Commit Graph

829 Commits

Author SHA1 Message Date
Bernhard Kirchen
95e560bdc7 fix: optimize margins in live view
all total cards at the top of the live view go into the same row.
bootstrap will line-break after every third column/card, as the row
is row-cols-3.

the battery icon to the right of the project name in the header shall
have marging to said project name.

the rows in the live view now use class mt-0 to counteract bootstraps
negative margin for individual rows.
2024-06-17 17:32:26 +02:00
Thomas Basler
417df65b92 webapp: update dependencies 2024-06-10 21:40:55 +02:00
Thomas Basler
8ef28e27b4 webapp: update dependencies 2024-06-08 11:11:31 +02:00
Bernhard Kirchen
c22ae2bf8d Feature: show BMS FW and HW version (JK BMS, SmartShunt) 2024-06-01 11:23:22 +02:00
swingstate
561f4be6d6 Feature: SmartShunt: process midpoint voltage and deviation 2024-05-31 21:08:15 +02:00
Bernhard Kirchen
88314f93c2 Fix: properly format Victron MPPT firmware version 2024-05-31 20:16:29 +02:00
Thomas Basler
6e607f7f67 Feature: Add option to clear eventlog at midnight 2024-05-31 00:07:28 +02:00
eu-gh
90eb25f503
Fix: Huawei PSU: enforce BatterySoC Limit < 100 in UI (#992) 2024-05-30 21:31:46 +02:00
Bernhard Kirchen
6ab1b41f78 fix: project's name is 'OpenDTU-OnBattery' (capital 'O')
there were 47 matches in the repo for "OnBattery", but only 17 for
"onBattery". Also, the repo's name on github uses a capital 'O'.
2024-05-30 13:55:44 +02:00
Thomas Basler
72492c267f webapp: Remove no more required locale 2024-05-30 00:05:14 +02:00
Thomas Basler
ea4e7b77f5 webapp: Remove duplicated code 2024-05-29 21:09:37 +02:00
Thomas Basler
df80953b5e Use correct units in hardware info 2024-05-28 23:38:43 +02:00
Thomas Basler
6ce474053e Feature: Show MCU temperature in system info 2024-05-28 23:24:08 +02:00
Thomas Basler
e211dd5be2 Add proper formatting for flashsize output 2024-05-28 21:37:20 +02:00
Thomas Basler
5761e9facf webapp: Locale update for "screensaver"
Fix #2010
2024-05-28 21:32:46 +02:00
Thomas Basler
24983acf17 Merge branch 'pr2015' into dev 2024-05-28 20:13:22 +02:00
Bernhard Kirchen
bdc9c09db2 Feature: show ESP32 flash memory size in system info 2024-05-27 21:54:35 +02:00
Bernhard Kirchen
4972892d9a Feature: show ESP32 flash memory size in system info 2024-05-27 21:52:49 +02:00
Bernhard Kirchen
edf493bc6d DPL web UI: add hint to setting "inverter behind power meter" 2024-05-09 13:58:48 +02:00
Bernhard Kirchen
ca3d1da740 power meter web UI: add example for array access + translations
this re-adds an example JSON path accessing an array in the JSON.
also use translatable texts in the example section.
2024-05-09 13:58:44 +02:00
Bernhard Kirchen
255e81e6bd Merge upstream tag 'v24.5.6' into development 2024-05-07 22:03:26 +02:00
Stefan Schultheis, OE1SCS
a11cc82782
Typos de.json translation 2024-05-07 13:58:27 +02:00
Thomas Basler
f6e048b064 webapp: update dependencies 2024-05-06 19:40:36 +02:00
Bernhard Kirchen
1dd64a57fd remove FirebaseJson lib from firmware (save 17.5k of flash)
we used this library solely to interpret the answer of an HTTP web
server as JSON and find a particular value using a path expression in
the HTTP power meter implementation.

since we ran out of flash memory on non-S3 ESP32, we need to cut some
corners. removing FirebaseJson is the last low-hanging fruit that we
currently know of. we can get rid of it by using ArduinoJson (which is
already integral part of the firmware) and implementing a custom logic
to extract a value based on a path expression.

