// SPDX-License-Identifier: GPL-2.0-or-later
|
|
/*
|
|
* Copyright (C) 2022 Thomas Basler and others
|
|
*/
|
|
|
|
#include "Battery.h"
|
|
#include "PowerMeter.h"
|
|
#include "PowerLimiter.h"
|
|
#include "Configuration.h"
|
|
#include "MqttSettings.h"
|
|
#include "NetworkSettings.h"
|
|
#include <VeDirectFrameHandler.h>
|
|
#include "MessageOutput.h"
|
|
#include <ctime>
|
|
#include <cmath>
|
|
#include <map>
|
|
|
|
PowerLimiterClass PowerLimiter;
|
|
|
|
#define POWER_LIMITER_DEBUG
|
|
|
|
void PowerLimiterClass::init() { }
|
|
|
|
std::string const& PowerLimiterClass::getStatusText(PowerLimiterClass::Status status)
|
|
{
|
|
static const std::string missing = "programmer error: missing status text";
|
|
|
|
static const std::map<Status, const std::string> texts = {
|
|
{ Status::Initializing, "initializing (should not see me)" },
|
|
{ Status::DisabledByConfig, "disabled by configuration" },
|
|
{ Status::DisabledByMqtt, "disabled by MQTT" },
|
|
{ Status::PowerMeterDisabled, "no power meter is configured/enabled" },
|
|
{ Status::PowerMeterTimeout, "power meter readings are outdated" },
|
|
{ Status::PowerMeterPending, "waiting for sufficiently recent power meter reading" },
|
|
{ Status::InverterInvalid, "invalid inverter selection/configuration" },
|
|
{ Status::InverterChanged, "target inverter changed" },
|
|
{ Status::InverterOffline, "inverter is offline (polling enabled? radio okay?)" },
|
|
{ Status::InverterCommandsDisabled, "inverter configuration prohibits sending commands" },
|
|
{ Status::InverterLimitPending, "waiting for a power limit command to complete" },
|
|
{ Status::InverterPowerCmdPending, "waiting for a start/stop/restart command to complete" },
|
|
{ Status::InverterStatsPending, "waiting for sufficiently recent inverter data" },
|
|
{ Status::UnconditionalSolarPassthrough, "unconditionally passing through all solar power (MQTT override)" },
|
|
{ Status::NoVeDirect, "VE.Direct disabled, connection broken, or data outdated" },
|
|
{ Status::Settling, "waiting for the system to settle" },
|
|
{ Status::Stable, "the system is stable, the last power limit is still valid" },
|
|
{ Status::LowerLimitUndercut, "calculated power limit undercuts configured lower limit" }
|
|
};
|
|
|
|
auto iter = texts.find(status);
|
|
if (iter == texts.end()) { return missing; }
|
|
|
|
return iter->second;
|
|
}
|
|
|
|
void PowerLimiterClass::announceStatus(PowerLimiterClass::Status status)
|
|
{
|
|
// this method is called with high frequency. print the status text if
|
|
// the status changed since we last printed the text of another one.
|
|
// otherwise repeat the info with a fixed interval.
|
|
if (_lastStatus == status && millis() < _lastStatusPrinted + 10 * 1000) { return; }
|
|
|
|
// after announcing once that the DPL is disabled by configuration, it
|
|
// should just be silent while it is disabled.
|
|
if (status == Status::DisabledByConfig && _lastStatus == status) { return; }
|
|
|
|
MessageOutput.printf("[%11.3f] DPL: %s\r\n",
|
|
static_cast<double>(millis())/1000, getStatusText(status).c_str());
|
|
|
|
_lastStatus = status;
|
|
_lastStatusPrinted = millis();
|
|
}
|
|
|
|
void PowerLimiterClass::shutdown(PowerLimiterClass::Status status)
|
|
{
|
|
announceStatus(status);
|
|
|
|
if (_inverter == nullptr || !_inverter->isProducing() || !_inverter->isReachable()) {
|
|
_inverter = nullptr;
|
|
_shutdownInProgress = false;
|
|
return;
|
|
}
|
|
|
|
_shutdownInProgress = true;
|
|
|
|
auto lastLimitCommandState = _inverter->SystemConfigPara()->getLastLimitCommandSuccess();
|
|
if (CMD_PENDING == lastLimitCommandState) { return; }
|
|
|
|
auto lastPowerCommandState = _inverter->PowerCommand()->getLastPowerCommandSuccess();
|
|
if (CMD_PENDING == lastPowerCommandState) { return; }
|
|
|
|
CONFIG_T& config = Configuration.get();
|
|
commitPowerLimit(_inverter, config.PowerLimiter_LowerPowerLimit, false);
|
|
}
|
|
|
|
void PowerLimiterClass::loop()
|
|
{
|
|
CONFIG_T& config = Configuration.get();
|
|
|
|
if (_shutdownInProgress) {
|
|
// we transition from SHUTDOWN to OFF when we know the inverter was
|
|
// shut down. until then, we retry shutting it down. in this case we
|
|
// preserve the original status that lead to the decision to shut down.
