this allows to use two VE.Direct interfaces, as there is no conflict
regarding HW serial port 2 after making the battery interfaces use
serial port 0 on devices with USB CDC. on those chips HW serial 0 is
free to be used since serial messages are written through the USB
interface directly.
we found that the inverter sometimes stops responding to commands,
especially to the "start producing" command. we now count the number of
consecutive timeouts when trying to send a new limit or power state
commands. after two timeouts were recorded, every additional timeout
will send a restart command to the inverter.
as a last resort, if the counter keeps climbing, the DTU is restarted.
notice that this only targets unresponsive inverters which are
reachable. unreachable inverters are not restarted and do not cause a
DTU reboot. this is important for solar-driven inverters, which are
unreachable during the night. the DPL will not calculate a new limit and
hence the updateInverter() method will do nothing while the target
inverter is unreachable.
publish the timeout counter to MQTT for monitoring purposes.
avoid performing a calculation based on a (slightly) outdated power
meter reading, which was aquired just before the limit was actually
applied by the inverter, but which was received by OpenDTU-OnBattery
after the inverter stats.
without a power meter configured, the DPL now sets the base load as the
inverter limit if the battery charge allows it. it also takes
solar-passthrough into account, i.e., if the battery is in a charge
cycle but the solar output (Victron MPPT) is significant, the solar
power will be used up until the base load. if the battery reaches the
full solar passthrough threshold, the DPL will match the inverter limit
to the MPPT solar output.
on power meter issues (usually a timeout), keep the inverter enabled and
make it produce the configured base load limit if the battery can be
discharged. that should be okay since the base load config value is
expected to be small and a little less than the actual household base
load, i.e., if this amount of power is produced, the household will
consume it in any case and no energy is fed into the grid.
makes the value match its description. since most values in the top part
of the live view are related to the AC side of the system, it makes
sense to use the correct value rather than to change the description.
* process "IL", "AR" and "MON"
* discard "BMV" and (unsolicited) History Data
* simplify isDataValid()
* veMpptStruct, veStruct: new, verbose variable names, including units,
and replace floats (save values with original integer precision)
* comment on rollover situation in isDataValid()
1. makes the DPL use the power generated by all connected charge
controllers for calculations based on solar passthrough.
2. makes the network total DC power appear as "MPPT Total Power" in the
live view at the top.
3. shows the network total DC power in the VE.Direct live data card.