Fix: Allow higher-resolution SoC in live view header (#1197)
Commit accc70dea0 added the battery SoC to
the live view header. But due to getSoC() returning an int,
the precision was limited.

This changes getSoC() to return float so when a source with higher
precision is available, the respective precision is shown.
2024-09-02 11:08:21 +02:00
Bernhard Kirchen
9ebbc58930 Fix: Pylontech/Pytes CAN driver: user interrupts at level 2
we are running out of level 1 interrupts on ESP32-S3 boards. for that
reason, until this prooves to be another sort of problem, we allocate
the TWAI's interrupt for the battery CAN implementation at level 2.
2024-08-28 20:08:47 +02:00
Bernhard Kirchen
119bd3a41e Fix: Increase Huawei CAN task stack size
the stack size was already increased by Andreas Boehm in df53f34b51 in
the context of #1144 (SPI port manager). this change aligns the stack
size to a power of two and adds comments. the commit also serves to
place this change more prominently as a fix in the changelogs.
2024-08-28 15:13:23 +02:00
Bernhard Kirchen
1cbf18d4a7 Feature: HttpGetter: cache digest challenge
this allows us to add a valid Authorization header to each but the first
GET request, saving us from performing two GET requests every time we
want to perform the GET request. we still need a new client nonce and we
need to increase the nonce counter, so we also need to calculate a whole
new response, as we cannot just reuse the previous Authorization header
(that would be a replay attack).
2024-08-28 13:32:47 +02:00
Bernhard Kirchen
fd3b65f4bd Feature: HttpGetter: support MD5 digest authentication
the MD5 scheme should still be widely deployed, even though it is
deprecated. it is also still the default if not specific algorithm
is requested by the server.
2024-08-28 13:32:47 +02:00
Bernhard Kirchen
63612e9276 Fix: restart TCP connection if HTTP server sends Connection:close
we previously performed a whole new GET request when doing digest
authentication. it seemed beneficial to reuse the TCP connection to
perform the second GET request, which includes the authentication
tokens. however, if the server sends "Connection: close" we must not
requse the TCP connection for another HTTP request.

this broke authentication against Shelly devices (at least those with
original firmware).

now we explicitly set "Connection: keep-alive" in our request, and reuse
the TCP connection only if te server replies with "Connection:
keep-alive" as well.
2024-08-28 13:32:47 +02:00
Bernhard Kirchen
b5785d032e print SMA HomeManager timestamp as unsigned number 2024-08-24 21:26:35 +02:00
Bernhard Kirchen
2127b0b080 Fix: SMA HomeManager PowerMeter must announce new values
the SMA power meter implementation did not announce that it received a
new datum, such that the power meter data age was never reset. this made
the power meter values outdated and hence invalid, even though new
values were received and processed.
2024-08-24 21:12:25 +02:00
Bernhard Kirchen
821bc27562 Fix: VE.Direct data is invalid if no controller has valid data
the original implementation of the isDataValid() method worked by
returning false if any of the charge controllers had invalid data. if no
charge controllers were configured, this function then also needed to
also return false.

the logic was changed in 415c767d such that if at least one charge
controller had valid data, the function would return true. this would
have required to adjust the default return statement as well, but it was
not.

if the user enabled VE.Diret and configured at least one charge
controller in the pin mapping, but this controller never delivered any
data, the function would now errorneously return true, because the
container is not empty.

however, if no controller has valid data, this now means we exit the
loop and then the return value must be false, which is also desired if
the container is empty.
2024-08-24 21:06:44 +02:00
Andreas Böhm
65407dbdd6
fix: update mqtt subscriptions when topic changed (#1156)
* update mqtt subscriptions when topic was changed
* DPL/Huawei: manage MQTT subscriptions in map

---------

Co-authored-by: Bernhard Kirchen <schlimmchen@posteo.net>
2024-08-20 23:44:27 +02:00
Andreas Böhm
e7d454ff0b
Feature: support 'use battery at night' without VE.Direct
previously, we needed VE.Direct enabled to know the
solar charge controller output, which solely decided when
it was "nighttime". since this is now determined by the
wall clock, we can offer this feature to users without a
Victron charge controller connected using VE.Direct.
2024-08-19 20:49:37 +02:00
Andreas Böhm
df53f34b51
Feature: SPIPortManager allows simultaneous use of CMT2300 and Huawei charger
* backport SPIPortManager from @skippermeister
* adapt to support ESP32 and ESP32-S3 and ESP32-C3
* use logic to work with SPI numbering as in the official
  documentation: start with SPI0 and go up to SPI3
* increase Huawei CAN controller stack size to 2000
* increase startup delay for USB_CDC enabled builds to be able to
  catch bootlogs over USB
2024-08-19 20:44:59 +02:00
Bernhard Kirchen
2894d15477 remove obsolete #include 2024-08-16 21:38:16 +02:00
Bernhard Kirchen
5d1d071c8a
Fix: Improve DPL nighttime discharging (#1126)
* fix: DPL: start discharging at night logic error

the switch "always start discharging battery at night" would cause to
stop discharging the battery when there was solar power and the battery
was discharged below the start threshold.

this change introduces a nighttime discharging boolean variable, which
is enabled the instant we decide to start a battery discharge cycle due
to nighttime havin arrived. we reset this variable as soon as it is
daytime (solar power available). in that case, we allow discharging the
battery if the start threshold was reached. this can actually be the
case if the battery is charged with cheap electricity during the night.

removed comments as they merely spell out what the if statement already
expresses quite nicely.

