OpenDTU-old/include/BatteryStats.h
MalteSchm 8abf614047 Feature: BMS initiated emergency charging
This change logically connects the AC-Charger with the BMS to add BMS
initiated emergency charging and respecting BMS current limits.
2024-04-02 21:05:00 +02:00

184 lines
6.0 KiB
C++

// SPDX-License-Identifier: GPL-2.0-or-later
#pragma once
#include <stdint.h>
#include "AsyncJson.h"
#include "Arduino.h"
#include "JkBmsDataPoints.h"
#include "VeDirectShuntController.h"
#include <cfloat>
// mandatory interface for all kinds of batteries
class BatteryStats {
public:
String const& getManufacturer() const { return _manufacturer; }
// the last time *any* datum was updated
uint32_t getAgeSeconds() const { return (millis() - _lastUpdate) / 1000; }
bool updateAvailable(uint32_t since) const;
uint8_t getSoC() const { return _soc; }
uint32_t getSoCAgeSeconds() const { return (millis() - _lastUpdateSoC) / 1000; }
float getVoltage() const { return _voltage; }
uint32_t getVoltageAgeSeconds() const { return (millis() - _lastUpdateVoltage) / 1000; }
// convert stats to JSON for web application live view
virtual void getLiveViewData(JsonVariant& root) const;
void mqttLoop();
// the interval at which all battery datums will be re-published, even
// if they did not change. used to calculate Home Assistent expiration.
virtual uint32_t getMqttFullPublishIntervalMs() const;
bool isSoCValid() const { return _lastUpdateSoC > 0; }
bool isVoltageValid() const { return _lastUpdateVoltage > 0; }
// returns true if the battery reached a critically low voltage/SoC,
// such that it is in need of charging to prevent degredation.
virtual bool getImmediateChargingRequest() const { return false; };
virtual float getChargeCurrent() const { return 0; };
virtual float getChargeCurrentLimitation() const { return FLT_MAX; };
protected:
virtual void mqttPublish() const;
void setSoC(float soc, uint8_t precision, uint32_t timestamp) {
_soc = soc;
_socPrecision = precision;
_lastUpdateSoC = _lastUpdate = timestamp;
}
void setVoltage(float voltage, uint32_t timestamp) {
_voltage = voltage;
_lastUpdateVoltage = _lastUpdate = timestamp;
}
String _manufacturer = "unknown";
uint32_t _lastUpdate = 0;
private:
uint32_t _lastMqttPublish = 0;
float _soc = 0;
uint8_t _socPrecision = 0; // decimal places
uint32_t _lastUpdateSoC = 0;
float _voltage = 0; // total battery pack voltage
uint32_t _lastUpdateVoltage = 0;
};
class PylontechBatteryStats : public BatteryStats {
friend class PylontechCanReceiver;
public:
void getLiveViewData(JsonVariant& root) const final;
void mqttPublish() const final;
bool getImmediateChargingRequest() const { return _chargeImmediately; } ;
float getChargeCurrent() const { return _current; } ;
float getChargeCurrentLimitation() const { return _chargeCurrentLimitation; } ;
private:
void setManufacturer(String&& m) { _manufacturer = std::move(m); }
void setLastUpdate(uint32_t ts) { _lastUpdate = ts; }
float _chargeVoltage;
float _chargeCurrentLimitation;
float _dischargeCurrentLimitation;
uint16_t _stateOfHealth;
// total current into (positive) or from (negative)
// the battery, i.e., the charging current
float _current;
float _temperature;
bool _alarmOverCurrentDischarge;
bool _alarmOverCurrentCharge;
bool _alarmUnderTemperature;
bool _alarmOverTemperature;
bool _alarmUnderVoltage;
bool _alarmOverVoltage;
bool _alarmBmsInternal;
bool _warningHighCurrentDischarge;
bool _warningHighCurrentCharge;
bool _warningLowTemperature;
bool _warningHighTemperature;
bool _warningLowVoltage;
bool _warningHighVoltage;
bool _warningBmsInternal;
bool _chargeEnabled;
bool _dischargeEnabled;
bool _chargeImmediately;
};
class JkBmsBatteryStats : public BatteryStats {
public:
void getLiveViewData(JsonVariant& root) const final {
getJsonData(root, false);
}
void getInfoViewData(JsonVariant& root) const {
getJsonData(root, true);
}
void mqttPublish() const final;
uint32_t getMqttFullPublishIntervalMs() const final { return 60 * 1000; }
void updateFrom(JkBms::DataPointContainer const& dp);
private:
void getJsonData(JsonVariant& root, bool verbose) const;
JkBms::DataPointContainer _dataPoints;
mutable uint32_t _lastMqttPublish = 0;
mutable uint32_t _lastFullMqttPublish = 0;
uint16_t _cellMinMilliVolt = 0;
uint16_t _cellAvgMilliVolt = 0;
uint16_t _cellMaxMilliVolt = 0;
uint32_t _cellVoltageTimestamp = 0;
};
class VictronSmartShuntStats : public BatteryStats {
public:
void getLiveViewData(JsonVariant& root) const final;
void mqttPublish() const final;
void updateFrom(VeDirectShuntController::veShuntStruct const& shuntData);
private:
float _current;
float _temperature;
bool _tempPresent;
uint8_t _chargeCycles;
uint32_t _timeToGo;
float _chargedEnergy;
float _dischargedEnergy;
String _modelName;
int32_t _instantaneousPower;
float _consumedAmpHours;
int32_t _lastFullCharge;
bool _alarmLowVoltage;
bool _alarmHighVoltage;
bool _alarmLowSOC;
bool _alarmLowTemperature;
bool _alarmHighTemperature;
};
class MqttBatteryStats : public BatteryStats {
friend class MqttBattery;
public:
// since the source of information was MQTT in the first place,
// we do NOT publish the same data under a different topic.
void mqttPublish() const final { }
// if the voltage is subscribed to at all, it alone does not warrant a
// card in the live view, since the SoC is already displayed at the top
void getLiveViewData(JsonVariant& root) const final { }
};