Commit Graph

244 Commits

Author SHA1 Message Date
Thomas Basler
b7fb294368 Set DTU serial for CMT modules 2023-04-15 10:55:47 +02:00
Thomas Basler
dc91929d6e First rough implementation of HMT inverters 2023-04-15 10:55:47 +02:00
Thomas Basler
45882543b6 Allow dynamic pin mapping for CMT module 2023-04-15 10:55:47 +02:00
Thomas Basler
3c0d89f599 Replaced println by printf and code style changes 2023-04-15 10:55:47 +02:00
Thomas Basler
a585ffe199 Add variable for max channel count (to extend serveral arrays) 2023-04-15 10:55:47 +02:00
Thomas Basler
90c689a41a Implement HoymilesRadio_CMT 2023-04-15 10:55:47 +02:00
Thomas Basler
8927b8374a Added HMS/HMT devices to the DevInfoParser 2023-04-15 10:55:47 +02:00
Thomas Basler
41e2ba7fcf Move serveral methods from the HoymilesRadio_NRF class to the HoymilesRadio base class 2023-04-15 10:55:47 +02:00
Thomas Basler
8404dd57a7 Add a HoymilesRadio base class
This enables to have multiple radio implementations while the inverter classes just refere to the base class
2023-04-15 10:55:47 +02:00
Thomas Basler
a7e9aaa862 Move reference to the radio instance into the inverter instance
This is required to support different radios for different inverters
2023-04-15 10:55:47 +02:00
Thomas Basler
c2e4c5d43e Added first implementation of HMS inverter classes 2023-04-15 10:55:47 +02:00
Thomas Basler
a252d2ac3a Added CMT2300 driver 2023-04-15 10:55:47 +02:00
Thomas Basler
299ba8f27a Doc: Resolve Markdown Lint errors 2023-04-06 23:34:35 +02:00
Thomas Basler
df468086e4 TimeoutHelper: Allow resetting the last value 2023-04-04 18:52:00 +02:00
Thomas Basler
d6028cbd50 Remove not required F() macro. Frees ~20kb flash. 2023-04-04 18:51:18 +02:00
Thomas Basler
d099bc4ff8 Fix #753: Only apply offset if data is in the buffer to prevent negative numbers 2023-03-30 22:11:20 +02:00
Thomas Basler
041249523e Fixed typo in comment 2023-03-28 22:41:27 +02:00
Thomas Basler
8d8c7f8a71 Fixed typo: Successfull --> Successful 2023-03-23 23:30:55 +01:00
Thomas Basler
70130f47ae Remove not required register keyword 2023-03-20 18:05:57 +01:00
Luca Kröger
cb40a07489 added support for ESP32S2 2023-03-07 15:39:05 +01:00
Thomas Basler
f423ce0a6b Fix #644: Added additional HM-400 to mapping table 2023-02-28 19:42:15 +01:00
Thomas Basler
27f230e94d Merge branch 'pr634' into dev 2023-02-26 19:49:58 +01:00
Marc-Philip
9f7f7ca49b
fix conjugation 2023-02-26 19:10:13 +01:00
Thomas Basler
612e5f73b7 Fixed compilation issue for esp32-s3 2023-02-23 23:28:34 +01:00
Thomas Basler
fa3d0370f0 Fix isReachable and isProducing based on PollEnabled 2023-02-18 23:50:16 +01:00
Thomas Basler
7da782c4ef Hoymiles Lib: Added flags to inverter to enable/disable polling and commands to the inverter 2023-02-18 15:51:46 +01:00
Thomas Basler
8cbae76797 Implement offsets for YieldTotal (#549)
This allows to enter a offset in kWh in the inverter properties which will be applied to the read Yield Total value of the inverter. Using this can set your total production to zero if you e.g. are using a used device.
2023-02-13 20:25:00 +01:00
Thomas Basler
ceaf08c1a0 Hoymiles Lib: Rename ChannelMaxPower to StringMaxPower 2023-02-06 19:56:12 +01:00
Thomas Basler
d4c838a16e BREAKING CHANGE: Prometheus API!
Added additional field to the prometheus api which identifies a channel by it's type. That means that e.g. channel 0  exists for type AC and DC.

This commit also introduces a additional field in the statistics byte assignment table. This field identifies whether a channel is on the AC or DC side. MQTT and WebAPI is still compatible with the previous design.
