Thomas Basler
06651f365a
Feature: First version of GridProfile Parser which shows all values contained in the profile.
2023-12-11 14:58:17 +01:00
Thomas Basler
00bc631e87
Feature: Added basic Grid Profile parser which shows the used profile and version
...
Other values are still outstanding.
2023-12-09 11:12:37 +01:00
Thomas Basler
9ae791edd4
Feature: Added ability to change the brightness of the LEDs
...
Based on the idea of @moritzlerch with several modifications like pwmTable and structure
2023-12-07 12:46:38 +01:00
Thomas Basler
1de3b48166
Feature: Implement offset cache for "YieldDay"
...
Thanks to @broth-itk for the idea!
Fix : #1258 #1397
2023-11-22 20:21:25 +01:00
Thomas Basler
ee4811bbe7
Feature: Allow configuration of LWT QoS
2023-11-19 16:17:10 +01:00
CommanderRedYT
7c875187a8
Implemented mDNS
2023-10-30 20:53:45 +01:00
Thomas Basler
0533c0bcc8
webapp: Rename Fehlernummer to ID
...
It's not just errors, its also regular messges
2023-09-13 23:19:43 +02:00
Thomas Basler
9ac6dd6e8d
Feature: First very basic support to read the grid profile
...
The parser is still missing and requires community support to collect data.
2023-09-07 22:08:07 +02:00
Thomas Basler
ec9af886d5
Feature: Added option to set daily yield to zero at midnight
2023-09-05 20:27:52 +02:00
Thomas Basler
6127fbe940
Feature: Added option to set runtime values to zero when inverter becames unreachable
2023-09-02 12:22:22 +02:00
Thomas Basler
2c41be106e
Feature: Allow setting of the Reachable Threshold per inverter
2023-09-01 19:17:12 +02:00
Thomas Basler
c5f9f460cd
Feature: Added config option to change MQTT CleanSession Flag
2023-09-01 18:03:30 +02:00
Thomas Basler
b95236c170
Feature: webapp: Move inverter settings into different tabs
2023-09-01 00:20:56 +02:00
Stefan Schultheis, OE1SCS
94f6078c9e
Update de.json
...
bessere Übersetzung
2023-08-09 18:20:36 +02:00
Thomas Basler
1146e15ea6
Move units from description to postfix for AP timeout
2023-07-22 18:30:18 +02:00
Martin Dummer
8bfa7e530c
Feature: Admin AccessPoint Timeout now configurable
...
Make the administrative accesspoint timeout configurable. The default
value is 3 minutes, values from 0-99999 are possible, where 0 means
infinite (no timeout).
Signed-off-by: Martin Dummer <martin.dummer@gmx.net>
2023-07-22 18:14:07 +02:00
Thomas Basler
eaacce7483
Feature: Show error in webapp if pin_mapping.json contains syntax errors
2023-07-22 15:51:16 +02:00
Thomas Basler
91d3cd1da2
Feature: Show BSSID in the web interface
2023-06-08 19:56:22 +02:00
Thomas Basler
5a37948ca9
Fix: If no sunset/sunrise calculation is possible a wrong value is shown
...
This is catched now and a proper message is shown in the web UI. Also the mode is set to day.
2023-06-01 18:39:50 +02:00
Thomas Basler
1c8bd8091b
Feature: Allow reordering of the inverters in the live view
...
Reordering can be done in the inverter settings via drag&drop.
2023-05-29 20:17:07 +02:00
Thomas Basler
e7198073af
Feature: Allow configuration of sunset type
2023-05-24 19:21:44 +02:00
Thomas Basler
752362d2df
Feature: Added localization setting to display
...
