Commit Graph

700 Commits

Author SHA1 Message Date
helgeerbe
ff44267e73 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into merge-v24.3.31 2024-04-03 11:53:03 +02:00
MalteSchm
8abf614047 Feature: BMS initiated emergency charging
This change logically connects the AC-Charger with the BMS to add BMS
initiated emergency charging and respecting BMS current limits.
2024-04-02 21:05:00 +02:00
PhilJaro
da96273085
Fix typo in German locale (#831) 2024-04-02 12:05:45 +02:00
Rene
eff8d52014 better alignment inverter, issue 360 2024-03-25 22:42:22 +01:00
Bernhard Kirchen
054a677575 DPL settings in web app: split metadata from config
users are manipulating the DPL using HTTP POST requests. often they are
requesting the current settings using HTTP GET on the respective route,
then change a particular settings, and send all the data back using HTTP
POST. if they failed to remove the metadata node from the JSON,
OpenDTU-OnBattery would not be able to process the JSON due to its size.
the web app does not submit the metadata.

to avoid problems, the metadata is now split from the configuration
data.
2024-03-23 22:13:50 +01:00
helgeerbe
5259fc172a Merge remote-tracking branch 'tbnobody/OpenDTU/master' into v24.3.15 2024-03-20 09:42:35 +01:00
PhilJaro
4f0385285c add new Victron SmartShunt values to liveView and MQTT (HASS) 2024-03-17 21:00:32 +01:00
Snoopy-HSS
f6680bd664 Feature: Support SMA HomeManager 2.0 as PowerMeter 2024-03-17 20:20:29 +01:00
Bernhard Kirchen
13bc943dd5 Feature: Refactor/Simplify DPL settings
this changeset refactors the web application's DPL settings view. the
DPL settings can be complex, and they shall be presented in a way that
allows users to comprehend their meaning. irrelevant settings are now
hidden or displayed dynamically based on the influencing settings.

* group SoC thresholds into their own card

* hide battery SoC thresholds if battery disabled. if the user did not
  even enable the battery interface, battery SoC values will not be used
  for DPL decisions. in that case we completely hide the respective
  settings from the DPL admin view. this reduces the amount of settings
  for new users and especially users who don't even have a battery in
  their setup or have no BMS connected.

* group voltage thresholds and improve label texts

* fix load correction factor unit

* fix header (wording)

* group solar-passthrough settings in new card

* group inverter-related settings

* hide solar passthrough settings if VE.Direct is disabled. closes #662.

* completely disable form if any requirement is not met

* list available inverters by name and type. this makes it much more
  convenient to select the right inverter, especially since the order of
  the inverters in the web UI is decoupled from their position in the
  internal array, which was used to select them previously. care was
  taken that old configs select the same inverter after an update.
  when editing the DPL settings, the selects an inverter from the newly
  created drow-down list, and the respective old inverter is
  pre-selected.

* disable form if no inverter is configured (config alert)

* make inverter input selection dynamic. adjust selection to actual
  amount of channels for selected inverter. skip selection altogether if
  inverter has only one channel, or if it is solar powered.

* web app: wording adjustments

* group meta data into new property and exclude from submission. saves
  memory when evaluating the submitted settings.

* hide irrelevant settings if inverter is solar-powered

* move restart hour setting to inverter card. translate setting which
  disabled automatic restart.

* simplify "drain strategy" setting into an on/off toggle. care was
  taken that existing configs work the same after an upgrade. the
  respective drain strategy is translated into the new setting when
  reading the config. once the config is written, the new setting is
  persisted and the old is not part of the config any more.

* show more configuration hints, depending on actual configuration

* replace inputs by InputElement components where possible
2024-03-17 16:50:57 +01:00
Bernhard Kirchen
7d6b7252bf polish support for second VE.Direct MPPT charge controller
* fix compiler warning in SerialPortManager.cpp: function must not
  return void

* clean up and simplify implementation of usesHwPort2()
  * make const
  * overrides are final
  * default implementation returns false
  * implement in header, as the implementation is very simple

* rename PortManager to SerialPortManager. as "PortManager" is too
  generic, the static instance of the serial port manager is renamed to
  "SerialPortManager". the class is therefore renamed to
  SerialPortManagerClass, which is in line with other (static) classes
  withing OpenDTU(-OnBattery).

* implement separate data ages for MPPT charge controllers

* make sure MPPT data and live data time out

* do not use invalid data of MPPT controlers for calculations

* add :key binding to v-for iterating over MPPT instances
2024-03-17 16:50:15 +01:00
Arman Vartan
75541be248 Feature: Support for second Victron MPPT charge controller
this change adds support for a second Victron MPPT charge controller
using a second serial connection.

* Add device configuration for a second victron mppt
* Update VedirectView for second victron mppt
* Update MqttHandleVedirect for second victron mppt
* Update MqttHandleVedirectHass for second victron mppt
* Handle nonexisting victron controllers with optionals
* Add bool-function to Battery and inherited classes, if uart port 2 is
  being used
* Introduced a serial port manager. In order to prevent the battery and
  the Victron MPPT to use the same hw serial ports, this class keeps
  track of the used ports and their owners.
2024-03-17 16:50:15 +01:00
Thomas Basler
3138e28cdf webapp: Remove not required cast to string 2024-03-15 19:54:29 +01:00
Thomas Basler
a0d0aec677 Fix: Correct detection of Hoymiles serial if it contains hex characters 2024-03-15 19:46:24 +01:00
Bernhard Kirchen
2efa1b35b0 live view: do not access undefined data
if the respective feature is disabled, there is no data. do not try to
access it.
2024-03-15 08:55:21 +01:00
Bernhard Kirchen
cf27bd29d7 adjust (new) about texts to OpenDTU-OnBattery 2024-03-14 16:27:32 +01:00
Thomas Basler
437f572c39 Fix: Don't throw exception if git_hash is not set 2024-03-12 22:11:19 +01:00
Thomas Basler
bd8d93bf92 Feature: Allow enabling and disabling of the version check
Fix #1787
2024-03-12 18:35:19 +01:00
Thomas Basler
9634c93a3c Fix: Show firmware update tooltip only if newer version available
Closes #1796
2024-03-12 17:27:43 +01:00
Bernhard Kirchen
c6f81806d6 DPL: make "IsInverterSolarPowered" configurable through web app 2024-03-09 15:40:13 +01:00
Thomas Basler
f995287a6e Feature: Add support for HERF inverters 2024-03-06 21:57:18 +01:00
Bernhard Kirchen
50635ee2ce Feature: live view: update with respective frequency
the update frequency of Victron MPPT charger data, the battery Soc, the
huawei charger power, and the power meter differ from one another, and
differ in particular from the inverter update frequency.