2023-02-06 19:51:10 +01:00
Thomas Basler
6b36369b06 Hoymiles Lib: Migrate byteAssign array to std::list 2023-02-06 19:44:00 +01:00
Thomas Basler
6235342cf2 Fix compile issue with ESP32-C3 MCU 2023-01-18 23:08:01 +01:00
Thomas Basler
7c33688167 Use same line ending in printf as in println
This prevents mistakes in the webconsole
2023-01-04 18:48:33 +01:00
Thomas Basler
43d25dd24a Hoymiles Lib: Change field order and move channel to first position 2022-12-25 12:02:11 +01:00
Thomas Basler
1d650b59ae Hoymiles Lib: Add digits column to byteAssignment table
This allows to specify amount of digits for calculated fields
2022-12-25 12:02:11 +01:00
Thomas Basler
f689fedf4e Hoymiles Lib: Remove hard coded Serial output
The serial port for output of debug information can now changed during runtime
2022-12-19 20:52:12 +01:00
Thomas Basler
5feefed14e Added missing copyright information 2022-12-14 22:37:37 +01:00
Thomas Basler
5dd4d5b452 Introduce MqttSubscribeParser and moved inverter specific subscribes to MqttHandleInverterClass
This allows individual callback functions for each subscribed topic. Allows easier implementation of further mqtt functions
2022-12-14 20:42:23 +01:00
Thomas Basler
0d350b14bb Migrated _rxBuffer from CircularBuffer to queue 2022-11-28 18:25:50 +01:00
Thomas Basler
3c8bd56576 Added MI-1500 with Gen3 Protocol to Hardware Id list 2022-11-28 18:16:46 +01:00
Thomas Basler
36abaeee12 Moved pin assignment outside the hoymiles library
Allows setting the pins during runtime and not  just using the defines
2022-11-27 12:07:25 +01:00
Thomas Basler
6388be7a9e Added new Hardware Part Number for HM-800
See #363
2022-11-21 17:52:27 +01:00
Thomas Basler
2b2afee770 Fix issue that in multi inverter environments some inverters where not fetched
When the radio was busy, the current inverter was just skipped and switched to the next one
2022-11-15 22:30:29 +01:00
Thomas Basler
dd7babb448 Added a timeout of 5ms to detect current time.
This prevents false positives when a interrupt occours during the reading of the time
2022-11-14 20:19:38 +01:00
Thomas Basler
6229e4b5a8 Fixed issue that fetching stopped when inverter was deleted
This happend when due to special timing the last inverter was deleted. In that case interverPos was never changed and the fetching process stucked
2022-11-14 20:00:16 +01:00
Thomas Basler
0d619e780a Prevent null pointer exception
It could occur that the command queue contained commands for inverters which are already deleted.
Therefor it has to be checked that getInverterBySerial returns a valid inverter
2022-11-10 18:32:28 +01:00
Thomas Basler
26b9bbf537 Prevent null pointer exception when deleting inverter
The removeInverterBySerial can be called in a webserver callback method.
This is maybe executed on another core which can then run in parallel to the radio loop hoymiles loop.
Accessing inverters which are already removed can lead to exceptions.
The Semaphore prevents that parallel execution
2022-11-10 18:26:01 +01:00
Thomas Basler
547fe41ab1 Add missing parser class to documentation 2022-10-31 14:14:01 +01:00
Thomas Basler
4049f6bdb7 Implemented method to get the amount of relevant digits 2022-10-31 11:51:08 +01:00
Thomas Basler
27ed4e3cda BREAKING: Change power factor from percent value to value between 0 and 1
If you write these values to a database you have to update them.
2022-10-31 10:50:31 +01:00
Thomas Basler
f2a08ba503 Rename FLD_PCT to FLD_PF and assign UNIT_NONE 2022-10-31 00:43:07 +01:00
Thomas Basler
f741fea333 Move serial number formatting to inverter class 2022-10-29 11:22:56 +02:00
Thomas Basler
f21dd351ef Optimize performance by removing not required string constructors 2022-10-29 11:22:56 +02:00
Thomas Basler
9f4d8bdddb Better limit description 2022-10-20 19:34:10 +02:00
Thomas Basler
3ab7d9f6fe Fix #246: Allow negative float values
This is required for the temperature field which can be negative as well
2022-10-20 18:18:36 +02:00
Thomas Basler
678f165350 Fix warning: missing initializer for member 2022-10-19 22:16:29 +02:00
Thomas Basler
1dd6e9c453 Check 4th byte on DevInfoSimple to get max_power
This is required to detect models with fixed power limits
2022-10-19 22:16:18 +02:00
Thomas Basler
d224db4d1d Fixed warning: type qualifiers ignored on function return type 2022-10-18 21:42:03 +02:00
Thomas Basler
e762abd18f Show RF chip type in SystemInfoView 2022-10-12 00:17:40 +02:00
Thomas Basler
0a577f8002 Allow a maximum limit of 100 if limit type is relative 2022-10-11 23:28:22 +02:00
Thomas Basler
4c65be8c55 Add comma values to inverter limit 2022-10-11 23:04:43 +02:00
Thomas Basler
da0998c809 Implement inverter restart by mqtt topic 2022-10-09 13:16:06 +02:00
Thomas Basler
753ab1312e DevInfoParser: Dont create string object twice 2022-10-08 18:15:06 +02:00
Thomas Basler
05d9ce4590 Output channel for RX messages 2022-10-08 18:14:43 +02:00
Thomas Basler
223b7ff3ce Adjusted serial parsing to detect model
There are some MI-1500 models which are compatible with the Gen3 protocol.
