Commit Graph

112 Commits

Author SHA1 Message Date
Thomas Basler
f0b5542c2d BREAKING CHANGE: Web API Endpoint /api/livedata/status and /api/prometheus/metrics
Efficiency was moved from the AC section to the INV section
2024-01-30 22:29:25 +01:00
Thomas Basler
6b44694a12 Added frequency and command definitions for the 900 MHz band (North America) 2024-01-13 15:29:17 +01:00
Thomas Basler
58f0121c11 Create separate definition for the 860MHz band of the CMT2300A
This is required to support different countries in the future. The defines where moved to function to change the values dynamically
2024-01-13 14:48:23 +01:00
Thomas Basler
e95afbf2cc Use references instead of pointers whenver possible 2023-12-12 13:26:07 +01:00
Thomas Basler
8fb43fedf8 Add const keyword to methods 2023-12-12 01:30:40 +01:00
Thomas Basler
d6494fa791 Add const keyword to method parameters 2023-12-12 00:21:14 +01:00
Thomas Basler
47e905bcfc Add const statement to several variables 2023-12-11 19:54:57 +01:00
Thomas Basler
8cf31729df Adjusted inverter names for HMS-1600/1800/2000-4T 2023-11-24 18:11:08 +01:00
Thomas Basler
17e92fc5eb Feature: Support HMT-1600/1800/2000-4T 2023-11-07 18:34:37 +01:00
Thomas Basler
2ae8ed5e18 Doc: Add class description for inverters 2023-11-05 13:44:08 +01:00
Thomas Basler
0a4945ae39 Adjusted inverter names 2023-11-05 13:43:48 +01:00
Thomas Basler
21fb10f7f2 Feature: Add one channel HMS inverter with different byte assignment
Fix #1148
2023-09-14 23:58:08 +02:00
Thomas Basler
9ac6dd6e8d Feature: First very basic support to read the grid profile
The parser is still missing and requires community support to collect data.
2023-09-07 22:08:07 +02:00
Thomas Basler
ec9af886d5 Feature: Added option to set daily yield to zero at midnight 2023-09-05 20:27:52 +02:00
Thomas Basler
6127fbe940 Feature: Added option to set runtime values to zero when inverter becames unreachable 2023-09-02 12:22:22 +02:00
Thomas Basler
2c41be106e Feature: Allow setting of the Reachable Threshold per inverter 2023-09-01 19:17:12 +02:00
Bernhard Roth
6eb3c63288 Fix issue #1256 (HMS-2000-4T reactive power should be signed) 2023-08-21 11:14:24 +02:00
Thomas Basler
22d9b128b9 Fix: Move setting of CMD_PENDING state into the right order 2023-08-04 23:44:18 +02:00
Thomas Basler
be09c4052f Fix: Ensure that only completly assembled packets are put into the command queue 2023-08-02 22:41:53 +02:00
Thomas Basler
0ffbba0cf5 Fix: Allow sending of ChannelChangeCommand even if EnableCommands is disabled
This is required to successfull move the inverter to another frequency and then polling it. Without this command its not even possible to poll a inverter.