other than the FirebaseJson path "finder", the new implementation
only knows how to access sub-keys delimited by a forward slash. in
particular, accessing array members is not supported any more. I am
hoping that this is simply not an issue. if so, we will have users
complaining and we can add this functionality in a later release.
2024-05-06 11:04:24 +02:00
Bernhard Kirchen
18dab3cf1c Merge upstream tag 'v24.4.24' into development 2024-05-02 20:49:41 +02:00
Thomas Basler
69e257dc8e webapp: update dependencies 2024-04-29 22:54:26 +02:00
Bernhard Kirchen
4cf596eb5a
Merge pull request #923 from helgeerbe/merge-v24.4.12
merge upstream tag v24.4.12, resolve conflicts (helgeerbe), fix eslint errors (schlimmchen) and adopt new web api method to save code duplication (schlimmchen).
2024-04-29 21:17:14 +02:00
Bernhard Kirchen
d3b306e2fc appease eslint 2024-04-29 20:31:50 +02:00
helgeerbe
fdc5054480 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into merge-v24.4.12 2024-04-25 20:59:19 +02:00
Thomas Basler
5a93a7e4b9 Updated timezone config 2024-04-24 22:33:37 +02:00
Thomas Basler
5ab4b6d38e webapp: update dependencies 2024-04-24 22:31:13 +02:00
Thomas Basler
29403013f5 Fix: Device Manager shows 404 if no pin_mapping.json was available 2024-04-24 22:28:59 +02:00
MalteSchm
f0df583c13
Feature: support for Huawei target power consumption 2024-04-24 20:26:56 +02:00
Bernhard Kirchen
abe01ae36f Feature: HTTP power meter: support changing sign 2024-04-18 12:10:29 +02:00
Bernhard Kirchen
ede1abb5e6 Feature: HTTP power meter: support mW/kW as units 2024-04-18 12:10:29 +02:00
Bernhard Kirchen
5fcf09d0a0 fix hysteresis hint texts 2024-04-15 23:02:58 +02:00
Bernhard Kirchen
52d7ac9581 Feature: DPL: support setups without power meter
without a power meter configured, the DPL now sets the base load as the
inverter limit if the battery charge allows it. it also takes
solar-passthrough into account, i.e., if the battery is in a charge
cycle but the solar output (Victron MPPT) is significant, the solar
power will be used up until the base load. if the battery reaches the
full solar passthrough threshold, the DPL will match the inverter limit
to the MPPT solar output.
2024-04-15 23:02:58 +02:00
Bernhard Kirchen
7e307114e5 Feature: DPL: introduce base load setting
on power meter issues (usually a timeout), keep the inverter enabled and
make it produce the configured base load limit if the battery can be
discharged. that should be okay since the base load config value is
expected to be small and a little less than the actual household base
load, i.e., if this amount of power is produced, the household will
consume it in any case and no energy is fed into the grid.
2024-04-15 23:02:58 +02:00
Thomas Basler
011f00e5de Fix: If unauthenticaed, the redirect to login page did not work 2024-04-12 20:38:28 +02:00
Thomas Basler
de156ef10a webapp: Fix lint errors 2024-04-12 20:34:30 +02:00
Thomas Basler
b58d08683e webapp: update dependencies 2024-04-12 20:02:18 +02:00
Bernhard Kirchen
a9c3e05f05 PowerMeter admin: URL examples to the top and hidden if disabled 2024-04-10 20:44:46 +02:00
eu-gh
0ed09aeb4c Feature: Huawei: add SoC stop threshold and verbose logging switch 2024-04-07 17:16:50 +02:00
Thomas Basler
980e847ccb Feature: Check for out of memory situations when sending json responses
Also shows a nice message in the frontend if an internal error occours
2024-04-05 19:14:56 +02:00
Bernhard Kirchen
3934906001
Merge pull request #836 from helgeerbe/merge-v24.3.31
Merges v24.3.31 from upstream
2024-04-03 20:08:09 +02:00
Bernhard Kirchen
21cdc69625 Feature: use VE.Direct "network total DC power"
1. makes the DPL use the power generated by all connected charge
   controllers for calculations based on solar passthrough.
2. makes the network total DC power appear as "MPPT Total Power" in the
   live view at the top.
3. shows the network total DC power in the VE.Direct live data card.
2024-04-03 16:33:15 +02:00
Bernhard Kirchen
6b8c93d2e6 polish VE.Direct HEX support
* show charge controller temperature in live view
* send hex requests right after decoding a frame. this seems to have the
  best chance of getting an answer to all requests.
* deem 0xFFFFFFFF value of network total DC power as invalid indicator.
  neither network state, nor network info, nor network mode seem to
  indicate that the charge controller is part of a VE.Smart network. for
  that reason, we revert to always querying the network total DC power
  value, but testing it for max(uin32_t) value, which seems to indicate
  that the charge controller is not part of a VE.Smart network.
* improve (verbose) logging, e.g., use _logId, and print names of
  response codes and known registers, always print error messages,
  add additional tests to prevent overly verbose messages.
* move hex protocol definitions to VeDirectData.h header
  and use enum classes
* define register addresses in enum class
* move values retrieved through hex protocol into main MPPT data struct
* do not send HEX requests if the serial interface cannot send data
* detect whether smart battery sense temperature is available
* web app: make all VE.Direct sub-cards iterable. this makes addind more
  values much simpler and saves a bunch of code in the web app.
* make VeDirectFrameHandler state a type-safe enum class
* unindent MPPT controller loop()
* whitespace cleanup
2024-04-03 16:33:15 +02:00
helgeerbe
ff44267e73 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into merge-v24.3.31 2024-04-03 11:53:03 +02:00
MalteSchm
8abf614047 Feature: BMS initiated emergency charging
This change logically connects the AC-Charger with the BMS to add BMS
initiated emergency charging and respecting BMS current limits.
2024-04-02 21:05:00 +02:00
PhilJaro
da96273085
Fix typo in German locale (#831) 2024-04-02 12:05:45 +02:00
Thomas Basler
f0a8cabc2c webapp: update dependencies 2024-03-31 14:31:57 +02:00
Rene
eff8d52014 better alignment inverter, issue 360 2024-03-25 22:42:22 +01:00
Bernhard Kirchen
06f39f8396 Merge remote-tracking branch 'tbnobody/master' into development 2024-03-23 22:58:21 +01:00
Bernhard Kirchen
054a677575 DPL settings in web app: split metadata from config
users are manipulating the DPL using HTTP POST requests. often they are
requesting the current settings using HTTP GET on the respective route,
then change a particular settings, and send all the data back using HTTP
POST. if they failed to remove the metadata node from the JSON,
OpenDTU-OnBattery would not be able to process the JSON due to its size.
the web app does not submit the metadata.