the OnBattery-specific data is now handled in a new method, outside the
upstream code, which merely call the new function(s). the new function
will update the websocket independently from inverter updates. also, it
adds the respective data if it actually changed since it was last
updated through the websocket.

for the webapp to be able to recover in case of errors, all values are
also written to the websocket with a fixed interval of 10 seconds.
2024-03-05 11:31:44 +01:00
Bernhard Kirchen
c560d1d90e
fix: copy OnBattery-specific data from live view websocket (#696)
closes #685.
closes #682.
2024-02-29 17:09:18 +01:00
helgeerbe
c72ae561c7 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2024-02-19 16:03:56 +01:00
Bernhard Kirchen
3595725f8a Feature: implement subscription to battery voltage MQTT topic
this extends the MqttBattery implementation by an additional topic which
allows to subscribe to receive battery voltage readings through the MQTT
broker. similar to the battery SoC topic, this allows to import a
critical battery data point for the DPL, in case the user chooses to use
voltage thresholds rather than SoC thresholds to control the DPL. if an
otherwise incompatible BMS is available which publishes the battery pack
voltage through MQTT, this can now be used to feed accurate voltage
readings to the DPL.
2024-02-18 22:17:15 +01:00
Bernhard Kirchen
921302bf73 Feature: DPL: add switch allowing to ignore SoC
unfortunately, the battery SoC values reported by battery BMSs are
unreliable, at least for some users, or at least without regular
(manual) full charge cycles to calibrate the BMS. it offers great
advantages to connect OpenDTU-OnBattery to a BMS (MQTT publishing of
values, Home Assistent integration, etc.), but previously the users
were then forced to configure the DPL by SoC values.

this change allows to configure the DPL such that SoC values are
ignored. instead, the voltage limits are used to make DPL decisions, as
if no SoC was available in the first place.

the SoC related setting are hidden from the DPL settings view if SoC
values are configured to be ignored.

closes #654.
2024-02-18 21:46:42 +01:00
Hannes0009
a1cd1617e4
Update de.json
improved german orthography
2024-02-14 11:06:07 +01:00
Thomas Basler
b9bf454237 webapp: Add link to documentation in about view 2024-02-10 02:10:06 +01:00
Thomas Basler
8e01a275af Merge branch 'pr1693' into dev 2024-02-02 22:36:18 +01:00
Nikolaj Kappler
86b9625254 fix #1668
use builtin bootstrap css for scrolling
2024-02-02 22:34:58 +01:00
Thomas Basler
7e2064e264 Feature: Added support for boards with 16MB flash and PSRAM 2024-02-02 20:33:42 +01:00
Thomas Basler
c27ecc3620 BREAKING CHANGE: Web API Endpoint /api/livedata/status
To reduce the heap usage it is necessary to send the inverters one by one instead of a huge response. A simple call to `/api/livedata/status` returns just some very general information. If detailed inverter information are required the inverter serial number has to appended `?inv=<serial number>`.
The websocket also returns only one inverter at a time. It as to be assembled at client side.
2024-01-30 22:29:25 +01:00
vaterlangen
97f006d867 fixed typo in OTA text 2024-01-27 15:18:25 +01:00
helgeerbe
7094bca7db fix: Inverter Labels in InverterTotalInfo 2024-01-26 13:34:03 +01:00
helgeerbe
ebacc2f25f Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2024-01-25 23:36:32 +01:00
Thomas Basler
d99de94c00 webapp: Fix lint errors 2024-01-21 16:48:47 +01:00
Thomas Basler
4cfb1b1c26 Fix: PullToRefresh does not work anymore
It was using the wrong mainElement
2024-01-21 00:55:05 +01:00
Thomas Basler
8a80289474 Feature: Implement firmware update check is a opt-in to protect your privacy 2024-01-20 22:43:40 +01:00
Thomas Basler
9428eecce4 webapp: Use CardElement in InverterTotalInfo 2024-01-19 22:03:26 +01:00
Thomas Basler
a06d21024c webapp: Move interfaces to seperate file 2024-01-19 21:48:39 +01:00
Thomas Basler
6b31a4d470 webapp: Introduce Modal component
Less duplicated code
2024-01-19 21:36:18 +01:00
Thomas Basler
5d63f64411 webapp: Fix typo 2024-01-19 20:02:03 +01:00
Thomas Basler
0584eadcf2 Feature: Automatic page reload after firmware upgrade
This will work after the current upgrade if this code was loaded.
2024-01-19 19:10:49 +01:00
Thomas Basler
f7119bc3c7 webapp: Fix font-feature class 2024-01-19 17:20:57 +01:00
Nikolaj Kappler
199351c703 webapp: Correctly center header text 2024-01-18 20:39:43 +01:00
Nikolaj Kappler
a7479d33e3 webapp: Reduce wasted horizontal space for better mobile UX 2024-01-18 20:39:43 +01:00
Nikolaj Kappler
41f3955429 webapp: Vertically center Header/Logo Text 2024-01-18 20:39:43 +01:00
Nikolaj Kappler
bfeb852e23 webapp: Remove redundant main container 2024-01-18 20:39:43 +01:00
Nikolaj Kappler
caaa7b6347 fix count being a string 2024-01-18 20:39:43 +01:00
Nikolaj Kappler
f26e824247 fix #1649
one of the goals of my pull request, besides simplifying the code was to have localization.