* use SunPosition.isDayPeriod() to check for daytime

---------

Co-authored-by: Andreas Böhm <andreas@boehm.cx>
2024-08-15 20:10:32 +02:00
Andreas Böhm
599c5cea7d
adjustment: reduce precision of charged- and discharged energy for pytes batteries (#1165)
Precision is reduced to match the CAN protocol definition.
2024-08-13 17:51:12 +02:00
Andreas Böhm
df11db1244
fix: add auth check on battery, huawei and powermeter API endpoints (#1155) 2024-08-08 20:58:12 +02:00
Bernhard Kirchen
82b28e3732 Merge upstream tag 'v24.8.5' into development 2024-08-06 21:05:21 +02:00
Thomas Basler
cdaf10a92a Fix: Wifi reconnect issue introduced with #2117 and discussed in #2185 was fixed 2024-08-05 18:31:21 +02:00
Bernhard Kirchen
04513d3f22 webapp: disable OTA firmware dialog for unsupported devices
show a warning instead and cancel uploads with a HTPP 500 response.
2024-08-04 22:38:19 +02:00
Bernhard Kirchen
77af085ad3 Merge upstream tag 'v24.8.1' into development 2024-08-01 20:28:11 +02:00
Thomas Basler
03137e15dd Upgrade ESPAsyncWebServer from 2.10.8 to 3.1.2 2024-08-01 18:11:39 +02:00
Thomas Basler
70dacb5ea6 Merge branch 'pr2168' into dev 2024-08-01 17:53:53 +02:00
vaterlangen
cb5e7e59a5 Feature: add unit for MQTT battery voltage (#1143) 2024-07-31 15:05:41 +02:00
Bernhard Kirchen
1a19f881aa Feature: support JSON payload in MQTT battery provider
this changeset adds support for parsing the MQTT battery provider's SoC
and voltage topics' payloads as JSON to extract a numeric value at a
configurable path.
2024-07-31 15:05:41 +02:00
Andreas Böhm
accc70dea0
feature: show battery voltage, current, and power in live view (#1131)
* show battery voltage, current, and power in live view header (the "totals")
* show battery current and power in extra card
* use soc and current precision in live view
* BatteryStats: do not knowingly publish invalid data: not all battery
  providers know all values the base class manages. make sure to
  prevent publishing invalid values.

Co-authored-by: Bernhard Kirchen <schlimmchen@posteo.net>
2024-07-27 21:35:58 +02:00
Andreas Böhm
e95b70efeb
Feature: expose 'full solar passsthrough active' via MQTT (#1136) 2024-07-26 20:37:40 +02:00
Andreas Böhm
e3f9da75b9
BREAKING CHANGE: allow multiple OpenDTU-OnBattery instances at same HASS
This breaks existing HASS automation, as entity names and MQTT topics change!

* include dtu-unique-id in DPL MQTT HASS topics to allow multiple DTUs to be controlled
* fix filename "src/MqttHandlVedirectHass.cpp"
* refactor: use values from 'MqttHandleHass', add 'via_device' to all HASS devices
* set step size for power limiter voltage values
2024-07-23 21:27:14 +02:00
Bernhard Kirchen
6ee6eaf0b2
Fix: inverter power limits precision
Hoymiles inverters allow setting relative limits with a precision of 0.1 %.
this changeset allows to utilize this precision.

