Doc: Add hint to adjusted partition upgrade guide to use only one .bin file
This commit is contained in:
parent
08f47c2f4c
commit
88de38e694
@ -12,13 +12,10 @@ There are several possibilities to update the partition table:
|
||||
|
||||
- Any kind of flash interface
|
||||
|
||||
If you like to use any kind of flash interface like `esptool.py`, Espressif Flash Download Tool, ESP_Flasher or esptool-js you have to make sure to upload **ALL** provided .bin files. It is important to enter the correct target addresses.
|
||||
If you like to use any kind of flash interface like `esptool.py`, Espressif Flash Download Tool, ESP_Flasher or esptool-js you have to make sure to upload the provided .factory.bin file. It is important to enter the correct target address.
|
||||
|
||||
| Address | File |
|
||||
| ---------| ---------------------- |
|
||||
| 0x1000 | bootloader.bin |
|
||||
| 0x8000 | partitions.bin |
|
||||
| 0xe000 | boot_app0.bin |
|
||||
| 0x10000 | opendtu-*.bin |
|
||||
| 0x0 | opendtu-*.factory.bin |
|
||||
|
||||
After upgrading the ESP32 will open the intergrated access point (AP) again. Just connect to it using the default password ("openDTU42"). If you are connected, just visit <http://192.168.4.1> and enter the "Configuration Management". Recover the previously backuped config files.
|
||||
|
||||