Commit Graph

310 Commits

Author SHA1 Message Date
Bernhard Kirchen
1dd64a57fd remove FirebaseJson lib from firmware (save 17.5k of flash)
we used this library solely to interpret the answer of an HTTP web
server as JSON and find a particular value using a path expression in
the HTTP power meter implementation.

since we ran out of flash memory on non-S3 ESP32, we need to cut some
corners. removing FirebaseJson is the last low-hanging fruit that we
currently know of. we can get rid of it by using ArduinoJson (which is
already integral part of the firmware) and implementing a custom logic
to extract a value based on a path expression.

other than the FirebaseJson path "finder", the new implementation
only knows how to access sub-keys delimited by a forward slash. in
particular, accessing array members is not supported any more. I am
hoping that this is simply not an issue. if so, we will have users
complaining and we can add this functionality in a later release.
2024-05-06 11:04:24 +02:00
Bernhard Kirchen
18dab3cf1c Merge upstream tag 'v24.4.24' into development 2024-05-02 20:49:41 +02:00
Bernhard Kirchen
4cf596eb5a
Merge pull request #923 from helgeerbe/merge-v24.4.12
merge upstream tag v24.4.12, resolve conflicts (helgeerbe), fix eslint errors (schlimmchen) and adopt new web api method to save code duplication (schlimmchen).
2024-04-29 21:17:14 +02:00
Bernhard Kirchen
d3b306e2fc appease eslint 2024-04-29 20:31:50 +02:00
helgeerbe
fdc5054480 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into merge-v24.4.12 2024-04-25 20:59:19 +02:00
Thomas Basler
29403013f5 Fix: Device Manager shows 404 if no pin_mapping.json was available 2024-04-24 22:28:59 +02:00
MalteSchm
f0df583c13
Feature: support for Huawei target power consumption 2024-04-24 20:26:56 +02:00
Bernhard Kirchen
abe01ae36f Feature: HTTP power meter: support changing sign 2024-04-18 12:10:29 +02:00
Bernhard Kirchen
ede1abb5e6 Feature: HTTP power meter: support mW/kW as units 2024-04-18 12:10:29 +02:00
Bernhard Kirchen
52d7ac9581 Feature: DPL: support setups without power meter
without a power meter configured, the DPL now sets the base load as the
inverter limit if the battery charge allows it. it also takes
solar-passthrough into account, i.e., if the battery is in a charge
cycle but the solar output (Victron MPPT) is significant, the solar
power will be used up until the base load. if the battery reaches the
full solar passthrough threshold, the DPL will match the inverter limit
to the MPPT solar output.
2024-04-15 23:02:58 +02:00
Bernhard Kirchen
7e307114e5 Feature: DPL: introduce base load setting
on power meter issues (usually a timeout), keep the inverter enabled and
make it produce the configured base load limit if the battery can be
discharged. that should be okay since the base load config value is
expected to be small and a little less than the actual household base
load, i.e., if this amount of power is produced, the household will
consume it in any case and no energy is fed into the grid.
2024-04-15 23:02:58 +02:00
Thomas Basler
de156ef10a webapp: Fix lint errors 2024-04-12 20:34:30 +02:00
Bernhard Kirchen
a9c3e05f05 PowerMeter admin: URL examples to the top and hidden if disabled 2024-04-10 20:44:46 +02:00
eu-gh
0ed09aeb4c Feature: Huawei: add SoC stop threshold and verbose logging switch 2024-04-07 17:16:50 +02:00
Thomas Basler
980e847ccb Feature: Check for out of memory situations when sending json responses
Also shows a nice message in the frontend if an internal error occours
2024-04-05 19:14:56 +02:00
helgeerbe
ff44267e73 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into merge-v24.3.31 2024-04-03 11:53:03 +02:00
MalteSchm
8abf614047 Feature: BMS initiated emergency charging
This change logically connects the AC-Charger with the BMS to add BMS
initiated emergency charging and respecting BMS current limits.
2024-04-02 21:05:00 +02:00
Rene
eff8d52014 better alignment inverter, issue 360 2024-03-25 22:42:22 +01:00
Bernhard Kirchen
054a677575 DPL settings in web app: split metadata from config
users are manipulating the DPL using HTTP POST requests. often they are
requesting the current settings using HTTP GET on the respective route,
then change a particular settings, and send all the data back using HTTP
POST. if they failed to remove the metadata node from the JSON,
OpenDTU-OnBattery would not be able to process the JSON due to its size.
the web app does not submit the metadata.

to avoid problems, the metadata is now split from the configuration
data.
2024-03-23 22:13:50 +01:00
helgeerbe
5259fc172a Merge remote-tracking branch 'tbnobody/OpenDTU/master' into v24.3.15 2024-03-20 09:42:35 +01:00
Snoopy-HSS
f6680bd664 Feature: Support SMA HomeManager 2.0 as PowerMeter 2024-03-17 20:20:29 +01:00
Bernhard Kirchen
13bc943dd5 Feature: Refactor/Simplify DPL settings
this changeset refactors the web application's DPL settings view. the
DPL settings can be complex, and they shall be presented in a way that
allows users to comprehend their meaning. irrelevant settings are now
hidden or displayed dynamically based on the influencing settings.

