Commit Graph

461 Commits

Author SHA1 Message Date
helgeerbe
d4d42167ec Merge branch 'pr/philippsandhaus/510' into development 2023-11-15 12:33:50 +01:00
Bernhard Kirchen
254b95cb0f
Fix: replace links to upstream project where applicable (#514) 2023-10-23 13:24:05 +02:00
Philipp Sandhaus
b159c31258 Display efficiency measuremnt for Huawei AC charger in % in web interface 2023-10-20 22:14:45 +02:00
Bernhard Kirchen
4d4aadf8de
Feature: AC charger: configurable CAN controller frequency (#500) 2023-10-19 16:16:01 +02:00
helgeerbe
b461aff622 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-10-10 09:26:43 +02:00
Thomas Basler
76dfaa7d3b Fix #1405: Add some border around icons when in multi line mode 2023-10-09 17:06:47 +02:00
Philipp Sandhaus
7142921021
Integration of Victron SmartShunt via VE.Direct (#452)
* Move Mppt logic to subclass

* Added Definitions for Shunts and restructering

* First integration of SmartShunt data into Web Interface

* Code cleanup

* VE.Direct: whitespace cleanup

* VE.Direct: manage HardwareSerial in unique_ptr

* VE.Direct: _efficiency is only needed by MPPT

* VE.Direct: keep as many members private as possible

* VE.Direct: use int8_t for pins (as before)

* VictronSmartShunt: _verboseLogging is not used

* VE.Direct: OR (off reason) is MPPT specific

it also applies to Phoenix inverters and Smart BuckBoost, but since
there is no support for those, the code is moved to the MPPT controller.

* Added Shunt alarms to liveview
Changed from double to int for several readings

* Update build.yml to allow manual builds

---------

Co-authored-by: Philipp Sandhaus <philipp.sandhaus@cewe.de>
Co-authored-by: Bernhard Kirchen <schlimmchen@posteo.net>
2023-09-22 17:24:57 +02:00
helgeerbe
b081845b95 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-09-19 12:28:00 +02:00
helgeerbe
f7bd4a40d8 revert Revert "Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development"
merge of v23.9.11 broke the system. As a workaround upgrade espressif32 from 6.3.2 to 6.4.0 is skipped. See #440
2023-09-14 13:45:23 +02:00
Thomas Basler
0533c0bcc8 webapp: Rename Fehlernummer to ID
It's not just errors, its also regular messges
2023-09-13 23:19:43 +02:00
helgeerbe
2eeb5f1d19 Revert "Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development"
This reverts commit eb1c2dbd8c, reversing
changes made to 0cb42a6424.

merge of v23.9.11 broke the system
2023-09-12 20:18:10 +02:00
helgeerbe
eb1c2dbd8c Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-09-12 19:27:32 +02:00
Thomas Basler
9ac6dd6e8d Feature: First very basic support to read the grid profile
The parser is still missing and requires community support to collect data.
2023-09-07 22:08:07 +02:00
Thomas Basler
ec9af886d5 Feature: Added option to set daily yield to zero at midnight 2023-09-05 20:27:52 +02:00
Thomas Basler
c46f85db9c webapp: Use max field to determine whether to show a string or not 2023-09-04 19:54:07 +02:00
Bernhard Kirchen
ba303da742
VE.Direct: Reset state machine on timeout, fix and extend logging (#416)
* VE.Direct: reset state machine on timeout

there will never be a large gap between two bytes of the same frame.
if such a large gap is observed, reset the state machine so it tries
to decode a new frame once more data arrives.

this is helpful in case of corrupted data that prevents the state
machine of transitioning to the final state even though the VE.Direct
data producer is done sending bytes that belong to the same frame.

* VE.Direct: print problems to MessageOutput

this includes the web console in particular, where many users have
access to while the serial console is not attached or monitored.

* VE.Direct: collect serial input into buffer and print

should help debug issues for users.