to avoid problems, the metadata is now split from the configuration
data.
2024-03-23 22:13:50 +01:00
Thomas Basler
bf4d128e49 webapp: update dependencies 2024-03-22 20:39:12 +01:00
Thomas Basler
ed326763b7 webapp: update dependencies 2024-03-21 19:59:13 +01:00
helgeerbe
5259fc172a Merge remote-tracking branch 'tbnobody/OpenDTU/master' into v24.3.15 2024-03-20 09:42:35 +01:00
PhilJaro
4f0385285c add new Victron SmartShunt values to liveView and MQTT (HASS) 2024-03-17 21:00:32 +01:00
Snoopy-HSS
f6680bd664 Feature: Support SMA HomeManager 2.0 as PowerMeter 2024-03-17 20:20:29 +01:00
Bernhard Kirchen
13bc943dd5 Feature: Refactor/Simplify DPL settings
this changeset refactors the web application's DPL settings view. the
DPL settings can be complex, and they shall be presented in a way that
allows users to comprehend their meaning. irrelevant settings are now
hidden or displayed dynamically based on the influencing settings.

* group SoC thresholds into their own card

* hide battery SoC thresholds if battery disabled. if the user did not
  even enable the battery interface, battery SoC values will not be used
  for DPL decisions. in that case we completely hide the respective
  settings from the DPL admin view. this reduces the amount of settings
  for new users and especially users who don't even have a battery in
  their setup or have no BMS connected.

* group voltage thresholds and improve label texts

* fix load correction factor unit

* fix header (wording)

* group solar-passthrough settings in new card

* group inverter-related settings

* hide solar passthrough settings if VE.Direct is disabled. closes #662.

* completely disable form if any requirement is not met

* list available inverters by name and type. this makes it much more
  convenient to select the right inverter, especially since the order of
  the inverters in the web UI is decoupled from their position in the
  internal array, which was used to select them previously. care was
  taken that old configs select the same inverter after an update.
  when editing the DPL settings, the selects an inverter from the newly
  created drow-down list, and the respective old inverter is
  pre-selected.

* disable form if no inverter is configured (config alert)

* make inverter input selection dynamic. adjust selection to actual
  amount of channels for selected inverter. skip selection altogether if
  inverter has only one channel, or if it is solar powered.