It's nice that the browser can handle this, but for consistency, we'll go with vue-i18n since it is already available
2024-01-18 20:39:42 +01:00
Thomas Basler
6233ad12ae webapp: Prefix Country with CMT2300A 2024-01-18 20:39:28 +01:00
helgeerbe
63205f88be Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2024-01-16 17:39:45 +01:00
Thomas Basler
c20caf8097 Feature: Support HMS/HMT inverters in different countries with different frequency bands
Thanks to @Fribur, @homeautomation2022 and @stefan123t
2024-01-14 16:37:34 +01:00
Thomas Basler
abc53f4257 Merge branch 'pr1639' into dev 2024-01-13 13:01:21 +01:00
Thomas Basler
2c92750100 webapp: Remove hard coded min/max frequencies for CMT module 2024-01-13 12:51:20 +01:00
Thomas Basler
ee78698e37 Migrate all frequency calculations to Hz
Previously the code contains calculations  using a mixture  of kHz and Hz.

Thanks to @Fribur
2024-01-13 12:51:20 +01:00
Thomas Basler
f013698471 Feature: Added fullscreen diagram to display 2024-01-13 11:31:12 +01:00
Nikolaj Kappler
6166ecdb7d refactor webapp/utils/time 2024-01-13 11:14:20 +01:00
Thomas Basler
637d4f06a3 Feature: Added option to disable the diagram at the display 2024-01-08 14:19:26 +01:00
Thomas Basler
9d8e195ce1 Merge branch 'pr1611' into dev 2024-01-07 01:53:43 +01:00
Bernhard Kirchen
2608080708 Feature: add heap details to system info and prometheus (#595)
this change adds the values of ESP.gteMaxAllocHeap() and
ESP.getMinFreeHead() to the prometheus metrics and the system
information object. the web UI uses these values to diplay the size of
the largest free contiguous block, calculate a rough estimate for the
level of fragmentation, and the maximum usage of heap memory since boot
in absolute and relative amounts.
2024-01-06 20:12:35 +01:00
Thomas Basler
024ee26705 Feature: Added pull to refresh and websocket indicator 2024-01-06 20:03:52 +01:00
Thomas Basler
88d75673fc Prevent config corruption by checking whether memory allocation was successfull. 2024-01-05 21:55:15 +01:00
Bernhard Kirchen
377406f10c
Feature: add heap details to system info and prometheus (#595)
this change adds the values of ESP.gteMaxAllocHeap() and
ESP.getMinFreeHead() to the prometheus metrics and the system
information object. the web UI uses these values to diplay the size of
the largest free contiguous block, calculate a rough estimate for the
level of fragmentation, and the maximum usage of heap memory since boot
in absolute and relative amounts.
2024-01-05 21:46:31 +01:00
Bernhard Kirchen
e7a005839b
Feature: implement MQTT-driven battery provider (#589)
this battery provider implementation subscribes to a user-configurable
MQTT topic to retrieve the battery SoC value. the value is not
re-published under a different topic. there is no card created in the
web app's live view, since the SoC is already part of the totals at the
top of the live view. that is the only info this battery provider
implements.

closes #293.
relates to #581.
2024-01-04 15:42:10 +01:00
Thomas Basler
4053e31a5e Prevent config corruption by checking whether memory allocation was successfull. 2024-01-04 13:42:39 +01:00
Moritz Lerch
d62234ac65
webapp: add missing button spacing 2024-01-02 23:40:21 +01:00
MalteSchm
5bd3ce5a8f
Reducing lower limit for AC-charger (#574) 2024-01-01 17:06:58 +01:00
helgeerbe
cbf7680836 merge v23.12.31 2024-01-01 14:50:51 +01:00
Bernhard Kirchen
7928f2f8cf
Feature: JK BMS: add more values to live view (#552)
there are more interesting values available to display in the live view.
however, adding them made the list of values very long. this can be
mitigated by using a new column/card, which uses the available screen
space nicely on bigger screens.
2023-12-30 16:46:44 +01:00
Bernhard Kirchen
bb34fa74fd
Fix: use FormFooter in OnBattery-specific forms (#569)
the upstream project introduced a new Vue component "FormFooter", which
is used to end an input form, namely all settings forms. we should not
only use this component as well, but the save button on our forms
actually broke since the text dtuadmin.Save is replaced by base.Save.

also replace the use of dtuadmin.Seconds with base.Seconds, such that an
upstream change to dtuadmin.Seconds will not break the battery admin an
AC charger views.
2023-12-30 16:46:16 +01:00
Bernhard Kirchen
03060e453c remove obsolete save button texts in french locale 2023-12-30 10:27:46 +01:00
helgeerbe
d494810975
merge V23.12.16 (#556)
* Optimize Sun data calculation

* Remove not required enum

* Split config struct into different sub structs

* Feature: Allow configuration of LWT QoS

* Made resetreason methods static

* Feature: Implement offset cache for "YieldDay"

