Commit Graph

40 Commits

Author SHA1 Message Date
helgeerbe
d494810975
merge V23.12.16 (#556)
* Optimize Sun data calculation

* Remove not required enum

* Split config struct into different sub structs

* Feature: Allow configuration of LWT QoS

* Made resetreason methods static

* Feature: Implement offset cache for "YieldDay"

Thanks to @broth-itk for the idea!
Fix: #1258 #1397

* Add Esp32-Stick-PoE-A

* remove broken LilyGO_T_ETH_POE config, use device profile instead

* Feature: High resolution Icon and PWA (Progressive Web App) functionality

Fix: #1289

* webapp: Update dependencies

* Initialize TaskScheduler

* Migrate SunPosition to TaskScheduler

* Migrate Datastore to TaskScheduler

* Migrate MqttHandleInverterTotal to TaskSchedule

* Migrate MqttHandleHass to TaskScheduler

* Migrate MqttHandleDtu to TaskScheduler

* Migrate MqttHandleInverter to TaskScheduler

* Migrate LedSingle to TaskScheduler

* Migrate NetworkSettings to TaskScheduler

* Migrate InverterSettings to TaskScheduler

* Migrate MessageOutput to TaskScheduler

* Migrate Display_Graphic to TaskScheduler

* Migrate WebApi to TaskScheduler

* Split InverterSettings into multiple tasks

* Calculate SunPosition only every 5 seconds

* Split LedSingle into multiple tasks

* Upgrade espMqttClient from 1.4.5 to 1.5.0

* Doc: Correct amount of MPP-Tracker

* Added HMT-1600-4T and HMT-1800-4T to DevInfoParser

Fix #1524

* Adjusted inverter names for HMS-1600/1800/2000-4T

* Add channel count to description of detected inverter type (DevInfoParser)

* Adjust device web api endpoint for dynamic led count

* Feature: Added ability to change the brightness of the LEDs

Based on the idea of @moritzlerch with several modifications like pwmTable and structure

* webapp: Update dependencies

* Update olikraus/U8g2 from 2.35.7 to 2.35.8

* Remove not required onWebsocketEvent

* Remove code nesting

* Introduce several const statements

* Remove not required AsyncEventSource

* Doc: Added byte specification to each command

* Feature: Added basic Grid Profile parser which shows the used profile and version

Other values are still outstanding.

* Optimize AlarmLogParser to save memory

* Add libfrozen to project to create constexpr maps

* Feature: First version of GridProfile Parser which shows all values contained in the profile.

* webapp: Update dependencies

* Apply better variable names

* Remove not required casts

* Add additional compiler flags to prevent errors

* Add const statement to several variables

* Replace NULL by nullptr

* Update bblanchon/ArduinoJson from 6.21.3 to 6.21.4

* Add const keyword to method parameters

* Add const keyword to methods

* Use references instead of pointers whenver possible

* Adjust member variable names in MqttSettings

* Adjust member variable names in NetworkSettings

* webapp: Update timezone database to latest version

* webapp: Beautify and unify form footers

* Feature: Allow setting of an inverter limit of 0% and 0W

Thanks to @madmartin in #1270

* Feature: Allow links in device profiles

These links will be shown on the hardware settings page.

* Doc: Added hint regarding HMS-xxxx-xT-NA inverters

* Feature: Added DeviceProfile for CASmo-DTU

Based on #1565

* Upgrade actions/upload-artifact from v3 to v4

* Upgrade actions/download-artifact from v3 to v4

* webapp: add app.js.gz

* Gridprofileparser: Added latest known values

Thanks to @stefan123t and @noone2k

* webapp: Fix lint errors

* Feature: Add DTU to Home Assistant Auto Discovery

This is based on PR 1365 from @CFenner with several fixes and optimizations

* Fix: Remove debug output as it floods the console

* Fix: Gridprofileparser: Add additional error handling if profile is unknown

* webapp: add app.js.gz

* Fix: Offset cache for "YieldDay" did not work correctly

* webapp: update dependencies

* webapp: add app.js.gz

* Fix: yarn.lock was outdated

* Fix: yarn build error

* Fix: Reset Yield day correction in combination with Zero Yield Day on Midnight lead to wrong values.