* web app: wording adjustments

* group meta data into new property and exclude from submission. saves
  memory when evaluating the submitted settings.

* hide irrelevant settings if inverter is solar-powered

* move restart hour setting to inverter card. translate setting which
  disabled automatic restart.

* simplify "drain strategy" setting into an on/off toggle. care was
  taken that existing configs work the same after an upgrade. the
  respective drain strategy is translated into the new setting when
  reading the config. once the config is written, the new setting is
  persisted and the old is not part of the config any more.

* show more configuration hints, depending on actual configuration

* replace inputs by InputElement components where possible
2024-03-17 16:50:57 +01:00
Bernhard Kirchen
7d6b7252bf polish support for second VE.Direct MPPT charge controller
* fix compiler warning in SerialPortManager.cpp: function must not
  return void

* clean up and simplify implementation of usesHwPort2()
  * make const
  * overrides are final
  * default implementation returns false
  * implement in header, as the implementation is very simple

* rename PortManager to SerialPortManager. as "PortManager" is too
  generic, the static instance of the serial port manager is renamed to
  "SerialPortManager". the class is therefore renamed to
  SerialPortManagerClass, which is in line with other (static) classes
  withing OpenDTU(-OnBattery).

* implement separate data ages for MPPT charge controllers

* make sure MPPT data and live data time out

* do not use invalid data of MPPT controlers for calculations

* add :key binding to v-for iterating over MPPT instances
2024-03-17 16:50:15 +01:00
Arman Vartan
75541be248 Feature: Support for second Victron MPPT charge controller
this change adds support for a second Victron MPPT charge controller
using a second serial connection.

* Add device configuration for a second victron mppt
* Update VedirectView for second victron mppt
* Update MqttHandleVedirect for second victron mppt
* Update MqttHandleVedirectHass for second victron mppt
* Handle nonexisting victron controllers with optionals
* Add bool-function to Battery and inherited classes, if uart port 2 is
  being used
* Introduced a serial port manager. In order to prevent the battery and
  the Victron MPPT to use the same hw serial ports, this class keeps
  track of the used ports and their owners.
2024-03-17 16:50:15 +01:00
Thomas Basler
7c60c37f49 webapp: update dependencies 2024-03-15 20:16:59 +01:00
Thomas Basler
3138e28cdf webapp: Remove not required cast to string 2024-03-15 19:54:29 +01:00
Thomas Basler
a0d0aec677 Fix: Correct detection of Hoymiles serial if it contains hex characters 2024-03-15 19:46:24 +01:00
Bernhard Kirchen
2efa1b35b0 live view: do not access undefined data
if the respective feature is disabled, there is no data. do not try to
access it.
2024-03-15 08:55:21 +01:00
Bernhard Kirchen
cf27bd29d7 adjust (new) about texts to OpenDTU-OnBattery 2024-03-14 16:27:32 +01:00
Thomas Basler
437f572c39 Fix: Don't throw exception if git_hash is not set 2024-03-12 22:11:19 +01:00
Thomas Basler
bd8d93bf92 Feature: Allow enabling and disabling of the version check
Fix #1787
2024-03-12 18:35:19 +01:00
Thomas Basler
9634c93a3c Fix: Show firmware update tooltip only if newer version available
Closes #1796
2024-03-12 17:27:43 +01:00
Thomas Basler
57a997baac webapp: update dependencies 2024-03-12 16:42:29 +01:00
Bernhard Kirchen
c6f81806d6 DPL: make "IsInverterSolarPowered" configurable through web app 2024-03-09 15:40:13 +01:00
Thomas Basler
f995287a6e Feature: Add support for HERF inverters 2024-03-06 21:57:18 +01:00
Bernhard Kirchen
50635ee2ce Feature: live view: update with respective frequency
the update frequency of Victron MPPT charger data, the battery Soc, the
huawei charger power, and the power meter differ from one another, and
differ in particular from the inverter update frequency.

the OnBattery-specific data is now handled in a new method, outside the
upstream code, which merely call the new function(s). the new function
will update the websocket independently from inverter updates. also, it
adds the respective data if it actually changed since it was last
updated through the websocket.

