Commit Graph

672 Commits

Author SHA1 Message Date
Bernhard Kirchen
e6eaa001e7
DPL: use testThreshold() in useFullSolarPassthrough() (#357) 2023-08-06 17:00:27 +02:00
Thomas Basler
9179b672f5 Use lock_guard to simplify code 2023-08-05 01:25:53 +02:00
Bernhard Kirchen
aff7924411
Inhibit solar passthrough while battery below stop threshold (#354)
* DPL: improve verbose logging

* shorten DPL log prefix
* canUseDirectSolarPower() was printed two times
* _batteryDischargeEnabled was printed two times
* convert boolean values to human-readable strings
* add units where possible
* split messages into block "before calculating new limit" and "after
  calculating new limit", as the latter cannot rely on _inverter being
  available.
* order messages such that variables whose value is derived from other
  variables are printed later than their dependencies.
* merge output into blocks (one instance near "Printout some stats")
* remove more redundant info (produced in functions outside loop())
* print target grid consumption

* DPL: inhibit solar passthrough while stop threshold reached

* DPL: implement and use isBelowStopThreshold()

we only want to inhibit solar passthrough if the SoC is *below* the stop
threshold, not if it is equal to the stop threshold. otherwise, when
discharging, we would discharge until the battery reached the stop
threshold, then we would also inhibit solar passthrough, until the
battery is charged to the SoC stop threshold plus one percent.
2023-08-04 12:35:37 +02:00
helgeerbe
5335ec1bde Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-08-04 12:21:16 +02:00
Thomas Basler
43cba67531 Fix: Virtual console scrambled output when the output came from different contexts 2023-08-03 22:16:29 +02:00
Thomas Basler
0bdee6ec99 Fix: Prevent access to nullptr object when reconnecting to mqtt
It could occour when saving the settings via the web ui
2023-08-03 18:46:28 +02:00
Bernhard Kirchen
81864b3420
execute MQTT client synchronously in main loop() (#350)
processing a published valued on a subscribed topic is currently running
in a task that is not the task executing the main loop(). that's because
the espMqttClient(Secure) was constructed without arguments, which
selects the constructor with two arguments priority and core, both of
which have default values. that constructor selects
espMqttClientTypes::UseInternalTask::YES, causing a task to be created
in which context the MQTT client loop is executed.

MQTT subscribers assume they are running in the same context as the main
loop(). most code assumes exactly that. as the scheduler is preemptive
and very little (none at all?) code is interlocked, we have to make sure
to meet the programmer's expectations.

this changeset calls the MQTT client loop in the context of the main
loop() and enforces the use of espMqttClientTypes::UseInternalTask::NO.
2023-08-01 09:20:04 +02:00
Bernhard Kirchen
2bce8311a7
MQTT verbose logging fixes (#341)
* MQTT verbose logging: fix typo

this typo caused that verbose logging was always disabled for MQTT and
could not be enabled.

* webapp status: show MQTT verbose logging setting
2023-07-31 14:16:35 +02:00
Bernhard Kirchen
6b425d96b0
PowerMeter fixes (#342)
* PowerMeter: gracefully handle non-float MQTT values

* PowerMeter: update _lastPowerMeterUpdate conservatively

update the timestampt only if the topic actually matched any
subscription and if the value could be parsed as a float.

* PowerMeter: unsubscribe before subscribing

* PowerMeter: organize subscriptions in a map

this allows for a slightly more elegant code and reduced amount of code
overall.

* PowerMeter: clean up header

* move private methods to private section of class declaration.
* remove unused member variable.
2023-07-31 14:16:06 +02:00
helgeerbe
2440028d38 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-07-24 13:16:15 +02:00
MalteSchm
18c464e524
SoC based threshold detection fix (#320) 2023-07-24 13:03:12 +02:00
Martin Dummer
8bfa7e530c Feature: Admin AccessPoint Timeout now configurable
Make the administrative accesspoint timeout configurable. The default
value is 3 minutes, values from 0-99999 are possible, where 0 means
infinite (no timeout).

