OpenDTU-old/include/defaults.h
Bernhard Kirchen 13bc943dd5 Feature: Refactor/Simplify DPL settings
this changeset refactors the web application's DPL settings view. the
DPL settings can be complex, and they shall be presented in a way that
allows users to comprehend their meaning. irrelevant settings are now
hidden or displayed dynamically based on the influencing settings.

* group SoC thresholds into their own card

* hide battery SoC thresholds if battery disabled. if the user did not
  even enable the battery interface, battery SoC values will not be used
  for DPL decisions. in that case we completely hide the respective
  settings from the DPL admin view. this reduces the amount of settings
  for new users and especially users who don't even have a battery in
  their setup or have no BMS connected.

* group voltage thresholds and improve label texts

* fix load correction factor unit

* fix header (wording)

* group solar-passthrough settings in new card

* group inverter-related settings

* hide solar passthrough settings if VE.Direct is disabled. closes #662.

* completely disable form if any requirement is not met

* list available inverters by name and type. this makes it much more
  convenient to select the right inverter, especially since the order of
  the inverters in the web UI is decoupled from their position in the
  internal array, which was used to select them previously. care was
  taken that old configs select the same inverter after an update.
  when editing the DPL settings, the selects an inverter from the newly
  created drow-down list, and the respective old inverter is
  pre-selected.

* disable form if no inverter is configured (config alert)

* make inverter input selection dynamic. adjust selection to actual
  amount of channels for selected inverter. skip selection altogether if
  inverter has only one channel, or if it is solar powered.

* web app: wording adjustments

* group meta data into new property and exclude from submission. saves
  memory when evaluating the submitted settings.

* hide irrelevant settings if inverter is solar-powered

* move restart hour setting to inverter card. translate setting which
  disabled automatic restart.

* simplify "drain strategy" setting into an on/off toggle. care was
  taken that existing configs work the same after an upgrade. the
  respective drain strategy is translated into the new setting when
  reading the config. once the config is written, the new setting is
  persisted and the old is not part of the config any more.

* show more configuration hints, depending on actual configuration

* replace inputs by InputElement components where possible
2024-03-17 16:50:57 +01:00