Fixes #1127
2023-07-10 18:30:59 +02:00
Thomas Basler
64c96c34f4 Revert "Fix: String numbers for HMT inverters are mirrored"
This reverts commit 593a33020f.
2023-06-14 21:44:55 +02:00
Thomas Basler
593a33020f Fix: String numbers for HMT inverters are mirrored
Fixes: #1005
2023-06-07 18:05:51 +02:00
Thomas Basler
fe90c863bf Fix: Better handling of invalid fragment ids 2023-05-23 19:32:51 +02:00
Thomas Basler
98da2b64e2 Rename FLD_PRA to FLD_Q 2023-04-24 22:29:59 +02:00
Thomas Basler
270a7f4933 Rename UNIT_VA to UNIT_VAR 2023-04-24 22:25:15 +02:00
Thomas Basler
f5c15a445b Move byteAssignment to stack (avoid container) to save heap 2023-04-22 01:12:29 +02:00
Thomas Basler
7c37d289c0 Enabled additional statistics data for HMT inverters
Not yet shown in web ui and mqtt
2023-04-15 10:55:48 +02:00
Thomas Basler
ac7b5dba11 Resend and Retransmit count is now implementable per command 2023-04-15 10:55:48 +02:00
Thomas Basler
f5767e61ef Implement CMD56 as own command.
By doing so, it's possible to send all packets via the sendEsbPacket method. A lot of stuff could be removed which is no more used.
2023-04-15 10:55:48 +02:00
Thomas Basler
67055276ca Implement different Eventlog messages for HMT inverters
Also make message list much more readable
2023-04-15 10:55:47 +02:00
Thomas Basler
dc91929d6e First rough implementation of HMT inverters 2023-04-15 10:55:47 +02:00
Thomas Basler
45882543b6 Allow dynamic pin mapping for CMT module 2023-04-15 10:55:47 +02:00
Thomas Basler
a7e9aaa862 Move reference to the radio instance into the inverter instance
This is required to support different radios for different inverters
2023-04-15 10:55:47 +02:00
Thomas Basler
c2e4c5d43e Added first implementation of HMS inverter classes 2023-04-15 10:55:47 +02:00
Thomas Basler
d6028cbd50 Remove not required F() macro. Frees ~20kb flash. 2023-04-04 18:51:18 +02:00
Thomas Basler
041249523e Fixed typo in comment 2023-03-28 22:41:27 +02:00
Thomas Basler
fa3d0370f0 Fix isReachable and isProducing based on PollEnabled 2023-02-18 23:50:16 +01:00
Thomas Basler
7da782c4ef Hoymiles Lib: Added flags to inverter to enable/disable polling and commands to the inverter 2023-02-18 15:51:46 +01:00
Thomas Basler
d4c838a16e BREAKING CHANGE: Prometheus API!
Added additional field to the prometheus api which identifies a channel by it's type. That means that e.g. channel 0  exists for type AC and DC.

This commit also introduces a additional field in the statistics byte assignment table. This field identifies whether a channel is on the AC or DC side. MQTT and WebAPI is still compatible with the previous design.
2023-02-06 19:51:10 +01:00
Thomas Basler
6b36369b06 Hoymiles Lib: Migrate byteAssign array to std::list 2023-02-06 19:44:00 +01:00
Thomas Basler
7c33688167 Use same line ending in printf as in println
This prevents mistakes in the webconsole
2023-01-04 18:48:33 +01:00
Thomas Basler
43d25dd24a Hoymiles Lib: Change field order and move channel to first position 2022-12-25 12:02:11 +01:00
Thomas Basler
1d650b59ae Hoymiles Lib: Add digits column to byteAssignment table
This allows to specify amount of digits for calculated fields
2022-12-25 12:02:11 +01:00
Thomas Basler
f689fedf4e Hoymiles Lib: Remove hard coded Serial output
The serial port for output of debug information can now changed during runtime
2022-12-19 20:52:12 +01:00
Thomas Basler
5feefed14e Added missing copyright information 2022-12-14 22:37:37 +01:00
Thomas Basler
dd7babb448 Added a timeout of 5ms to detect current time.
This prevents false positives when a interrupt occours during the reading of the time
2022-11-14 20:19:38 +01:00
Thomas Basler
27ed4e3cda BREAKING: Change power factor from percent value to value between 0 and 1
If you write these values to a database you have to update them.
2022-10-31 10:50:31 +01:00
Thomas Basler
f2a08ba503 Rename FLD_PCT to FLD_PF and assign UNIT_NONE 2022-10-31 00:43:07 +01:00
Thomas Basler
f741fea333 Move serial number formatting to inverter class 2022-10-29 11:22:56 +02:00
Thomas Basler
f21dd351ef Optimize performance by removing not required string constructors 2022-10-29 11:22:56 +02:00