this allows us to fix the version of yarn, the Node.js package manager,
to a particular version. using corepack is the recommended way to use
yarn these days.
this allows us to fix the version of yarn, the Node.js package manager,
to a particular version. using corepack is the recommended way to use
yarn these days.
* implements UI to configure battery discharge limit
* adds support for discharge limit to MQTT battery provider
* add option to hide `issues` section from battery live view (for MQTT battery)
we must not reset the configuration switch value in this context. this
leads to solar passthrough being disabled once the DPL is disabled. when
re-enabling the DPL, solar passthrough is suddenly off, even though the
user configured it to be on.
the configuration switch can stay on. the DPL will still sanity-check
whether or not solar-passthrough can be used (checks if VE.Direct is
enabled) or it is irrelevant since the DPL is disabled.
official release builds are built from branch master, as the respective
tags point to commits in branch master (only). to check whether or not a
new version is available, we should check branch master for new commits.
checking against HEAD does not work as expected, at least in the
OpenDTU-OnBattery repo, since its default branch is "development", not
"master".
usually, there should be no commits on master in between releases, so we
will now only show "update available" if a new release was made. this is
not foolproof, but should work as long as we keep "master" clean.
for builds from other branches, the comparison is perfomed against the
respective branch. if a user installed a binary built by github actions
based on a development branch, the user will see "update available" if
new commits were added to the development branch since.
for other branches, also pull request builds, the test for updates will
fail as the branch name shown in the system info is not actually a
branch name, e.g., "helgeerbe/OpenDTU-OnBattery/pr1183-202408212043".
previously, we needed VE.Direct enabled to know the
solar charge controller output, which solely decided when
it was "nighttime". since this is now determined by the
wall clock, we can offer this feature to users without a
Victron charge controller connected using VE.Direct.
this changeset adds support for parsing the MQTT battery provider's SoC
and voltage topics' payloads as JSON to extract a numeric value at a
configurable path.
* show battery voltage, current, and power in live view header (the "totals")
* show battery current and power in extra card
* use soc and current precision in live view
* BatteryStats: do not knowingly publish invalid data: not all battery
providers know all values the base class manages. make sure to
prevent publishing invalid values.
Co-authored-by: Bernhard Kirchen <schlimmchen@posteo.net>
Hoymiles inverters allow setting relative limits with a precision of 0.1 %.
this changeset allows to utilize this precision.
* preserve accuracy when decoding power limit
* Web API: process floating point limits
* MQTT: process floating point limits
* use appropriate accuracy for limits in web UI
* HASS: step for relative inverter limit is 0.1 %
enabling the HTTP+JSON power meter without enabling at least one value
makes no sense, so value 1 has always been treated as "always enabled".
while doing the power meter refactoring, however, a regression was
introduced that would hide the settings for value 1 in the web UI until
the power meter settings would be saved, which they cannot be due to
missing settings for value 1.