Use the new data store in the graphic display class.
With this patch, the display turns off if no inverter is reachable anymore. Previously it turned off if the production was zero. This fixes #933
This commit is contained in:
parent
cd98941c5d
commit
40820c07f2
@ -1,6 +1,6 @@
|
|||||||
// SPDX-License-Identifier: GPL-2.0-or-later
|
// SPDX-License-Identifier: GPL-2.0-or-later
|
||||||
#include "Display_Graphic.h"
|
#include "Display_Graphic.h"
|
||||||
#include <Hoymiles.h>
|
#include "Datastore.h"
|
||||||
#include <NetworkSettings.h>
|
#include <NetworkSettings.h>
|
||||||
#include <map>
|
#include <map>
|
||||||
#include <time.h>
|
#include <time.h>
|
||||||
@ -113,38 +113,16 @@ void DisplayGraphicClass::loop()
|
|||||||
}
|
}
|
||||||
|
|
||||||
if ((millis() - _lastDisplayUpdate) > _period) {
|
if ((millis() - _lastDisplayUpdate) > _period) {
|
||||||
float totalPower = 0;
|
|
||||||
float totalYieldDay = 0;
|
|
||||||
float totalYieldTotal = 0;
|
|
||||||
|
|
||||||
uint8_t isprod = 0;
|
|
||||||
|
|
||||||
for (uint8_t i = 0; i < Hoymiles.getNumInverters(); i++) {
|
|
||||||
auto inv = Hoymiles.getInverterByPos(i);
|
|
||||||
if (inv == nullptr) {
|
|
||||||
continue;
|
|
||||||
}
|
|
||||||
|
|
||||||
if (inv->isProducing()) {
|
|
||||||
isprod++;
|
|
||||||
}
|
|
||||||
|
|
||||||
for (auto& c : inv->Statistics()->getChannelsByType(TYPE_AC)) {
|
|
||||||
totalPower += inv->Statistics()->getChannelFieldValue(TYPE_AC, c, FLD_PAC);
|
|
||||||
totalYieldDay += inv->Statistics()->getChannelFieldValue(TYPE_AC, c, FLD_YD);
|
|
||||||
totalYieldTotal += inv->Statistics()->getChannelFieldValue(TYPE_AC, c, FLD_YT);
|
|
||||||
}
|
|
||||||
}
|
|
||||||
|
|
||||||
_display->clearBuffer();
|
_display->clearBuffer();
|
||||||
|
|
||||||
//=====> Actual Production ==========
|
//=====> Actual Production ==========
|
||||||
if ((totalPower > 0) && (isprod > 0)) {
|
if (Datastore.isAtLeastOneReachable) {
|
||||||
_display->setPowerSave(false);
|
_display->setPowerSave(false);
|
||||||
if (totalPower > 999) {
|
if (Datastore.totalAcPowerEnabled > 999) {
|
||||||
snprintf(_fmtText, sizeof(_fmtText), "%2.1f kW", (totalPower / 1000));
|
snprintf(_fmtText, sizeof(_fmtText), "%2.1f kW", (Datastore.totalAcPowerEnabled / 1000));
|
||||||
} else {
|
} else {
|
||||||
snprintf(_fmtText, sizeof(_fmtText), "%3.0f W", totalPower);
|
snprintf(_fmtText, sizeof(_fmtText), "%3.0f W", Datastore.totalAcPowerEnabled);
|
||||||
}
|
}
|
||||||
printText(_fmtText, 0);
|
printText(_fmtText, 0);
|
||||||
_previousMillis = millis();
|
_previousMillis = millis();
|
||||||
@ -162,10 +140,10 @@ void DisplayGraphicClass::loop()
|
|||||||
//<=======================
|
//<=======================
|
||||||
|
|
||||||
//=====> Today & Total Production =======
|
//=====> Today & Total Production =======
|
||||||
snprintf(_fmtText, sizeof(_fmtText), "today: %4.0f Wh", totalYieldDay);
|
snprintf(_fmtText, sizeof(_fmtText), "today: %4.0f Wh", Datastore.totalAcYieldDayEnabled);
|
||||||
printText(_fmtText, 1);
|
printText(_fmtText, 1);
|
||||||
|
|
||||||
snprintf(_fmtText, sizeof(_fmtText), "total: %.1f kWh", totalYieldTotal);
|
snprintf(_fmtText, sizeof(_fmtText), "total: %.1f kWh", Datastore.totalAcYieldTotalEnabled);
|
||||||
printText(_fmtText, 2);
|
printText(_fmtText, 2);
|
||||||
//<=======================
|
//<=======================
|
||||||
|
|
||||||
|
|||||||