Thanks to @broth-itk for the idea!
Fix: #1258 #1397

* Add Esp32-Stick-PoE-A

* remove broken LilyGO_T_ETH_POE config, use device profile instead

* Feature: High resolution Icon and PWA (Progressive Web App) functionality

Fix: #1289

* webapp: Update dependencies

* Initialize TaskScheduler

* Migrate SunPosition to TaskScheduler

* Migrate Datastore to TaskScheduler

* Migrate MqttHandleInverterTotal to TaskSchedule

* Migrate MqttHandleHass to TaskScheduler

* Migrate MqttHandleDtu to TaskScheduler

* Migrate MqttHandleInverter to TaskScheduler

* Migrate LedSingle to TaskScheduler

* Migrate NetworkSettings to TaskScheduler

* Migrate InverterSettings to TaskScheduler

* Migrate MessageOutput to TaskScheduler

* Migrate Display_Graphic to TaskScheduler

* Migrate WebApi to TaskScheduler

* Split InverterSettings into multiple tasks

* Calculate SunPosition only every 5 seconds

* Split LedSingle into multiple tasks

* Upgrade espMqttClient from 1.4.5 to 1.5.0

* Doc: Correct amount of MPP-Tracker

* Added HMT-1600-4T and HMT-1800-4T to DevInfoParser

Fix #1524

* Adjusted inverter names for HMS-1600/1800/2000-4T

* Add channel count to description of detected inverter type (DevInfoParser)

* Adjust device web api endpoint for dynamic led count

* Feature: Added ability to change the brightness of the LEDs

Based on the idea of @moritzlerch with several modifications like pwmTable and structure

* webapp: Update dependencies

* Update olikraus/U8g2 from 2.35.7 to 2.35.8

* Remove not required onWebsocketEvent

* Remove code nesting

* Introduce several const statements

* Remove not required AsyncEventSource

* Doc: Added byte specification to each command

* Feature: Added basic Grid Profile parser which shows the used profile and version

Other values are still outstanding.

* Optimize AlarmLogParser to save memory

* Add libfrozen to project to create constexpr maps

* Feature: First version of GridProfile Parser which shows all values contained in the profile.

* webapp: Update dependencies

* Apply better variable names

* Remove not required casts

* Add additional compiler flags to prevent errors

* Add const statement to several variables

* Replace NULL by nullptr

* Update bblanchon/ArduinoJson from 6.21.3 to 6.21.4

* Add const keyword to method parameters

* Add const keyword to methods

* Use references instead of pointers whenver possible

* Adjust member variable names in MqttSettings

* Adjust member variable names in NetworkSettings

* webapp: Update timezone database to latest version

* webapp: Beautify and unify form footers

* Feature: Allow setting of an inverter limit of 0% and 0W

Thanks to @madmartin in #1270

* Feature: Allow links in device profiles

These links will be shown on the hardware settings page.

* Doc: Added hint regarding HMS-xxxx-xT-NA inverters

* Feature: Added DeviceProfile for CASmo-DTU

Based on #1565

* Upgrade actions/upload-artifact from v3 to v4

* Upgrade actions/download-artifact from v3 to v4

* webapp: add app.js.gz

* Gridprofileparser: Added latest known values

Thanks to @stefan123t and @noone2k

* webapp: Fix lint errors

* Feature: Add DTU to Home Assistant Auto Discovery

This is based on PR 1365 from @CFenner with several fixes and optimizations

* Fix: Remove debug output as it floods the console

* Fix: Gridprofileparser: Add additional error handling if profile is unknown

* webapp: add app.js.gz

* Fix: Offset cache for "YieldDay" did not work correctly

* webapp: update dependencies

* webapp: add app.js.gz

* Fix: yarn.lock was outdated

* Fix: yarn build error

* Fix: Reset Yield day correction in combination with Zero Yield Day on Midnight lead to wrong values.

* Fix: Allow negative values in GridProfileParser

* Correct variable name

* Fix #1579: Static IP in Ethernet mode did not work correctly

* Feature: Added diagram to display

This is based on the idea of @Henrik-Ingenieur and was discussed in #1504

* webapp: update dependencies

* webapp: add app.js.gz

---------

Co-authored-by: Thomas Basler <thomas@familie-basler.net>
Co-authored-by: Pierre Kancir <pierre.kancir.emn@gmail.com>
2023-12-27 11:49:57 +01:00
Thomas Basler
0ddc7fd28d Feature: Added diagram to display
This is based on the idea of @Henrik-Ingenieur and was discussed in #1504
2023-12-19 17:26:24 +01:00
Thomas Basler
e0cc1559d0 webapp: Fix lint errors 2023-12-17 14:40:04 +01:00
Bernhard Kirchen
6e78c5bd1c
Feature: JK BMS: export (more) data to live view and MQTT (#549)
* add more values to web app live view. this should add all interesting
  values for the web app live view. those include important values and
  values that change frequently.

* add more interesting JK BMS dummy messages: one has 0% SoC and an
  alarm (discharge undervoltage) set. the other has the undertemperature
  alarm set.