* group SoC thresholds into their own card

* hide battery SoC thresholds if battery disabled. if the user did not
  even enable the battery interface, battery SoC values will not be used
  for DPL decisions. in that case we completely hide the respective
  settings from the DPL admin view. this reduces the amount of settings
  for new users and especially users who don't even have a battery in
  their setup or have no BMS connected.

* group voltage thresholds and improve label texts

* fix load correction factor unit

* fix header (wording)

* group solar-passthrough settings in new card

* group inverter-related settings

* hide solar passthrough settings if VE.Direct is disabled. closes #662.

* completely disable form if any requirement is not met

* list available inverters by name and type. this makes it much more
  convenient to select the right inverter, especially since the order of
  the inverters in the web UI is decoupled from their position in the
  internal array, which was used to select them previously. care was
  taken that old configs select the same inverter after an update.
  when editing the DPL settings, the selects an inverter from the newly
  created drow-down list, and the respective old inverter is
  pre-selected.

* disable form if no inverter is configured (config alert)

* make inverter input selection dynamic. adjust selection to actual
  amount of channels for selected inverter. skip selection altogether if
  inverter has only one channel, or if it is solar powered.

* web app: wording adjustments

* group meta data into new property and exclude from submission. saves
  memory when evaluating the submitted settings.

* hide irrelevant settings if inverter is solar-powered

* move restart hour setting to inverter card. translate setting which
  disabled automatic restart.

* simplify "drain strategy" setting into an on/off toggle. care was
  taken that existing configs work the same after an upgrade. the
  respective drain strategy is translated into the new setting when
  reading the config. once the config is written, the new setting is
  persisted and the old is not part of the config any more.

* show more configuration hints, depending on actual configuration

* replace inputs by InputElement components where possible
2024-03-17 16:50:57 +01:00
Thomas Basler
437f572c39 Fix: Don't throw exception if git_hash is not set 2024-03-12 22:11:19 +01:00
Thomas Basler
bd8d93bf92 Feature: Allow enabling and disabling of the version check
Fix #1787
2024-03-12 18:35:19 +01:00
Bernhard Kirchen
c6f81806d6 DPL: make "IsInverterSolarPowered" configurable through web app 2024-03-09 15:40:13 +01:00
Thomas Basler
f995287a6e Feature: Add support for HERF inverters 2024-03-06 21:57:18 +01:00
Bernhard Kirchen
50635ee2ce Feature: live view: update with respective frequency
the update frequency of Victron MPPT charger data, the battery Soc, the
huawei charger power, and the power meter differ from one another, and
differ in particular from the inverter update frequency.

the OnBattery-specific data is now handled in a new method, outside the
upstream code, which merely call the new function(s). the new function
will update the websocket independently from inverter updates. also, it
adds the respective data if it actually changed since it was last
updated through the websocket.

for the webapp to be able to recover in case of errors, all values are
also written to the websocket with a fixed interval of 10 seconds.
2024-03-05 11:31:44 +01:00
Bernhard Kirchen
c560d1d90e
fix: copy OnBattery-specific data from live view websocket (#696)
closes #685.
closes #682.
2024-02-29 17:09:18 +01:00
helgeerbe
c72ae561c7 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2024-02-19 16:03:56 +01:00
Bernhard Kirchen
3595725f8a Feature: implement subscription to battery voltage MQTT topic
this extends the MqttBattery implementation by an additional topic which
allows to subscribe to receive battery voltage readings through the MQTT
broker. similar to the battery SoC topic, this allows to import a
critical battery data point for the DPL, in case the user chooses to use
voltage thresholds rather than SoC thresholds to control the DPL. if an
otherwise incompatible BMS is available which publishes the battery pack
voltage through MQTT, this can now be used to feed accurate voltage
readings to the DPL.
2024-02-18 22:17:15 +01:00
Bernhard Kirchen
921302bf73 Feature: DPL: add switch allowing to ignore SoC
unfortunately, the battery SoC values reported by battery BMSs are
unreliable, at least for some users, or at least without regular
(manual) full charge cycles to calibrate the BMS. it offers great
advantages to connect OpenDTU-OnBattery to a BMS (MQTT publishing of
values, Home Assistent integration, etc.), but previously the users
were then forced to configure the DPL by SoC values.

