Commit Graph

59 Commits

Author SHA1 Message Date
Thomas Basler
f995287a6e Feature: Add support for HERF inverters 2024-03-06 21:57:18 +01:00
Thomas Basler
c27ecc3620 BREAKING CHANGE: Web API Endpoint /api/livedata/status
To reduce the heap usage it is necessary to send the inverters one by one instead of a huge response. A simple call to `/api/livedata/status` returns just some very general information. If detailed inverter information are required the inverter serial number has to appended `?inv=<serial number>`.
The websocket also returns only one inverter at a time. It as to be assembled at client side.
2024-01-30 22:29:25 +01:00
Thomas Basler
d99de94c00 webapp: Fix lint errors 2024-01-21 16:48:47 +01:00
Thomas Basler
6b31a4d470 webapp: Introduce Modal component
Less duplicated code
2024-01-19 21:36:18 +01:00
Thomas Basler
024ee26705 Feature: Added pull to refresh and websocket indicator 2024-01-06 20:03:52 +01:00
Thomas Basler
b4ead9d6ec Feature: Allow setting of an inverter limit of 0% and 0W
Thanks to @madmartin in #1270
2023-12-13 22:15:49 +01:00
Thomas Basler
06651f365a Feature: First version of GridProfile Parser which shows all values contained in the profile. 2023-12-11 14:58:17 +01:00
Thomas Basler
f1a8c2ea82 Feature: Added additional event log descriptions and implemented i18n 2023-10-11 13:22:42 +02:00
Thomas Basler
76dfaa7d3b Fix #1405: Add some border around icons when in multi line mode 2023-10-09 17:06:47 +02:00
Thomas Basler
9ac6dd6e8d Feature: First very basic support to read the grid profile
The parser is still missing and requires community support to collect data.
2023-09-07 22:08:07 +02:00
Thomas Basler
c46f85db9c webapp: Use max field to determine whether to show a string or not 2023-09-04 19:54:07 +02:00
Thomas Basler
986d67a3d0 Fix: Better reconnect handling in Live View if invalid data where received 2023-09-02 12:22:55 +02:00
Thomas Basler
9dec05def8 Fix: Check if valid data was received from websocket before assigning it
Otherwise it can lead to exceptions in inverterData method
2023-09-02 01:43:20 +02:00
Thomas Basler
1c8bd8091b Feature: Allow reordering of the inverters in the live view
Reordering can be done in the inverter settings via drag&drop.
2023-05-29 20:17:07 +02:00
Thomas Basler
04f62e03b8 BREAKING CHANGE: Web API Endpoint /api/eventlog/status no nested serial object
It's not required as the  eventlog just contains events from requested inverter
2023-04-20 22:41:55 +02:00
Thomas Basler
59f43a82a8 BREAKING CHANGE: Web API Endpoint /api/devinfo/status requires GET parameter inv=
Only the requested inverter is sent to the client. This reduces the size of the json response --> Less memory.

