Commit Graph

91 Commits

Author SHA1 Message Date
helgeerbe
eb1c2dbd8c Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-09-12 19:27:32 +02:00
Thomas Basler
ec9af886d5 Feature: Added option to set daily yield to zero at midnight 2023-09-05 20:27:52 +02:00
Bernhard Kirchen
ba303da742
VE.Direct: Reset state machine on timeout, fix and extend logging (#416)
* VE.Direct: reset state machine on timeout

there will never be a large gap between two bytes of the same frame.
if such a large gap is observed, reset the state machine so it tries
to decode a new frame once more data arrives.

this is helpful in case of corrupted data that prevents the state
machine of transitioning to the final state even though the VE.Direct
data producer is done sending bytes that belong to the same frame.

* VE.Direct: print problems to MessageOutput

this includes the web console in particular, where many users have
access to while the serial console is not attached or monitored.

* VE.Direct: collect serial input into buffer and print

should help debug issues for users.

* VE.Direct: implement and use verbose logging switch
2023-09-04 14:07:48 +02:00
Thomas Basler
abf95634db Replace platform dependent variable types by platform independent 2023-09-03 23:27:53 +02:00
Thomas Basler
6127fbe940 Feature: Added option to set runtime values to zero when inverter becames unreachable 2023-09-02 12:22:22 +02:00
Thomas Basler
2c41be106e Feature: Allow setting of the Reachable Threshold per inverter 2023-09-01 19:17:12 +02:00
Thomas Basler
c5f9f460cd Feature: Added config option to change MQTT CleanSession Flag 2023-09-01 18:03:30 +02:00
Bernhard Kirchen
f744629b0b
Support for Jikong JK BMS using serial connection (#319) 2023-08-31 16:21:32 +02:00
helgeerbe
43e836ac41 resolve merge conflict with upstream/master 2023-07-24 13:23:50 +02:00
helgeerbe
2440028d38 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-07-24 13:16:15 +02:00
Martin Dummer
8bfa7e530c Feature: Admin AccessPoint Timeout now configurable
Make the administrative accesspoint timeout configurable. The default
value is 3 minutes, values from 0-99999 are possible, where 0 means
infinite (no timeout).

Signed-off-by: Martin Dummer <martin.dummer@gmx.net>
2023-07-22 18:14:07 +02:00
Thomas Basler
736220c80d Reorder config struct components 2023-07-22 17:28:58 +02:00
Bernhard Kirchen
f0def2ae89
Selective verbosity (#318)
* DPL: implement verbose logging switch

* MQTT: implement verbose logging switch

* power meter: implement verbose logging switch

* Hoymiles lib: implement verbose logging switch

* cpp linting: "final" makes "virtual" and "override" redundant

... however, using only "final" is not as verbose.
2023-07-18 09:57:03 +02:00
Bernhard Kirchen
f3297930b5
DPL: account for solar passthrough losses (#307)
* fix another fixable "passtrough" typo

the typo in the config's identifier is not changed to preserve
compatibility while not spending the effort to migrate the setting.

* webapp language: prefer SoC over SOC

* DPL: implement solar passthrough loss factor

in (full) solar passthrough mode, the inverter output power is coupled
to the charge controler output power. the inverter efficiency is already
accounted for. however, the battery might still be slowly discharged for
two reasons: (1) line losses are not accounted for and (2) the inverter
outputs a little bit more than permitted by the power limit.

this is undesirable since the battery is significantly drained if solar
passthrough is active for a longer period of time. also, when using full
solar passthrough and a battery communication interface, the SoC will
slowly degrade to a value below the threshold value for full solar
passthrough. this makes the system switch from charging the battery
(potentially rapidly) to discharging the battery slowly. this switch
might happen in rather fast succession. that's effectively
trickle-charging the battery.

instead, this new factor helps to account for line losses between the
solar charge controller and the inverter, such that the battery is
actually not involved in solar passthrough. the value can be increased
until it is observed that the battery is not discharging when solar
passthrough is active.
2023-07-12 13:20:37 +02:00
Bernhard Kirchen
e457ab73f9
Fix vedirect polling (#291)
* VE.Direct: remove polling interval

the polling interval was meant to limit the amount of MQTT updates.
however, that is already controlled by the global MQTT publish interval.
the removed interval was instead used to limit polling of the VE.Direct
UART for incoming data.

the Victron device sends data unsolicited. the VeDirectFrameHandler does
not implement any polling mechanism. no data is ever sent to the Victron
device.

what the removed polling interval did was cause a buffer overrun of the
HardwareSerial class, since the incoming data was not processed in time.
so every five seconds, we read a whole valid VE.Direct frame, plus some
old data, which was not a whole frame, leading to VE.Direct error
messages to pop up.

with the polling interval removed, no framing errors are reported, and
instead we gain new data from the charge controller approximately ever
two seconds -- for free.

* VE.Direct: change texts to correct VE.Direct capital letters

* VE.Direct: improve "UpdatesOnly" switch labels

especially since the publish interval setting is gone, the label makes
it hard to comprehend what the switch does. update the texts to better
explain what the switch is used for.

use the same text on the VE.Direct info view.