* Fix: Allow negative values in GridProfileParser

* Correct variable name

* Fix #1579: Static IP in Ethernet mode did not work correctly

* Feature: Added diagram to display

This is based on the idea of @Henrik-Ingenieur and was discussed in #1504

* webapp: update dependencies

* webapp: add app.js.gz

---------

Co-authored-by: Thomas Basler <thomas@familie-basler.net>
Co-authored-by: Pierre Kancir <pierre.kancir.emn@gmail.com>
2023-12-27 11:49:57 +01:00
Bernhard Kirchen
116da05114
DPL: (re-)send power limits periodically (#483)
avoid staleness in case the same power limit is calculated over and over
again, hence no new power limit value is calculated and hence no power
limit command is sent to the inverter. staleness occurs in this case if
the first power limit command to establish the respective limit was not
received by the inverter. one can easily simulate a situation where the
same power limit is caluclated over and over again: with a battery above
the start threshold, set a very low upper power limit for the inverter
(DPL setting). that value will be used as the limit as long as the power
meter reading is larger than that.

we could also check the limit reported by the inverter. however, that
value is in percent of the inverter's max AC output, and is often not
the same value as we requested as the limit, but slightly off. we then
would have to decide how much deviation is okay, which is unreasonably
complicated.

closes #478.
2023-10-09 09:51:40 +02:00
Bernhard Kirchen
96ee78156d
Fix DPL Mode 2 MQTT Status (#402)
* DPL MQTT handler: modernize

* there is no need to tokenize and check the topic of a received MQTT
  message if we only subscribe to a single topic. all messages will be
  for that topic. avoid testing the topic in the callback alltogether.
* use std::string and std::stoi over allocating and deleting a buffer
  and copying charactes around.
* use a switch statement to process the actual payload.
* break a long line.

* DPL: fix getMode() return value

getMode() returned a bool. probably its return type was not adjusted
when the third mode was introduced. this lead to mode 2 being cast to
true implicitly, which in turn was used to construct a String, such that
"1" was published as the DPL mode when in fact it was 2.

make the mode an enum class to avoid such problems in the future.

inline getMode() and setMode().

fix indention.
2023-08-28 13:20:56 +02:00
Bernhard Kirchen
e6eaa001e7
DPL: use testThreshold() in useFullSolarPassthrough() (#357) 2023-08-06 17:00:27 +02:00
Bernhard Kirchen
aff7924411
Inhibit solar passthrough while battery below stop threshold (#354)
* DPL: improve verbose logging

* shorten DPL log prefix
* canUseDirectSolarPower() was printed two times
* _batteryDischargeEnabled was printed two times
* convert boolean values to human-readable strings
* add units where possible
* split messages into block "before calculating new limit" and "after
  calculating new limit", as the latter cannot rely on _inverter being
  available.
* order messages such that variables whose value is derived from other
  variables are printed later than their dependencies.
* merge output into blocks (one instance near "Printout some stats")
* remove more redundant info (produced in functions outside loop())
* print target grid consumption

* DPL: inhibit solar passthrough while stop threshold reached

* DPL: implement and use isBelowStopThreshold()

we only want to inhibit solar passthrough if the SoC is *below* the stop
threshold, not if it is equal to the stop threshold. otherwise, when
discharging, we would discharge until the battery reached the stop
threshold, then we would also inhibit solar passthrough, until the
battery is charged to the SoC stop threshold plus one percent.
2023-08-04 12:35:37 +02:00
Bernhard Kirchen
f0def2ae89
Selective verbosity (#318)
* DPL: implement verbose logging switch

* MQTT: implement verbose logging switch

* power meter: implement verbose logging switch

* Hoymiles lib: implement verbose logging switch

* cpp linting: "final" makes "virtual" and "override" redundant

... however, using only "final" is not as verbose.
2023-07-18 09:57:03 +02:00
Bernhard Kirchen
cbc99d715f
DPL: increase backoff while inverter is kept shut down (#310)
if the new calculated power limit is below the minimum power limit
setting, the inverter is shut down. the shutdown() function is called
every time this condition is detected, which is also true if the
inverter is kept shut down for longer. that happens while the battery
is charging in particular (solar passthrough off). there are other
cases.

in such cases we still want to get into the DPL status "stable". to be
able to determine this stable state, we must know if the call to
shutdown did actually initiate a shutdown or if the inverter is already
shut down.

we then can forward this "changed" or "not changed" info up the call
chain, where the loop() will know that the system is actually stable.
2023-07-17 09:40:18 +02:00
Bernhard Kirchen
107182f948
DPL: check more requirements and fix backoff initialization (#290)
* DPL: wait for valid time information

we know that the Hoymiles library refuses to send any message to any
inverter until the system has valid time information. until then we can
do nothing, not even shutdown the inverter.