Its possible to change the language of the display
2023-05-23 18:25:12 +02:00
Thomas Basler
efcbd81927
Feature: Add used PIO environment to the system info page
2023-05-08 21:43:50 +02:00
Thomas Basler
85070ffda0
webapp: Add hint to cmt frequency that it can take up to 15min until a connection is established
2023-04-15 10:55:48 +02:00
Thomas Basler
d6c2a4ba1c
webapp: Remove hard coded texts in dtuadmin view
2023-04-15 10:55:48 +02:00
Thomas Basler
1e7b16adb9
webapp: Nicer cmt frequency input
2023-04-15 10:55:48 +02:00
Thomas Basler
371e405eed
Added configuration of CMT modules frequency to webapp
2023-04-15 10:55:48 +02:00
Thomas Basler
854fcdaeae
Allow configuration of the TX PA Level of the CMT2300A module
2023-04-15 10:55:48 +02:00
Thomas Basler
0ec90e0000
webapp: Adjusted radio problem hint in home view to detect problems of nrf and cmt radios
2023-04-15 10:55:47 +02:00
Thomas Basler
c19d2007bd
webapp: Added cmt radio status to system overview
2023-04-15 10:55:47 +02:00
Martin Dummer
971ae6d1be
Feature: MQTT add TLS authentication
...
User asked for TLS client certificate based login from DTU to MQTT
server. This PR implements storage and use of x509 client certificate
and private key.
Signed-off-by: Martin Dummer <martin.dummer@gmx.net>
2023-04-12 08:33:10 +02:00
Thomas Basler
d03b8f6e5b
webapp: Implemented reload button for info views
2023-03-31 20:05:06 +02:00
Thomas Basler
2e33f5cd51
Display: Implement rotation setting and removed icons
2023-03-15 20:20:14 +01:00
Thomas Basler
95741c7fa2
webapp: Implement dark theme
2023-03-06 19:42:37 +01:00
Thomas Basler
3c9639bb53
WebApp: Show additional inverter info in DevInfo dialog
...
* Production Year
* Production Week
2023-02-23 23:08:16 +01:00
Thomas Basler
39c55501ea
Merge branch 'pr594' into dev
2023-02-20 19:41:49 +01:00
Thomas Basler
f6dedf7adb
webapp: Add missing translations
2023-02-18 22:04:18 +01:00
Thomas Basler
e5e236510e
webapp: Add additional hint that no data is received if no sun is shining
2023-02-18 20:47:09 +01:00
Thomas Basler
4c14417ea8
webapp: Add column inverter settings to show inverter send/receive status
2023-02-18 20:29:18 +01:00
Thomas Basler
cd99ab8e42
Added settings to pause polling/sending commands in general and at night
2023-02-18 19:44:16 +01:00
Thomas Basler
b319c78dc1
Added methods to calculate and show sunrise and sunset times
2023-02-18 18:15:48 +01:00
Thomas Basler
19a1c0aa54
Added config parameters to set longitude and latitude
2023-02-18 16:53:28 +01:00
Torben Woltjen
fc86ff7ade
Fix typos in German localisation and change some words to more common one
...
In German, you bascially never can have two nouns after each other, just separated by a space. Either you write them together (Dampfschifffahrtsgesellschaftskapitän) or in case one of them is a foreign word, you *can* but don't have to separate them by a hyphen (Firmware-Aktualisierung).
Additionally, I've changed some more details like WiFi -> WLAN, because that is a lot more common in German. I've also removed the "-Einstellungen" from the settings dropdown, because having it on every single item just makes it less readable (especially considerung the dropdown itself already is called "Einstellungen", so it's clear, all those items are for settings) (now it does work out the same way as the Info dropdown)
2023-02-16 10:39:43 +01:00
Thomas Basler
8cbae76797
Implement offsets for YieldTotal ( #549 )
...
This allows to enter a offset in kWh in the inverter properties which will be applied to the read Yield Total value of the inverter. Using this can set your total production to zero if you e.g. are using a used device.
2023-02-13 20:25:00 +01:00
Thomas Basler
3b7aef63f8
BREAKING CHANGE: Web API!
...
In order to support multiple AC channels in future the WebAPI had to be changed. AC and DC channels are now grouped in a sub object containing the channels beginning with 0.
2023-02-13 18:37:55 +01:00
Thomas Basler
ad64e0db34
webapp: Added hint regarding site reloading
2023-01-23 19:18:36 +01:00
Thomas Basler
5abf7dc55e
webapp: Fix typo in german translation
2023-01-20 18:52:45 +01:00
Thomas Basler
ce287bc700
Added additional explanation regarding power safe and screensaver
2023-01-20 18:51:30 +01:00
Thomas Basler
e0712ed7bc
webapi: Added frontend for display settings
2023-01-20 18:28:34 +01:00
Thomas Basler
19b42223f5
webapp: Show current active pin config
2023-01-16 23:41:58 +01:00