Signed-off-by: Martin Dummer <martin.dummer@gmx.net>
2023-07-22 18:14:07 +02:00
Thomas Basler
a68c553d27 Code formatting without functional changes 2023-07-22 18:07:03 +02:00
Thomas Basler
658a42db80 Apply code formatter without functional changes 2023-07-22 18:00:41 +02:00
Thomas Basler
bf4dc56cb8 Fix: Reboot loop if negative display pins and type where provided
Fix #1163
2023-07-21 19:02:18 +02:00
Thomas Basler
9dbeec3a31 Fix: Set WiFi setScanMethod and setSortMethod also on first connect 2023-07-20 23:44:09 +02:00
Phantomias2006
e06740fbb8
Add data age at battery MQTT (#322)
* Add data age at battery MQTT

* Update README.md

typo

* Update MQTT_Topics.md

typo

* Update PylontechCanReceiver.cpp

typo
2023-07-19 09:47:37 +02:00
Bernhard Kirchen
f0def2ae89
Selective verbosity (#318)
* DPL: implement verbose logging switch

* MQTT: implement verbose logging switch

* power meter: implement verbose logging switch

* Hoymiles lib: implement verbose logging switch

* cpp linting: "final" makes "virtual" and "override" redundant

... however, using only "final" is not as verbose.
2023-07-18 09:57:03 +02:00
Phantomias2006
a7da000345
Feature: set Huawei offline parameters via MQTT (#315)
* Add Huawei offline parameters via MQTT

* Update README.md

Correction of the docu

* Update MQTT_Topics.md

Correction of the docu
2023-07-18 09:52:31 +02:00
Martin
c393e52185
Feature: add Home Assistant MQTT discovery for Pylontech battery (#314)
When OpenDTU has a Pylontech CAN Bus Battery connected and enabled, this
patch adds the discovery routine for Home Assistant

Signed-off-by: Martin Dummer <martin.dummer@gmx.net>
2023-07-17 09:50:58 +02:00
Bernhard Kirchen
cbc99d715f
DPL: increase backoff while inverter is kept shut down (#310)
if the new calculated power limit is below the minimum power limit
setting, the inverter is shut down. the shutdown() function is called
every time this condition is detected, which is also true if the
inverter is kept shut down for longer. that happens while the battery
is charging in particular (solar passthrough off). there are other
cases.

in such cases we still want to get into the DPL status "stable". to be
able to determine this stable state, we must know if the call to
shutdown did actually initiate a shutdown or if the inverter is already
shut down.

we then can forward this "changed" or "not changed" info up the call
chain, where the loop() will know that the system is actually stable.
2023-07-17 09:40:18 +02:00
helgeerbe
633ef88296 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-07-12 13:45:19 +02:00
Bernhard Kirchen
f3297930b5
DPL: account for solar passthrough losses (#307)
* fix another fixable "passtrough" typo

the typo in the config's identifier is not changed to preserve
compatibility while not spending the effort to migrate the setting.

* webapp language: prefer SoC over SOC

* DPL: implement solar passthrough loss factor

in (full) solar passthrough mode, the inverter output power is coupled
to the charge controler output power. the inverter efficiency is already
accounted for. however, the battery might still be slowly discharged for
two reasons: (1) line losses are not accounted for and (2) the inverter
outputs a little bit more than permitted by the power limit.

this is undesirable since the battery is significantly drained if solar
passthrough is active for a longer period of time. also, when using full
solar passthrough and a battery communication interface, the SoC will
slowly degrade to a value below the threshold value for full solar
passthrough. this makes the system switch from charging the battery
(potentially rapidly) to discharging the battery slowly. this switch
might happen in rather fast succession. that's effectively
trickle-charging the battery.

instead, this new factor helps to account for line losses between the
solar charge controller and the inverter, such that the battery is
actually not involved in solar passthrough. the value can be increased
until it is observed that the battery is not discharging when solar
passthrough is active.
2023-07-12 13:20:37 +02:00
MalteSchm
95d7ac7adf
Disable debug mode, increasing power threshold for active channel detection (#301) 2023-07-12 13:19:24 +02:00
Thomas Basler
b8c75b02a0 Merge branch 'pr1003' into dev 2023-07-10 19:11:54 +02:00
Stephan
1871a9a692 use FSPI for esp32-c3 and revise device profiles 2023-07-10 19:04:13 +02:00
Thomas Basler
fe3d6588bc Feature: Turn off LED 1 if no inverters are enabled for polling
This means that e.g. at night, when polling at night is disabled, LED 1 will be turned off now.
2023-07-10 18:31:04 +02:00
Martin
cdf5c85510
fix: Home Assistant MQTT-Auto-Discovery with VE.Direct (#297)
In Home Assistant, when Home Assistant MQTT-Auto-Discovery is active,
almost all Sensors of the auto-discovered Victron device in Home
Assistant become "unavailable" after a short time - except those
Sensors with frequent changes like battery voltage or panel voltage.