The adjustment takes this into account.
2022-10-08 18:03:56 +02:00
Thomas Basler
1cbff8afca Added HM-350 to list of known devices 2022-10-08 10:58:59 +02:00
Thomas Basler
b5cb24a46d Fix AlarmDataCommand timeout for 15 entries 2022-10-08 02:34:54 +02:00
Thomas Basler
fbd58554b9 Show HW Version as decimal instead of hex 2022-10-06 23:29:18 +02:00
Thomas Basler
20b799b630 webapp: Show NRF24 connection status 2022-10-06 23:29:17 +02:00
Thomas Basler
64ae87faf1 Define several methods as private 2022-10-06 23:29:15 +02:00
Thomas Basler
e1690e8f74 Apply limit instantaneously if inverter info is available 2022-10-06 23:29:05 +02:00
Thomas Basler
b02d36d042 Added IDs to identifiy inverters to DevInfoParser 2022-10-06 18:34:31 +02:00
Thomas Basler
373e1e5e8f Fixed function not used warning 2022-10-05 18:51:21 +02:00
Thomas Basler
7cede84785 Fixed uninitialized variable warning 2022-10-05 18:42:41 +02:00
Thomas Basler
d021d7529f Fix parentheses error in AlarmLogParser 2022-10-04 23:38:32 +02:00
Thomas Basler
4031b71d7d Implemented resend of PowerCommand 2022-10-04 18:12:55 +02:00
Thomas Basler
0fd714b165 Implemented first few classes for power control
TurnOn and TurnOff
2022-10-04 18:12:55 +02:00
Thomas Basler
66453b0854 Return correct formatted HwVersion 2022-10-03 13:58:50 +02:00
Thomas Basler
6cbcfacac6 Renamed several methods from Sample to Simple 2022-10-03 13:14:31 +02:00
Thomas Basler
b2a30621db Extended and updated event log texts 2022-10-02 23:52:35 +02:00
Thomas Basler
eef6c37de9 Beautify serial output of package log 2022-10-02 18:43:19 +02:00
Thomas Basler
18ec145dda Added command names to serial output 2022-10-02 17:17:34 +02:00
Thomas Basler
c8c6b2a978 Renamed DevInfoSample to DevInfoSimple 2022-10-02 17:01:46 +02:00
Thomas Basler
a3d9c6ae0f Fixed array size of 1 channel inverters 2022-10-02 16:04:02 +02:00
Thomas Basler
67e0d0274d Code cleanup: Remove not required comments 2022-10-02 15:44:33 +02:00
Thomas Basler
1aef350c2e Remove not required method isA() 2022-10-02 15:43:11 +02:00
Thomas Basler
2a71be06ab Fix cpplint: Adjust syntax of todo comment 2022-10-02 12:34:25 +02:00
Thomas Basler
989026d049 Fix cpplint: make one argument constructor explicit 2022-10-02 12:33:23 +02:00
Thomas Basler
862b65e844 Added method to detect whether an inverter is reachable 2022-10-01 02:16:47 +02:00
Thomas Basler
a261eb838c Added method to detect whether a inverter is producing 2022-10-01 02:00:56 +02:00
Thomas Basler
754913368a Implemented way to periodically fetch the current limit from the inverter
The fetch is only executed at least 4 minutes after the last set command.
Otherwise it would generate a entry in the event log (ID 2)
2022-09-30 18:34:30 +02:00
Thomas Basler
3153ee4993 Implemented getTimeout method in AlarmDataCommand 2022-09-30 18:34:30 +02:00
Thomas Basler
a707ab501d Implemented method to check whether the last command was successfull
This also allows to retransmit the command after specific time if not successfull
2022-09-30 18:34:30 +02:00
Thomas Basler
a8ee8afb17 Set correct timeout for DevControlCommand 2022-09-30 18:34:30 +02:00
Thomas Basler
a2880cc447 Add RX main command to structure which is passed to handleResponse
This is required because the DevControlCommands just set the first byte to define whether the request was successfull or not
2022-09-30 18:34:30 +02:00
Thomas Basler
2376da1722 Create function to set ActivePower on inverter level 2022-09-30 18:34:30 +02:00
Thomas Basler
73e2aaf8fe Implemented setting/getting of limit/type for ActivePowerControl 2022-09-30 18:34:30 +02:00
Thomas Basler
d998271944 Implemented crc16 calculation for DevControlCommand 2022-09-30 18:34:30 +02:00
Thomas Basler
cfdbf5963c Empty classes of ActivePowerControl 2022-09-30 18:34:30 +02:00
Thomas Basler
8e2aa8981f Fix #170: Update byte assignment for statistics data 2022-09-28 18:44:59 +02:00
Thomas Basler
b8f03eddfd Fixed scheduler issue
When the RF method took very long inverters where skipped
2022-09-25 17:28:50 +02:00