* DPL: wait for device info to be ready

a calculated power limit will always be limited to the reported
device's max power. that upper limit is only known after the first
DevInfoSimpleCommand succeeded. wait for that information to be
available.

* DPL: fix initial calculcation backoff

if the calculation backoff is initialized to zero, the backoff will be
doubled to zero until a new, different power limit was calculated for
the first time. this lead to the DPL recalculating a power limit
hundreds of times without a backoff after startup.
2023-07-04 12:05:10 +02:00
Bernhard Kirchen
9aeb1583b5 DPL: consider the system stable when reusing the old limit
a new status is needed to communicate that no update was sent to the
inverter because its power limit is still valid. in this case,
calculating a new power limit is delayed by an exponentially increasing
backoff. the maximum backoff time is ~1s, which is still plenty fast.

the backoff is actually necessary for another reason: at least
currently, a lot of debug messages are printed to the console. printing
all that information in every DPL loop() is too much.
2023-06-30 21:00:51 +02:00
Bernhard Kirchen
9bab740c43 DPL: replace _plState enum with a simple boolean switch 2023-06-30 21:00:51 +02:00
Bernhard Kirchen
b2d58af5e8 DPL: separate unconditional solar passthrough mode
the unconditional solar passthrough mode, configured using MQTT, works
differently than the normal mode of operation. it is also independent
from the power meter reading. if this mode is active, a shortcut is
taken to a function that implements the actions for this mode. this is
convenient since we don't have to consider special cases in the code
that handles normal mode of operation.
2023-06-30 21:00:51 +02:00
Bernhard Kirchen
71079fa0cc DPL: work on internal copy of pointer to inverter
the DPL already took care to shut down the inverter if anything fishy
was going on, mainly to make sure that the battery is not drained.
however, some cases were missed:

* if the configuration changed such that another inverter is now
  targeted, the one the DPL controlled previously was not shut down.
* if the configuration changed such that another inverter (different
  serial number) was configured at the same index, the previous one
  was not shut down.

this change corrects these problems by making the DPL keep a copy of the
shared_ptr to the inverter. the shared_ptr is only released once the DPL
shut the respective inverter down.
2023-06-30 20:04:39 +02:00
Bernhard Kirchen
2970e84193 DPL requirement: disabled inverter commands
if the inverter is not configured to be sent commands to, the DPL is
unable to control it, so the loop is aborted.
2023-06-30 20:04:39 +02:00
Bernhard Kirchen
18b1076660 DPL: improve responsiveness
this implementation checks all requirements for a new power limit to be
calculated, one after the other. if any requirement is not met, a
respective status is announced.

status messages are communicated on the (serial) console. these can also
be displayed easily on the web app in the future. the status texts
explain clearly what the DPL is currently doing, which aids
understanding how the DPL works. the status is only announced if it
changes, or after a fixed interval.

as each requirement is checked individually, the code readability is
improved as well. previously, all the respective conditions had to be
checked as well, but the statements were more complex.

the DPL loop is now executed with high frequency, i.e., it does not wait
for a fixed timespan to pass before checking requirements. it always
aborts on the first unmet requirement. this should improve responsiveness,
as the DPL checks all requirements more often.

the DPL now waits for all power commands and power limit updates to
complete. when that is the case, a settling time elapses. after the
settling phase, the DPL waits for a new update from the inverter and
from the power meter. now it can be assumed that the values are in sync.
it then makes sense to calculate a new power limit immediately, which
the DPL then does.
2023-06-30 20:04:39 +02:00
Bernhard Kirchen
0b0bcf1dfb fix typo: getLastRequestedPowe*w*rLimit() 2023-06-30 20:04:39 +02:00
Bernhard Kirchen
fd208cf6bb DPL: remove unused member variables 2023-06-30 20:03:21 +02:00
Bernhard Kirchen
07bb0b03f7
DPL hysteresis fix and refactor of setNewPowerLimit() (#264) 2023-06-26 11:52:33 +02:00
Bernhard Kirchen
016e30ec00
DPL: fix efficiency calculation (#270)
there is no need to assume and hardcode a fixed efficiency for the
Victron solar charger. the charger reports the voltage and current at
its battery terminal, which can be used to calculate the charger's
actual power output.

