Implement different Eventlog messages for HMT inverters
Also make message list much more readable
This commit is contained in:
parent
06cc19fc70
commit
67055276ca
@ -5,7 +5,7 @@
|
||||
#include "HMT_6CH.h"
|
||||
|
||||
HMT_6CH::HMT_6CH(HoymilesRadio* radio, uint64_t serial)
|
||||
: HMS_Abstract(radio, serial) {};
|
||||
: HMT_Abstract(radio, serial) {};
|
||||
|
||||
bool HMT_6CH::isValidSerial(uint64_t serial)
|
||||
{
|
||||
|
||||
@ -1,9 +1,9 @@
|
||||
// SPDX-License-Identifier: GPL-2.0-or-later
|
||||
#pragma once
|
||||
|
||||
#include "HMS_Abstract.h"
|
||||
#include "HMT_Abstract.h"
|
||||
|
||||
class HMT_6CH : public HMS_Abstract {
|
||||
class HMT_6CH : public HMT_Abstract {
|
||||
public:
|
||||
explicit HMT_6CH(HoymilesRadio* radio, uint64_t serial);
|
||||
static bool isValidSerial(uint64_t serial);
|
||||
|
||||
12
lib/Hoymiles/src/inverters/HMT_Abstract.cpp
Normal file
12
lib/Hoymiles/src/inverters/HMT_Abstract.cpp
Normal file
@ -0,0 +1,12 @@
|
||||
// SPDX-License-Identifier: GPL-2.0-or-later
|
||||
/*
|
||||
* Copyright (C) 2023 Thomas Basler and others
|
||||
*/
|
||||
#include "HMT_Abstract.h"
|
||||
#include "parser/AlarmLogParser.h"
|
||||
|
||||
HMT_Abstract::HMT_Abstract(HoymilesRadio* radio, uint64_t serial)
|
||||
: HM_Abstract(radio, serial)
|
||||
{
|
||||
EventLog()->setMessageType(AlarmMessageType_t::HMT);
|
||||
};
|
||||
9
lib/Hoymiles/src/inverters/HMT_Abstract.h
Normal file
9
lib/Hoymiles/src/inverters/HMT_Abstract.h
Normal file
@ -0,0 +1,9 @@
|
||||
// SPDX-License-Identifier: GPL-2.0-or-later
|
||||
#pragma once
|
||||
|
||||
#include "HM_Abstract.h"
|
||||
|
||||
class HMT_Abstract : public HM_Abstract {
|
||||
public:
|
||||
explicit HMT_Abstract(HoymilesRadio* radio, uint64_t serial);
|
||||
};
|
||||
@ -1,11 +1,90 @@
|
||||
// SPDX-License-Identifier: GPL-2.0-or-later
|
||||
/*
|
||||
* Copyright (C) 2022 Thomas Basler and others
|
||||
* Copyright (C) 2022-2023 Thomas Basler and others
|
||||
*/
|
||||
#include "AlarmLogParser.h"
|
||||
#include "../Hoymiles.h"
|
||||
#include <cstring>
|
||||
|
||||
const std::list<AlarmMessage_t> AlarmLogParser::_alarmMessages = {
|
||||
{ AlarmMessageType_t::ALL, 1, "Inverter start" },
|
||||
{ AlarmMessageType_t::ALL, 2, "DTU command failed" },
|
||||
{ AlarmMessageType_t::ALL, 121, "Over temperature protection" },
|
||||
{ AlarmMessageType_t::ALL, 124, "Shut down by remote control" },
|
||||
{ AlarmMessageType_t::ALL, 125, "Grid configuration parameter error" },
|
||||
{ AlarmMessageType_t::ALL, 126, "Software error code 126" },
|
||||
{ AlarmMessageType_t::ALL, 127, "Firmware error" },
|
||||
{ AlarmMessageType_t::ALL, 128, "Software error code 128" },
|
||||
{ AlarmMessageType_t::ALL, 129, "Abnormal bias" },
|
||||
{ AlarmMessageType_t::ALL, 130, "Offline" },
|
||||
{ AlarmMessageType_t::ALL, 141, "Grid: Grid overvoltage" },
|
||||
{ AlarmMessageType_t::ALL, 142, "Grid: 10 min value grid overvoltage" },
|
||||
{ AlarmMessageType_t::ALL, 143, "Grid: Grid undervoltage" },
|
||||
{ AlarmMessageType_t::ALL, 144, "Grid: Grid overfrequency" },
|
||||
{ AlarmMessageType_t::ALL, 145, "Grid: Grid underfrequency" },