* VE.Direct: implement and use verbose logging switch
2023-09-04 14:07:48 +02:00
Thomas Basler
986d67a3d0 Fix: Better reconnect handling in Live View if invalid data where received 2023-09-02 12:22:55 +02:00
Thomas Basler
6127fbe940 Feature: Added option to set runtime values to zero when inverter becames unreachable 2023-09-02 12:22:22 +02:00
Thomas Basler
9dec05def8 Fix: Check if valid data was received from websocket before assigning it
Otherwise it can lead to exceptions in inverterData method
2023-09-02 01:43:20 +02:00
Thomas Basler
2c41be106e Feature: Allow setting of the Reachable Threshold per inverter 2023-09-01 19:17:12 +02:00
Thomas Basler
c5f9f460cd Feature: Added config option to change MQTT CleanSession Flag 2023-09-01 18:03:30 +02:00
Thomas Basler
b95236c170 Feature: webapp: Move inverter settings into different tabs 2023-09-01 00:20:56 +02:00
Bernhard Kirchen
f744629b0b
Support for Jikong JK BMS using serial connection (#319) 2023-08-31 16:21:32 +02:00
helgeerbe
ca308d0895 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-08-28 13:12:07 +02:00
Bernhard Kirchen
b7214161b8
live view: remove disabled -OnBattery-specifc views from DOM (#372)
instead of hiding views, we can also avoid adding them to the DOM. this
has a couple of advantages:

* no HTTP request for data is sent and no websocket connection is
  established for disabled features.
* JavaScript that causes errors due to incomplete or incompatible data
  of features that are disabled anyways do not trigger the browser
  debugger.
2023-08-10 13:39:21 +02:00
Stefan Schultheis, OE1SCS
629ede3cbd Update en.json
typo. power safe != power save
2023-08-09 18:21:36 +02:00
Stefan Schultheis, OE1SCS
94f6078c9e Update de.json
bessere Übersetzung
2023-08-09 18:20:36 +02:00
helgeerbe
5a72d74982
fix #362 system Info checks git head, instead of build branch (#374) 2023-08-09 17:45:54 +02:00
helgeerbe
21bbed9b8e Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-08-09 12:37:33 +02:00
Thomas Basler
ac4ddbe23d webapp: Fix lint error 2023-08-08 22:50:30 +02:00
Bernhard Kirchen
2bce8311a7
MQTT verbose logging fixes (#341)
* MQTT verbose logging: fix typo

this typo caused that verbose logging was always disabled for MQTT and
could not be enabled.

* webapp status: show MQTT verbose logging setting
2023-07-31 14:16:35 +02:00
helgeerbe
2440028d38 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-07-24 13:16:15 +02:00
Thomas Basler
1146e15ea6 Move units from description to postfix for AP timeout 2023-07-22 18:30:18 +02:00
Martin Dummer
8bfa7e530c Feature: Admin AccessPoint Timeout now configurable
Make the administrative accesspoint timeout configurable. The default
value is 3 minutes, values from 0-99999 are possible, where 0 means
infinite (no timeout).

Signed-off-by: Martin Dummer <martin.dummer@gmx.net>
2023-07-22 18:14:07 +02:00
Thomas Basler
eaacce7483 Feature: Show error in webapp if pin_mapping.json contains syntax errors 2023-07-22 15:51:16 +02:00
Thomas Basler
972dea297b Fix: Prevent runtime errors in webapp when invalid pin_mapping.json is provided 2023-07-22 15:30:40 +02:00
Bernhard Kirchen
f0def2ae89
Selective verbosity (#318)
* DPL: implement verbose logging switch

* MQTT: implement verbose logging switch

* power meter: implement verbose logging switch

* Hoymiles lib: implement verbose logging switch

* cpp linting: "final" makes "virtual" and "override" redundant

... however, using only "final" is not as verbose.
2023-07-18 09:57:03 +02:00
Martin
0dd1566dc6
Fix: WebApp Live-View: adjust window-title and header (#317)
adjust window-title and header from OpenDTU to OpenDTU-onBattery
Additionally change orientation of battery symbol to vertically centered
(looks nicer)

Signed-off-by: Martin Dummer <martin.dummer@gmx.net>
2023-07-18 09:51:59 +02:00
Bernhard Kirchen
f3297930b5
DPL: account for solar passthrough losses (#307)
* fix another fixable "passtrough" typo

the typo in the config's identifier is not changed to preserve
compatibility while not spending the effort to migrate the setting.

