Commit Graph

410 Commits

Author SHA1 Message Date
Andreas Böhm
df53f34b51
Feature: SPIPortManager allows simultaneous use of CMT2300 and Huawei charger
* backport SPIPortManager from @skippermeister
* adapt to support ESP32 and ESP32-S3 and ESP32-C3
* use logic to work with SPI numbering as in the official
  documentation: start with SPI0 and go up to SPI3
* increase Huawei CAN controller stack size to 2000
* increase startup delay for USB_CDC enabled builds to be able to
  catch bootlogs over USB
2024-08-19 20:44:59 +02:00
Bernhard Kirchen
77af085ad3 Merge upstream tag 'v24.8.1' into development 2024-08-01 20:28:11 +02:00
Thomas Basler
70dacb5ea6 Merge branch 'pr2168' into dev 2024-08-01 17:53:53 +02:00
Bernhard Kirchen
6ee6eaf0b2
Fix: inverter power limits precision
Hoymiles inverters allow setting relative limits with a precision of 0.1 %.
this changeset allows to utilize this precision.

* preserve accuracy when decoding power limit
* Web API: process floating point limits
* MQTT: process floating point limits
* use appropriate accuracy for limits in web UI
* HASS: step for relative inverter limit is 0.1 %
2024-07-23 21:17:25 +02:00
Thomas Basler
45b7f45734 Merge branch 'pr2099' into dev 2024-07-05 21:17:06 +02:00
Thomas Basler
d09be3a384 Feature: Add support for HMS-800-2T-LV inverters 2024-07-05 21:10:15 +02:00
Florian Mösch
ca4c45fcf2 Update AlarmLogParser.cpp
added a few German translations
2024-06-24 17:22:30 +02:00
Bernhard Kirchen
5e3a53d8d3 Merge upstream tag 'v24.6.10' into development 2024-06-21 16:45:41 +02:00
Thomas Basler
b1a8f04617 Fix: Wrong divider in gridprofile RVHF
Fixes #2021
The result may look wrong for some profiles (e.g. 502 Hz) but it seems to be correct as the Hoymiles parser also outputs 502 Hz. See #1606
2024-06-02 13:56:13 +02:00
Thomas Basler
6e607f7f67 Feature: Add option to clear eventlog at midnight 2024-05-31 00:07:28 +02:00
Thomas Basler
3a4f70dc75 Added parser documentation 2024-05-30 23:27:29 +02:00
Thomas Basler
33bfde34b2 Added some missing names to grid profile parser 2024-05-29 22:48:27 +02:00
Thomas Basler
90711ddd76 Code Refactoring: Use internal inverter instance in handleResponse method 2024-05-16 19:58:20 +02:00
Thomas Basler
6d6d62bb77 Code Refactoring: Use internal inverter instance in gotTimeout method 2024-05-16 19:55:01 +02:00
Thomas Basler
6a7bed0ecf Code Refactoring: Add inverter reference to each command
Instead of just adding the target_address to a command this patch adds a reference to the whole inverter instance
2024-05-16 19:54:09 +02:00
helgeerbe
fdc5054480 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into merge-v24.4.12 2024-04-25 20:59:19 +02:00
Thomas Basler
bf49410f6d Merge branch 'pr1909' into dev 2024-04-12 17:05:51 +02:00
Bernhard Kirchen
153293e1c7 remove remaining usage of F() macro 2024-04-12 15:28:26 +02:00
helgeerbe
ff44267e73 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into merge-v24.3.31 2024-04-03 11:53:03 +02:00
Thomas Basler
718690030e Fix include for TimeoutHelper 2024-04-01 13:52:59 +02:00
Thomas Basler
1888054627 Fix: Re-Request grid profile parameters if received data are invalid / to short
Fixes #1874
2024-03-31 12:42:00 +02:00
Bernhard Kirchen
06f39f8396 Merge remote-tracking branch 'tbnobody/master' into development 2024-03-23 22:58:21 +01:00
Thomas Basler
3125f16d99 Fix: Previously check for HwPartNumber 124097 was implemented wrong
Fix: #1846
2024-03-21 20:00:34 +01:00
helgeerbe
5259fc172a Merge remote-tracking branch 'tbnobody/OpenDTU/master' into v24.3.15 2024-03-20 09:42:35 +01:00