|
||||
{ AlarmMessageType_t::ALL, 146, "Grid: Rapid grid frequency change rate" },
|
||||
{ AlarmMessageType_t::ALL, 147, "Grid: Power grid outage" },
|
||||
{ AlarmMessageType_t::ALL, 148, "Grid: Grid disconnection" },
|
||||
{ AlarmMessageType_t::ALL, 149, "Grid: Island detected" },
|
||||
{ AlarmMessageType_t::HMT, 171, "Grid: Abnormal phase difference between phase to phase" },
|
||||
{ AlarmMessageType_t::ALL, 205, "MPPT-A: Input overvoltage" },
|
||||
{ AlarmMessageType_t::ALL, 206, "MPPT-B: Input overvoltage" },
|
||||
{ AlarmMessageType_t::ALL, 207, "MPPT-A: Input undervoltage" },
|
||||
{ AlarmMessageType_t::ALL, 208, "MPPT-B: Input undervoltage" },
|
||||
{ AlarmMessageType_t::ALL, 209, "PV-1: No input" },
|
||||
{ AlarmMessageType_t::ALL, 210, "PV-2: No input" },
|
||||
{ AlarmMessageType_t::ALL, 211, "PV-3: No input" },
|
||||
{ AlarmMessageType_t::ALL, 212, "PV-4: No input" },
|
||||
{ AlarmMessageType_t::ALL, 213, "MPPT-A: PV-1 & PV-2 abnormal wiring" },
|
||||
{ AlarmMessageType_t::ALL, 214, "MPPT-B: PV-3 & PV-4 abnormal wiring" },
|
||||
{ AlarmMessageType_t::ALL, 215, "PV-1: Input overvoltage" },
|
||||
{ AlarmMessageType_t::HMT, 215, "MPPT-C: Input overvoltage" },
|
||||
{ AlarmMessageType_t::ALL, 216, "PV-1: Input undervoltage" },
|
||||
{ AlarmMessageType_t::HMT, 216, "MPPT-C: Input undervoltage" },
|
||||
{ AlarmMessageType_t::ALL, 217, "PV-2: Input overvoltage" },
|
||||
{ AlarmMessageType_t::HMT, 217, "PV-5: No input" },
|
||||
{ AlarmMessageType_t::ALL, 218, "PV-2: Input undervoltage" },
|
||||
{ AlarmMessageType_t::HMT, 218, "PV-6: No input" },
|
||||
{ AlarmMessageType_t::ALL, 219, "PV-3: Input overvoltage" },
|
||||
{ AlarmMessageType_t::HMT, 219, "MPPT-C: PV-5 & PV-6 abnormal wiring" },
|
||||
{ AlarmMessageType_t::ALL, 220, "PV-3: Input undervoltage" },
|
||||
{ AlarmMessageType_t::ALL, 221, "PV-4: Input overvoltage" },
|
||||
{ AlarmMessageType_t::HMT, 221, "Abnormal wiring of grid neutral line" },
|
||||
{ AlarmMessageType_t::ALL, 222, "PV-4: Input undervoltage" },
|
||||
{ AlarmMessageType_t::ALL, 301, "Hardware error code 301" },
|
||||
{ AlarmMessageType_t::ALL, 302, "Hardware error code 302" },
|
||||
{ AlarmMessageType_t::ALL, 303, "Hardware error code 303" },
|
||||
{ AlarmMessageType_t::ALL, 304, "Hardware error code 304" },
|
||||
{ AlarmMessageType_t::ALL, 305, "Hardware error code 305" },
|
||||
{ AlarmMessageType_t::ALL, 306, "Hardware error code 306" },
|
||||
{ AlarmMessageType_t::ALL, 307, "Hardware error code 307" },
|
||||
{ AlarmMessageType_t::ALL, 308, "Hardware error code 308" },
|
||||
{ AlarmMessageType_t::ALL, 309, "Hardware error code 309" },
|
||||
{ AlarmMessageType_t::ALL, 310, "Hardware error code 310" },
|
||||
{ AlarmMessageType_t::ALL, 311, "Hardware error code 311" },
|
||||
{ AlarmMessageType_t::ALL, 312, "Hardware error code 312" },
|
||||
{ AlarmMessageType_t::ALL, 313, "Hardware error code 313" },
|
||||
{ AlarmMessageType_t::ALL, 314, "Hardware error code 314" },
|
||||
{ AlarmMessageType_t::ALL, 5041, "Error code-04 Port 1" },
|
||||
{ AlarmMessageType_t::ALL, 5042, "Error code-04 Port 2" },
|
||||
