Thomas Basler
c5f9f460cd
Feature: Added config option to change MQTT CleanSession Flag
2023-09-01 18:03:30 +02:00
Thomas Basler
701c490654
Feature: Turn off Display before reboot
...
Thanks for the idea to @StefanOberhumer
This prevents always on Display if the device profile does not contain Display pins anymore after the reboot
2023-08-25 16:57:24 +02:00
Thomas Basler
c91bd42a77
Feature: Turn off LEDs before reboot
...
Thanks for the idea to @StefanOberhumer
This prevents always on LEDs if the device profile does not contain LEDs pins anymore after the reboot
2023-08-25 13:15:55 +02:00
Thomas Basler
77a90095d9
Move different restart calls into one method
2023-08-25 12:58:53 +02:00
Thomas Basler
e2594ac843
Fix: Calculate the json buffer for the inverter list based on INV_MAX_COUNT
2023-08-22 17:05:46 +02:00
Thomas Basler
6429d64062
Prometheus Endpoint: Simplify code by looping over fields instead of duplicated code
2023-08-22 13:00:52 +02:00
Thomas Basler
4bf9083b23
Prometheus Endpoint: Publish only relevant amount of digits
...
Implemented method to return the correctly formatted field value as string
2023-08-22 11:45:14 +02:00
Thomas Basler
9179b672f5
Use lock_guard to simplify code
2023-08-05 01:25:53 +02:00
Thomas Basler
43cba67531
Fix: Virtual console scrambled output when the output came from different contexts
2023-08-03 22:16:29 +02:00
Thomas Basler
0bdee6ec99
Fix: Prevent access to nullptr object when reconnecting to mqtt
...
It could occour when saving the settings via the web ui
2023-08-03 18:46:28 +02:00
Martin Dummer
8bfa7e530c
Feature: Admin AccessPoint Timeout now configurable
...
Make the administrative accesspoint timeout configurable. The default
value is 3 minutes, values from 0-99999 are possible, where 0 means
infinite (no timeout).
Signed-off-by: Martin Dummer <martin.dummer@gmx.net>
2023-07-22 18:14:07 +02:00
Thomas Basler
a68c553d27
Code formatting without functional changes
2023-07-22 18:07:03 +02:00
Thomas Basler
658a42db80
Apply code formatter without functional changes
2023-07-22 18:00:41 +02:00
Thomas Basler
bf4dc56cb8
Fix: Reboot loop if negative display pins and type where provided
...
Fix #1163
2023-07-21 19:02:18 +02:00
Thomas Basler
9dbeec3a31
Fix: Set WiFi setScanMethod and setSortMethod also on first connect
2023-07-20 23:44:09 +02:00
Thomas Basler
b8c75b02a0
Merge branch 'pr1003' into dev
2023-07-10 19:11:54 +02:00
Stephan
1871a9a692
use FSPI for esp32-c3 and revise device profiles
2023-07-10 19:04:13 +02:00
Thomas Basler
fe3d6588bc
Feature: Turn off LED 1 if no inverters are enabled for polling
...
This means that e.g. at night, when polling at night is disabled, LED 1 will be turned off now.
2023-07-10 18:31:04 +02:00
Thomas Basler
93057fc3dc
Feature: Added touch icon for iOS and Android
...
Implements #1060
2023-06-21 22:44:18 +02:00
Thomas Basler
e8fee49dc8
Allow the non-existence of the HOYMILES_PIN_ defines
2023-06-21 19:59:35 +02:00
Thomas Basler
30fbd98274
Fix: Reboot loop occoured when no rf module was configured
2023-06-21 19:56:14 +02:00
Dominic Michel
3562e85b5e
Change metric type back to gauge
2023-06-13 20:59:24 +02:00
Thomas Basler
08f47c2f4c
Fix: Prometheus syntax error with wifi_bssid
...
Fixes #1021
2023-06-11 20:04:23 +02:00
Thomas Basler
88cb59d177
Feature: Publish BSSID via prometheus
2023-06-08 19:57:07 +02:00
Thomas Basler
b3e41c957b
Feature: Publish BSSID via MQTT
2023-06-08 19:56:44 +02:00
Thomas Basler
91d3cd1da2
Feature: Show BSSID in the web interface
2023-06-08 19:56:22 +02:00
Thomas Basler
721f82a17c
Added additional exception handler to also show unknown exceptions in live data api endpoint
2023-06-08 19:39:56 +02:00
Thomas Basler
3b6c529efb
Fix: Do not publish leading blanks in MQTT payload
...