|
|
return shutdown(_lastStatus);
|
|
}
|
|
|
|
if (!config.PowerLimiter_Enabled) {
|
|
return shutdown(Status::DisabledByConfig);
|
|
}
|
|
|
|
if (PL_MODE_FULL_DISABLE == _mode) {
|
|
return shutdown(Status::DisabledByMqtt);
|
|
}
|
|
|
|
std::shared_ptr<InverterAbstract> currentInverter =
|
|
Hoymiles.getInverterByPos(config.PowerLimiter_InverterId);
|
|
|
|
// in case of (newly) broken configuration, shut down
|
|
// the last inverter we worked with (if any)
|
|
if (currentInverter == nullptr) {
|
|
return shutdown(Status::InverterInvalid);
|
|
}
|
|
|
|
// if the DPL is supposed to manage another inverter now, we first
|
|
// shut down the previous one, if any. then we pick up the new one.
|
|
if (_inverter != nullptr && _inverter->serial() != currentInverter->serial()) {
|
|
return shutdown(Status::InverterChanged);
|
|
}
|
|
|
|
// update our pointer as the configuration might have changed
|
|
_inverter = currentInverter;
|
|
|
|
// data polling is disabled or the inverter is deemed offline
|
|
if (!_inverter->isReachable()) {
|
|
return announceStatus(Status::InverterOffline);
|
|
}
|
|
|
|
// sending commands to the inverter is disabled
|
|
if (!_inverter->getEnableCommands()) {
|
|
return announceStatus(Status::InverterCommandsDisabled);
|
|
}
|
|
|
|
// concerns active power commands (power limits) only (also from web app or MQTT)
|
|
auto lastLimitCommandState = _inverter->SystemConfigPara()->getLastLimitCommandSuccess();
|
|
if (CMD_PENDING == lastLimitCommandState) {
|
|
return announceStatus(Status::InverterLimitPending);
|
|
}
|
|
|
|
// concerns power commands (start, stop, restart) only (also from web app or MQTT)
|
|
auto lastPowerCommandState = _inverter->PowerCommand()->getLastPowerCommandSuccess();
|
|
if (CMD_PENDING == lastPowerCommandState) {
|
|
return announceStatus(Status::InverterPowerCmdPending);
|
|
}
|
|
|
|
if (PL_MODE_SOLAR_PT_ONLY == _mode) {
|
|
// handle this mode of operation separately
|
|
return unconditionalSolarPassthrough(_inverter);
|
|
}
|
|
|
|
// the normal mode of operation requires a valid
|
|
// power meter reading to calculate a power limit
|
|
if (!config.PowerMeter_Enabled) {
|
|
return shutdown(Status::PowerMeterDisabled);
|
|
}
|
|
|
|
if (millis() - PowerMeter.getLastPowerMeterUpdate() > (30 * 1000)) {
|
|
return shutdown(Status::PowerMeterTimeout);
|
|
}
|
|
|
|
// concerns both power limits and start/stop/restart commands and is
|
|
// only updated if a respective response was received from the inverter
|
|
auto lastUpdateCmd = std::max(
|
|
_inverter->SystemConfigPara()->getLastUpdateCommand(),
|
|
_inverter->PowerCommand()->getLastUpdateCommand());
|
|
|
|
// wait for power meter and inverter stat updates after a settling phase
|
|
auto settlingEnd = lastUpdateCmd + 3 * 1000;
|
|
|
|
if (millis() < settlingEnd) { return announceStatus(Status::Settling); }
|
|
|
|
if (_inverter->Statistics()->getLastUpdate() <= settlingEnd) {
|
|
return announceStatus(Status::InverterStatsPending);
|
|
}
|
|
|
|
if (PowerMeter.getLastPowerMeterUpdate() <= settlingEnd) {
|
|
return announceStatus(Status::PowerMeterPending);
|
|
}
|
|
|
|
// since _lastCalculation and _calculationBackoffMs are initialized to
|
|
// zero, this test is passed the first time the condition is checked.
