Commit Graph

304 Commits

Author SHA1 Message Date
Bernhard Kirchen
77af085ad3 Merge upstream tag 'v24.8.1' into development 2024-08-01 20:28:11 +02:00
Andreas Böhm
accc70dea0
feature: show battery voltage, current, and power in live view (#1131)
* show battery voltage, current, and power in live view header (the "totals")
* show battery current and power in extra card
* use soc and current precision in live view
* BatteryStats: do not knowingly publish invalid data: not all battery
  providers know all values the base class manages. make sure to
  prevent publishing invalid values.

Co-authored-by: Bernhard Kirchen <schlimmchen@posteo.net>
2024-07-27 21:35:58 +02:00
Bernhard Kirchen
d9d0141fde Merge upstream tag 'v24.6.29' into development 2024-07-10 21:45:43 +02:00
Bernhard Kirchen
e358513495
Merge PR #1077 from helgeerbe/powermeter-refactoring
this PowerMeter refactoring tackles many issues and prepares to solve many more.
2024-07-10 21:20:39 +02:00
Andreas Böhm
6a3f90ff95
Feature: add support for Pytes batteries using CAN (#1088)
Co-authored-by: Bernhard Kirchen <schlimmchen@posteo.net>
2024-07-10 21:01:49 +02:00
Thomas Basler
342642ec01 webapp: Apply auto formatter 2024-07-05 21:57:53 +02:00
Thomas Basler
e4bbf55ea5 webapp: Check if temperature is set
It seems that some ESPs don't have a temperature sensor anymore
2024-06-29 00:08:57 +02:00
Bernhard Kirchen
9911dec279 HTTP request config component: do not mutate prop
use an event-driven mutation scheme, i.e., adapt the common v-model
approach to bind data to the child component.
2024-06-27 22:18:41 +02:00
Bernhard Kirchen
9520d8d394 powermeter refactor: polish web UI 2024-06-27 22:18:41 +02:00
Bernhard Kirchen
297b149f84 powermeter refactor: generalize HTTP request config
the parameters to peform an HTTP request by the HTTP(S)+JSON power meter
have been generalized by introducing a new config struct. this is now
used for all values which the HTTP(S)+JSON power meter can retrieve, and
also used by the HTTP+SML power meter implementation. we anticipate that
other feature will use this config as well.

generalizing also allows to share serialization and deserialization
methods in the configuration handler and the web API handler, leading to
de-duplication of code and reduced flash memory usage.

a new web UI component is implemented to manage a set of HTTP request
settings.
2024-06-26 21:25:08 +02:00
Bernhard Kirchen
83c59d7811 convert files with CRLF endings to LF endings
this only changes line endings. inspect this commit with command `git
show <commit-sha> --ignore-space-at-eol` and it will tell you that the
commit appears to be "empty" (since all changes are whitespace changes
near the end of a line, which are ignored in that git show command).

the files to be changed were found and updated using this command:
find lib src include webapp/src -type f | \
    xargs grep --binary-files=without-match --files-with-matches \
    $(printf '\r\n') | xargs dos2unix

the following files were restored afterwards, as they are using CRLF
line endings in the upstream as well:
 - lib/CMT2300a/cmt2300a_defs.h
 - lib/README
 - include/README
2024-06-24 21:57:12 +02:00
Bernhard Kirchen
5e3a53d8d3 Merge upstream tag 'v24.6.10' into development 2024-06-21 16:45:41 +02:00
Bernhard Kirchen
95e560bdc7 fix: optimize margins in live view
all total cards at the top of the live view go into the same row.
bootstrap will line-break after every third column/card, as the row
is row-cols-3.

the battery icon to the right of the project name in the header shall
have marging to said project name.

the rows in the live view now use class mt-0 to counteract bootstraps
negative margin for individual rows.
2024-06-17 17:32:26 +02:00
Bernhard Kirchen
c22ae2bf8d Feature: show BMS FW and HW version (JK BMS, SmartShunt) 2024-06-01 11:23:22 +02:00
Bernhard Kirchen
88314f93c2 Fix: properly format Victron MPPT firmware version 2024-05-31 20:16:29 +02:00
Bernhard Kirchen
6ab1b41f78 fix: project's name is 'OpenDTU-OnBattery' (capital 'O')
there were 47 matches in the repo for "OnBattery", but only 17 for
"onBattery". Also, the repo's name on github uses a capital 'O'.
2024-05-30 13:55:44 +02:00
Thomas Basler
df80953b5e Use correct units in hardware info 2024-05-28 23:38:43 +02:00
Thomas Basler
6ce474053e Feature: Show MCU temperature in system info 2024-05-28 23:24:08 +02:00
Thomas Basler
e211dd5be2 Add proper formatting for flashsize output 2024-05-28 21:37:20 +02:00
Bernhard Kirchen
bdc9c09db2 Feature: show ESP32 flash memory size in system info 2024-05-27 21:54:35 +02:00
Bernhard Kirchen
4972892d9a Feature: show ESP32 flash memory size in system info 2024-05-27 21:52:49 +02:00
Bernhard Kirchen
d3b306e2fc appease eslint 2024-04-29 20:31:50 +02:00
helgeerbe
fdc5054480 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into merge-v24.4.12 2024-04-25 20:59:19 +02:00
Thomas Basler
de156ef10a webapp: Fix lint errors 2024-04-12 20:34:30 +02:00
Bernhard Kirchen
6b8c93d2e6 polish VE.Direct HEX support
* show charge controller temperature in live view
* send hex requests right after decoding a frame. this seems to have the
  best chance of getting an answer to all requests.
* deem 0xFFFFFFFF value of network total DC power as invalid indicator.
  neither network state, nor network info, nor network mode seem to
  indicate that the charge controller is part of a VE.Smart network. for
  that reason, we revert to always querying the network total DC power
  value, but testing it for max(uin32_t) value, which seems to indicate
  that the charge controller is not part of a VE.Smart network.
* improve (verbose) logging, e.g., use _logId, and print names of
  response codes and known registers, always print error messages,
  add additional tests to prevent overly verbose messages.
* move hex protocol definitions to VeDirectData.h header
  and use enum classes
* define register addresses in enum class
* move values retrieved through hex protocol into main MPPT data struct
* do not send HEX requests if the serial interface cannot send data
* detect whether smart battery sense temperature is available
* web app: make all VE.Direct sub-cards iterable. this makes addind more
  values much simpler and saves a bunch of code in the web app.
* make VeDirectFrameHandler state a type-safe enum class
* unindent MPPT controller loop()
* whitespace cleanup
2024-04-03 16:33:15 +02:00
helgeerbe
5259fc172a Merge remote-tracking branch 'tbnobody/OpenDTU/master' into v24.3.15 2024-03-20 09:42:35 +01:00
Bernhard Kirchen
7d6b7252bf polish support for second VE.Direct MPPT charge controller
* fix compiler warning in SerialPortManager.cpp: function must not
  return void