* preserve accuracy when decoding power limit
* Web API: process floating point limits
* MQTT: process floating point limits
* use appropriate accuracy for limits in web UI
* HASS: step for relative inverter limit is 0.1 %
2024-07-23 21:17:25 +02:00
Bernhard Kirchen
86a49a781a fix: use mutex when writing MQTT power meter value
we previously used the mutex to protect writing the target variable.
however, we would only do that for the old usecase, where a plain float
value in Watts was expected as the topic's payload.
2024-07-22 20:07:38 +02:00
Bernhard Kirchen
5e5a5253f4 fix: initialize MQTT power meter values to zero
avoid using uninitialized memory.
2024-07-22 20:07:38 +02:00
Niko
415c767d1d
Fix: Victron MPPT: be happy with at least one that delivers valid data (#1118) 2024-07-21 19:46:06 +02:00
Sven Sowa
5fee069c65
Remove double call to generateOnBatteryJsonResponse() (#1115)
the 2nd call was added in a merge operation in April
2024-07-21 17:59:57 +02:00
Bernhard Kirchen
926a0b992d improve error messages when probing JSON path value type 2024-07-15 17:41:30 +02:00
Bernhard Kirchen
9e7a0bca31 fix: handle numeric values disguised as strings in JSON
closes #1104.
2024-07-15 17:41:30 +02:00
Andreas Böhm
b90da210be
Fix: Improve overscaling for shaded inputs (#1089) 2024-07-11 15:03:12 +02:00
Bernhard Kirchen
d9d0141fde Merge upstream tag 'v24.6.29' into development 2024-07-10 21:45:43 +02:00
Bernhard Kirchen
e358513495
Merge PR #1077 from helgeerbe/powermeter-refactoring
this PowerMeter refactoring tackles many issues and prepares to solve many more.
2024-07-10 21:20:39 +02:00
Andreas Böhm
6a3f90ff95
Feature: add support for Pytes batteries using CAN (#1088)
Co-authored-by: Bernhard Kirchen <schlimmchen@posteo.net>
2024-07-10 21:01:49 +02:00
Bernhard Kirchen
b808e9ab18 HTTP+JSON power meter: value 1 is always enabled
enabling the HTTP+JSON power meter without enabling at least one value
makes no sense, so value 1 has always been treated as "always enabled".
while doing the power meter refactoring, however, a regression was
introduced that would hide the settings for value 1 in the web UI until
the power meter settings would be saved, which they cannot be due to
missing settings for value 1.
2024-07-01 22:07:55 +02:00
jstammi
1eab3ae773 Fix: explicitly disconnect prior connecting to wifi
to prevent from invalid association packets exchange
#618

(cherry picked from commit b6c320d481eb77b4f4e0407237917d2d897bfd9d)
2024-06-30 20:20:05 +02:00
Thomas Basler
4640ddfba0 Better handling of empty MQTT client id
If the configured client id is empty, the default value (auto generated) will be used
2024-06-29 11:05:04 +02:00
Thomas Basler
ba95f99e03 Feature: Allow custom MQTT Client ID 2024-06-29 00:28:21 +02:00
Bernhard Kirchen
6b19b877c6 power meter refactoring: split loop task init from init()
when performing a test request using the web UI, we need to init() the
respective power meter, but we do not want to start the polling task.
hence we move initialization of the polling task to the poll() function.
it will return if the task is setup already, otherwise setup the task.
2024-06-27 22:18:41 +02:00
Bernhard Kirchen
6b09ca056e Feature: SML power meters: reset SML decoder
implement a function which allows to reset the SML decoder. this new
function is used after a datagram ends. for the SML HTTP power meter
this is simple: after all bytes from the request's answer have been
decoded, we reset the decoder. for the SML serial power meter, we
perform the reset after a datagram ended based on timing (no new bytes
have been received for a specific amount of time).
2024-06-27 22:18:41 +02:00
Bernhard Kirchen
ea454972b9 Feature: SML power meter: handle checksum error
cache the values decoded in the SML datagram and only copy them to the
local stash of values if the checksum of the SML datagram matched. also
makes sure that values from incomplete SML datagrams are not used.

moreover, we now only publish values to the MQTT broker that we actually
decoded (successfully) from an SML datagram (we previously published 0.0
as values to topics we never decoded a value for).
2024-06-27 22:18:41 +02:00
Bernhard Kirchen
a1138a2202 Feature: Serial SML power meter: poll asynchronously 2024-06-27 22:18:41 +02:00
Bernhard Kirchen
fb7b710cb7 SML power meter: improve message output
* when printing a message, tell the name of the derived class.
* print total power only when state SML_FINAL reached.
* tell if a checksum verification error occurred.
2024-06-27 22:18:41 +02:00
Bernhard Kirchen
6c06e71fd0 Feature: SDM power meter: switch to software serial
a 9600 baud serial interface does not need a hardware UART. these
changes switch the SDM power meter implementation to use a software
serial instance instead. this is desirable as hardware UARTs are scarce
and users need them for JK BMS and VE.Direct interfaces.
2024-06-27 22:18:41 +02:00
Bernhard Kirchen
a5ba24fdd8 SDM power meter: check stop flag in between transactions
the destructor will block for way too long if we keep holding the
polling mutex while performing a transcation with the SDM power meter.
when reading, we now release the lock. afterwards, i.e., in between
transactions, we check the stop flag so the task terminates in a timely
manner once asked to do so.
2024-06-27 22:18:41 +02:00
Bernhard Kirchen
40423b0e07 SDM power meter: evaluate error code after polling value 2024-06-27 22:18:41 +02:00