159 lines
6.7 KiB
C

// SPDX-License-Identifier: GPL-2.0-or-later
#pragma once
#define SERIAL_BAUDRATE 115200
#define APP_HOSTNAME "OpenDTU-%06X"
#define HTTP_PORT 80
#define ACCESS_POINT_NAME "OpenDTU-"
#define ACCESS_POINT_PASSWORD "openDTU42"
#define ACCESS_POINT_TIMEOUT 3;
#define AUTH_USERNAME "admin"
#define SECURITY_ALLOW_READONLY true
#define WIFI_RECONNECT_TIMEOUT 30
#define WIFI_RECONNECT_REDO_TIMEOUT 600
#define WIFI_SSID ""
#define WIFI_PASSWORD ""
#define WIFI_DHCP true
#define MDNS_ENABLED false
#define NTP_SERVER "pool.ntp.org"
#define NTP_TIMEZONE "CET-1CEST,M3.5.0,M10.5.0/3"
#define NTP_TIMEZONEDESCR "Europe/Berlin"
#define NTP_LONGITUDE 10.4515f
#define NTP_LATITUDE 51.1657f
#define NTP_SUNSETTYPE 1U
#define MQTT_ENABLED false
#define MQTT_HOST ""
#define MQTT_PORT 1883U
#define MQTT_USER ""
#define MQTT_PASSWORD ""
#define MQTT_TOPIC "solar/"
#define MQTT_RETAIN true
#define MQTT_TLS false
// ISRG_Root_X1.crt -- Root CA for Letsencrypt
#define MQTT_ROOT_CA_CERT "-----BEGIN CERTIFICATE-----\n" \
"MIIFazCCA1OgAwIBAgIRAIIQz7DSQONZRGPgu2OCiwAwDQYJKoZIhvcNAQELBQAw\n" \
"TzELMAkGA1UEBhMCVVMxKTAnBgNVBAoTIEludGVybmV0IFNlY3VyaXR5IFJlc2Vh\n" \
"cmNoIEdyb3VwMRUwEwYDVQQDEwxJU1JHIFJvb3QgWDEwHhcNMTUwNjA0MTEwNDM4\n" \
"WhcNMzUwNjA0MTEwNDM4WjBPMQswCQYDVQQGEwJVUzEpMCcGA1UEChMgSW50ZXJu\n" \
"ZXQgU2VjdXJpdHkgUmVzZWFyY2ggR3JvdXAxFTATBgNVBAMTDElTUkcgUm9vdCBY\n" \
"MTCCAiIwDQYJKoZIhvcNAQEBBQADggIPADCCAgoCggIBAK3oJHP0FDfzm54rVygc\n" \
"h77ct984kIxuPOZXoHj3dcKi/vVqbvYATyjb3miGbESTtrFj/RQSa78f0uoxmyF+\n" \
"0TM8ukj13Xnfs7j/EvEhmkvBioZxaUpmZmyPfjxwv60pIgbz5MDmgK7iS4+3mX6U\n" \
"A5/TR5d8mUgjU+g4rk8Kb4Mu0UlXjIB0ttov0DiNewNwIRt18jA8+o+u3dpjq+sW\n" \
"T8KOEUt+zwvo/7V3LvSye0rgTBIlDHCNAymg4VMk7BPZ7hm/ELNKjD+Jo2FR3qyH\n" \
"B5T0Y3HsLuJvW5iB4YlcNHlsdu87kGJ55tukmi8mxdAQ4Q7e2RCOFvu396j3x+UC\n" \
"B5iPNgiV5+I3lg02dZ77DnKxHZu8A/lJBdiB3QW0KtZB6awBdpUKD9jf1b0SHzUv\n" \
"KBds0pjBqAlkd25HN7rOrFleaJ1/ctaJxQZBKT5ZPt0m9STJEadao0xAH0ahmbWn\n" \
"OlFuhjuefXKnEgV4We0+UXgVCwOPjdAvBbI+e0ocS3MFEvzG6uBQE3xDk3SzynTn\n" \
"jh8BCNAw1FtxNrQHusEwMFxIt4I7mKZ9YIqioymCzLq9gwQbooMDQaHWBfEbwrbw\n" \
"qHyGO0aoSCqI3Haadr8faqU9GY/rOPNk3sgrDQoo//fb4hVC1CLQJ13hef4Y53CI\n" \
"rU7m2Ys6xt0nUW7/vGT1M0NPAgMBAAGjQjBAMA4GA1UdDwEB/wQEAwIBBjAPBgNV\n" \
"HRMBAf8EBTADAQH/MB0GA1UdDgQWBBR5tFnme7bl5AFzgAiIyBpY9umbbjANBgkq\n" \
"hkiG9w0BAQsFAAOCAgEAVR9YqbyyqFDQDLHYGmkgJykIrGF1XIpu+ILlaS/V9lZL\n" \
"ubhzEFnTIZd+50xx+7LSYK05qAvqFyFWhfFQDlnrzuBZ6brJFe+GnY+EgPbk6ZGQ\n" \
"3BebYhtF8GaV0nxvwuo77x/Py9auJ/GpsMiu/X1+mvoiBOv/2X/qkSsisRcOj/KK\n" \
"NFtY2PwByVS5uCbMiogziUwthDyC3+6WVwW6LLv3xLfHTjuCvjHIInNzktHCgKQ5\n" \
"ORAzI4JMPJ+GslWYHb4phowim57iaztXOoJwTdwJx4nLCgdNbOhdjsnvzqvHu7Ur\n" \
"TkXWStAmzOVyyghqpZXjFaH3pO3JLF+l+/+sKAIuvtd7u+Nxe5AW0wdeRlN8NwdC\n" \
"jNPElpzVmbUq4JUagEiuTDkHzsxHpFKVK7q4+63SM1N95R1NbdWhscdCb+ZAJzVc\n" \
"oyi3B43njTOQ5yOf+1CceWxG1bQVs5ZufpsMljq4Ui0/1lvh+wjChP4kqKOJ2qxq\n" \
"4RgqsahDYVvTH9w7jXbyLeiNdd8XM2w9U/t7y0Ff/9yi0GE44Za4rF2LN9d11TPA\n" \
"mRGunUHBcnWEvgJBQl9nJEiU0Zsnvgc/ubhPgXRR4Xq37Z0j4r7g1SgEEzwxA57d\n" \