* clean up and simplify implementation of usesHwPort2()
  * make const
  * overrides are final
  * default implementation returns false
  * implement in header, as the implementation is very simple

* rename PortManager to SerialPortManager. as "PortManager" is too
  generic, the static instance of the serial port manager is renamed to
  "SerialPortManager". the class is therefore renamed to
  SerialPortManagerClass, which is in line with other (static) classes
  withing OpenDTU(-OnBattery).

* implement separate data ages for MPPT charge controllers

* make sure MPPT data and live data time out

* do not use invalid data of MPPT controlers for calculations

* add :key binding to v-for iterating over MPPT instances
2024-03-17 16:50:15 +01:00
Arman Vartan
75541be248 Feature: Support for second Victron MPPT charge controller
this change adds support for a second Victron MPPT charge controller
using a second serial connection.

* Add device configuration for a second victron mppt
* Update VedirectView for second victron mppt
* Update MqttHandleVedirect for second victron mppt
* Update MqttHandleVedirectHass for second victron mppt
* Handle nonexisting victron controllers with optionals
* Add bool-function to Battery and inherited classes, if uart port 2 is
  being used
* Introduced a serial port manager. In order to prevent the battery and
  the Victron MPPT to use the same hw serial ports, this class keeps
  track of the used ports and their owners.
2024-03-17 16:50:15 +01:00
Thomas Basler
3138e28cdf webapp: Remove not required cast to string 2024-03-15 19:54:29 +01:00
Thomas Basler
a0d0aec677 Fix: Correct detection of Hoymiles serial if it contains hex characters 2024-03-15 19:46:24 +01:00
Bernhard Kirchen
2efa1b35b0 live view: do not access undefined data
if the respective feature is disabled, there is no data. do not try to
access it.
2024-03-15 08:55:21 +01:00
Thomas Basler
bd8d93bf92 Feature: Allow enabling and disabling of the version check
Fix #1787
2024-03-12 18:35:19 +01:00
Thomas Basler
9634c93a3c Fix: Show firmware update tooltip only if newer version available
Closes #1796
2024-03-12 17:27:43 +01:00
Thomas Basler
f995287a6e Feature: Add support for HERF inverters 2024-03-06 21:57:18 +01:00
Bernhard Kirchen
c560d1d90e
fix: copy OnBattery-specific data from live view websocket (#696)
closes #685.
closes #682.
2024-02-29 17:09:18 +01:00
helgeerbe
c72ae561c7 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2024-02-19 16:03:56 +01:00
Thomas Basler
8e01a275af Merge branch 'pr1693' into dev 2024-02-02 22:36:18 +01:00
Nikolaj Kappler
86b9625254 fix #1668
use builtin bootstrap css for scrolling
2024-02-02 22:34:58 +01:00
Thomas Basler
7e2064e264 Feature: Added support for boards with 16MB flash and PSRAM 2024-02-02 20:33:42 +01:00
helgeerbe
7094bca7db fix: Inverter Labels in InverterTotalInfo 2024-01-26 13:34:03 +01:00
helgeerbe
ebacc2f25f Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2024-01-25 23:36:32 +01:00
Thomas Basler
d99de94c00 webapp: Fix lint errors 2024-01-21 16:48:47 +01:00
Thomas Basler
4cfb1b1c26 Fix: PullToRefresh does not work anymore
It was using the wrong mainElement
2024-01-21 00:55:05 +01:00
Thomas Basler
8a80289474 Feature: Implement firmware update check is a opt-in to protect your privacy 2024-01-20 22:43:40 +01:00
Thomas Basler
9428eecce4 webapp: Use CardElement in InverterTotalInfo 2024-01-19 22:03:26 +01:00
Thomas Basler
6b31a4d470 webapp: Introduce Modal component
Less duplicated code
2024-01-19 21:36:18 +01:00
Thomas Basler
5d63f64411 webapp: Fix typo 2024-01-19 20:02:03 +01:00
Nikolaj Kappler
199351c703 webapp: Correctly center header text 2024-01-18 20:39:43 +01:00
Nikolaj Kappler
a7479d33e3 webapp: Reduce wasted horizontal space for better mobile UX 2024-01-18 20:39:43 +01:00
Nikolaj Kappler
41f3955429 webapp: Vertically center Header/Logo Text 2024-01-18 20:39:43 +01:00