|
|
if (millis() < (_lastCalculation + _calculationBackoffMs)) {
|
|
return announceStatus(Status::Stable);
|
|
}
|
|
|
|
#ifdef POWER_LIMITER_DEBUG
|
|
MessageOutput.println("[PowerLimiterClass::loop] ******************* ENTER **********************");
|
|
#endif
|
|
|
|
// Check if next inverter restart time is reached
|
|
if ((_nextInverterRestart > 1) && (_nextInverterRestart <= millis())) {
|
|
MessageOutput.println("[PowerLimiterClass::loop] send inverter restart");
|
|
_inverter->sendRestartControlRequest();
|
|
calcNextInverterRestart();
|
|
}
|
|
|
|
// Check if NTP time is set and next inverter restart not calculated yet
|
|
if ((config.PowerLimiter_RestartHour >= 0) && (_nextInverterRestart == 0) ) {
|
|
// check every 5 seconds
|
|
if (_nextCalculateCheck < millis()) {
|
|
struct tm timeinfo;
|
|
if (getLocalTime(&timeinfo, 5)) {
|
|
calcNextInverterRestart();
|
|
} else {
|
|
MessageOutput.println("[PowerLimiterClass::loop] inverter restart calculation: NTP not ready");
|
|
_nextCalculateCheck += 5000;
|
|
}
|
|
}
|
|
}
|
|
|
|
// Printout some stats
|
|
if (millis() - PowerMeter.getLastPowerMeterUpdate() < (30 * 1000)) {
|
|
float dcVoltage = _inverter->Statistics()->getChannelFieldValue(TYPE_DC, (ChannelNum_t) config.PowerLimiter_InverterChannelId, FLD_UDC);
|
|
MessageOutput.printf("[PowerLimiterClass::loop] dcVoltage: %.2f Voltage Start Threshold: %.2f Voltage Stop Threshold: %.2f inverter->isProducing(): %d\r\n",
|
|
dcVoltage, config.PowerLimiter_VoltageStartThreshold, config.PowerLimiter_VoltageStopThreshold, _inverter->isProducing());
|
|
}
|
|
|
|
// Battery charging cycle conditions
|
|
// First we always disable discharge if the battery is empty
|
|
if (isStopThresholdReached(_inverter)) {
|
|
// Disable battery discharge when empty
|
|
_batteryDischargeEnabled = false;
|
|
} else {
|
|
// UI: Solar Passthrough Enabled -> false
|
|
// Battery discharge can be enabled when start threshold is reached
|
|
if (!config.PowerLimiter_SolarPassThroughEnabled && isStartThresholdReached(_inverter)) {
|
|
_batteryDischargeEnabled = true;
|
|
}
|
|
|
|
// UI: Solar Passthrough Enabled -> true && EMPTY_AT_NIGHT
|
|
if (config.PowerLimiter_SolarPassThroughEnabled && config.PowerLimiter_BatteryDrainStategy == EMPTY_AT_NIGHT) {
|
|
if(isStartThresholdReached(_inverter)) {
|
|
// In this case we should only discharge the battery as long it is above startThreshold
|
|
_batteryDischargeEnabled = true;
|
|
}
|
|
else {
|
|
// In this case we should only discharge the battery when there is no sunshine
|
|
_batteryDischargeEnabled = !canUseDirectSolarPower();
|
|
}
|
|
}
|
|
|
|
// UI: Solar Passthrough Enabled -> true && EMPTY_WHEN_FULL
|
|
// Battery discharge can be enabled when start threshold is reached
|
|
if (config.PowerLimiter_SolarPassThroughEnabled && isStartThresholdReached(_inverter) && config.PowerLimiter_BatteryDrainStategy == EMPTY_WHEN_FULL) {