* add alarms and warnings to live view

* publish alarm and status bits through MQTT individually

* publish cell voltages to MQTT broker

* remove trailing spaces in BatteryStats class
2023-12-15 10:59:07 +01:00
Thomas Basler
7950f92d8b Feature: Allow links in device profiles
These links will be shown on the hardware settings page.
2023-12-14 13:53:45 +01:00
Thomas Basler
b4ead9d6ec Feature: Allow setting of an inverter limit of 0% and 0W
Thanks to @madmartin in #1270
2023-12-13 22:15:49 +01:00
Thomas Basler
14f6669314 webapp: Beautify and unify form footers 2023-12-13 19:40:07 +01:00
Thomas Basler
06651f365a Feature: First version of GridProfile Parser which shows all values contained in the profile. 2023-12-11 14:58:17 +01:00
Thomas Basler
00bc631e87 Feature: Added basic Grid Profile parser which shows the used profile and version
Other values are still outstanding.
2023-12-09 11:12:37 +01:00
Thomas Basler
9ae791edd4 Feature: Added ability to change the brightness of the LEDs
Based on the idea of @moritzlerch with several modifications like pwmTable and structure
2023-12-07 12:46:38 +01:00
Thomas Basler
1de3b48166 Feature: Implement offset cache for "YieldDay"
Thanks to @broth-itk for the idea!
Fix: #1258 #1397
2023-11-22 20:21:25 +01:00
Thomas Basler
ee4811bbe7 Feature: Allow configuration of LWT QoS 2023-11-19 16:17:10 +01:00
helgeerbe
0085970567 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-11-16 09:20:08 +01:00
helgeerbe
d4d42167ec Merge branch 'pr/philippsandhaus/510' into development 2023-11-15 12:33:50 +01:00
Thomas Basler
89b4b8ea85 Merge branch 'pr1441' into dev 2023-10-31 19:30:56 +01:00
CommanderRedYT
7c875187a8
Implemented mDNS 2023-10-30 20:53:45 +01:00
Thomas Basler
6a64fe6e1a Fix #1456: Prevent white spaces in username field 2023-10-30 16:45:34 +01:00
Bernhard Kirchen
254b95cb0f
Fix: replace links to upstream project where applicable (#514) 2023-10-23 13:24:05 +02:00
Thomas Basler
b477db7045 Fix #1440: Add CSS code to stop numbers changing the size of their container 2023-10-21 12:54:51 +02:00
Philipp Sandhaus
b159c31258 Display efficiency measuremnt for Huawei AC charger in % in web interface 2023-10-20 22:14:45 +02:00
Bernhard Kirchen
4d4aadf8de
Feature: AC charger: configurable CAN controller frequency (#500) 2023-10-19 16:16:01 +02:00
Thomas Basler
f1a8c2ea82 Feature: Added additional event log descriptions and implemented i18n 2023-10-11 13:22:42 +02:00
helgeerbe
b461aff622 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-10-10 09:26:43 +02:00
Thomas Basler
76dfaa7d3b Fix #1405: Add some border around icons when in multi line mode 2023-10-09 17:06:47 +02:00
Philipp Sandhaus
7142921021
Integration of Victron SmartShunt via VE.Direct (#452)
* Move Mppt logic to subclass

* Added Definitions for Shunts and restructering

* First integration of SmartShunt data into Web Interface

* Code cleanup

* VE.Direct: whitespace cleanup

* VE.Direct: manage HardwareSerial in unique_ptr

* VE.Direct: _efficiency is only needed by MPPT

* VE.Direct: keep as many members private as possible

* VE.Direct: use int8_t for pins (as before)

* VictronSmartShunt: _verboseLogging is not used

* VE.Direct: OR (off reason) is MPPT specific

it also applies to Phoenix inverters and Smart BuckBoost, but since
there is no support for those, the code is moved to the MPPT controller.

* Added Shunt alarms to liveview
Changed from double to int for several readings

* Update build.yml to allow manual builds

---------

Co-authored-by: Philipp Sandhaus <philipp.sandhaus@cewe.de>
Co-authored-by: Bernhard Kirchen <schlimmchen@posteo.net>
2023-09-22 17:24:57 +02:00
helgeerbe
b081845b95 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-09-19 12:28:00 +02:00
helgeerbe
f7bd4a40d8 revert Revert "Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development"
merge of v23.9.11 broke the system. As a workaround upgrade espressif32 from 6.3.2 to 6.4.0 is skipped. See #440
2023-09-14 13:45:23 +02:00
Thomas Basler
0533c0bcc8 webapp: Rename Fehlernummer to ID
It's not just errors, its also regular messges
2023-09-13 23:19:43 +02:00
helgeerbe
2eeb5f1d19 Revert "Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development"
This reverts commit eb1c2dbd8c, reversing
changes made to 0cb42a6424.

merge of v23.9.11 broke the system
2023-09-12 20:18:10 +02:00
helgeerbe
eb1c2dbd8c Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-09-12 19:27:32 +02:00
Thomas Basler
9ac6dd6e8d Feature: First very basic support to read the grid profile
The parser is still missing and requires community support to collect data.
2023-09-07 22:08:07 +02:00
Thomas Basler
ec9af886d5 Feature: Added option to set daily yield to zero at midnight 2023-09-05 20:27:52 +02:00
Thomas Basler
c46f85db9c webapp: Use max field to determine whether to show a string or not 2023-09-04 19:54:07 +02:00
Bernhard Kirchen
ba303da742
VE.Direct: Reset state machine on timeout, fix and extend logging (#416)
* VE.Direct: reset state machine on timeout

there will never be a large gap between two bytes of the same frame.
if such a large gap is observed, reset the state machine so it tries
to decode a new frame once more data arrives.

this is helpful in case of corrupted data that prevents the state
machine of transitioning to the final state even though the VE.Direct
data producer is done sending bytes that belong to the same frame.

* VE.Direct: print problems to MessageOutput

this includes the web console in particular, where many users have
access to while the serial console is not attached or monitored.

* VE.Direct: collect serial input into buffer and print

should help debug issues for users.

* VE.Direct: implement and use verbose logging switch
2023-09-04 14:07:48 +02:00
Thomas Basler
986d67a3d0 Fix: Better reconnect handling in Live View if invalid data where received 2023-09-02 12:22:55 +02:00
Thomas Basler
6127fbe940 Feature: Added option to set runtime values to zero when inverter becames unreachable 2023-09-02 12:22:22 +02:00
Thomas Basler
9dec05def8 Fix: Check if valid data was received from websocket before assigning it
Otherwise it can lead to exceptions in inverterData method
2023-09-02 01:43:20 +02:00
Thomas Basler
2c41be106e Feature: Allow setting of the Reachable Threshold per inverter 2023-09-01 19:17:12 +02:00
Thomas Basler
c5f9f460cd Feature: Added config option to change MQTT CleanSession Flag 2023-09-01 18:03:30 +02:00
Thomas Basler
b95236c170 Feature: webapp: Move inverter settings into different tabs 2023-09-01 00:20:56 +02:00
Bernhard Kirchen
f744629b0b
Support for Jikong JK BMS using serial connection (#319) 2023-08-31 16:21:32 +02:00
helgeerbe
ca308d0895 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-08-28 13:12:07 +02:00
Bernhard Kirchen
b7214161b8
live view: remove disabled -OnBattery-specifc views from DOM (#372)
instead of hiding views, we can also avoid adding them to the DOM. this
has a couple of advantages:

