Commit Graph

3 Commits

Author SHA1 Message Date
SW-Nico
b9ad1e3054 VE.Direct: process more values and refactor variable names
* process "IL", "AR" and "MON"
* discard "BMV" and (unsolicited) History Data
* simplify isDataValid()
* veMpptStruct, veStruct: new, verbose variable names, including units,
  and replace floats (save values with original integer precision)
* comment on rollover situation in isDataValid()
2024-04-07 17:13:07 +02:00
Bernhard Kirchen
6b8c93d2e6 polish VE.Direct HEX support
* show charge controller temperature in live view
* send hex requests right after decoding a frame. this seems to have the
  best chance of getting an answer to all requests.
* deem 0xFFFFFFFF value of network total DC power as invalid indicator.
  neither network state, nor network info, nor network mode seem to
  indicate that the charge controller is part of a VE.Smart network. for
  that reason, we revert to always querying the network total DC power
  value, but testing it for max(uin32_t) value, which seems to indicate
  that the charge controller is not part of a VE.Smart network.
* improve (verbose) logging, e.g., use _logId, and print names of
  response codes and known registers, always print error messages,
  add additional tests to prevent overly verbose messages.
* move hex protocol definitions to VeDirectData.h header
  and use enum classes
* define register addresses in enum class
* move values retrieved through hex protocol into main MPPT data struct
* do not send HEX requests if the serial interface cannot send data
* detect whether smart battery sense temperature is available
* web app: make all VE.Direct sub-cards iterable. this makes addind more
  values much simpler and saves a bunch of code in the web app.
* make VeDirectFrameHandler state a type-safe enum class
* unindent MPPT controller loop()
* whitespace cleanup
2024-04-03 16:33:15 +02:00
SW-Nico
aadd7303ac Feature: add support for VE.Direct hex messages 2024-04-03 16:33:15 +02:00