* VE.Direct: use StatusBadge on info view

there were custom badges to indicate the VE.Direct settings. replace
those by the common StatusBadge to make then look the same as the other
badged on the info views.
2023-07-04 12:04:38 +02:00
helgeerbe
006f63ed02 feature: add digest auth on power meter
Power Meter -> HTTP(S) + Jason configuration allows now basic and digest authentication (all Shelly Gen2 devices)
2023-07-04 11:54:46 +02:00
MalteSchm
e279ce08c4 Dynamic power control and more power control modes on the Huawei PSU 2023-07-01 12:37:55 +02:00
MalteSchm
e0a8da84d7 full solar passthrough 2023-06-09 13:09:58 +02:00
helgeerbe
8298a0c36f
Merge pull request #255 from madmartin:inverter_restart
Feature: add daily restart for the inverter
2023-06-05 10:10:14 +02:00
Martin Dummer
c727e21a49
Feature: add daily restart for the inverter
Add a configurable restart option for the inverter to set the "YieldDay"
values to zero.

Signed-off-by: Martin Dummer <martin.dummer@gmx.net>
2023-06-04 09:14:42 +02:00
MalteSchm
e7c8a89bd3 inital version of full solar passthrough
Webinterface change to set full solar passthrough values

Adding webapi and config changes to enable full solar passthrough over certain battery Soc

inital version of full solar passthrough in power limiter

Passthrough mode can be enabled via MQTT

translations

re-enable comment

remove unused variable
2023-06-02 12:49:24 +02:00
Thomas Basler
1c8bd8091b Feature: Allow reordering of the inverters in the live view
Reordering can be done in the inverter settings via drag&drop.
2023-05-29 20:17:07 +02:00
Thomas Basler
e7198073af Feature: Allow configuration of sunset type 2023-05-24 19:21:44 +02:00
Martin
52af52eb3a
Pylontech enhancement (#239) 2023-05-24 09:17:38 +02:00
helgeerbe
a3e7439181 fix(action): sort tags in chronological order 2023-05-24 09:13:04 +02:00
Thomas Basler
752362d2df Feature: Added localization setting to display
Its possible to change the language of the display
2023-05-23 18:25:12 +02:00
helgeerbe
47f81f2579 breaking change: Reduce maximum number of invertes to 5 to keep livedata working
livedata json is now calculated as 4096 * MaxInvertes
2023-05-23 10:15:37 +02:00
helgeerbe
40cee1f9ca Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-04-17 11:08:55 +02:00
Thomas Basler
371e405eed Added configuration of CMT modules frequency to webapp 2023-04-15 10:55:48 +02:00
Thomas Basler
854fcdaeae Allow configuration of the TX PA Level of the CMT2300A module 2023-04-15 10:55:48 +02:00
Thomas Basler
dc91929d6e First rough implementation of HMT inverters 2023-04-15 10:55:47 +02:00
helgeerbe
1dc73f91ee Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-04-13 10:18:49 +02:00
Martin Dummer
bea0a738c1
include/Configuration.h: rename MQTT_MAX_ROOT_CA_CERT_STRLEN
rename const MQTT_MAX_ROOT_CA_CERT_STRLEN to more generic name MQTT_MAX_CERT_STRLEN

Signed-off-by: Martin Dummer <martin.dummer@gmx.net>
2023-04-12 11:58:27 +02:00
Martin Dummer
971ae6d1be
Feature: MQTT add TLS authentication
User asked for TLS client certificate based login from DTU to MQTT
server. This PR implements storage and use of x509 client certificate
and private key.

Signed-off-by: Martin Dummer <martin.dummer@gmx.net>
2023-04-12 08:33:10 +02:00
MalteSchm
f6d0b0997f typo 2023-04-11 18:57:57 +02:00
Bernhard Kaszt
e35254c8f2
New Power meter support: HTTP(S) + JSON (Shelly 3EM, Tasmota, Volkszähler etc.) (#153)
* Implement HTTP(s) + JSON type Power Meter support

---------

Co-authored-by: Bernhard Kaszt <berni@bcserv.eu>
2023-04-03 21:36:20 +02:00
helgeerbe
b3c17c8ee8 Merge branch 'pr/MalteSchm/144' into development 2023-03-27 22:16:53 +02:00
MalteSchm
a4767827b4 merging master 2023-03-26 11:25:08 +02:00
MalteSchm
0b5c47cd2e Adding enable/disable option and pin to control a switch/relais to power the Huawei PSU 2023-03-26 11:00:37 +02:00
Adminius
05a5b2367b PowerMeter Class + SDM PowerMeter support 2023-03-21 23:46:54 +01:00
helgeerbe
06370baa0e Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-03-18 22:42:05 +01:00
helgeerbe
46ce6ad50f Implement battery drain strategies:
- empty when full
- empty at night
2023-03-16 17:48:22 +01:00
helgeerbe
04c7e4fa01 fix cast error with unsigned int
which results in wrong power limit settings if values become < 0 due
 to power export to the grid.
2023-03-16 12:17:14 +01:00
Thomas Basler
2e33f5cd51 Display: Implement rotation setting and removed icons 2023-03-15 20:20:14 +01:00
helgeerbe
4feaa1db98 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-02-27 20:11:06 +01:00
Thomas Basler
f36a31723a Fix #636: Allow full SSID length of 32 characters 2023-02-27 14:32:55 +01:00
helgeerbe
28b24d01ad implement UI for target power consumption 2023-02-24 16:13:32 +01:00
helgeerbe
56151b0d12 make inverter and channel selectable 2023-02-23 21:46:59 +01:00
helgeerbe
a2473645a5 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-02-23 12:01:34 +01:00
helgeerbe
f560f25302 initial merge of power_limiter * missing is inverter and channel setting in gui
* due to bug _webApiPrometheus.init is commented out
2023-02-20 15:56:02 +01:00