{ AlarmMessageType_t::ALL, 5043, "Error code-04 Port 3" },
|
||||
{ AlarmMessageType_t::ALL, 5044, "Error code-04 Port 4" },
|
||||
{ AlarmMessageType_t::ALL, 5051, "PV Input 1 Overvoltage/Undervoltage" },
|
||||
{ AlarmMessageType_t::ALL, 5052, "PV Input 2 Overvoltage/Undervoltage" },
|
||||
{ AlarmMessageType_t::ALL, 5053, "PV Input 3 Overvoltage/Undervoltage" },
|
||||
{ AlarmMessageType_t::ALL, 5054, "PV Input 4 Overvoltage/Undervoltage" },
|
||||
{ AlarmMessageType_t::ALL, 5060, "Abnormal bias" },
|
||||
{ AlarmMessageType_t::ALL, 5070, "Over temperature protection" },
|
||||
{ AlarmMessageType_t::ALL, 5080, "Grid Overvoltage/Undervoltage" },
|
||||
{ AlarmMessageType_t::ALL, 5090, "Grid Overfrequency/Underfrequency" },
|
||||
{ AlarmMessageType_t::ALL, 5100, "Island detected" },
|
||||
{ AlarmMessageType_t::ALL, 5120, "EEPROM reading and writing error" },
|
||||
{ AlarmMessageType_t::ALL, 5150, "10 min value grid overvoltage" },
|
||||
{ AlarmMessageType_t::ALL, 5200, "Firmware error" },
|
||||
{ AlarmMessageType_t::ALL, 8310, "Shut down" },
|
||||
{ AlarmMessageType_t::ALL, 9000, "Microinverter is suspected of being stolen" },
|
||||
};
|
||||
|
||||
void AlarmLogParser::clearBuffer()
|
||||
{
|
||||
memset(_payloadAlarmLog, 0, ALARM_LOG_PAYLOAD_SIZE);
|
||||
@ -37,6 +116,11 @@ LastCommandSuccess AlarmLogParser::getLastAlarmRequestSuccess()
|
||||
return _lastAlarmRequestSuccess;
|
||||
}
|
||||
|
||||
void AlarmLogParser::setMessageType(AlarmMessageType_t type)
|
||||
{
|
||||
_messageType = type;
|
||||
}
|
||||
|
||||
void AlarmLogParser::getLogEntry(uint8_t entryId, AlarmLogEntry_t* entry)
|
||||
{
|
||||
uint8_t entryStartOffset = 2 + entryId * ALARM_LOG_ENTRY_SIZE;
|
||||
@ -62,217 +146,16 @@ void AlarmLogParser::getLogEntry(uint8_t entryId, AlarmLogEntry_t* entry)
|
||||
entry->EndTime += (endTimeOffset + timezoneOffset);
|
||||
}
|
||||
|
||||
switch (entry->MessageId) {
|
||||
case 1:
|
||||
entry->Message = "Inverter start";
|
||||
break;
|
||||
case 2:
|
||||
entry->Message = "DTU command failed";
|
||||
break;
|
||||
case 121:
|
||||
entry->Message = "Over temperature protection";
|
||||
break;
|
||||
case 124:
|
||||
entry->Message = "Shut down by remote control";
|
||||
break;
|
||||
case 125:
|
||||
entry->Message = "Grid configuration parameter error";
|
||||
break;
|
||||
case 126:
|
||||
entry->Message = "Software error code 126";
|
||||
break;
|
||||
case 127:
|
||||
entry->Message = "Firmware error";
|
||||
break;
|
||||
case 128:
|
||||
entry->Message = "Software error code 128";
|
||||
break;
|
||||
case 129:
|
||||
entry->Message = "Abnormal bias";
|
||||
break;
|
||||
case 130:
|
||||
entry->Message = "Offline";
|
||||
break;
|
||||
case 141:
|
||||
entry->Message = "Grid: Grid overvoltage";
|
||||
break;
|
||||
case 142:
|
||||
entry->Message = "Grid: 10 min value grid overvoltage";
|
||||
break;
|
||||
case 143:
|
||||
entry->Message = "Grid: Grid undervoltage";
|
||||
break;
|
||||
case 144:
|
||||
entry->Message = "Grid: Grid overfrequency";
|
||||
break;
|
||||
case 145:
|
||||
entry->Message = "Grid: Grid underfrequency";
|
||||
break;
|
||||
case 146:
|
||||