* no HTTP request for data is sent and no websocket connection is
  established for disabled features.
* JavaScript that causes errors due to incomplete or incompatible data
  of features that are disabled anyways do not trigger the browser
  debugger.
2023-08-10 13:39:21 +02:00
Stefan Schultheis, OE1SCS
629ede3cbd Update en.json
typo. power safe != power save
2023-08-09 18:21:36 +02:00
Stefan Schultheis, OE1SCS
94f6078c9e Update de.json
bessere Übersetzung
2023-08-09 18:20:36 +02:00
helgeerbe
5a72d74982
fix #362 system Info checks git head, instead of build branch (#374) 2023-08-09 17:45:54 +02:00
helgeerbe
21bbed9b8e Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-08-09 12:37:33 +02:00
Thomas Basler
ac4ddbe23d webapp: Fix lint error 2023-08-08 22:50:30 +02:00
Bernhard Kirchen
2bce8311a7
MQTT verbose logging fixes (#341)
* MQTT verbose logging: fix typo

this typo caused that verbose logging was always disabled for MQTT and
could not be enabled.

* webapp status: show MQTT verbose logging setting
2023-07-31 14:16:35 +02:00
helgeerbe
2440028d38 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-07-24 13:16:15 +02:00
Thomas Basler
1146e15ea6 Move units from description to postfix for AP timeout 2023-07-22 18:30:18 +02:00
Martin Dummer
8bfa7e530c Feature: Admin AccessPoint Timeout now configurable
Make the administrative accesspoint timeout configurable. The default
value is 3 minutes, values from 0-99999 are possible, where 0 means
infinite (no timeout).

Signed-off-by: Martin Dummer <martin.dummer@gmx.net>
2023-07-22 18:14:07 +02:00
Thomas Basler
eaacce7483 Feature: Show error in webapp if pin_mapping.json contains syntax errors 2023-07-22 15:51:16 +02:00
Thomas Basler
972dea297b Fix: Prevent runtime errors in webapp when invalid pin_mapping.json is provided 2023-07-22 15:30:40 +02:00
Bernhard Kirchen
f0def2ae89
Selective verbosity (#318)
* DPL: implement verbose logging switch

* MQTT: implement verbose logging switch

* power meter: implement verbose logging switch

* Hoymiles lib: implement verbose logging switch

* cpp linting: "final" makes "virtual" and "override" redundant

... however, using only "final" is not as verbose.
2023-07-18 09:57:03 +02:00
Martin
0dd1566dc6
Fix: WebApp Live-View: adjust window-title and header (#317)
adjust window-title and header from OpenDTU to OpenDTU-onBattery
Additionally change orientation of battery symbol to vertically centered
(looks nicer)

Signed-off-by: Martin Dummer <martin.dummer@gmx.net>
2023-07-18 09:51:59 +02:00
Bernhard Kirchen
f3297930b5
DPL: account for solar passthrough losses (#307)
* fix another fixable "passtrough" typo

the typo in the config's identifier is not changed to preserve
compatibility while not spending the effort to migrate the setting.

* webapp language: prefer SoC over SOC

* DPL: implement solar passthrough loss factor

in (full) solar passthrough mode, the inverter output power is coupled
to the charge controler output power. the inverter efficiency is already
accounted for. however, the battery might still be slowly discharged for
two reasons: (1) line losses are not accounted for and (2) the inverter
outputs a little bit more than permitted by the power limit.

this is undesirable since the battery is significantly drained if solar
passthrough is active for a longer period of time. also, when using full
solar passthrough and a battery communication interface, the SoC will
slowly degrade to a value below the threshold value for full solar
passthrough. this makes the system switch from charging the battery
(potentially rapidly) to discharging the battery slowly. this switch
might happen in rather fast succession. that's effectively
trickle-charging the battery.

instead, this new factor helps to account for line losses between the
solar charge controller and the inverter, such that the battery is
actually not involved in solar passthrough. the value can be increased
until it is observed that the battery is not discharging when solar
passthrough is active.
2023-07-12 13:20:37 +02:00
MalteSchm
475aab1e9a
floating point input (#302) 2023-07-09 17:09:33 +02:00
helgeerbe
3fb062b5cc fix: typo 2023-07-07 17:08:51 +02:00
helgeerbe
ffa9be0835 fix: #294 Passthrough Spelling 2023-07-07 17:05:44 +02:00
Bernhard Kirchen
e457ab73f9
Fix vedirect polling (#291)
* VE.Direct: remove polling interval

the polling interval was meant to limit the amount of MQTT updates.
however, that is already controlled by the global MQTT publish interval.
the removed interval was instead used to limit polling of the VE.Direct
UART for incoming data.

the Victron device sends data unsolicited. the VeDirectFrameHandler does
not implement any polling mechanism. no data is ever sent to the Victron
device.

what the removed polling interval did was cause a buffer overrun of the
HardwareSerial class, since the incoming data was not processed in time.
so every five seconds, we read a whole valid VE.Direct frame, plus some
old data, which was not a whole frame, leading to VE.Direct error
messages to pop up.

with the polling interval removed, no framing errors are reported, and
instead we gain new data from the charge controller approximately ever
two seconds -- for free.

* VE.Direct: change texts to correct VE.Direct capital letters

* VE.Direct: improve "UpdatesOnly" switch labels

especially since the publish interval setting is gone, the label makes
it hard to comprehend what the switch does. update the texts to better
explain what the switch is used for.

use the same text on the VE.Direct info view.

