Commit Graph

2438 Commits

Author SHA1 Message Date
Bernhard Kirchen
cf1ea42f8b power limiter: remove obsolete enum 2024-04-15 23:02:58 +02:00
Thomas Basler
d0981934b0 webapp: add app.js.gz 2024-04-12 22:37:52 +02:00
Thomas Basler
68b1a9ee08 Remove no more required web server patch
By using the new ESPAsyncWebserver this patch is no more required as it is already included in the upstream repo
2024-04-12 20:53:36 +02:00
Thomas Basler
011f00e5de Fix: If unauthenticaed, the redirect to login page did not work 2024-04-12 20:38:28 +02:00
Thomas Basler
de156ef10a webapp: Fix lint errors 2024-04-12 20:34:30 +02:00
Thomas Basler
b58d08683e webapp: update dependencies 2024-04-12 20:02:18 +02:00
Thomas Basler
bf49410f6d Merge branch 'pr1909' into dev 2024-04-12 17:05:51 +02:00
Bernhard Kirchen
4c2822cdbc remove usage of F() macro
frees 888 Bytes of flash.
2024-04-12 15:33:47 +02:00
Bernhard Kirchen
153293e1c7 remove remaining usage of F() macro 2024-04-12 15:28:26 +02:00
Bernhard Kirchen
8b3a1bef47 Fix: show AC input power of Huawei AC charger in live view
makes the value match its description. since most values in the top part
of the live view are related to the AC side of the system, it makes
sense to use the correct value rather than to change the description.
2024-04-11 14:27:47 +02:00
Bernhard Kirchen
f634f58788 Fix: DPL: use correct channel type to get inverter efficiency 2024-04-11 08:28:49 +02:00
Bernhard Kirchen
a9c3e05f05 PowerMeter admin: URL examples to the top and hidden if disabled 2024-04-10 20:44:46 +02:00
PhilJaro
165a9bc168
adjust VE.Direct MPPT yield resulotion (#859) 2024-04-09 20:31:05 +02:00
eu-gh
0ed09aeb4c Feature: Huawei: add SoC stop threshold and verbose logging switch 2024-04-07 17:16:50 +02:00
SW-Nico
b9ad1e3054 VE.Direct: process more values and refactor variable names
* process "IL", "AR" and "MON"
* discard "BMV" and (unsolicited) History Data
* simplify isDataValid()
* veMpptStruct, veStruct: new, verbose variable names, including units,
  and replace floats (save values with original integer precision)
* comment on rollover situation in isDataValid()
2024-04-07 17:13:07 +02:00
Thomas Basler
ea28903761 Move parsing of serial from web request to separate method 2024-04-05 19:14:56 +02:00
Thomas Basler
980e847ccb Feature: Check for out of memory situations when sending json responses
Also shows a nice message in the frontend if an internal error occours
2024-04-05 19:14:56 +02:00
Thomas Basler
2e3125fe8d Feature: Migrated ArduinoJson 6 to 7 2024-04-05 19:14:56 +02:00
Thomas Basler
e7a9c96b72 Upgrade ESP Async WebServer from 2.8.1 to 2.9.0 2024-04-03 23:11:30 +02:00
Bernhard Kirchen
3934906001
Merge pull request #836 from helgeerbe/merge-v24.3.31
Merges v24.3.31 from upstream
2024-04-03 20:08:09 +02:00
Thomas Basler
aa10c2c5e1 Fix: Too small event_queue_size in AsyncTCP lead to wdt reset
Fix #1705
2024-04-03 19:12:08 +02:00
Thomas Basler
b55ca53d1d Fix: Setting DTU options was only possible once without reboot
Fix #1884
2024-04-03 18:35:27 +02:00
Bernhard Kirchen
21cdc69625 Feature: use VE.Direct "network total DC power"
1. makes the DPL use the power generated by all connected charge
   controllers for calculations based on solar passthrough.
2. makes the network total DC power appear as "MPPT Total Power" in the
   live view at the top.
3. shows the network total DC power in the VE.Direct live data card.
2024-04-03 16:33:15 +02:00
Bernhard Kirchen
6b8c93d2e6 polish VE.Direct HEX support
* show charge controller temperature in live view
* send hex requests right after decoding a frame. this seems to have the
  best chance of getting an answer to all requests.
* deem 0xFFFFFFFF value of network total DC power as invalid indicator.
  neither network state, nor network info, nor network mode seem to
  indicate that the charge controller is part of a VE.Smart network. for
  that reason, we revert to always querying the network total DC power
  value, but testing it for max(uin32_t) value, which seems to indicate
  that the charge controller is not part of a VE.Smart network.
* improve (verbose) logging, e.g., use _logId, and print names of
  response codes and known registers, always print error messages,
  add additional tests to prevent overly verbose messages.
* move hex protocol definitions to VeDirectData.h header
  and use enum classes
* define register addresses in enum class