This patch introduces regular mqtt updates for all VE.Direct sensors
when MQTT-Auto-Discovery is enabled.

Signed-off-by: Martin Dummer <martin.dummer@gmx.net>
2023-07-09 17:08:50 +02:00
Bernhard Kirchen
23ff4ef22a
DPL: do not use nullptr when printing debug messages (#303) 2023-07-09 16:42:50 +02:00
helgeerbe
2a858e096b fix: typo 2023-07-07 17:22:04 +02:00
helgeerbe
344498d440 fix: linting error 2023-07-04 14:55:55 +02:00
Bernhard Kirchen
107182f948
DPL: check more requirements and fix backoff initialization (#290)
* DPL: wait for valid time information

we know that the Hoymiles library refuses to send any message to any
inverter until the system has valid time information. until then we can
do nothing, not even shutdown the inverter.

* DPL: wait for device info to be ready

a calculated power limit will always be limited to the reported
device's max power. that upper limit is only known after the first
DevInfoSimpleCommand succeeded. wait for that information to be
available.

* DPL: fix initial calculcation backoff

if the calculation backoff is initialized to zero, the backoff will be
doubled to zero until a new, different power limit was calculated for
the first time. this lead to the DPL recalculating a power limit
hundreds of times without a backoff after startup.
2023-07-04 12:05:10 +02:00
Bernhard Kirchen
e457ab73f9
Fix vedirect polling (#291)
* VE.Direct: remove polling interval

the polling interval was meant to limit the amount of MQTT updates.
however, that is already controlled by the global MQTT publish interval.
the removed interval was instead used to limit polling of the VE.Direct
UART for incoming data.

the Victron device sends data unsolicited. the VeDirectFrameHandler does
not implement any polling mechanism. no data is ever sent to the Victron
device.

what the removed polling interval did was cause a buffer overrun of the
HardwareSerial class, since the incoming data was not processed in time.
so every five seconds, we read a whole valid VE.Direct frame, plus some
old data, which was not a whole frame, leading to VE.Direct error
messages to pop up.

with the polling interval removed, no framing errors are reported, and
instead we gain new data from the charge controller approximately ever
two seconds -- for free.

* VE.Direct: change texts to correct VE.Direct capital letters

* VE.Direct: improve "UpdatesOnly" switch labels

especially since the publish interval setting is gone, the label makes
it hard to comprehend what the switch does. update the texts to better
explain what the switch is used for.

use the same text on the VE.Direct info view.

* VE.Direct: use StatusBadge on info view

there were custom badges to indicate the VE.Direct settings. replace
those by the common StatusBadge to make then look the same as the other
badged on the info views.
2023-07-04 12:04:38 +02:00
helgeerbe
006f63ed02 feature: add digest auth on power meter
Power Meter -> HTTP(S) + Jason configuration allows now basic and digest authentication (all Shelly Gen2 devices)
2023-07-04 11:54:46 +02:00
helgeerbe
9a4eb75160 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-07-02 14:32:12 +02:00
helgeerbe
1f39ed7b9b Merge branch 'pr/MalteSchm/288' into development 2023-07-02 14:28:51 +02:00
helgeerbe
afd8790c3c Merge branch 'pr/schlimmchen/287' into development 2023-07-02 14:20:25 +02:00
Bernhard Kirchen
99876d7c6b
DPL: fix the configured upper limit not being respected (#286)
the requested newPowerLimit was indeed limited to the configured maximum
inverter output and the result was stored in effPowerLimit. later,
however, effPowerLimit must be scaled up (if necessary), not
newPowerLimit. the latter variable is not respecting the configured
maximum inverter output.
2023-07-02 14:11:44 +02:00
Bernhard Kirchen
097d464bbb
DPL: use vedirect isdatavalid (#283)
* DPL: use VeDirect.isDataValid()

in case the communication to the Victron charger is disrupted, the
respective values in VeDirect.veFrame are not invalidated such that we
would notice a problem. instead, isDataValid() should be used to make
sure that the Victron charger is actually alive and that we can trust to
use the reported values.

