it is important to separate the capabilities of each power meter
provider into their own class/source file, as the providers work
fundamentally different and their implementations must not be
intermangled, which made maintenance and improvements a nightmare
in the past.
makes the value match its description. since most values in the top part
of the live view are related to the AC side of the system, it makes
sense to use the correct value rather than to change the description.
this method calls the overflowed() method on the respective
DynamicJsonDocument and prints a respective message if not all
data could be added to the DynamicJsonDocument.
on the "main" live data websocket this can happen if no
OnBattery-specific data is available to sent but the empty
JSON document is still sent, which trips the web application.
publishing null in the battery live data websocket also trips the web
application, which rightfully assumes a valid object if data is received
through the websocket.
the allocated memory to create the JSON with onBattery-specific totals
for the live view was too little to contain all values, which are sent
regularly.
the update frequency of Victron MPPT charger data, the battery Soc, the
huawei charger power, and the power meter differ from one another, and
differ in particular from the inverter update frequency.
the OnBattery-specific data is now handled in a new method, outside the
upstream code, which merely call the new function(s). the new function
will update the websocket independently from inverter updates. also, it
adds the respective data if it actually changed since it was last
updated through the websocket.
for the webapp to be able to recover in case of errors, all values are
also written to the websocket with a fixed interval of 10 seconds.
To reduce the heap usage it is necessary to send the inverters one by one instead of a huge response. A simple call to `/api/livedata/status` returns just some very general information. If detailed inverter information are required the inverter serial number has to appended `?inv=<serial number>`.
The websocket also returns only one inverter at a time. It as to be assembled at client side.
* Optimize Sun data calculation
* Remove not required enum
* Split config struct into different sub structs
* Feature: Allow configuration of LWT QoS
* Made resetreason methods static
* Feature: Implement offset cache for "YieldDay"
Thanks to @broth-itk for the idea!
Fix: #1258#1397
* Add Esp32-Stick-PoE-A
* remove broken LilyGO_T_ETH_POE config, use device profile instead
* Feature: High resolution Icon and PWA (Progressive Web App) functionality
Fix: #1289
* webapp: Update dependencies
* Initialize TaskScheduler
* Migrate SunPosition to TaskScheduler
* Migrate Datastore to TaskScheduler
* Migrate MqttHandleInverterTotal to TaskSchedule
* Migrate MqttHandleHass to TaskScheduler
* Migrate MqttHandleDtu to TaskScheduler
* Migrate MqttHandleInverter to TaskScheduler
* Migrate LedSingle to TaskScheduler
* Migrate NetworkSettings to TaskScheduler
* Migrate InverterSettings to TaskScheduler
* Migrate MessageOutput to TaskScheduler
* Migrate Display_Graphic to TaskScheduler
* Migrate WebApi to TaskScheduler
* Split InverterSettings into multiple tasks
* Calculate SunPosition only every 5 seconds
* Split LedSingle into multiple tasks
* Upgrade espMqttClient from 1.4.5 to 1.5.0
* Doc: Correct amount of MPP-Tracker
* Added HMT-1600-4T and HMT-1800-4T to DevInfoParser
Fix#1524
* Adjusted inverter names for HMS-1600/1800/2000-4T
* Add channel count to description of detected inverter type (DevInfoParser)
* Adjust device web api endpoint for dynamic led count
* Feature: Added ability to change the brightness of the LEDs
Based on the idea of @moritzlerch with several modifications like pwmTable and structure
* webapp: Update dependencies
* Update olikraus/U8g2 from 2.35.7 to 2.35.8
* Remove not required onWebsocketEvent
* Remove code nesting
* Introduce several const statements
* Remove not required AsyncEventSource
* Doc: Added byte specification to each command
* Feature: Added basic Grid Profile parser which shows the used profile and version
Other values are still outstanding.
* Optimize AlarmLogParser to save memory
* Add libfrozen to project to create constexpr maps
* Feature: First version of GridProfile Parser which shows all values contained in the profile.
* webapp: Update dependencies
* Apply better variable names
* Remove not required casts
* Add additional compiler flags to prevent errors
* Add const statement to several variables
* Replace NULL by nullptr
* Update bblanchon/ArduinoJson from 6.21.3 to 6.21.4
* Add const keyword to method parameters
* Add const keyword to methods
* Use references instead of pointers whenver possible
* Adjust member variable names in MqttSettings
* Adjust member variable names in NetworkSettings
* webapp: Update timezone database to latest version
* webapp: Beautify and unify form footers
* Feature: Allow setting of an inverter limit of 0% and 0W
Thanks to @madmartin in #1270
* Feature: Allow links in device profiles
These links will be shown on the hardware settings page.
* Doc: Added hint regarding HMS-xxxx-xT-NA inverters
* Feature: Added DeviceProfile for CASmo-DTU
Based on #1565
* Upgrade actions/upload-artifact from v3 to v4
* Upgrade actions/download-artifact from v3 to v4
* webapp: add app.js.gz
* Gridprofileparser: Added latest known values
Thanks to @stefan123t and @noone2k
* webapp: Fix lint errors
* Feature: Add DTU to Home Assistant Auto Discovery
This is based on PR 1365 from @CFenner with several fixes and optimizations
* Fix: Remove debug output as it floods the console
* Fix: Gridprofileparser: Add additional error handling if profile is unknown
* webapp: add app.js.gz
* Fix: Offset cache for "YieldDay" did not work correctly
* webapp: update dependencies
* webapp: add app.js.gz
* Fix: yarn.lock was outdated
* Fix: yarn build error
* Fix: Reset Yield day correction in combination with Zero Yield Day on Midnight lead to wrong values.