* move values retrieved through hex protocol into main MPPT data struct
* do not send HEX requests if the serial interface cannot send data
* detect whether smart battery sense temperature is available
* web app: make all VE.Direct sub-cards iterable. this makes addind more
  values much simpler and saves a bunch of code in the web app.
* make VeDirectFrameHandler state a type-safe enum class
* unindent MPPT controller loop()
* whitespace cleanup
2024-04-03 16:33:15 +02:00
SW-Nico
aadd7303ac Feature: add support for VE.Direct hex messages 2024-04-03 16:33:15 +02:00
helgeerbe
ff44267e73 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into merge-v24.3.31 2024-04-03 11:53:03 +02:00
Bernhard Kirchen
8c6e925ca4 VE.Direct: make state machine timeout robust against overflow 2024-04-02 21:05:59 +02:00
Bernhard Kirchen
43f553d2d4 VE.Direct MQTT: simplify code
the use of a #define is warranted here since it saves a lot of code
duplication and improves code readability.
2024-04-02 21:05:59 +02:00
Bernhard Kirchen
92a7f27919 VE.Direct: use float rather than double
double precision floating point numbers are not needed to handle
VE.Direct values. handling double is implemented in software and hence
*much* more resource intensive.
2024-04-02 21:05:59 +02:00
Bernhard Kirchen
b299b9dc6c VE.Direct: simplify access to data
hand out const& to the data structs. this is possible now that this
struct is "stable", i.e., not reset regularly.
2024-04-02 21:05:59 +02:00
Bernhard Kirchen
ad125ea804 Fix: properly handle fragmented VE.Direct messages
queue every text event until the frame was checked by it checksum. then
process the data directly into the buffer struct. do not clear the
buffer struct, so it will always include the most recent value of a
particular data point.
2024-04-02 21:05:59 +02:00
Bernhard Kirchen
187f197e32 Feature: add unique prefix to VE.Direct messages 2024-04-02 21:05:59 +02:00
MalteSchm
8abf614047 Feature: BMS initiated emergency charging
This change logically connects the AC-Charger with the BMS to add BMS
initiated emergency charging and respecting BMS current limits.
2024-04-02 21:05:00 +02:00
Thomas Basler
d2d775d687 Update espressif32 from 6.5.0 to 6.6.0 2024-04-02 19:58:42 +02:00
PhilJaro
da96273085
Fix typo in German locale (#831) 2024-04-02 12:05:45 +02:00
Thomas Basler
718690030e Fix include for TimeoutHelper 2024-04-01 13:52:59 +02:00
Thomas Basler
8add226a7c Save flash: Move WebApi json parsing to separate method to prevent a lot of redundant code 2024-04-01 13:52:09 +02:00
Thomas Basler
58efd9e954 Move source files for ThreadSafeQueue to correct directories 2024-04-01 00:03:04 +02:00
Thomas Basler
6940418955 Move source files for TimeoutHelper to correct directories 2024-04-01 00:00:36 +02:00
Thomas Basler
12588655df webapp: add app.js.gz 2024-03-31 23:07:08 +02:00
Thomas Basler
bdff1e1ac3 Added github workflow to do some repository cleanup 2024-03-31 22:39:59 +02:00
Thomas Basler
f0a8cabc2c webapp: update dependencies 2024-03-31 14:31:57 +02:00
Thomas Basler
1888054627 Fix: Re-Request grid profile parameters if received data are invalid / to short
Fixes #1874
2024-03-31 12:42:00 +02:00
Thomas Basler
6f3b8fb8e1 Fix: Change default NTP server
Fixes #1877
2024-03-31 12:27:27 +02:00
Bernhard Kirchen
91a0992964 fix: VE.Direct MPPT data not always updated in websocket
set the "last published" timestampt after handling *all* MPPTs.
2024-03-26 20:48:39 +01:00
Rene
eff8d52014 better alignment inverter, issue 360 2024-03-25 22:42:22 +01:00
David von Oheimb
811b64adb5 PowerLimiter.cpp: simplification and minor correction of logic table comments 2024-03-25 10:55:00 +01:00
Bernhard Kirchen
06f39f8396 Merge remote-tracking branch 'tbnobody/master' into development 2024-03-23 22:58:21 +01:00
Bernhard Kirchen
12f7caf998 fix: HTTP power meter: retrieve multiple JSON paths
if only a single request was made (switch "Individual HTTP requests per
phase" is off), the user could still enable phase 2 and phase 3 config
and configure a respective JSON path. however, the value was never
extracted from the successful HTTP request for phase 1.

closes #637.
2024-03-23 22:13:59 +01:00
Bernhard Kirchen
b8d0998a49 HTTP power meter: refactor tryGetFloatValueForPhase
unindent code, prepare this method for re-use on the same HTTP response
but with a different JSON path.
2024-03-23 22:13:59 +01:00