Fixes #1011
2023-06-07 17:58:31 +02:00
Thomas Basler
7f267ff2fb
Fix: Lint Error: Almost always, snprintf is better than strcpy
2023-06-01 23:30:13 +02:00
Thomas Basler
5a37948ca9
Fix: If no sunset/sunrise calculation is possible a wrong value is shown
...
This is catched now and a proper message is shown in the web UI. Also the mode is set to day.
2023-06-01 18:39:50 +02:00
Thomas Basler
24f063dd7b
Fix: Prevent partly calculated total data in web ui and display
...
Leads to zeros where no zeros should be.
2023-05-30 22:10:27 +02:00
Thomas Basler
1c8bd8091b
Feature: Allow reordering of the inverters in the live view
...
Reordering can be done in the inverter settings via drag&drop.
2023-05-29 20:17:07 +02:00
Thomas Basler
e7198073af
Feature: Allow configuration of sunset type
2023-05-24 19:21:44 +02:00
Thomas Basler
752362d2df
Feature: Added localization setting to display
...
Its possible to change the language of the display
2023-05-23 18:25:12 +02:00
Thomas Basler
40820c07f2
Use the new data store in the graphic display class.
...
With this patch, the display turns off if no inverter is reachable anymore. Previously it turned off if the production was zero.
This fixes #933
2023-05-21 22:40:32 +02:00
Thomas Basler
cd98941c5d
Implement global data store to handle all invert total values
...
Use the new values in the LED, MQTT and Web interface.
2023-05-21 22:37:33 +02:00
Thomas Basler
efcbd81927
Feature: Add used PIO environment to the system info page
2023-05-08 21:43:50 +02:00
Thomas Basler
65b728eebb
Fix: No OpenDTU startup of CDC (like Pico or ESP32-S3) devices if no usb host is connected
...
Should also fix #826
2023-05-03 21:16:27 +02:00
Markus Krause
a56d5adb77
fix SPI assignment across generations
2023-04-28 21:26:22 +02:00
Thomas Basler
3504884836
Fix: xSemaphoreTake was useless
...
There was no check of the return value implemented therefore xSemaphoreTake was just executed and not locked
2023-04-28 21:02:10 +02:00
Thomas Basler
5996fb0edf
Fix: MQTT topics ac/yieldday and ac/yieldtotal are swapped
...
Fix #843
2023-04-25 18:43:56 +02:00
Thomas Basler
98da2b64e2
Rename FLD_PRA to FLD_Q
2023-04-24 22:29:59 +02:00
Thomas Basler
26cbc496a7
Feature: Implemented MQTT publishing of total values
...
If one or more inverter is not reachable the flag is_valid changes to zero. Disabled inverters are ignored.
2023-04-24 18:51:30 +02:00
Thomas Basler
04f62e03b8
BREAKING CHANGE: Web API Endpoint /api/eventlog/status no nested serial object
...
It's not required as the eventlog just contains events from requested inverter
2023-04-20 22:41:55 +02:00
Thomas Basler
5d2656550c
Optimize detection if RF module is configured
...
Use PinMapping method instead of dedicated method in Hoymiles lib --> Same result but reduces variables
2023-04-17 23:19:53 +02:00
Thomas Basler
59f43a82a8
BREAKING CHANGE: Web API Endpoint /api/devinfo/status requires GET parameter inv=
...
Only the requested inverter is sent to the client. This reduces the size of the json response --> Less memory.
It should also fix #814 .
2023-04-17 21:48:16 +02:00
Thomas Basler
af3a277e30
Introduced HoymilesRadio property to determine if a configuration attempt was done
2023-04-17 18:59:56 +02:00
Thomas Basler
15156b4b87
Set CMT frequency only if a valid pin config was found
2023-04-15 10:55:48 +02:00
Thomas Basler
c3368450f6
Initialize spiClass only if valid pin config was found
2023-04-15 10:55:48 +02:00
Thomas Basler
50ce7f014d
Expose min and max frequency in HoymilesRadio_CMT
2023-04-15 10:55:48 +02:00