"emyPxgcYxn/eR44/KJ4EBs+lVDR3veyJm+kXQ99b21/+jh5Xos1AnX5iItreGCc=\n" \
"-----END CERTIFICATE-----\n"
#define MQTT_TLSCERTLOGIN false
#define MQTT_TLSCLIENTCERT ""
#define MQTT_TLSCLIENTKEY ""
#define MQTT_LWT_TOPIC "dtu/status"
#define MQTT_LWT_ONLINE "online"
#define MQTT_LWT_OFFLINE "offline"
#define MQTT_LWT_QOS 2U
#define MQTT_PUBLISH_INTERVAL 5U
#define MQTT_CLEAN_SESSION true
#define DTU_SERIAL 0x99978563412U
#define DTU_POLL_INTERVAL 5U
#define DTU_NRF_PA_LEVEL 0U
#define DTU_CMT_PA_LEVEL 0
#define DTU_CMT_FREQUENCY 865000000U
#define DTU_CMT_COUNTRY_MODE 0U
#define MQTT_HASS_ENABLED false
#define MQTT_HASS_EXPIRE true
#define MQTT_HASS_RETAIN true
#define MQTT_HASS_TOPIC "homeassistant/"
#define MQTT_HASS_INDIVIDUALPANELS false
#define DEV_PINMAPPING ""
#define DISPLAY_POWERSAFE true
#define DISPLAY_SCREENSAVER true
#define DISPLAY_ROTATION 2U
#define DISPLAY_CONTRAST 60U
#define DISPLAY_LANGUAGE 0U
#define DISPLAY_DIAGRAM_DURATION (10UL * 60UL * 60UL)
#define DISPLAY_DIAGRAM_MODE 1U
#define REACHABLE_THRESHOLD 2U
#define LED_BRIGHTNESS 100U
#define MAX_INVERTER_LIMIT 2250
// values specific to downstream project OpenDTU-OnBattery start here:
#define VEDIRECT_ENABLED false
#define VEDIRECT_VERBOSE_LOGGING false
#define VEDIRECT_UPDATESONLY true
#define POWERMETER_ENABLED false
#define POWERMETER_INTERVAL 10
#define POWERMETER_SOURCE 2
#define POWERMETER_SDMBAUDRATE 9600
#define POWERMETER_SDMADDRESS 1
#define POWERLIMITER_ENABLED false
#define POWERLIMITER_SOLAR_PASSTHROUGH_ENABLED true
#define POWERLIMITER_SOLAR_PASSTHROUGH_LOSSES 3
#define POWERLIMITER_BATTERY_ALWAYS_USE_AT_NIGHT false
#define POWERLIMITER_INTERVAL 10
#define POWERLIMITER_IS_INVERTER_BEHIND_POWER_METER true
#define POWERLIMITER_IS_INVERTER_SOLAR_POWERED false
#define POWERLIMITER_INVERTER_ID 0ULL
#define POWERLIMITER_INVERTER_CHANNEL_ID 0
#define POWERLIMITER_TARGET_POWER_CONSUMPTION 0
#define POWERLIMITER_TARGET_POWER_CONSUMPTION_HYSTERESIS 0
#define POWERLIMITER_LOWER_POWER_LIMIT 10
#define POWERLIMITER_UPPER_POWER_LIMIT 800
#define POWERLIMITER_IGNORE_SOC false
#define POWERLIMITER_BATTERY_SOC_START_THRESHOLD 80
#define POWERLIMITER_BATTERY_SOC_STOP_THRESHOLD 20
#define POWERLIMITER_VOLTAGE_START_THRESHOLD 50.0
#define POWERLIMITER_VOLTAGE_STOP_THRESHOLD 49.0
#define POWERLIMITER_VOLTAGE_LOAD_CORRECTION_FACTOR 0.001
#define POWERLIMITER_RESTART_HOUR -1
#define POWERLIMITER_FULL_SOLAR_PASSTHROUGH_SOC 100
#define POWERLIMITER_FULL_SOLAR_PASSTHROUGH_START_VOLTAGE 100.0
#define POWERLIMITER_FULL_SOLAR_PASSTHROUGH_STOP_VOLTAGE 100.0
#define BATTERY_ENABLED false
#define BATTERY_PROVIDER 0 // Pylontech CAN receiver
#define BATTERY_JKBMS_INTERFACE 0
#define BATTERY_JKBMS_POLLING_INTERVAL 5
#define HUAWEI_ENABLED false
#define HUAWEI_CAN_CONTROLLER_FREQUENCY 8000000UL
#define HUAWEI_AUTO_POWER_VOLTAGE_LIMIT 42.0
#define HUAWEI_AUTO_POWER_ENABLE_VOLTAGE_LIMIT 42.0
#define HUAWEI_AUTO_POWER_LOWER_POWER_LIMIT 150
#define HUAWEI_AUTO_POWER_UPPER_POWER_LIMIT 2000
#define VERBOSE_LOGGING true