:15:06 +02:00
Thomas Basler
05d9ce4590 Output channel for RX messages 2022-10-08 18:14:43 +02:00
Thomas Basler
223b7ff3ce Adjusted serial parsing to detect model
There are some MI-1500 models which are compatible with the Gen3 protocol.
The adjustment takes this into account.
2022-10-08 18:03:56 +02:00
Thomas Basler
1cbff8afca Added HM-350 to list of known devices 2022-10-08 10:58:59 +02:00
Thomas Basler
b5cb24a46d Fix AlarmDataCommand timeout for 15 entries 2022-10-08 02:34:54 +02:00
Thomas Basler
fbd58554b9 Show HW Version as decimal instead of hex 2022-10-06 23:29:18 +02:00
Thomas Basler
20b799b630 webapp: Show NRF24 connection status 2022-10-06 23:29:17 +02:00
Thomas Basler
64ae87faf1 Define several methods as private 2022-10-06 23:29:15 +02:00
Thomas Basler
e1690e8f74 Apply limit instantaneously if inverter info is available 2022-10-06 23:29:05 +02:00
Thomas Basler
b02d36d042 Added IDs to identifiy inverters to DevInfoParser 2022-10-06 18:34:31 +02:00
Thomas Basler
373e1e5e8f Fixed function not used warning 2022-10-05 18:51:21 +02:00
Thomas Basler
7cede84785 Fixed uninitialized variable warning 2022-10-05 18:42:41 +02:00
Thomas Basler
d021d7529f Fix parentheses error in AlarmLogParser 2022-10-04 23:38:32 +02:00
Thomas Basler
4031b71d7d Implemented resend of PowerCommand 2022-10-04 18:12:55 +02:00
Thomas Basler
0fd714b165 Implemented first few classes for power control
TurnOn and TurnOff
2022-10-04 18:12:55 +02:00
Thomas Basler
66453b0854 Return correct formatted HwVersion 2022-10-03 13:58:50 +02:00
Thomas Basler
6cbcfacac6 Renamed several methods from Sample to Simple 2022-10-03 13:14:31 +02:00
Thomas Basler
b2a30621db Extended and updated event log texts 2022-10-02 23:52:35 +02:00
Thomas Basler
eef6c37de9 Beautify serial output of package log 2022-10-02 18:43:19 +02:00
Thomas Basler
18ec145dda Added command names to serial output 2022-10-02 17:17:34 +02:00
Thomas Basler
c8c6b2a978 Renamed DevInfoSample to DevInfoSimple 2022-10-02 17:01:46 +02:00
Thomas Basler
a3d9c6ae0f Fixed array size of 1 channel inverters 2022-10-02 16:04:02 +02:00
Thomas Basler
67e0d0274d Code cleanup: Remove not required comments 2022-10-02 15:44:33 +02:00
Thomas Basler
1aef350c2e Remove not required method isA() 2022-10-02 15:43:11 +02:00
Thomas Basler
2a71be06ab Fix cpplint: Adjust syntax of todo comment 2022-10-02 12:34:25 +02:00
Thomas Basler
989026d049 Fix cpplint: make one argument constructor explicit 2022-10-02 12:33:23 +02:00
Thomas Basler
862b65e844 Added method to detect whether an inverter is reachable 2022-10-01 02:16:47 +02:00
Thomas Basler
a261eb838c Added method to detect whether a inverter is producing 2022-10-01 02:00:56 +02:00
Thomas Basler
754913368a Implemented way to periodically fetch the current limit from the inverter
The fetch is only executed at least 4 minutes after the last set command.
Otherwise it would generate a entry in the event log (ID 2)
2022-09-30 18:34:30 +02:00
Thomas Basler
3153ee4993 Implemented getTimeout method in AlarmDataCommand 2022-09-30 18:34:30 +02:00
Thomas Basler
a707ab501d Implemented method to check whether the last command was successfull
This also allows to retransmit the command after specific time if not successfull
2022-09-30 18:34:30 +02:00
Thomas Basler
a8ee8afb17 Set correct timeout for DevControlCommand 2022-09-30 18:34:30 +02:00
Thomas Basler
a2880cc447 Add RX main command to structure which is passed to handleResponse
This is required because the DevControlCommands just set the first byte to define whether the request was successfull or not
2022-09-30 18:34:30 +02:00
Thomas Basler
2376da1722 Create function to set ActivePower on inverter level 2022-09-30 18:34:30 +02:00
Thomas Basler
73e2aaf8fe Implemented setting/getting of limit/type for ActivePowerControl 2022-09-30 18:34:30 +02:00