* Fix: Allow negative values in GridProfileParser
* Correct variable name
* Fix#1579: Static IP in Ethernet mode did not work correctly
* Feature: Added diagram to display
This is based on the idea of @Henrik-Ingenieur and was discussed in #1504
* webapp: update dependencies
* webapp: add app.js.gz
---------
Co-authored-by: Thomas Basler <thomas@familie-basler.net>
Co-authored-by: Pierre Kancir <pierre.kancir.emn@gmail.com>
* VE.Direct: return non-nullptr as a fallback
the changed return statement was supposed to return a shared_ptr to a
new and valid MPPT data struct as a fallback. however, it did return a
new shared_ptr that was initialized to nullptr.
* VE.Direct: make liveview total use total MPPT values
this change makes the call to VictronMppt.getData() obsolete, which in
turn will therefore not cause an error message on the console if
VE.Direct (MPPT) is not enabled. this change also takes care that once
multiple VE.Direct MPPT charge controllers are supported, the sums of
the respective total values are used in the web app totals.
* introduce VictronMpptClass
this solves a design issue where the loop() method of a static instance
of VeDirectMpptController, which is part of library code, is called as
part of the main loop() implementation. that is a problem because the
call to this loop() must be handled differently from all other calls:
the lib does not know whether or not the feature is enabled at all.
also, the instance would not be initialized when enabling the feature
during normal operation. that would even lead to a nullptr exception
since the pointer to the serial implementation is still uninitialized.
this new intermediate class is implemented with the support for multiple
Victron charge controllers in mind. adding support for more charge
controllers should be more viable than ever.
fixes#481.
related to #397#129.
* VE.Direct: move get.*AsString methods to respective structs
those structs, which hold the data to be translated into strings, know
best how to translate them. this change also simplifies access to those
translation, as no parameter must be handed to the respective methods:
they now act upon the data of the instance they are called for. adds
constness to those methods.
* VE.Direct: simplify and clean up get.*AsString methods
use a map, which is much easier to maintain and which reads much easier.
move the strings to flash memory to save RAM.
* DPL: use VictronMpptClass::getPowerOutputWatts method
remove redundant calculation of output power from DPL. consider
separation of concern: VictronMpptClass will provide the total solar
output power. the DPL shall not concern itself about how that value is
calculated and it certainly should be unaware about how many MPPT charge
controllers there actually are.
* VE.Direct: avoid shadowing struct member "P"
P was part of the base struct for both MPPT and SmartShunt controller.
however, P was also part of the SmartShunt controller data struct,
shadowing the member in the base struct.
since P has slightly different meaning in MPPT versus SmartShunt, and
since P is calculated for MPPT controllers but read from SmartShunts, P
now lives in both derived structs, but not in the base struct.
* VE.Direct: isDataValid(): avoid copying data structs
pass a const reference to the base class implementation of isDataValid()
rather than a copy of the whole struct.
* VE.Direct: unify logging of text events
* VE.Direct: stop processing text event if handled by base
in case the base class processed a text event, do not try to match it
against values that are only valid in the derived class -- none will
match.
* VE.Direct MPPT: manage data in a shared_ptr
instead of handing out a reference to a struct which is part of a class
instance that may disappear, e.g., on a config change, we now manage the
lifetime of said data structure using a shared_ptr and hand out copies
of that shared_ptr. this makes sure that users have a valid copy of the
data as long as they hold the shared_ptr.
* VE.Direct MPPT: implement getDataAgeMillis()
this works even if millis() wraps around.
* VE.Direct: process frame end event only for valid frames
save a parameters, save a level of indention, save a function call for
invalid frames.
* Move Mppt logic to subclass
* Added Definitions for Shunts and restructering
* First integration of SmartShunt data into Web Interface
* Code cleanup
* VE.Direct: whitespace cleanup
* VE.Direct: manage HardwareSerial in unique_ptr
* VE.Direct: _efficiency is only needed by MPPT
* VE.Direct: keep as many members private as possible
* VE.Direct: use int8_t for pins (as before)
* VictronSmartShunt: _verboseLogging is not used
* VE.Direct: OR (off reason) is MPPT specific
it also applies to Phoenix inverters and Smart BuckBoost, but since
there is no support for those, the code is moved to the MPPT controller.
* Added Shunt alarms to liveview
Changed from double to int for several readings
* Update build.yml to allow manual builds
---------
Co-authored-by: Philipp Sandhaus <philipp.sandhaus@cewe.de>
Co-authored-by: Bernhard Kirchen <schlimmchen@posteo.net>
Webinterface change to set full solar passthrough values
Adding webapi and config changes to enable full solar passthrough over certain battery Soc
inital version of full solar passthrough in power limiter
Passthrough mode can be enabled via MQTT
translations
re-enable comment
remove unused variable