It should also fix #814.
2023-04-17 21:48:16 +02:00
Thomas Basler
3e1b778565 Change max power limit from 1500W to 2250W to support HMS/HMT inverters 2023-04-15 10:55:47 +02:00
Thomas Basler
acf413b616 webapp: Show inverter status in grey if polling is disabled (e.g. at night) 2023-04-03 22:25:32 +02:00
Thomas Basler
8959795304 webapp: Fix typos 2023-03-27 19:03:18 +02:00
Thomas Basler
8d8c7f8a71 Fixed typo: Successfull --> Successful 2023-03-23 23:30:55 +01:00
Thomas Basler
61795172ff Fix #670: Incorrect hiding of unused strings in Live View 2023-03-08 12:55:44 +01:00
Thomas Basler
220884f72e Implement #633: Show only strings with irridiation > 0
If no irridiation is entered for all strings, all strings are shown.
2023-02-28 19:41:07 +01:00
Thomas Basler
3c9639bb53 WebApp: Show additional inverter info in DevInfo dialog
* Production Year
* Production Week
2023-02-23 23:08:16 +01:00
Thomas Basler
3b7aef63f8 BREAKING CHANGE: Web API!
In order to support multiple AC channels in future the WebAPI had to be changed. AC and DC channels are now grouped in a sub object containing the channels beginning with 0.
2023-02-13 18:37:55 +01:00
Thomas Basler
9f86698dfc webapp: format seconds correctly 2023-01-17 23:24:46 +01:00
Thomas Basler
a88687eae6 webapp: replace own formatNumber by vue-i18n $n 2023-01-02 15:50:22 +01:00
Thomas Basler
ef8c3a3d42 webapp: Apply correct datetime format based on current locale in HomeView 2022-12-31 15:29:05 +01:00
Thomas Basler
77268d7be2 webapp: Some better german translations
(thanks to @homeautomation22)
2022-12-26 12:37:00 +01:00
Thomas Basler
6eee2ce5f6 webapp: Organize components 2022-12-25 12:02:10 +01:00
Thomas Basler
c6ebea3e9e webapp: Organize imports 2022-12-25 12:02:10 +01:00
Thomas Basler
c59e3b686b webapp: Translate set status 2022-12-24 00:01:55 +01:00
Thomas Basler
793f0c5d99 webapi: Power: Show language independent webapi messages 2022-12-24 00:01:55 +01:00
Thomas Basler
fb35e95f3c webapi: Limit: Show language independent webapi messages 2022-12-24 00:01:54 +01:00
Thomas Basler
ab25914c48 Added i18n support for the web interface 2022-12-24 00:01:54 +01:00
Thomas Basler
de61ab3694 webapp: Added helpfull tooltips to the web interface 2022-12-20 20:39:59 +01:00
Thomas Basler
0a349b75a4 webapp: ESLint fixes 2022-12-08 22:20:40 +01:00
Thomas Basler
2a19b46d52 Add authentication to websocket 2022-11-23 21:00:54 +01:00
Thomas Basler
e4ba104fd9 webapp. Fix error in Live View when no inverter is loaded 2022-11-22 23:41:49 +01:00
Thomas Basler
a06a8fec3d webapp: Removed hardcoded info about views which require authentication
If the return value of a API request equals 401 then the user will be redirected to the login page.
Using this method it's possible to decided within the API if a authentication is needed or not.
2022-11-22 20:37:01 +01:00
Thomas Basler
f8b601f871 Show several hints and tips at Live View
This contains the following information:
* No connection to the NRF module possible
* No time set
* Default password used
2022-11-20 15:08:36 +01:00
Thomas Basler
fe22c95221 webapp: Show Data Age also as timestamp if age > 300 sec 2022-11-18 23:16:52 +01:00
Thomas Basler
e0b069ff3d Password protection for limit/power settings API 2022-11-08 18:34:00 +01:00
Thomas Basler
ed6e9dd9cd webapp: Use correct Complimentary colours 2022-11-01 16:54:13 +01:00
Thomas Basler
438ce36bab Added sum values of all inverters to web UI 2022-11-01 16:33:20 +01:00
Thomas Basler
69b675bc64 BREAKING CHANGE: Structure WebAPI /api/livedata/status changed
The different inverter data are now in a subobject called "inverters".
This is required to extend the API by other data then the inverter values
2022-11-01 15:04:05 +01:00
Thomas Basler
860710c47a Changed minimal limit from 10% to 2% 2022-10-31 15:23:09 +01:00
Thomas Basler
3612dd3d52 Apply correct unit of measure format
See https://en.wikipedia.org/wiki/Space_(punctuation)#Unit_symbols_and_numbers
2022-10-31 15:12:32 +01:00
Thomas Basler
20e856ecfc Use correct locale for number formatting
Also moved numberFormat method so separate file
2022-10-31 15:08:56 +01:00
Thomas Basler
c2c57e33c3 webapp: Only allow max_power in input field if available 2022-10-19 22:16:35 +02:00
Thomas Basler
f9221606c6 webapp: create interface for LimitConfig 2022-10-19 22:16:33 +02:00