|
|
_batteryDischargeEnabled = true;
|
|
}
|
|
}
|
|
// Calculate and set Power Limit
|
|
int32_t newPowerLimit = calcPowerLimit(_inverter, canUseDirectSolarPower(), _batteryDischargeEnabled);
|
|
bool limitUpdated = setNewPowerLimit(_inverter, newPowerLimit);
|
|
#ifdef POWER_LIMITER_DEBUG
|
|
MessageOutput.printf("[PowerLimiterClass::loop] Status: SolarPT enabled %i, Drain Strategy: %i, canUseDirectSolarPower: %i, Batt discharge: %i\r\n",
|
|
config.PowerLimiter_SolarPassThroughEnabled, config.PowerLimiter_BatteryDrainStategy, canUseDirectSolarPower(), _batteryDischargeEnabled);
|
|
MessageOutput.printf("[PowerLimiterClass::loop] Status: StartTH %i, StopTH: %i, loadCorrectedV %f\r\n",
|
|
isStartThresholdReached(_inverter), isStopThresholdReached(_inverter), getLoadCorrectedVoltage(_inverter));
|
|
MessageOutput.printf("[PowerLimiterClass::loop] Status Batt: Ena: %i, SOC: %i, StartTH: %i, StopTH: %i, LastUpdate: %li\r\n",
|
|
config.Battery_Enabled, Battery.stateOfCharge, config.PowerLimiter_BatterySocStartThreshold, config.PowerLimiter_BatterySocStopThreshold, millis() - Battery.stateOfChargeLastUpdate);
|
|
MessageOutput.printf("[PowerLimiterClass::loop] ******************* Leaving PL, PL set to: %i, SP: %i, Batt: %i, PM: %f\r\n", newPowerLimit, canUseDirectSolarPower(), _batteryDischargeEnabled, round(PowerMeter.getPowerTotal()));
|
|
#endif
|
|
|
|
_lastCalculation = millis();
|
|
|
|
if (!limitUpdated) {
|
|
// increase polling backoff if system seems to be stable
|
|
_calculationBackoffMs = std::min<uint32_t>(1024, _calculationBackoffMs * 2);
|
|
return announceStatus(Status::Stable);
|
|
}
|
|
|
|
_calculationBackoffMs = 128;
|
|
}
|
|
|
|
/**
|
|
* calculate the AC output power (limit) to set, such that the inverter uses
|
|
* the given power on its DC side, i.e., adjust the power for the inverter's
|
|
* efficiency.
|
|
*/
|
|
int32_t PowerLimiterClass::inverterPowerDcToAc(std::shared_ptr<InverterAbstract> inverter, int32_t dcPower)
|
|
{
|
|
CONFIG_T& config = Configuration.get();
|
|
|
|
float inverterEfficiencyPercent = inverter->Statistics()->getChannelFieldValue(
|
|
TYPE_AC, static_cast<ChannelNum_t>(config.PowerLimiter_InverterChannelId), FLD_EFF);
|
|
|
|
// fall back to hoymiles peak efficiency as per datasheet if inverter
|
|
// is currently not producing (efficiency is zero in that case)
|
|
float inverterEfficiencyFactor = (inverterEfficiencyPercent > 0) ? inverterEfficiencyPercent/100 : 0.967;
|
|
|
|
return dcPower * inverterEfficiencyFactor;
|
|
}
|
|
|
|
/**
|
|
* implements the "unconditional solar passthrough" mode of operation, which
|
|
* can currently only be set using MQTT. in this mode of operation, the
|
|
* inverter shall behave as if it was connected to the solar panels directly,
|
|
* i.e., all solar power (and only solar power) is fed to the AC side,
|
|
* independent from the power meter reading.