the fallback to 100% for the efficiency of the Hoymiles inverter, in
case it is not producing power, is too optimistic. this commit proposes
to use 96.7% as the efficiency for that case, which is the peak
efficiency for many (all?) Hoymiles inverters as per datasheet. that
value should be closer to the real efficiency that will be achieved once
the inverter is turned on.
2023-06-22 21:30:33 +02:00
MalteSchm
e0a8da84d7 full solar passthrough 2023-06-09 13:09:58 +02:00
Martin Dummer
c727e21a49
Feature: add daily restart for the inverter
Add a configurable restart option for the inverter to set the "YieldDay"
values to zero.

Signed-off-by: Martin Dummer <martin.dummer@gmx.net>
2023-06-04 09:14:42 +02:00
MalteSchm
065c169b20
Set initial PL state in init() to avoid inverter shutdown on reboot... (#224) 2023-05-08 13:25:02 +02:00
MalteSchm
70060559da
Bring back the sun indicator (#195)
* Adding states to display in UI

* Adding states to display in UI
2023-04-27 19:10:12 +02:00
MalteSchm
6b437b5ea1
Inverter toggle fix (#196)
* updating the interface to calcPowerLimit to include both energy sources

* Fixing definition
2023-04-27 19:09:48 +02:00
MalteSchm
be7a43fbfb Removing un-necessary timestamp, commenting code and cleanups 2023-04-13 09:47:12 +02:00
MalteSchm
ee376827fd merging functionality from PL refactor 2023-04-13 09:47:07 +02:00
MalteSchm
9999fa28e8 refactor state machine
merging
2023-04-13 09:46:35 +02:00
MalteSchm
ee82c8c9b8 adding option to disable power limiter via mqtt
adding option to disable power limiter via mqtt - adding missing file
2023-04-13 09:44:48 +02:00
berni2288
09fb0618b4
Merge branch 'MalteSchm-webinterface_summary_updates' into development 2023-04-05 22:27:17 +02:00
Bernhard Kaszt
8ca664a8fe
Use AC power for limit calculation (= Support directly connected PV panels with Power Limiter) (#154)
* Power limiter: Use the actual AC power for limit calculation

instead of the last set limit.

In order support setups without battery connected (sources that don't exhaust the limit)
2023-04-05 10:30:03 +02:00
MalteSchm
abffc38c11 fixing typos 2023-04-04 21:30:53 +02:00
helgeerbe
5d5124dd5b fix last power meter update time 2023-03-22 14:53:36 +01:00
Adminius
05a5b2367b PowerMeter Class + SDM PowerMeter support 2023-03-21 23:46:54 +01:00
helgeerbe
46ce6ad50f Implement battery drain strategies:
- empty when full
- empty at night
2023-03-16 17:48:22 +01:00
helgeerbe
32a96bbd06 change all watt related vars to
int32_t to avoid cast problems with negativ values.
2023-03-16 12:34:14 +01:00
helgeerbe
9214897245 for watt use uint32_t as std type to
avoid cast problems to uint16_t
2023-03-13 11:38:26 +01:00
helgeerbe
01a2ffaed5 [Request] Show actual power limiter state in live view helgeerbe/OpenDTU-OnBattery#134 2023-03-10 16:29:00 +01:00
helgeerbe
716fc867a1 powerLimiter with state machine 2023-03-07 21:04:19 +01:00
helgeerbe
4a51ae5038 victron charge power is integer 2023-03-01 10:23:37 +01:00
helgeerbe
26a8809121 stop inverter, if exporting power to grid 2023-02-28 13:09:10 +01:00
helgeerbe
f560f25302 initial merge of power_limiter * missing is inverter and channel setting in gui
* due to bug _webApiPrometheus.init is commented out
2023-02-20 15:56:02 +01:00