the cards in all information views still used a div.card-body around the
table, which added a margin on all sides of the table. to achieve a
unified look, these cards and tables now look the same as the inverter
channel cards.
we don't need a margin at the bottom of tables in general. not sure why
this is even a thing in bootstrap. this change, in particular, makes the
space between a table and a parent card symmetric on all sides.
* implements UI to configure battery discharge limit
* adds support for discharge limit to MQTT battery provider
* add option to hide `issues` section from battery live view (for MQTT battery)
* show battery voltage, current, and power in live view header (the "totals")
* show battery current and power in extra card
* use soc and current precision in live view
* BatteryStats: do not knowingly publish invalid data: not all battery
providers know all values the base class manages. make sure to
prevent publishing invalid values.
Co-authored-by: Bernhard Kirchen <schlimmchen@posteo.net>
the parameters to peform an HTTP request by the HTTP(S)+JSON power meter
have been generalized by introducing a new config struct. this is now
used for all values which the HTTP(S)+JSON power meter can retrieve, and
also used by the HTTP+SML power meter implementation. we anticipate that
other feature will use this config as well.
generalizing also allows to share serialization and deserialization
methods in the configuration handler and the web API handler, leading to
de-duplication of code and reduced flash memory usage.
a new web UI component is implemented to manage a set of HTTP request
settings.
this only changes line endings. inspect this commit with command `git
show <commit-sha> --ignore-space-at-eol` and it will tell you that the
commit appears to be "empty" (since all changes are whitespace changes
near the end of a line, which are ignored in that git show command).
the files to be changed were found and updated using this command:
find lib src include webapp/src -type f | \
xargs grep --binary-files=without-match --files-with-matches \
$(printf '\r\n') | xargs dos2unix
the following files were restored afterwards, as they are using CRLF
line endings in the upstream as well:
- lib/CMT2300a/cmt2300a_defs.h
- lib/README
- include/README
all total cards at the top of the live view go into the same row.
bootstrap will line-break after every third column/card, as the row
is row-cols-3.
the battery icon to the right of the project name in the header shall
have marging to said project name.
the rows in the live view now use class mt-0 to counteract bootstraps
negative margin for individual rows.
* show charge controller temperature in live view
* send hex requests right after decoding a frame. this seems to have the
best chance of getting an answer to all requests.
* deem 0xFFFFFFFF value of network total DC power as invalid indicator.
neither network state, nor network info, nor network mode seem to
indicate that the charge controller is part of a VE.Smart network. for
that reason, we revert to always querying the network total DC power
value, but testing it for max(uin32_t) value, which seems to indicate
that the charge controller is not part of a VE.Smart network.
* improve (verbose) logging, e.g., use _logId, and print names of
response codes and known registers, always print error messages,
add additional tests to prevent overly verbose messages.
* move hex protocol definitions to VeDirectData.h header
and use enum classes
* define register addresses in enum class
* move values retrieved through hex protocol into main MPPT data struct
* do not send HEX requests if the serial interface cannot send data
* detect whether smart battery sense temperature is available
* web app: make all VE.Direct sub-cards iterable. this makes addind more
values much simpler and saves a bunch of code in the web app.
* make VeDirectFrameHandler state a type-safe enum class
* unindent MPPT controller loop()
* whitespace cleanup
* fix compiler warning in SerialPortManager.cpp: function must not
return void
* clean up and simplify implementation of usesHwPort2()
* make const
* overrides are final
* default implementation returns false
* implement in header, as the implementation is very simple
* rename PortManager to SerialPortManager. as "PortManager" is too
generic, the static instance of the serial port manager is renamed to
"SerialPortManager". the class is therefore renamed to
SerialPortManagerClass, which is in line with other (static) classes
withing OpenDTU(-OnBattery).
* implement separate data ages for MPPT charge controllers
* make sure MPPT data and live data time out
* do not use invalid data of MPPT controlers for calculations
* add :key binding to v-for iterating over MPPT instances
this change adds support for a second Victron MPPT charge controller
using a second serial connection.
* Add device configuration for a second victron mppt
* Update VedirectView for second victron mppt
* Update MqttHandleVedirect for second victron mppt
* Update MqttHandleVedirectHass for second victron mppt
* Handle nonexisting victron controllers with optionals
* Add bool-function to Battery and inherited classes, if uart port 2 is
being used
* Introduced a serial port manager. In order to prevent the battery and
the Victron MPPT to use the same hw serial ports, this class keeps
track of the used ports and their owners.