|
|
*/
|
|
void PowerLimiterClass::unconditionalSolarPassthrough(std::shared_ptr<InverterAbstract> inverter)
|
|
{
|
|
CONFIG_T& config = Configuration.get();
|
|
|
|
if (!config.Vedirect_Enabled || !VeDirect.isDataValid()) {
|
|
return shutdown(Status::NoVeDirect);
|
|
}
|
|
|
|
int32_t solarPower = VeDirect.veFrame.V * VeDirect.veFrame.I;
|
|
setNewPowerLimit(inverter, inverterPowerDcToAc(inverter, solarPower));
|
|
announceStatus(Status::UnconditionalSolarPassthrough);
|
|
}
|
|
|
|
uint8_t PowerLimiterClass::getPowerLimiterState() {
|
|
if (_inverter == nullptr || !_inverter->isReachable()) {
|
|
return PL_UI_STATE_INACTIVE;
|
|
}
|
|
|
|
if (_inverter->isProducing() && _batteryDischargeEnabled) {
|
|
return PL_UI_STATE_USE_SOLAR_AND_BATTERY;
|
|
}
|
|
|
|
if (_inverter->isProducing() && !_batteryDischargeEnabled) {
|
|
return PL_UI_STATE_USE_SOLAR_ONLY;
|
|
}
|
|
|
|
if(!_inverter->isProducing()) {
|
|
return PL_UI_STATE_CHARGING;
|
|
}
|
|
|
|
return PL_UI_STATE_INACTIVE;
|
|
}
|
|
|
|
int32_t PowerLimiterClass::getLastRequestedPowerLimit() {
|
|
return _lastRequestedPowerLimit;
|
|
}
|
|
|
|
bool PowerLimiterClass::getMode() {
|
|
return _mode;
|
|
}
|
|
|
|
void PowerLimiterClass::setMode(uint8_t mode) {
|
|
_mode = mode;
|
|
}
|
|
|
|
bool PowerLimiterClass::canUseDirectSolarPower()
|
|
{
|
|
CONFIG_T& config = Configuration.get();
|
|
|
|
if (!config.PowerLimiter_SolarPassThroughEnabled
|
|
|| !config.Vedirect_Enabled
|
|
|| !VeDirect.isDataValid()) {
|
|
return false;
|
|
}
|
|
|
|
return VeDirect.veFrame.PPV >= 20; // enough power?
|
|
}
|
|
|
|
|
|
// Logic table
|
|
// | Case # | batteryDischargeEnabled | solarPowerEnabled | useFullSolarPassthrough | Result |
|
|
// | 1 | false | false | doesn't matter | PL = 0 |
|
|
// | 2 | false | true | doesn't matter | PL = Victron Power |
|
|
// | 3 | true | doesn't matter | false | PL = PowerMeter value (Battery can supply unlimited energy) |
|
|
// | 4 | true | false | true | PL = PowerMeter value |
|
|
// | 5 | true | true | true | PL = max(PowerMeter value, Victron Power) |
|
|
|
|
int32_t PowerLimiterClass::calcPowerLimit(std::shared_ptr<InverterAbstract> inverter, bool solarPowerEnabled, bool batteryDischargeEnabled)
|
|
{
|
|
CONFIG_T& config = Configuration.get();
|
|
|
|
int32_t acPower = 0;
|
|
int32_t newPowerLimit = round(PowerMeter.getPowerTotal());
|
|
|
|
if (!solarPowerEnabled && !batteryDischargeEnabled) {
|
|
// Case 1 - No energy sources available
|
|
return 0;
|
|
}
|
|
|
|
if (config.PowerLimiter_IsInverterBehindPowerMeter) {
|
|
// If the inverter the behind the power meter (part of measurement),
|
|
// the produced power of this inverter has also to be taken into account.
|
|
// We don't use FLD_PAC from the statistics, because that
|
|
// data might be too old and unreliable.
|
|
acPower = static_cast<int>(inverter->Statistics()->getChannelFieldValue(TYPE_AC, (ChannelNum_t) config.PowerLimiter_InverterChannelId, FLD_PAC));
|
|
newPowerLimit += acPower;
|
|
}
|
|
|
|
// We're not trying to hit 0 exactly but take an offset into account
|
|
// This means we never fully compensate the used power with the inverter
|
|
// Case 3
|
|
newPowerLimit -= config.PowerLimiter_TargetPowerConsumption;
|
|
|
|
// At this point we've calculated the required energy to compensate for household consumption.