entry->Message = "Grid: Rapid grid frequency change rate";
|
||||
break;
|
||||
case 147:
|
||||
entry->Message = "Grid: Power grid outage";
|
||||
break;
|
||||
case 148:
|
||||
entry->Message = "Grid: Grid disconnection";
|
||||
break;
|
||||
case 149:
|
||||
entry->Message = "Grid: Island detected";
|
||||
break;
|
||||
case 205:
|
||||
entry->Message = "MPPT-A: Input overvoltage";
|
||||
break;
|
||||
case 206:
|
||||
entry->Message = "MPPT-B: Input overvoltage";
|
||||
break;
|
||||
case 207:
|
||||
entry->Message = "MPPT-A: Input undervoltage";
|
||||
break;
|
||||
case 208:
|
||||
entry->Message = "MPPT-B: Input undervoltage";
|
||||
break;
|
||||
case 209:
|
||||
entry->Message = "PV-1: No input";
|
||||
break;
|
||||
case 210:
|
||||
entry->Message = "PV-2: No input";
|
||||
break;
|
||||
case 211:
|
||||
entry->Message = "PV-3: No input";
|
||||
break;
|
||||
case 212:
|
||||
entry->Message = "PV-4: No input";
|
||||
break;
|
||||
case 213:
|
||||
entry->Message = "MPPT-A: PV-1 & PV-2 abnormal wiring";
|
||||
break;
|
||||
case 214:
|
||||
entry->Message = "MPPT-B: PV-3 & PV-4 abnormal wiring";
|
||||
break;
|
||||
case 215:
|
||||
entry->Message = "PV-1: Input overvoltage";
|
||||
break;
|
||||
case 216:
|
||||
entry->Message = "PV-1: Input undervoltage";
|
||||
break;
|
||||
case 217:
|
||||
entry->Message = "PV-2: Input overvoltage";
|
||||
break;
|
||||
case 218:
|
||||
entry->Message = "PV-2: Input undervoltage";
|
||||
break;
|
||||
case 219:
|
||||
entry->Message = "PV-3: Input overvoltage";
|
||||
break;
|
||||
case 220:
|
||||
entry->Message = "PV-3: Input undervoltage";
|
||||
break;
|
||||
case 221:
|
||||
entry->Message = "PV-4: Input overvoltage";
|
||||
break;
|
||||
case 222:
|
||||
entry->Message = "PV-4: Input undervoltage";
|
||||
break;
|
||||
case 301:
|
||||
entry->Message = "Hardware error code 301";
|
||||
break;
|
||||
case 302:
|
||||
entry->Message = "Hardware error code 302";
|
||||
break;
|
||||
case 303:
|
||||
entry->Message = "Hardware error code 303";
|
||||
break;
|
||||
case 304:
|
||||
entry->Message = "Hardware error code 304";
|
||||
break;
|
||||
case 305:
|
||||
entry->Message = "Hardware error code 305";
|
||||
break;
|
||||
case 306:
|
||||
entry->Message = "Hardware error code 306";
|
||||
break;
|
||||
case 307:
|
||||
entry->Message = "Hardware error code 307";
|
||||
break;
|
||||
case 308:
|
||||
entry->Message = "Hardware error code 308";
|
||||
break;
|
||||
case 309:
|
||||
entry->Message = "Hardware error code 309";
|
||||
break;
|
||||
case 310:
|
||||
entry->Message = "Hardware error code 310";
|
||||
break;
|
||||
case 311:
|
||||
entry->Message = "Hardware error code 311";
|
||||
break;
|
||||
case 312:
|
||||
entry->Message = "Hardware error code 312";
|
||||
break;
|
||||
case 313:
|
||||
entry->Message = "Hardware error code 313";
|
||||
break;
|
||||
case 314:
|
||||
entry->Message = "Hardware error code 314";
|
||||
break;
|
||||
case 5041:
|
||||
entry->Message = "Error code-04 Port 1";
|
||||
break;
|
||||
case 5042:
|
||||
entry->Message = "Error code-04 Port 2";
|
||||
break;
|
||||
case 5043:
|
||||