* webapp language: prefer SoC over SOC

* DPL: implement solar passthrough loss factor

in (full) solar passthrough mode, the inverter output power is coupled
to the charge controler output power. the inverter efficiency is already
accounted for. however, the battery might still be slowly discharged for
two reasons: (1) line losses are not accounted for and (2) the inverter
outputs a little bit more than permitted by the power limit.

this is undesirable since the battery is significantly drained if solar
passthrough is active for a longer period of time. also, when using full
solar passthrough and a battery communication interface, the SoC will
slowly degrade to a value below the threshold value for full solar
passthrough. this makes the system switch from charging the battery
(potentially rapidly) to discharging the battery slowly. this switch
might happen in rather fast succession. that's effectively
trickle-charging the battery.

instead, this new factor helps to account for line losses between the
solar charge controller and the inverter, such that the battery is
actually not involved in solar passthrough. the value can be increased
until it is observed that the battery is not discharging when solar
passthrough is active.
2023-07-12 13:20:37 +02:00
MalteSchm
475aab1e9a
floating point input (#302) 2023-07-09 17:09:33 +02:00
helgeerbe
3fb062b5cc fix: typo 2023-07-07 17:08:51 +02:00
helgeerbe
ffa9be0835 fix: #294 Passthrough Spelling 2023-07-07 17:05:44 +02:00
Bernhard Kirchen
e457ab73f9
Fix vedirect polling (#291)
* VE.Direct: remove polling interval

the polling interval was meant to limit the amount of MQTT updates.
however, that is already controlled by the global MQTT publish interval.
the removed interval was instead used to limit polling of the VE.Direct
UART for incoming data.

the Victron device sends data unsolicited. the VeDirectFrameHandler does
not implement any polling mechanism. no data is ever sent to the Victron
device.

what the removed polling interval did was cause a buffer overrun of the
HardwareSerial class, since the incoming data was not processed in time.
so every five seconds, we read a whole valid VE.Direct frame, plus some
old data, which was not a whole frame, leading to VE.Direct error
messages to pop up.

with the polling interval removed, no framing errors are reported, and
instead we gain new data from the charge controller approximately ever
two seconds -- for free.

* VE.Direct: change texts to correct VE.Direct capital letters

* VE.Direct: improve "UpdatesOnly" switch labels

especially since the publish interval setting is gone, the label makes
it hard to comprehend what the switch does. update the texts to better
explain what the switch is used for.

use the same text on the VE.Direct info view.

* VE.Direct: use StatusBadge on info view

there were custom badges to indicate the VE.Direct settings. replace
those by the common StatusBadge to make then look the same as the other
badged on the info views.
2023-07-04 12:04:38 +02:00
helgeerbe
006f63ed02 feature: add digest auth on power meter
Power Meter -> HTTP(S) + Jason configuration allows now basic and digest authentication (all Shelly Gen2 devices)
2023-07-04 11:54:46 +02:00
helgeerbe
9a4eb75160 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-07-02 14:32:12 +02:00
MalteSchm
e279ce08c4 Dynamic power control and more power control modes on the Huawei PSU 2023-07-01 12:37:55 +02:00
jdloic
3df65b3d37 Ajout de traductions en Français 2023-06-26 18:31:54 +02:00
helgeerbe
6ed3ce7417 Fix: #274
Iverter is behind power meter - switch does not work
2023-06-26 12:27:26 +02:00
Bernhard Kirchen
07bb0b03f7
DPL hysteresis fix and refactor of setNewPowerLimit() (#264) 2023-06-26 11:52:33 +02:00
helgeerbe
7d73ae3c20 Fix: linting error 2023-06-22 21:55:58 +02:00