|
|
// If the battery is enabled this can always be supplied since we assume that the battery can supply unlimited power
|
|
// The next step is to determine if the Solar power as provided by the Victron charger
|
|
// actually constrains or dictates another inverter power value
|
|
int32_t adjustedVictronChargePower = inverterPowerDcToAc(inverter, getSolarChargePower());
|
|
|
|
// Battery can be discharged and we should output max (Victron solar power || power meter value)
|
|
if(batteryDischargeEnabled && useFullSolarPassthrough(inverter)) {
|
|
// Case 5
|
|
newPowerLimit = newPowerLimit > adjustedVictronChargePower ? newPowerLimit : adjustedVictronChargePower;
|
|
}
|
|
|
|
// We should use Victron solar power only (corrected by efficiency factor)
|
|
if (solarPowerEnabled && !batteryDischargeEnabled) {
|
|
// Case 2 - Limit power to solar power only
|
|
MessageOutput.printf("[PowerLimiterClass::loop] Consuming Solar Power Only -> adjustedVictronChargePower: %d, powerConsumption: %d \r\n",
|
|
adjustedVictronChargePower, newPowerLimit);
|
|
|
|
newPowerLimit = std::min(newPowerLimit, adjustedVictronChargePower);
|
|
}
|
|
|
|
MessageOutput.printf("[PowerLimiterClass::loop] newPowerLimit: %d\r\n", newPowerLimit);
|
|
return newPowerLimit;
|
|
}
|
|
|
|
void PowerLimiterClass::commitPowerLimit(std::shared_ptr<InverterAbstract> inverter, int32_t limit, bool enablePowerProduction)
|
|
{
|
|
// disable power production as soon as possible.
|
|
// setting the power limit is less important.
|
|
if (!enablePowerProduction && inverter->isProducing()) {
|
|
MessageOutput.println("[PowerLimiterClass::commitPowerLimit] Stopping inverter...");
|
|
inverter->sendPowerControlRequest(false);
|
|
}
|
|
|
|
inverter->sendActivePowerControlRequest(static_cast<float>(limit),
|
|
PowerLimitControlType::AbsolutNonPersistent);
|
|
|
|
_lastRequestedPowerLimit = limit;
|
|
|
|
// enable power production only after setting the desired limit,
|
|
// such that an older, greater limit will not cause power spikes.
|
|
if (enablePowerProduction && !inverter->isProducing()) {
|
|
MessageOutput.println("[PowerLimiterClass::commitPowerLimit] Starting up inverter...");
|
|
inverter->sendPowerControlRequest(true);
|
|
}
|
|
}
|
|
|
|
/**
|
|
* enforces limits and a hystersis on the requested power limit, after scaling
|
|
* the power limit to the ratio of total and producing inverter channels.
|
|
* commits the sanitized power limit. returns true if a limit update was
|
|
* committed, false otherwise.
|
|
*/
|
|
bool PowerLimiterClass::setNewPowerLimit(std::shared_ptr<InverterAbstract> inverter, int32_t newPowerLimit)
|
|
{
|
|
CONFIG_T& config = Configuration.get();
|
|
|
|
// Stop the inverter if limit is below threshold.
|
|
if (newPowerLimit < config.PowerLimiter_LowerPowerLimit) {
|
|
shutdown(Status::LowerLimitUndercut);
|
|
return true;
|
|
}
|
|
|
|
// enforce configured upper power limit
|
|
int32_t effPowerLimit = std::min(newPowerLimit, config.PowerLimiter_UpperPowerLimit);
|
|
|
|
// scale the power limit by the amount of all inverter channels devided by
|
|
// the amount of producing inverter channels. the inverters limit each of
|
|
// the n channels to 1/n of the total power limit. scaling the power limit
|
|
// ensures the total inverter output is what we are asking for.
|
|
std::list<ChannelNum_t> dcChnls = inverter->Statistics()->getChannelsByType(TYPE_DC);
|
|
int dcProdChnls = 0, dcTotalChnls = dcChnls.size();
|
|
for (auto& c : dcChnls) {
|
|
if (inverter->Statistics()->getChannelFieldValue(TYPE_DC, c, FLD_PDC) > 1.0) {