* DPL: simplify canUseDirectSolarPower return statement
2023-07-02 14:10:47 +02:00
MalteSchm
e279ce08c4 Dynamic power control and more power control modes on the Huawei PSU 2023-07-01 12:37:55 +02:00
Bernhard Kirchen
9aeb1583b5 DPL: consider the system stable when reusing the old limit
a new status is needed to communicate that no update was sent to the
inverter because its power limit is still valid. in this case,
calculating a new power limit is delayed by an exponentially increasing
backoff. the maximum backoff time is ~1s, which is still plenty fast.

the backoff is actually necessary for another reason: at least
currently, a lot of debug messages are printed to the console. printing
all that information in every DPL loop() is too much.
2023-06-30 21:00:51 +02:00
Bernhard Kirchen
461fce8ff4 DPL: do not repeat being disabled 2023-06-30 21:00:51 +02:00
Bernhard Kirchen
9bab740c43 DPL: replace _plState enum with a simple boolean switch 2023-06-30 21:00:51 +02:00
Bernhard Kirchen
b2d58af5e8 DPL: separate unconditional solar passthrough mode
the unconditional solar passthrough mode, configured using MQTT, works
differently than the normal mode of operation. it is also independent
from the power meter reading. if this mode is active, a shortcut is
taken to a function that implements the actions for this mode. this is
convenient since we don't have to consider special cases in the code
that handles normal mode of operation.
2023-06-30 21:00:51 +02:00
Bernhard Kirchen
71079fa0cc DPL: work on internal copy of pointer to inverter
the DPL already took care to shut down the inverter if anything fishy
was going on, mainly to make sure that the battery is not drained.
however, some cases were missed:

* if the configuration changed such that another inverter is now
  targeted, the one the DPL controlled previously was not shut down.
* if the configuration changed such that another inverter (different
  serial number) was configured at the same index, the previous one
  was not shut down.

this change corrects these problems by making the DPL keep a copy of the
shared_ptr to the inverter. the shared_ptr is only released once the DPL
shut the respective inverter down.
2023-06-30 20:04:39 +02:00
Bernhard Kirchen
2970e84193 DPL requirement: disabled inverter commands
if the inverter is not configured to be sent commands to, the DPL is
unable to control it, so the loop is aborted.
2023-06-30 20:04:39 +02:00
Bernhard Kirchen
18b1076660 DPL: improve responsiveness
this implementation checks all requirements for a new power limit to be
calculated, one after the other. if any requirement is not met, a
respective status is announced.

status messages are communicated on the (serial) console. these can also
be displayed easily on the web app in the future. the status texts
explain clearly what the DPL is currently doing, which aids
understanding how the DPL works. the status is only announced if it
changes, or after a fixed interval.

as each requirement is checked individually, the code readability is
improved as well. previously, all the respective conditions had to be
checked as well, but the statements were more complex.

the DPL loop is now executed with high frequency, i.e., it does not wait
for a fixed timespan to pass before checking requirements. it always
aborts on the first unmet requirement. this should improve responsiveness,
as the DPL checks all requirements more often.

the DPL now waits for all power commands and power limit updates to
complete. when that is the case, a settling time elapses. after the
settling phase, the DPL waits for a new update from the inverter and
from the power meter. now it can be assumed that the values are in sync.
it then makes sense to calculate a new power limit immediately, which
the DPL then does.
2023-06-30 20:04:39 +02:00
Bernhard Kirchen
0b0bcf1dfb fix typo: getLastRequestedPowe*w*rLimit() 2023-06-30 20:04:39 +02:00
Martin
8433820529
Fix typo in error messages (#280)
Signed-off-by: Martin Dummer <martin.dummer@gmx.net>
2023-06-29 13:06:28 +02:00
helgeerbe
0caffe9411 fix: Allow use GPIO0 as onBattery pins 2023-06-29 13:04:35 +02:00
Bernhard Kirchen
d6163ddb7d
set default values for pin mappings if not provided (#275) 2023-06-26 11:57:29 +02:00
Bernhard Kirchen
07bb0b03f7
DPL hysteresis fix and refactor of setNewPowerLimit() (#264) 2023-06-26 11:52:33 +02:00
Bernhard Kirchen
9995c1172e
VE.Direct live view enhancements (#269)
* add calculated values to VE.Direct data

solar current, battery output power, and the charger's efficiency can be
calculated from the values reported by the charger. the efficiency must
be taken with a grain of salt. it seems that the solar power value and
the battery output voltage/current are not always in sync. for that
reason a moving average is used to smooth out the calculated efficiency
value.

* show calculated VE.Direct values in web live view

order the values and translations similarly for the input and output,
starting with power at the top, then voltage, then current as the last
of these three.