entry->Message = "Error code-04 Port 3";
|
||||
break;
|
||||
case 5044:
|
||||
entry->Message = "Error code-04 Port 4";
|
||||
break;
|
||||
case 5051:
|
||||
entry->Message = "PV Input 1 Overvoltage/Undervoltage";
|
||||
break;
|
||||
case 5052:
|
||||
entry->Message = "PV Input 2 Overvoltage/Undervoltage";
|
||||
break;
|
||||
case 5053:
|
||||
entry->Message = "PV Input 3 Overvoltage/Undervoltage";
|
||||
break;
|
||||
case 5054:
|
||||
entry->Message = "PV Input 4 Overvoltage/Undervoltage";
|
||||
break;
|
||||
case 5060:
|
||||
entry->Message = "Abnormal bias";
|
||||
break;
|
||||
case 5070:
|
||||
entry->Message = "Over temperature protection";
|
||||
break;
|
||||
case 5080:
|
||||
entry->Message = "Grid Overvoltage/Undervoltage";
|
||||
break;
|
||||
case 5090:
|
||||
entry->Message = "Grid Overfrequency/Underfrequency";
|
||||
break;
|
||||
case 5100:
|
||||
entry->Message = "Island detected";
|
||||
break;
|
||||
case 5120:
|
||||
entry->Message = "EEPROM reading and writing error";
|
||||
break;
|
||||
case 5150:
|
||||
entry->Message = "10 min value grid overvoltage";
|
||||
break;
|
||||
case 5200:
|
||||
entry->Message = "Firmware error";
|
||||
break;
|
||||
case 8310:
|
||||
entry->Message = "Shut down";
|
||||
break;
|
||||
case 9000:
|
||||
entry->Message = "Microinverter is suspected of being stolen";
|
||||
break;
|
||||
default:
|
||||
entry->Message = "Unknown";
|
||||
break;
|
||||
entry->Message = "Unknown";
|
||||
for (auto& msg : _alarmMessages) {
|
||||
if (msg.MessageId == entry->MessageId) {
|
||||
if (msg.InverterType == _messageType) {
|
||||
entry->Message = msg.Message;
|
||||
break;
|
||||
} else if (msg.InverterType == AlarmMessageType_t::ALL) {
|
||||
entry->Message = msg.Message;
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
@ -1,8 +1,9 @@
|
||||
// SPDX-License-Identifier: GPL-2.0-or-later
|
||||
#pragma once
|
||||
#include "Parser.h"
|
||||
#include <cstdint>
|
||||
#include <Arduino.h>
|
||||
#include <cstdint>
|
||||
#include <list>
|
||||
|
||||
#define ALARM_LOG_ENTRY_COUNT 15
|
||||
#define ALARM_LOG_ENTRY_SIZE 12
|
||||
@ -15,6 +16,17 @@ struct AlarmLogEntry_t {
|
||||
time_t EndTime;
|
||||
};
|
||||
|
||||
enum class AlarmMessageType_t {
|
||||
ALL = 0,
|
||||
HMT
|
||||
};
|
||||
|
||||
typedef struct {
|
||||
AlarmMessageType_t InverterType;
|
||||
uint16_t MessageId;
|
||||
String Message;
|
||||
} AlarmMessage_t;
|
||||
|
||||
class AlarmLogParser : public Parser {
|
||||
public:
|
||||
void clearBuffer();
|
||||
@ -26,6 +38,8 @@ public:
|
||||
void setLastAlarmRequestSuccess(LastCommandSuccess status);
|
||||
LastCommandSuccess getLastAlarmRequestSuccess();
|
||||
|
||||
void setMessageType(AlarmMessageType_t type);
|
||||
|
||||
private:
|
||||
static int getTimezoneOffset();
|
||||
|
||||
@ -33,4 +47,8 @@ private:
|
||||
uint8_t _alarmLogLength;
|
||||
|
||||
LastCommandSuccess _lastAlarmRequestSuccess = CMD_NOK; // Set to NOK to fetch at startup
|
||||
|
||||
AlarmMessageType_t _messageType = AlarmMessageType_t::ALL;
|
||||
|
||||
static const std::list<AlarmMessage_t> _alarmMessages;
|
||||
};
|
||||
Loading…
Reference in New Issue