|
|
dcProdChnls++;
|
|
}
|
|
}
|
|
if (dcProdChnls > 0) {
|
|
MessageOutput.printf("[PowerLimiterClass::setNewPowerLimit] %d channels total, %d producing channels, scaling power limit\r\n",
|
|
dcTotalChnls, dcProdChnls);
|
|
effPowerLimit = round(effPowerLimit * static_cast<float>(dcTotalChnls) / dcProdChnls);
|
|
if (effPowerLimit > inverter->DevInfo()->getMaxPower()) {
|
|
effPowerLimit = inverter->DevInfo()->getMaxPower();
|
|
}
|
|
}
|
|
|
|
// Check if the new value is within the limits of the hysteresis
|
|
auto diff = std::abs(effPowerLimit - _lastRequestedPowerLimit);
|
|
if ( diff < config.PowerLimiter_TargetPowerConsumptionHysteresis) {
|
|
MessageOutput.printf("[PowerLimiterClass::setNewPowerLimit] reusing old limit: %d W, diff: %d, hysteresis: %d\r\n",
|
|
_lastRequestedPowerLimit, diff, config.PowerLimiter_TargetPowerConsumptionHysteresis);
|
|
return false;
|
|
}
|
|
|
|
MessageOutput.printf("[PowerLimiterClass::setNewPowerLimit] using new limit: %d W, requested power limit: %d\r\n",
|
|
effPowerLimit, newPowerLimit);
|
|
|
|
commitPowerLimit(inverter, effPowerLimit, true);
|
|
return true;
|
|
}
|
|
|
|
int32_t PowerLimiterClass::getSolarChargePower()
|
|
{
|
|
if (!canUseDirectSolarPower()) {
|
|
return 0;
|
|
}
|
|
|
|
return VeDirect.veFrame.V * VeDirect.veFrame.I;
|
|
}
|
|
|
|
float PowerLimiterClass::getLoadCorrectedVoltage(std::shared_ptr<InverterAbstract> inverter)
|
|
{
|
|
CONFIG_T& config = Configuration.get();
|
|
|
|
float acPower = inverter->Statistics()->getChannelFieldValue(TYPE_AC, (ChannelNum_t) config.PowerLimiter_InverterChannelId, FLD_PAC);
|
|
float dcVoltage = inverter->Statistics()->getChannelFieldValue(TYPE_DC, (ChannelNum_t) config.PowerLimiter_InverterChannelId, FLD_UDC);
|
|
|
|
if (dcVoltage <= 0.0) {
|
|
return 0.0;
|
|
}
|
|
|
|
return dcVoltage + (acPower * config.PowerLimiter_VoltageLoadCorrectionFactor);
|
|
}
|
|
|
|
bool PowerLimiterClass::isStartThresholdReached(std::shared_ptr<InverterAbstract> inverter)
|
|
{
|
|
CONFIG_T& config = Configuration.get();
|
|
|
|
// Check if the Battery interface is enabled and the SOC start threshold is reached
|
|
if (config.Battery_Enabled
|
|
&& config.PowerLimiter_BatterySocStartThreshold > 0.0
|
|
&& (millis() - Battery.stateOfChargeLastUpdate) < 60000
|
|
&& Battery.stateOfCharge >= config.PowerLimiter_BatterySocStartThreshold) {
|
|
return true;
|
|
}
|
|
|
|
// Otherwise we use the voltage threshold
|
|
if (config.PowerLimiter_VoltageStartThreshold <= 0.0) {
|
|
return false;
|
|
}
|
|
|
|
float correctedDcVoltage = getLoadCorrectedVoltage(inverter);
|
|
return correctedDcVoltage >= config.PowerLimiter_VoltageStartThreshold;
|
|
}
|
|
|
|
bool PowerLimiterClass::isStopThresholdReached(std::shared_ptr<InverterAbstract> inverter)
|
|
{
|
|
CONFIG_T& config = Configuration.get();
|
|
|
|
// Check if the Battery interface is enabled and the SOC stop threshold is reached
|
|
if (config.Battery_Enabled
|
|
&& config.PowerLimiter_BatterySocStopThreshold > 0.0
|
|
&& (millis() - Battery.stateOfChargeLastUpdate) < 60000
|
|
&& Battery.stateOfCharge <= config.PowerLimiter_BatterySocStopThreshold) {
|
|
return true;
|
|
}
|
|
|
|
// Otherwise we use the voltage threshold
|
|
if (config.PowerLimiter_VoltageStopThreshold <= 0.0) {
|
|
return false;
|
|
}
|
|
|
|
float correctedDcVoltage = getLoadCorrectedVoltage(inverter);
|
|
return correctedDcVoltage <= config.PowerLimiter_VoltageStopThreshold;
|
|
}
|
|
|
|
/// @brief calculate next inverter restart in millis
|
|
void PowerLimiterClass::calcNextInverterRestart()
