Eugen
|
effd4e89ab
|
BF: get powerTotal from PowerMeter
|
2023-03-22 08:21:34 +01:00 |
|
Adminius
|
05a5b2367b
|
PowerMeter Class + SDM PowerMeter support
|
2023-03-21 23:46:54 +01:00 |
|
helgeerbe
|
19252629cb
|
minimum panel DC power 20W
|
2023-03-20 15:17:07 +01:00 |
|
helgeerbe
|
a6c852a82c
|
if new limit too low, turn inverter off
within state
|
2023-03-20 12:35:29 +01:00 |
|
helgeerbe
|
2dc7089aa6
|
Start at night
|
2023-03-19 22:53:24 +01:00 |
|
helgeerbe
|
b9acbe6f2c
|
off when newPowerLimit < lowerLimit
|
2023-03-18 23:50:34 +01:00 |
|
helgeerbe
|
06370baa0e
|
Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development
|
2023-03-18 22:42:05 +01:00 |
|
helgeerbe
|
c95468f972
|
fix comparison between int and double
|
2023-03-18 14:44:28 +01:00 |
|
Thomas Basler
|
75364f89cb
|
Publish all valid digits via mqtt
|
2023-03-16 19:29:37 +01:00 |
|
helgeerbe
|
46ce6ad50f
|
Implement battery drain strategies:
- empty when full
- empty at night
|
2023-03-16 17:48:22 +01:00 |
|
helgeerbe
|
32a96bbd06
|
change all watt related vars to
int32_t to avoid cast problems with negativ values.
|
2023-03-16 12:34:14 +01:00 |
|
helgeerbe
|
04c7e4fa01
|
fix cast error with unsigned int
which results in wrong power limit settings if values become < 0 due
to power export to the grid.
|
2023-03-16 12:17:14 +01:00 |
|
Thomas Basler
|
2e33f5cd51
|
Display: Implement rotation setting and removed icons
|
2023-03-15 20:20:14 +01:00 |
|
helgeerbe
|
9214897245
|
for watt use uint32_t as std type to
avoid cast problems to uint16_t
|
2023-03-13 11:38:26 +01:00 |
|
Bernhard Kaszt
|
e95acbec46
|
PylontechCanReceiver.cpp: Cosmetic changes
|
2023-03-12 18:47:29 +01:00 |
|
MalteSchm
|
63c956af15
|
swap can library to better support newer ESPs
|
2023-03-12 17:27:41 +01:00 |
|
helgeerbe
|
01a2ffaed5
|
[Request] Show actual power limiter state in live view helgeerbe/OpenDTU-OnBattery#134
|
2023-03-10 16:29:00 +01:00 |
|
helgeerbe
|
43dc10b868
|
Merge branch 'inverter-settings' into development
|
2023-03-09 12:43:03 +01:00 |
|
helgeerbe
|
8df2c16cce
|
ensure STATE_DISCOVER if PowerLimter is enabled
|
2023-03-09 10:22:08 +01:00 |
|
helgeerbe
|
418fea2cfc
|
fix veStruct
* PPV is int not double
* fix: initialize veStruct to 0 to avoid random data on startup
|
2023-03-09 10:16:55 +01:00 |
|
helgeerbe
|
6f3e33c0b1
|
exit loop after turn inverter on or off
|
2023-03-08 22:11:01 +01:00 |
|
Bernhard Kaszt
|
a66f818e75
|
Hide Victron Ve.direct UI elements from Live page when disabled
Resolves #91
|
2023-03-08 19:54:19 +01:00 |
|
Markus Dobel
|
9eff5f228b
|
feat: export panel settings (name, max power, offset) as prometheus metrics
|
2023-03-08 09:11:25 +01:00 |
|
helgeerbe
|
716fc867a1
|
powerLimiter with state machine
|
2023-03-07 21:04:19 +01:00 |
|
Bernhard Kaszt
|
06a0f76fed
|
Fix local build working but Github build failing
|
2023-03-05 20:45:27 +01:00 |
|
Bernhard Kaszt
|
06fbdf1f12
|
Add Pylontech battery to device pin manager
|
2023-03-05 19:55:56 +01:00 |
|
Bernhard Kaszt
|
304d90062d
|
Revert broken change in condition that sets _consumeSolarPowerOnly
6709338dbd
|
2023-03-05 16:30:53 +01:00 |
|
Bernhard Kaszt
|
a6e720f154
|
Powerlimiter: Remove MQTT Topic debug message
|
2023-03-05 15:41:21 +01:00 |
|
Bernhard Kaszt
|
804f225908
|
Fix _consumeSolarPowerOnly sometimes being set to false when it shouldn't
|
2023-03-05 13:32:18 +01:00 |
|
helgeerbe
|
b70407d7fe
|
Initilise variables
|
2023-03-04 13:02:30 +01:00 |
|
helgeerbe
|
9391b11403
|
fix start inverter
|
2023-03-04 11:59:10 +01:00 |
|
helgeerbe
|
b7dda83545
|
use efficiency factor if limit is set to
victronChargePower
|
2023-03-03 20:34:11 +01:00 |
|
helgeerbe
|
cf4a35e148
|
fix starting and stopping inverter
|
2023-03-03 19:51:04 +01:00 |
|
helgeerbe
|
6709338dbd
|
fix setting consumeSolarPowerOnly
|
2023-03-02 16:18:44 +01:00 |
|
helgeerbe
|
67a5217482
|
start inverter if power consumption greater or equal lower power limit
|
2023-03-02 14:27:42 +01:00 |
|
helgeerbe
|
3e38941b57
|
start inverter only if not exporting to grid
|
2023-03-01 13:34:27 +01:00 |
|
helgeerbe
|
6241a31e8c
|
comment out full wifi scan
|
2023-03-01 12:09:53 +01:00 |
|
helgeerbe
|
4a51ae5038
|
victron charge power is integer
|
2023-03-01 10:23:37 +01:00 |
|
helgeerbe
|
26a8809121
|
stop inverter, if exporting power to grid
|
2023-02-28 13:09:10 +01:00 |
|
helgeerbe
|
3b62d5708a
|
Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development
|
2023-02-27 07:42:46 +01:00 |
|
Thomas Basler
|
4d18ccf01d
|
Prometheus API: Only output the channels if they where read at least once
|
2023-02-26 19:31:37 +01:00 |
|
helgeerbe
|
e9fce49fee
|
fix lint error
|
2023-02-25 22:23:05 +01:00 |
|
helgeerbe
|
32342dcd5d
|
fix voltage threshhold to 2 decimal digits
|
2023-02-25 22:12:44 +01:00 |
|
helgeerbe
|
17dd9db946
|
set min target power consumption to 0
|
2023-02-25 20:17:25 +01:00 |
|
helgeerbe
|
3ed61319ad
|
fix config read for power consumption
|
2023-02-25 18:58:41 +01:00 |
|
helgeerbe
|
1e968a1713
|
Add target for power consumption
|
2023-02-25 16:28:21 +01:00 |
|
helgeerbe
|
3f3540bd33
|
print ve.direct rx, tx pins on init
|
2023-02-25 15:29:00 +01:00 |
|
Thomas Basler
|
c67b3e3cbd
|
Prometheus API: Set correct metrics type
|
2023-02-24 19:10:35 +01:00 |
|
helgeerbe
|
28b24d01ad
|
implement UI for target power consumption
|
2023-02-24 16:13:32 +01:00 |
|
helgeerbe
|
cd7ece7caf
|
fix hard coded channel settings
|
2023-02-24 10:45:59 +01:00 |
|