/* VeDirectMpptController.cpp * * * 2020.08.20 - 0.0 - ??? * 2024.03.18 - 0.1 - add of: - temperature from "Smart Battery Sense" connected over VE.Smart network * - temperature from internal MPPT sensor * - "total DC input power" from MPPT's connected over VE.Smart network */ #include #include "VeDirectMpptController.h" //#define PROCESS_NETWORK_STATE void VeDirectMpptController::init(int8_t rx, int8_t tx, Print* msgOut, bool verboseLogging, uint16_t hwSerialPort) { VeDirectFrameHandler::init("MPPT", rx, tx, msgOut, verboseLogging, hwSerialPort); } bool VeDirectMpptController::processTextDataDerived(std::string const& name, std::string const& value) { if (name == "LOAD") { _tmpFrame.LOAD = (value == "ON"); return true; } if (name == "CS") { _tmpFrame.CS = atoi(value.c_str()); return true; } if (name == "ERR") { _tmpFrame.ERR = atoi(value.c_str()); return true; } if (name == "OR") { _tmpFrame.OR = strtol(value.c_str(), nullptr, 0); return true; } if (name == "MPPT") { _tmpFrame.MPPT = atoi(value.c_str()); return true; } if (name == "HSDS") { _tmpFrame.HSDS = atoi(value.c_str()); return true; } if (name == "VPV") { _tmpFrame.VPV = round(atof(value.c_str()) / 10.0) / 100.0; return true; } if (name == "PPV") { _tmpFrame.PPV = atoi(value.c_str()); return true; } if (name == "H19") { _tmpFrame.H19 = atof(value.c_str()) / 100.0; return true; } if (name == "H20") { _tmpFrame.H20 = atof(value.c_str()) / 100.0; return true; } if (name == "H21") { _tmpFrame.H21 = atoi(value.c_str()); return true; } if (name == "H22") { _tmpFrame.H22 = atof(value.c_str()) / 100.0; return true; } if (name == "H23") { _tmpFrame.H23 = atoi(value.c_str()); return true; } return false; } /* * frameValidEvent * This function is called at the end of the received frame. */ void VeDirectMpptController::frameValidEvent() { _tmpFrame.P = _tmpFrame.V * _tmpFrame.I; if (_tmpFrame.VPV > 0) { _tmpFrame.IPV = _tmpFrame.PPV / _tmpFrame.VPV; } if (_tmpFrame.PPV > 0) { _efficiency.addNumber(static_cast(_tmpFrame.P * 100) / _tmpFrame.PPV); _tmpFrame.E = _efficiency.getAverage(); } if (!_canSend) { return; } // Copy from the "VE.Direct Protocol" documentation // For firmware version v1.52 and below, when no VE.Direct queries are sent to the device, the // charger periodically sends human readable (TEXT) data to the serial port. For firmware // versions v1.53 and above, the charger always periodically sends TEXT data to the serial port. // --> We just use hex commandes for firmware >= 1.53 to keep text messages alive if (atoi(_tmpFrame.FW) < 153) { return; } using Command = VeDirectHexCommand; using Register = VeDirectHexRegister; sendHexCommand(Command::GET, Register::ChargeControllerTemperature); sendHexCommand(Command::GET, Register::SmartBatterySenseTemperature); sendHexCommand(Command::GET, Register::NetworkTotalDcInputPower); #ifdef PROCESS_NETWORK_STATE sendHexCommand(Command::GET, Register::NetworkInfo); sendHexCommand(Command::GET, Register::NetworkMode); sendHexCommand(Command::GET, Register::NetworkStatus); #endif // PROCESS_NETWORK_STATE } void VeDirectMpptController::loop() { VeDirectFrameHandler::loop(); auto resetTimestamp = [this](auto& pair) { if (pair.first > 0 && (millis() - pair.first) > (10 * 1000)) { pair.first = 0; } }; resetTimestamp(_tmpFrame.MpptTemperatureMilliCelsius); resetTimestamp(_tmpFrame.SmartBatterySenseTemperatureMilliCelsius); resetTimestamp(_tmpFrame.NetworkTotalDcInputPowerMilliWatts); #ifdef PROCESS_NETWORK_STATE resetTimestamp(_tmpFrame.NetworkInfo); resetTimestamp(_tmpFrame.NetworkMode); resetTimestamp(_tmpFrame.NetworkStatus); #endif // PROCESS_NETWORK_STATE } /* * hexDataHandler() * analyse the content of VE.Direct hex messages * Handels the received hex data from the MPPT */ bool VeDirectMpptController::hexDataHandler(VeDirectHexData const &data) { if (data.rsp != VeDirectHexResponse::GET && data.rsp != VeDirectHexResponse::ASYNC) { return false; } auto regLog = static_cast(data.addr); switch (data.addr) { case VeDirectHexRegister::ChargeControllerTemperature: _tmpFrame.MpptTemperatureMilliCelsius = { millis(), static_cast(data.value) * 10 }; if (_verboseLogging) { _msgOut->printf("%s Hex Data: MPPT Temperature (0x%04X): %.2f°C\r\n", _logId, regLog, _tmpFrame.MpptTemperatureMilliCelsius.second / 1000.0); } return true; break; case VeDirectHexRegister::SmartBatterySenseTemperature: if (data.value == 0xFFFF) { if (_verboseLogging) { _msgOut->printf("%s Hex Data: Smart Battery Sense Temperature is not available\r\n", _logId); } return true; // we know what to do with it, and we decided to ignore the value } _tmpFrame.SmartBatterySenseTemperatureMilliCelsius = { millis(), static_cast(data.value) * 10 - 272150 }; if (_verboseLogging) { _msgOut->printf("%s Hex Data: Smart Battery Sense Temperature (0x%04X): %.2f°C\r\n", _logId, regLog, _tmpFrame.SmartBatterySenseTemperatureMilliCelsius.second / 1000.0); } return true; break; case VeDirectHexRegister::NetworkTotalDcInputPower: if (data.value == 0xFFFFFFFF) { if (_verboseLogging) { _msgOut->printf("%s Hex Data: Network total DC power value " "indicates non-networked controller\r\n", _logId); } _tmpFrame.NetworkTotalDcInputPowerMilliWatts = { 0, 0 }; return true; // we know what to do with it, and we decided to ignore the value } _tmpFrame.NetworkTotalDcInputPowerMilliWatts = { millis(), data.value * 10 }; if (_verboseLogging) { _msgOut->printf("%s Hex Data: Network Total DC Power (0x%04X): %.2fW\r\n", _logId, regLog, _tmpFrame.NetworkTotalDcInputPowerMilliWatts.second / 1000.0); } return true; break; #ifdef PROCESS_NETWORK_STATE case VeDirectHexRegister::NetworkInfo: _tmpFrame.NetworkInfo = { millis(), static_cast(data.value) }; if (_verboseLogging) { _msgOut->printf("%s Hex Data: Network Info (0x%04X): 0x%X\r\n", _logId, regLog, data.value); } return true; break; case VeDirectHexRegister::NetworkMode: _tmpFrame.NetworkMode = { millis(), static_cast(data.value) }; if (_verboseLogging) { _msgOut->printf("%s Hex Data: Network Mode (0x%04X): 0x%X\r\n", _logId, regLog, data.value); } return true; break; case VeDirectHexRegister::NetworkStatus: _tmpFrame.NetworkStatus = { millis(), static_cast(data.value) }; if (_verboseLogging) { _msgOut->printf("%s Hex Data: Network Status (0x%04X): 0x%X\r\n", _logId, regLog, data.value); } return true; break; #endif // PROCESS_NETWORK_STATE default: return false; break; } return false; }