* VE.Direct: use StatusBadge on info view

there were custom badges to indicate the VE.Direct settings. replace
those by the common StatusBadge to make then look the same as the other
badged on the info views.
2023-07-04 12:04:38 +02:00
helgeerbe
006f63ed02 feature: add digest auth on power meter
Power Meter -> HTTP(S) + Jason configuration allows now basic and digest authentication (all Shelly Gen2 devices)
2023-07-04 11:54:46 +02:00
helgeerbe
9a4eb75160 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-07-02 14:32:12 +02:00
MalteSchm
e279ce08c4 Dynamic power control and more power control modes on the Huawei PSU 2023-07-01 12:37:55 +02:00
jdloic
3df65b3d37 Ajout de traductions en Français 2023-06-26 18:31:54 +02:00
helgeerbe
6ed3ce7417 Fix: #274
Iverter is behind power meter - switch does not work
2023-06-26 12:27:26 +02:00
Bernhard Kirchen
07bb0b03f7
DPL hysteresis fix and refactor of setNewPowerLimit() (#264) 2023-06-26 11:52:33 +02:00
helgeerbe
7d73ae3c20 Fix: linting error 2023-06-22 21:55:58 +02:00
Bernhard Kirchen
9995c1172e
VE.Direct live view enhancements (#269)
* add calculated values to VE.Direct data

solar current, battery output power, and the charger's efficiency can be
calculated from the values reported by the charger. the efficiency must
be taken with a grain of salt. it seems that the solar power value and
the battery output voltage/current are not always in sync. for that
reason a moving average is used to smooth out the calculated efficiency
value.

* show calculated VE.Direct values in web live view

order the values and translations similarly for the input and output,
starting with power at the top, then voltage, then current as the last
of these three.

* VE.Direct live view: use 'd' as unit for days

'd' is the SI unit symbol for days and does not need translation, which
is desirable as units are not translated throughout the project.

* refactor VE.Direct live view

* move Dynamic Power Limiter data into its own type.
* split VE.Direct data into three types: "device", "input", and
  "output". hence all input and output values are now ValueObject, which
  allows to iterate over them using a loop without typing issues.
* generate the tables with input and output values using a loop, rather
  than defining each row individually.
* localize numbers using $n (vue method), which fixes switching the
  number format (dot vs. comma) when switching the language.
* use no decimal point for power values (they are integers), three
  decimal points for kWh values (charger only reports two decimal
  places, but three are easier to read since the unit is *kilo* Wh), one
  decimal point for the efficiency, and two for voltage and current.
* update language tokens to avoid mapping JSON keys to language keys
  (use the JSON keys to access the language tokens).
* re-structure language tokes so the brief keys took over from
  VeDirectFrameHandler always make sense (nest into "input" and
  "output").
* order values similarly from top to bottom: power, then voltage, then
  current. this is following the order of the inverters' details.
* group values by type/unit (yield and max. power) and order them
  "newest" to "oldest" from top to bottom.
* increase the DynamicJsonDocument as it was too small to hold the newly
  added data.

* update webapp_dist to include VE.Direct live view refactoring
2023-06-22 21:32:20 +02:00
helgeerbe
e68baa3086 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-06-09 13:16:56 +02:00
MalteSchm
e0a8da84d7 full solar passthrough 2023-06-09 13:09:58 +02:00
Thomas Basler
91d3cd1da2 Feature: Show BSSID in the web interface 2023-06-08 19:56:22 +02:00
helgeerbe
8298a0c36f
Merge pull request #255 from madmartin:inverter_restart
Feature: add daily restart for the inverter
2023-06-05 10:10:14 +02:00
Martin Dummer
c727e21a49
Feature: add daily restart for the inverter
Add a configurable restart option for the inverter to set the "YieldDay"
values to zero.

Signed-off-by: Martin Dummer <martin.dummer@gmx.net>
2023-06-04 09:14:42 +02:00
MalteSchm
e7c8a89bd3 inital version of full solar passthrough
Webinterface change to set full solar passthrough values

Adding webapi and config changes to enable full solar passthrough over certain battery Soc

