enabling the HTTP+JSON power meter without enabling at least one value
makes no sense, so value 1 has always been treated as "always enabled".
while doing the power meter refactoring, however, a regression was
introduced that would hide the settings for value 1 in the web UI until
the power meter settings would be saved, which they cannot be due to
missing settings for value 1.
the MQTT power meter can now process the messages published at the
respective topics as JSON and extract a power value using a JSON path
(same as in HTTP+JSON power meter). additionally, selecting a unit for
the power value as well as an option to invert the value's sign was
added as well, similar to the HTTPS+JSON power meter.
all power meter providers now have their own configuration struct
defined. a respective method to serialize and deserialize the provider
config is implemented for each provider.
apply all config values from the webfrontend, then perform one polling
cycle. display values seperately in the result, and show the resulting
value as well.
the extractUrlComponents method did extract username and password
from the URL and encoded it for basic authentication. however, the
respective result string was never used. we only perform basic
authentication if the auth type is "basic" and if username and
password were supplied through the respective inputs.
the parameters to peform an HTTP request by the HTTP(S)+JSON power meter
have been generalized by introducing a new config struct. this is now
used for all values which the HTTP(S)+JSON power meter can retrieve, and
also used by the HTTP+SML power meter implementation. we anticipate that
other feature will use this config as well.
generalizing also allows to share serialization and deserialization
methods in the configuration handler and the web API handler, leading to
de-duplication of code and reduced flash memory usage.
a new web UI component is implemented to manage a set of HTTP request
settings.
this setting was not used. the baud rate for the SDM is set to 9600 in
the source code. until the baud rate being customizable is actually
required by somebody, we remove the setting altogether.
we used this library solely to interpret the answer of an HTTP web
server as JSON and find a particular value using a path expression in
the HTTP power meter implementation.
since we ran out of flash memory on non-S3 ESP32, we need to cut some
corners. removing FirebaseJson is the last low-hanging fruit that we
currently know of. we can get rid of it by using ArduinoJson (which is
already integral part of the firmware) and implementing a custom logic
to extract a value based on a path expression.
other than the FirebaseJson path "finder", the new implementation
only knows how to access sub-keys delimited by a forward slash. in
particular, accessing array members is not supported any more. I am
hoping that this is simply not an issue. if so, we will have users
complaining and we can add this functionality in a later release.
the upstream project introduced a new Vue component "FormFooter", which
is used to end an input form, namely all settings forms. we should not
only use this component as well, but the save button on our forms
actually broke since the text dtuadmin.Save is replaced by base.Save.
also replace the use of dtuadmin.Seconds with base.Seconds, such that an
upstream change to dtuadmin.Seconds will not break the battery admin an
AC charger views.
* DPL: implement verbose logging switch
* MQTT: implement verbose logging switch
* power meter: implement verbose logging switch
* Hoymiles lib: implement verbose logging switch
* cpp linting: "final" makes "virtual" and "override" redundant
... however, using only "final" is not as verbose.
* add support for energy & power readings on SML based power meters, taking OBIS 16.7.1 for power (using mod. SML Parser lib. by olliiiver)
* switched SML read to use software serial
* made total power meter response controled by meter source to obtain either the sum of phase powers or explicit total power provided by meter
* made mqtt subscriptions to power meter topics meter source dependend
* simplified SML read loop and OBIS handler registration, + minor refactoring
* minor cleanup/style changes and optim. PowerMeter
* fixed build, add SOURCE_SML == 4
* removed optional usage of HW serial for SML power meter
* switched to usage of _powerMeter1Power for SML power reading to allign better with existing code
---------
Co-authored-by: helgeerbe <helge@erbehome.de>