|
|
{
|
|
CONFIG_T& config = Configuration.get();
|
|
|
|
// first check if restart is configured at all
|
|
if (config.PowerLimiter_RestartHour < 0) {
|
|
_nextInverterRestart = 1;
|
|
MessageOutput.println("[PowerLimiterClass::calcNextInverterRestart] _nextInverterRestart disabled");
|
|
return;
|
|
}
|
|
|
|
// read time from timeserver, if time is not synced then return
|
|
struct tm timeinfo;
|
|
if (getLocalTime(&timeinfo, 5)) {
|
|
// calculation first step is offset to next restart in minutes
|
|
uint16_t dayMinutes = timeinfo.tm_hour * 60 + timeinfo.tm_min;
|
|
uint16_t targetMinutes = config.PowerLimiter_RestartHour * 60;
|
|
if (config.PowerLimiter_RestartHour > timeinfo.tm_hour) {
|
|
// next restart is on the same day
|
|
_nextInverterRestart = targetMinutes - dayMinutes;
|
|
} else {
|
|
// next restart is on next day
|
|
_nextInverterRestart = 1440 - dayMinutes + targetMinutes;
|
|
}
|
|
#ifdef POWER_LIMITER_DEBUG
|
|
MessageOutput.printf("[PowerLimiterClass::calcNextInverterRestart] Localtime read %d %d / configured RestartHour %d\r\n", timeinfo.tm_hour, timeinfo.tm_min, config.PowerLimiter_RestartHour);
|
|
MessageOutput.printf("[PowerLimiterClass::calcNextInverterRestart] dayMinutes %d / targetMinutes %d\r\n", dayMinutes, targetMinutes);
|
|
MessageOutput.printf("[PowerLimiterClass::calcNextInverterRestart] next inverter restart in %d minutes\r\n", _nextInverterRestart);
|
|
#endif
|
|
// then convert unit for next restart to milliseconds and add current uptime millis()
|
|
_nextInverterRestart *= 60000;
|
|
_nextInverterRestart += millis();
|
|
} else {
|
|
MessageOutput.println("[PowerLimiterClass::calcNextInverterRestart] getLocalTime not successful, no calculation");
|
|
_nextInverterRestart = 0;
|
|
}
|
|
MessageOutput.printf("[PowerLimiterClass::calcNextInverterRestart] _nextInverterRestart @ %d millis\r\n", _nextInverterRestart);
|
|
}
|
|
|
|
bool PowerLimiterClass::useFullSolarPassthrough(std::shared_ptr<InverterAbstract> inverter)
|
|
{
|
|
CONFIG_T& config = Configuration.get();
|
|
|
|
// We only do full solar PT if general solar PT is enabled
|
|
if(!config.PowerLimiter_SolarPassThroughEnabled) {
|
|
return false;
|
|
}
|
|
|
|
// Check if the Battery interface is enabled and the SOC stop threshold is reached
|
|
if (config.Battery_Enabled
|
|
&& config.PowerLimiter_FullSolarPassThroughSoc > 0.0
|
|
&& (millis() - Battery.stateOfChargeLastUpdate) < 60000
|
|
&& Battery.stateOfCharge >= config.PowerLimiter_FullSolarPassThroughSoc) {
|
|
return true;
|
|
}
|
|
|
|
// Otherwise we use the voltage threshold
|
|
if (config.PowerLimiter_FullSolarPassThroughStartVoltage <= 0.0 || config.PowerLimiter_FullSolarPassThroughStopVoltage <= 0.0) {
|
|
return false;
|
|
}
|
|
|
|
float dcVoltage = inverter->Statistics()->getChannelFieldValue(TYPE_DC, (ChannelNum_t) config.PowerLimiter_InverterChannelId, FLD_UDC);
|
|
|
|
#ifdef POWER_LIMITER_DEBUG
|
|
MessageOutput.printf("[PowerLimiterClass::loop] useFullSolarPassthrough: FullSolarPT Start %f, FullSolarPT Stop: %f, dcVoltage: %f\r\n",
|
|
config.PowerLimiter_FullSolarPassThroughStartVoltage, config.PowerLimiter_FullSolarPassThroughStopVoltage, dcVoltage);
|
|
#endif
|
|
|
|
if (dcVoltage <= 0.0) {
|
|
return false;
|
|
}
|
|
|
|
if (dcVoltage >= config.PowerLimiter_FullSolarPassThroughStartVoltage) {
|
|
_fullSolarPassThroughEnabled = true;
|
|
}
|
|
|
|
if (dcVoltage <= config.PowerLimiter_FullSolarPassThroughStopVoltage) {
|
|
_fullSolarPassThroughEnabled = false;
|
|
}
|
|
|
|
return _fullSolarPassThroughEnabled;
|
|
}
|