OpenDTU-old/lib/VeDirectFrameHandler/VeDirectMpptController.cpp
Bernhard Kirchen 3c8b8d4427
use frozen::string and frozen::map where reasonable (#593)
this change utilizes some of the features from library "frozen", which
was included upstream for the grid profile parser. to improve code
maintainability, a couple of std::maps mapping strings to values or the
other way around were introduced in OpenDTU-OnBattery-specific code at
the expense of some flash and computing overhead.

library "frozen" offers constexpr versions of map and string, which
saves initialization code and offers slightly faster lookups. this
brings the binary size down by ~25kB and should provide a small
performance improvement at runtime.
2024-01-04 23:28:34 +01:00

177 lines
4.8 KiB
C++

#include <Arduino.h>
#include "VeDirectMpptController.h"
void VeDirectMpptController::init(int8_t rx, int8_t tx, Print* msgOut, bool verboseLogging)
{
VeDirectFrameHandler::init(rx, tx, msgOut, verboseLogging, 1);
_spData = std::make_shared<veMpptStruct>();
if (_verboseLogging) { _msgOut->println("Finished init MPPTController"); }
}
bool VeDirectMpptController::isDataValid() const {
return VeDirectFrameHandler::isDataValid(*_spData);
}
void VeDirectMpptController::textRxEvent(char* name, char* value)
{
if (VeDirectFrameHandler::textRxEvent("MPPT", name, value, _tmpFrame)) {
return;
}
if (strcmp(name, "LOAD") == 0) {
if (strcmp(value, "ON") == 0)
_tmpFrame.LOAD = true;
else
_tmpFrame.LOAD = false;
}
else if (strcmp(name, "CS") == 0) {
_tmpFrame.CS = atoi(value);
}
else if (strcmp(name, "ERR") == 0) {
_tmpFrame.ERR = atoi(value);
}
else if (strcmp(name, "OR") == 0) {
_tmpFrame.OR = strtol(value, nullptr, 0);
}
else if (strcmp(name, "MPPT") == 0) {
_tmpFrame.MPPT = atoi(value);
}
else if (strcmp(name, "HSDS") == 0) {
_tmpFrame.HSDS = atoi(value);
}
else if (strcmp(name, "VPV") == 0) {
_tmpFrame.VPV = round(atof(value) / 10.0) / 100.0;
}
else if (strcmp(name, "PPV") == 0) {
_tmpFrame.PPV = atoi(value);
}
else if (strcmp(name, "H19") == 0) {
_tmpFrame.H19 = atof(value) / 100.0;
}
else if (strcmp(name, "H20") == 0) {
_tmpFrame.H20 = atof(value) / 100.0;
}
else if (strcmp(name, "H21") == 0) {
_tmpFrame.H21 = atoi(value);
}
else if (strcmp(name, "H22") == 0) {
_tmpFrame.H22 = atof(value) / 100.0;
}
else if (strcmp(name, "H23") == 0) {
_tmpFrame.H23 = atoi(value);
}
}
/*
* frameValidEvent
* This function is called at the end of the received frame.
*/
void VeDirectMpptController::frameValidEvent() {
_tmpFrame.P = _tmpFrame.V * _tmpFrame.I;
_tmpFrame.IPV = 0;
if (_tmpFrame.VPV > 0) {
_tmpFrame.IPV = _tmpFrame.PPV / _tmpFrame.VPV;
}
_tmpFrame.E = 0;
if ( _tmpFrame.PPV > 0) {
_efficiency.addNumber(static_cast<double>(_tmpFrame.P * 100) / _tmpFrame.PPV);
_tmpFrame.E = _efficiency.getAverage();
}
_spData = std::make_shared<veMpptStruct>(_tmpFrame);
_tmpFrame = {};
_lastUpdate = millis();
}
/*
* getCsAsString
* This function returns the state of operations (CS) as readable text.
*/
frozen::string const& VeDirectMpptController::veMpptStruct::getCsAsString() const
{
static constexpr frozen::map<uint8_t, frozen::string, 9> values = {
{ 0, "OFF" },
{ 2, "Fault" },
{ 3, "Bulk" },
{ 4, "Absorbtion" },
{ 5, "Float" },
{ 7, "Equalize (manual)" },
{ 245, "Starting-up" },
{ 247, "Auto equalize / Recondition" },
{ 252, "External Control" }
};
return getAsString(values, CS);
}
/*
* getMpptAsString
* This function returns the state of MPPT (MPPT) as readable text.
*/
frozen::string const& VeDirectMpptController::veMpptStruct::getMpptAsString() const
{
static constexpr frozen::map<uint8_t, frozen::string, 3> values = {
{ 0, "OFF" },
{ 1, "Voltage or current limited" },
{ 2, "MPP Tracker active" }
};
return getAsString(values, MPPT);
}
/*
* getErrAsString
* This function returns error state (ERR) as readable text.
*/
frozen::string const& VeDirectMpptController::veMpptStruct::getErrAsString() const
{
static constexpr frozen::map<uint8_t, frozen::string, 20> values = {
{ 0, "No error" },
{ 2, "Battery voltage too high" },
{ 17, "Charger temperature too high" },
{ 18, "Charger over current" },
{ 19, "Charger current reversed" },
{ 20, "Bulk time limit exceeded" },
{ 21, "Current sensor issue(sensor bias/sensor broken)" },
{ 26, "Terminals overheated" },
{ 28, "Converter issue (dual converter models only)" },
{ 33, "Input voltage too high (solar panel)" },
{ 34, "Input current too high (solar panel)" },
{ 38, "Input shutdown (due to excessive battery voltage)" },
{ 39, "Input shutdown (due to current flow during off mode)" },
{ 40, "Input" },
{ 65, "Lost communication with one of devices" },
{ 67, "Synchronisedcharging device configuration issue" },
{ 68, "BMS connection lost" },
{ 116, "Factory calibration data lost" },
{ 117, "Invalid/incompatible firmware" },
{ 118, "User settings invalid" }
};
return getAsString(values, ERR);
}
/*
* getOrAsString
* This function returns the off reason (OR) as readable text.
*/
frozen::string const& VeDirectMpptController::veMpptStruct::getOrAsString() const
{
static constexpr frozen::map<uint32_t, frozen::string, 10> values = {
{ 0x00000000, "Not off" },
{ 0x00000001, "No input power" },
{ 0x00000002, "Switched off (power switch)" },
{ 0x00000004, "Switched off (device moderegister)" },
{ 0x00000008, "Remote input" },
{ 0x00000010, "Protection active" },
{ 0x00000020, "Paygo" },
{ 0x00000040, "BMS" },
{ 0x00000080, "Engine shutdown detection" },
{ 0x00000100, "Analysing input voltage" }
};
return getAsString(values, OR);
}