for the webapp to be able to recover in case of errors, all values are
also written to the websocket with a fixed interval of 10 seconds.
2024-03-05 11:31:44 +01:00
Thomas Basler
10cd2e4201 webapp: update dependencies 2024-03-04 21:07:01 +01:00
Thomas Basler
3c2b35016a webapp: update dependencies 2024-03-01 19:36:18 +01:00
Bernhard Kirchen
c560d1d90e
fix: copy OnBattery-specific data from live view websocket (#696)
closes #685.
closes #682.
2024-02-29 17:09:18 +01:00
helgeerbe
c72ae561c7 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2024-02-19 16:03:56 +01:00
Thomas Basler
f80d03210b webapp: update dependencies 2024-02-19 15:47:59 +01:00
Bernhard Kirchen
3595725f8a Feature: implement subscription to battery voltage MQTT topic
this extends the MqttBattery implementation by an additional topic which
allows to subscribe to receive battery voltage readings through the MQTT
broker. similar to the battery SoC topic, this allows to import a
critical battery data point for the DPL, in case the user chooses to use
voltage thresholds rather than SoC thresholds to control the DPL. if an
otherwise incompatible BMS is available which publishes the battery pack
voltage through MQTT, this can now be used to feed accurate voltage
readings to the DPL.
2024-02-18 22:17:15 +01:00
Bernhard Kirchen
921302bf73 Feature: DPL: add switch allowing to ignore SoC
unfortunately, the battery SoC values reported by battery BMSs are
unreliable, at least for some users, or at least without regular
(manual) full charge cycles to calibrate the BMS. it offers great
advantages to connect OpenDTU-OnBattery to a BMS (MQTT publishing of
values, Home Assistent integration, etc.), but previously the users
were then forced to configure the DPL by SoC values.

this change allows to configure the DPL such that SoC values are
ignored. instead, the voltage limits are used to make DPL decisions, as
if no SoC was available in the first place.

the SoC related setting are hidden from the DPL settings view if SoC
values are configured to be ignored.

closes #654.
2024-02-18 21:46:42 +01:00
Thomas Basler
380879e077 webapp: update dependencies 2024-02-16 18:24:14 +01:00
Hannes0009
a1cd1617e4
Update de.json
improved german orthography
2024-02-14 11:06:07 +01:00
Thomas Basler
c97de9b690 webapp: update dependencies 2024-02-12 16:48:54 +01:00
Thomas Basler
b9bf454237 webapp: Add link to documentation in about view 2024-02-10 02:10:06 +01:00
helgeerbe
b794f46ef0 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2024-02-09 20:14:58 +01:00
Thomas Basler
ac91a50ffe webapp: update dependencies 2024-02-07 19:29:09 +01:00
Thomas Basler
8e01a275af Merge branch 'pr1693' into dev 2024-02-02 22:36:18 +01:00
Nikolaj Kappler
86b9625254 fix #1668
use builtin bootstrap css for scrolling
2024-02-02 22:34:58 +01:00
Thomas Basler
7e2064e264 Feature: Added support for boards with 16MB flash and PSRAM 2024-02-02 20:33:42 +01:00
Thomas Basler
c27ecc3620 BREAKING CHANGE: Web API Endpoint /api/livedata/status
To reduce the heap usage it is necessary to send the inverters one by one instead of a huge response. A simple call to `/api/livedata/status` returns just some very general information. If detailed inverter information are required the inverter serial number has to appended `?inv=<serial number>`.
The websocket also returns only one inverter at a time. It as to be assembled at client side.
2024-01-30 22:29:25 +01:00
vaterlangen
97f006d867 fixed typo in OTA text 2024-01-27 15:18:25 +01:00
Thomas Basler
fe9ac6a2fd webapp: update dependencies 2024-01-26 16:56:49 +01:00
helgeerbe
7094bca7db fix: Inverter Labels in InverterTotalInfo 2024-01-26 13:34:03 +01:00
helgeerbe
ebacc2f25f Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2024-01-25 23:36:32 +01:00
Thomas Basler
d99de94c00 webapp: Fix lint errors 2024-01-21 16:48:47 +01:00
Thomas Basler
3f135e8349 webapp: update dependencies 2024-01-21 16:39:22 +01:00
Thomas Basler
4cfb1b1c26 Fix: PullToRefresh does not work anymore
It was using the wrong mainElement
2024-01-21 00:55:05 +01:00
Thomas Basler
8a80289474 Feature: Implement firmware update check is a opt-in to protect your privacy 2024-01-20 22:43:40 +01:00
Thomas Basler
9428eecce4 webapp: Use CardElement in InverterTotalInfo 2024-01-19 22:03:26 +01:00