* VE.Direct live view: use 'd' as unit for days

'd' is the SI unit symbol for days and does not need translation, which
is desirable as units are not translated throughout the project.

* refactor VE.Direct live view

* move Dynamic Power Limiter data into its own type.
* split VE.Direct data into three types: "device", "input", and
  "output". hence all input and output values are now ValueObject, which
  allows to iterate over them using a loop without typing issues.
* generate the tables with input and output values using a loop, rather
  than defining each row individually.
* localize numbers using $n (vue method), which fixes switching the
  number format (dot vs. comma) when switching the language.
* use no decimal point for power values (they are integers), three
  decimal points for kWh values (charger only reports two decimal
  places, but three are easier to read since the unit is *kilo* Wh), one
  decimal point for the efficiency, and two for voltage and current.
* update language tokens to avoid mapping JSON keys to language keys
  (use the JSON keys to access the language tokens).
* re-structure language tokes so the brief keys took over from
  VeDirectFrameHandler always make sense (nest into "input" and
  "output").
* order values similarly from top to bottom: power, then voltage, then
  current. this is following the order of the inverters' details.
* group values by type/unit (yield and max. power) and order them
  "newest" to "oldest" from top to bottom.
* increase the DynamicJsonDocument as it was too small to hold the newly
  added data.

* update webapp_dist to include VE.Direct live view refactoring
2023-06-22 21:32:20 +02:00
Bernhard Kirchen
016e30ec00
DPL: fix efficiency calculation (#270)
there is no need to assume and hardcode a fixed efficiency for the
Victron solar charger. the charger reports the voltage and current at
its battery terminal, which can be used to calculate the charger's
actual power output.

the fallback to 100% for the efficiency of the Hoymiles inverter, in
case it is not producing power, is too optimistic. this commit proposes
to use 96.7% as the efficiency for that case, which is the peak
efficiency for many (all?) Hoymiles inverters as per datasheet. that
value should be closer to the real efficiency that will be achieved once
the inverter is turned on.
2023-06-22 21:30:33 +02:00
helgeerbe
cd1db49a98 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-06-22 21:14:12 +02:00
Thomas Basler
93057fc3dc Feature: Added touch icon for iOS and Android
Implements #1060
2023-06-21 22:44:18 +02:00
Thomas Basler
e8fee49dc8 Allow the non-existence of the HOYMILES_PIN_ defines 2023-06-21 19:59:35 +02:00
Thomas Basler
30fbd98274 Fix: Reboot loop occoured when no rf module was configured 2023-06-21 19:56:14 +02:00
helgeerbe
fd58ad2003 feat(add ability to do a polite power meter read): 2023-06-14 16:21:58 +02:00
helgeerbe
080a3eb29e Merge branch 'PM_onDemand' into development 2023-06-14 13:22:19 +02:00
helgeerbe
da7628dafc Fix: Respect minimum on demand poll rate for power meter 2023-06-14 13:21:50 +02:00
helgeerbe
ceb28030a4 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-06-14 13:02:00 +02:00
helgeerbe
ded5ceec58 Fix: Make power limiter intervall configurable
Allows to change the power limiter intervall settings in the config file.
2023-06-14 12:49:54 +02:00
helgeerbe
86ee7e1a64 perf(PowerMeter): query PowerMeter on demand
In addition to the cyclic query of the power meters, they will be queried on demand when total power is requested and last update is older than 1 second.
2023-06-14 11:25:54 +02:00
Dominic Michel
3562e85b5e Change metric type back to gauge 2023-06-13 20:59:24 +02:00
helgeerbe
8dac88e7b9 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-06-12 13:07:44 +02:00
helgeerbe
0fd7b75e83 Fix(Power Limiter): hysteresis is not repected properly 2023-06-12 13:06:31 +02:00
Thomas Basler
08f47c2f4c Fix: Prometheus syntax error with wifi_bssid
Fixes #1021
2023-06-11 20:04:23 +02:00
helgeerbe
e68baa3086 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-06-09 13:16:56 +02:00
MalteSchm
e0a8da84d7 full solar passthrough 2023-06-09 13:09:58 +02:00
Thomas Basler
88cb59d177 Feature: Publish BSSID via prometheus 2023-06-08 19:57:07 +02:00
Thomas Basler
b3e41c957b Feature: Publish BSSID via MQTT 2023-06-08 19:56:44 +02:00
Thomas Basler
91d3cd1da2 Feature: Show BSSID in the web interface 2023-06-08 19:56:22 +02:00
Thomas Basler
721f82a17c Added additional exception handler to also show unknown exceptions in live data api endpoint 2023-06-08 19:39:56 +02:00
Thomas Basler
3b6c529efb Fix: Do not publish leading blanks in MQTT payload
Fixes #1011
2023-06-07 17:58:31 +02:00
helgeerbe
8298a0c36f
Merge pull request #255 from madmartin:inverter_restart
Feature: add daily restart for the inverter
2023-06-05 10:10:14 +02:00
Martin Dummer
c727e21a49
Feature: add daily restart for the inverter
Add a configurable restart option for the inverter to set the "YieldDay"
values to zero.