inital version of full solar passthrough in power limiter

Passthrough mode can be enabled via MQTT

translations

re-enable comment

remove unused variable
2023-06-02 12:49:24 +02:00
Thomas Basler
5a37948ca9 Fix: If no sunset/sunrise calculation is possible a wrong value is shown
This is catched now and a proper message is shown in the web UI. Also the mode is set to day.
2023-06-01 18:39:50 +02:00
Thomas Basler
1c8bd8091b Feature: Allow reordering of the inverters in the live view
Reordering can be done in the inverter settings via drag&drop.
2023-05-29 20:17:07 +02:00
Thomas Basler
e7198073af Feature: Allow configuration of sunset type 2023-05-24 19:21:44 +02:00
helgeerbe
a3e7439181 fix(action): sort tags in chronological order 2023-05-24 09:13:04 +02:00
Thomas Basler
752362d2df Feature: Added localization setting to display
Its possible to change the language of the display
2023-05-23 18:25:12 +02:00
helgeerbe
1c7b7d3cdf Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-05-10 18:16:25 +02:00
Thomas Basler
efcbd81927 Feature: Add used PIO environment to the system info page 2023-05-08 21:43:50 +02:00
helgeerbe
dae4c6fbf5 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-04-28 22:38:39 +02:00
Thomas Basler
58214ccbea Fix: webapp console: Only add the date at the beginning if the last character was a newline 2023-04-28 21:03:45 +02:00
helgeerbe
2d14d9f69e Merge branch '198-enhancement-simplifying-the-settings-menu' into development 2023-04-28 20:11:07 +02:00
helgeerbe
3f0291dce0 : Enhancement - Simplifying the settings menu #198 2023-04-28 20:08:36 +02:00
helgeerbe
80f1af32f8 Fix: Link to git hash references onBattery repo now 2023-04-27 21:55:07 +02:00
helgeerbe
46c733ca31 Revert "Fix: Link to git hash references onBattery repo"
This reverts commit 23b35d9b00.
2023-04-27 21:45:50 +02:00
helgeerbe
32913c2b2e Revert "fix: change url for firmware info to"
This reverts commit dfa0a1c98b.
2023-04-27 21:45:50 +02:00
helgeerbe
dfa0a1c98b fix: change url for firmware info to
openDTU-onbattery
2023-04-27 21:31:38 +02:00
helgeerbe
23b35d9b00 Fix: Link to git hash references onBattery repo
now
2023-04-27 20:15:57 +02:00
helgeerbe
d4a5570806 Feature: Add battery Icon on Navbar, to
indicate openDTU-onBattery is running
2023-04-26 12:52:28 +02:00
helgeerbe
37b5edb010 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-04-25 18:51:18 +02:00
Thomas Basler
b2c249a711 webapp: Enable stricter error reporting 2023-04-24 20:31:24 +02:00
MalteSchm
8764809259 Webapp update do display power values 2023-04-23 18:49:32 +02:00
Thomas Basler
04f62e03b8 BREAKING CHANGE: Web API Endpoint /api/eventlog/status no nested serial object
It's not required as the  eventlog just contains events from requested inverter
2023-04-20 22:41:55 +02:00
helgeerbe
84a6ed540d Merge branch 've.direct-hex' into development 2023-04-19 14:33:00 +02:00
helgeerbe
943a0eb58e Fix: [Request] rename "Erlaubter Stromverbrauch" to "Angestrebter Netzbezug" helgeerbe/OpenDTU-OnBattery#178 2023-04-19 14:25:24 +02:00
helgeerbe
6a9585cd1e Fix: Power Limiter Settings / cannot set permitted current below zero helgeerbe/OpenDTU-OnBattery#171 2023-04-19 14:19:26 +02:00
helgeerbe
a1b3bdfee8 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-04-18 12:09:22 +02:00
Thomas Basler
59f43a82a8 BREAKING CHANGE: Web API Endpoint /api/devinfo/status requires GET parameter inv=
Only the requested inverter is sent to the client. This reduces the size of the json response --> Less memory.

It should also fix #814.
2023-04-17 21:48:16 +02:00
helgeerbe
40cee1f9ca Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-04-17 11:08:55 +02:00
Thomas Basler
85070ffda0 webapp: Add hint to cmt frequency that it can take up to 15min until a connection is established 2023-04-15 10:55:48 +02:00
Thomas Basler
d6c2a4ba1c webapp: Remove hard coded texts in dtuadmin view 2023-04-15 10:55:48 +02:00
Thomas Basler
ac5df9a91d webapp: Implement CMT pa level as range control 2023-04-15 10:55:48 +02:00
Thomas Basler
1e7b16adb9 webapp: Nicer cmt frequency input 2023-04-15 10:55:48 +02:00
Thomas Basler
371e405eed Added configuration of CMT modules frequency to webapp 2023-04-15 10:55:48 +02:00
Thomas Basler
996404ceed Introduce gpio2 for the CMT2300A module
This implements the sending interrupt instead of polling. On the other hand, gpio3 is made optional.
2023-04-15 10:55:48 +02:00
Thomas Basler
854fcdaeae Allow configuration of the TX PA Level of the CMT2300A module 2023-04-15 10:55:48 +02:00
Thomas Basler
fc5f6887cb Adjust name from CMT2300a to CMT2300A 2023-04-15 10:55:47 +02:00
Thomas Basler
3e1b778565 Change max power limit from 1500W to 2250W to support HMS/HMT inverters 2023-04-15 10:55:47 +02:00
Thomas Basler
0ec90e0000 webapp: Adjusted radio problem hint in home view to detect problems of nrf and cmt radios 2023-04-15 10:55:47 +02:00
Thomas Basler
c19d2007bd webapp: Added cmt radio status to system overview 2023-04-15 10:55:47 +02:00
Thomas Basler
ef614751b1 webapp: Show CMT pins in device manager 2023-04-15 10:55:47 +02:00
Marc-Philip
a554423d39
one more typo 2023-04-14 08:14:23 +02:00
helgeerbe
b00ca02aac fix layout for vedirect live data on small devices 2023-04-13 11:38:20 +02:00
helgeerbe
1dc73f91ee Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-04-13 10:18:49 +02:00
Marc-Philip
16877a8ea3
fix typo 2023-04-13 09:18:07 +02:00
Thomas Basler
0f1b3f1560 webapp: Implement combo boxes again as objects
1. Key  is a magic number which is used in the c++ backend
2. Based on the object model some further extension will be done soon
2023-04-12 19:58:34 +02:00
Thomas Basler
ebaccc9b3f Merge branch 'pr801' into dev 2023-04-12 19:35:58 +02:00
Thomas Basler
9d45c5d68a Merge branch 'pr799' into dev 2023-04-12 19:32:07 +02:00
MalteSchm
43f7553cdd removing commented lines 2023-04-12 15:56:33 +02:00
MalteSchm
72289cda1a fixed linting issues, pushing to github for test run 2023-04-12 13:21:32 +02:00
Martin Dummer
971ae6d1be
Feature: MQTT add TLS authentication
User asked for TLS client certificate based login from DTU to MQTT
server. This PR implements storage and use of x509 client certificate
and private key.

Signed-off-by: Martin Dummer <martin.dummer@gmx.net>
2023-04-12 08:33:10 +02:00
fischaxe
d2d0790d90 fix: broken hardware profile handling on lang switch 2023-04-11 10:44:25 +02:00
fischaxe
9e2d7b479b fix: display rotation didn't adapt language changes 2023-04-11 09:47:27 +02:00
fischaxe
a01b9fc141 fix: pa level didn't listen to language switching 2023-04-11 09:47:24 +02:00
helgeerbe
71128e5a55 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-04-11 09:37:56 +02:00
fischaxe
994a543b87 webapp: added css table-responsive for lower resolutions 2023-04-10 10:45:24 +02:00