this change allows to configure the DPL such that SoC values are
ignored. instead, the voltage limits are used to make DPL decisions, as
if no SoC was available in the first place.

the SoC related setting are hidden from the DPL settings view if SoC
values are configured to be ignored.

closes #654.
2024-02-18 21:46:42 +01:00
Thomas Basler
b9bf454237 webapp: Add link to documentation in about view 2024-02-10 02:10:06 +01:00
Thomas Basler
c27ecc3620 BREAKING CHANGE: Web API Endpoint /api/livedata/status
To reduce the heap usage it is necessary to send the inverters one by one instead of a huge response. A simple call to `/api/livedata/status` returns just some very general information. If detailed inverter information are required the inverter serial number has to appended `?inv=<serial number>`.
The websocket also returns only one inverter at a time. It as to be assembled at client side.
2024-01-30 22:29:25 +01:00
helgeerbe
ebacc2f25f Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2024-01-25 23:36:32 +01:00
Thomas Basler
d99de94c00 webapp: Fix lint errors 2024-01-21 16:48:47 +01:00
Thomas Basler
8a80289474 Feature: Implement firmware update check is a opt-in to protect your privacy 2024-01-20 22:43:40 +01:00
Thomas Basler
a06d21024c webapp: Move interfaces to seperate file 2024-01-19 21:48:39 +01:00
Thomas Basler
6b31a4d470 webapp: Introduce Modal component
Less duplicated code
2024-01-19 21:36:18 +01:00
Thomas Basler
0584eadcf2 Feature: Automatic page reload after firmware upgrade
This will work after the current upgrade if this code was loaded.
2024-01-19 19:10:49 +01:00
helgeerbe
63205f88be Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2024-01-16 17:39:45 +01:00
Thomas Basler
c20caf8097 Feature: Support HMS/HMT inverters in different countries with different frequency bands
Thanks to @Fribur, @homeautomation2022 and @stefan123t
2024-01-14 16:37:34 +01:00
Thomas Basler
2c92750100 webapp: Remove hard coded min/max frequencies for CMT module 2024-01-13 12:51:20 +01:00
Thomas Basler
ee78698e37 Migrate all frequency calculations to Hz
Previously the code contains calculations  using a mixture  of kHz and Hz.

Thanks to @Fribur
2024-01-13 12:51:20 +01:00
Thomas Basler
f013698471 Feature: Added fullscreen diagram to display 2024-01-13 11:31:12 +01:00
Thomas Basler
637d4f06a3 Feature: Added option to disable the diagram at the display 2024-01-08 14:19:26 +01:00
Thomas Basler
9d8e195ce1 Merge branch 'pr1611' into dev 2024-01-07 01:53:43 +01:00
Bernhard Kirchen
2608080708 Feature: add heap details to system info and prometheus (#595)
this change adds the values of ESP.gteMaxAllocHeap() and
ESP.getMinFreeHead() to the prometheus metrics and the system
information object. the web UI uses these values to diplay the size of
the largest free contiguous block, calculate a rough estimate for the
level of fragmentation, and the maximum usage of heap memory since boot
in absolute and relative amounts.
2024-01-06 20:12:35 +01:00
Thomas Basler
024ee26705 Feature: Added pull to refresh and websocket indicator 2024-01-06 20:03:52 +01:00
Bernhard Kirchen
377406f10c
Feature: add heap details to system info and prometheus (#595)
this change adds the values of ESP.gteMaxAllocHeap() and
ESP.getMinFreeHead() to the prometheus metrics and the system
information object. the web UI uses these values to diplay the size of
the largest free contiguous block, calculate a rough estimate for the
level of fragmentation, and the maximum usage of heap memory since boot
in absolute and relative amounts.
2024-01-05 21:46:31 +01:00
Bernhard Kirchen
e7a005839b
Feature: implement MQTT-driven battery provider (#589)
this battery provider implementation subscribes to a user-configurable
MQTT topic to retrieve the battery SoC value. the value is not
re-published under a different topic. there is no card created in the
web app's live view, since the SoC is already part of the totals at the
top of the live view. that is the only info this battery provider
implements.

closes #293.
relates to #581.
2024-01-04 15:42:10 +01:00