Signed-off-by: Martin Dummer <martin.dummer@gmx.net>
2023-06-04 09:14:42 +02:00
helgeerbe
91ce844b36 fix(linter warining): use snprintf istead of strcopy 2023-06-02 13:12:42 +02:00
MalteSchm
e7c8a89bd3 inital version of full solar passthrough
Webinterface change to set full solar passthrough values

Adding webapi and config changes to enable full solar passthrough over certain battery Soc

inital version of full solar passthrough in power limiter

Passthrough mode can be enabled via MQTT

translations

re-enable comment

remove unused variable
2023-06-02 12:49:24 +02:00
Thomas Basler
7f267ff2fb Fix: Lint Error: Almost always, snprintf is better than strcpy 2023-06-01 23:30:13 +02:00
Thomas Basler
5a37948ca9 Fix: If no sunset/sunrise calculation is possible a wrong value is shown
This is catched now and a proper message is shown in the web UI. Also the mode is set to day.
2023-06-01 18:39:50 +02:00
Thomas Basler
24f063dd7b Fix: Prevent partly calculated total data in web ui and display
Leads to zeros where no zeros should be.
2023-05-30 22:10:27 +02:00
Thomas Basler
1c8bd8091b Feature: Allow reordering of the inverters in the live view
Reordering can be done in the inverter settings via drag&drop.
2023-05-29 20:17:07 +02:00
Thomas Basler
e7198073af Feature: Allow configuration of sunset type 2023-05-24 19:21:44 +02:00
Martin
52af52eb3a
Pylontech enhancement (#239) 2023-05-24 09:17:38 +02:00
helgeerbe
a3e7439181 fix(action): sort tags in chronological order 2023-05-24 09:13:04 +02:00
Thomas Basler
752362d2df Feature: Added localization setting to display
Its possible to change the language of the display
2023-05-23 18:25:12 +02:00
helgeerbe
8b64671151 doc: warning, that only 5 inverters are supported at max 2023-05-23 11:04:56 +02:00
helgeerbe
13b318690d fix: linting errors 2023-05-23 10:24:06 +02:00
helgeerbe
47f81f2579 breaking change: Reduce maximum number of invertes to 5 to keep livedata working
livedata json is now calculated as 4096 * MaxInvertes
2023-05-23 10:15:37 +02:00
helgeerbe
b7ac70b1ca Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-05-23 09:19:57 +02:00
Thomas Basler
40820c07f2 Use the new data store in the graphic display class.
With this patch, the display turns off if no inverter is reachable anymore. Previously it turned off if the production was zero.
This fixes #933
2023-05-21 22:40:32 +02:00
Thomas Basler
cd98941c5d Implement global data store to handle all invert total values
Use the new values in the LED, MQTT and Web interface.
2023-05-21 22:37:33 +02:00
helgeerbe
1c7b7d3cdf Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-05-10 18:16:25 +02:00
Thomas Basler
efcbd81927 Feature: Add used PIO environment to the system info page 2023-05-08 21:43:50 +02:00
MalteSchm
065c169b20
Set initial PL state in init() to avoid inverter shutdown on reboot... (#224) 2023-05-08 13:25:02 +02:00
helgeerbe
178d40d5b4 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-05-04 20:24:29 +02:00
Thomas Basler
65b728eebb Fix: No OpenDTU startup of CDC (like Pico or ESP32-S3) devices if no usb host is connected
Should also fix #826
2023-05-03 21:16:27 +02:00
MalteSchm
569edbe69e
static casts set last requested limit for all cases where inverter power is changed (#213) 2023-05-01 21:20:49 +02:00
helgeerbe
8021052cfd PL remove debug messages 2023-04-29 22:53:50 +02:00