Thomas Basler
77b38dff2b Fix: Updated source comments to also match hex numbers 2024-03-15 20:14:29 +01:00
Thomas Basler
f995287a6e Feature: Add support for HERF inverters 2024-03-06 21:57:18 +01:00
Thomas Basler
b8c1168687 Fix: Exclude hardware part number 124097 from valid part numbers.
This triggers a  re-fetch of the hardware information. Especially 124097 seems to be a wrong read-out.
2024-03-03 16:35:34 +01:00
Thomas Basler
021d9b5f44 Feature: Added description for alarm id 152
Fixes: #1798
2024-03-01 19:31:47 +01:00
Thomas Basler
9b7df71da0 webapp: Fix typo
Fixes #1780
2024-02-25 11:23:49 +01:00
helgeerbe
c72ae561c7 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2024-02-19 16:03:56 +01:00
Thomas Basler
bfc604db88 Added HMS-300 to DevInfoParser
Fix #1758
2024-02-16 18:15:50 +01:00
Thomas Basler
dfe82ff17e Added HMT-2000 to DevInfoParser
Fix #1752
2024-02-15 22:11:50 +01:00
Thomas Basler
c24a4ea41d Added second HMS-450 to DevInfoParser
Fix #1744
2024-02-13 16:42:08 +01:00
Thomas Basler
3cf8fea8e0 Fix: Guru Meditation (StoreProhibited) when saving DTU settings
Fixed #1725
2024-02-06 21:47:06 +01:00
Thomas Basler
e81a280b87 Fix: Calculate the AC current for 3 phase inverters correctly 2024-01-30 22:29:25 +01:00
Thomas Basler
abb37242e8 Rename internal variables and methods 2024-01-30 22:29:25 +01:00
Thomas Basler
1b637f0870 BREAKING CHANGE: Web API Endpoint /api/livedata/status and /api/prometheus/metrics
Yield total and Yield day where moved from the AC section to the INV section
2024-01-30 22:29:25 +01:00
Thomas Basler
e1564780d6 BREAKING CHANGE: Web API Endpoint /api/livedata/status and /api/prometheus/metrics
Power DC was moved from the AC section to the INV section
2024-01-30 22:29:25 +01:00
Thomas Basler
f0b5542c2d BREAKING CHANGE: Web API Endpoint /api/livedata/status and /api/prometheus/metrics
Efficiency was moved from the AC section to the INV section
2024-01-30 22:29:25 +01:00
helgeerbe
ebacc2f25f Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2024-01-25 23:36:32 +01:00
Thomas Basler
e66060e769 Move the conversation from time_t to String into DevInfoParser 2024-01-20 01:09:42 +01:00
Thomas Basler
149444decb Fix: Gridprofile dump contained the whole buffer instead of the actual length
As a result, a lot of zeros where placed at the end of the dump
2024-01-18 21:21:40 +01:00
helgeerbe
63205f88be Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2024-01-16 17:39:45 +01:00
Thomas Basler
9093f9de79 Change default target frequency for US and BR 2024-01-14 17:09:53 +01:00
Thomas Basler
a1f2c93cf6 Added const keywords 2024-01-14 16:37:43 +01:00
Thomas Basler
c20caf8097 Feature: Support HMS/HMT inverters in different countries with different frequency bands
Thanks to @Fribur, @homeautomation2022 and @stefan123t
2024-01-14 16:37:34 +01:00
Thomas Basler
188c4688ab Distinct between Band and Country
This allows different frequencies (Startup/Default etc.) for the same band configuration.
2024-01-14 00:06:35 +01:00
Thomas Basler
6b44694a12 Added frequency and command definitions for the 900 MHz band (North America) 2024-01-13 15:29:17 +01:00
Thomas Basler
16cd1a90d5 Move HOY_BOOT_FREQ from define to function 2024-01-13 14:48:23 +01:00
Thomas Basler
58f0121c11 Create separate definition for the 860MHz band of the CMT2300A
This is required to support different countries in the future. The defines where moved to function to change the values dynamically
2024-01-13 14:48:23 +01:00