Commit Graph

140 Commits

Author SHA1 Message Date
Bernhard Kirchen
15b6a32b92 Feature: support JSON payload in MQTT power meter
the MQTT power meter can now process the messages published at the
respective topics as JSON and extract a power value using a JSON path
(same as in HTTP+JSON power meter). additionally, selecting a unit for
the power value as well as an option to invert the value's sign was
added as well, similar to the HTTPS+JSON power meter.
2024-06-27 22:18:41 +02:00
Bernhard Kirchen
3f2d9d38fa powermeter refactor: fully structure settings per provider
all power meter providers now have their own configuration struct
defined. a respective method to serialize and deserialize the provider
config is implemented for each provider.
2024-06-27 22:18:41 +02:00
Bernhard Kirchen
20ecf2a66b powermeter refactor: add and use HttpGetter class
this new class uses the newly introduced HttpRequestConfig and performs
HTTP requests using this config. it will be reused for other power
meters (SML over HTTP(S)) and may be reused by other features in the
future (battery provider, solar power provider, etc.).
2024-06-27 22:18:41 +02:00
Bernhard Kirchen
297b149f84 powermeter refactor: generalize HTTP request config
the parameters to peform an HTTP request by the HTTP(S)+JSON power meter
have been generalized by introducing a new config struct. this is now
used for all values which the HTTP(S)+JSON power meter can retrieve, and
also used by the HTTP+SML power meter implementation. we anticipate that
other feature will use this config as well.

generalizing also allows to share serialization and deserialization
methods in the configuration handler and the web API handler, leading to
de-duplication of code and reduced flash memory usage.

a new web UI component is implemented to manage a set of HTTP request
settings.
2024-06-26 21:25:08 +02:00
Bernhard Kirchen
54c04aed61 SDM power meter: remove baud rate setting
this setting was not used. the baud rate for the SDM is set to 9600 in
the source code. until the baud rate being customizable is actually
required by somebody, we remove the setting altogether.
2024-06-26 20:51:56 +02:00
Marvin Carstensen
8ec1695d1b Feature: support Tibber bridge as power meter interface 2024-06-26 20:50:50 +02:00
Bernhard Kirchen
5e3a53d8d3 Merge upstream tag 'v24.6.10' into development 2024-06-21 16:45:41 +02:00
Andreas Böhm
83ac15405e
Feature: Implement DPL 'overscaling' to compensate shading (#956) 2024-06-20 13:32:29 +02:00
Thomas Basler
6e607f7f67 Feature: Add option to clear eventlog at midnight 2024-05-31 00:07:28 +02:00
Bernhard Kirchen
4cf596eb5a
Merge pull request #923 from helgeerbe/merge-v24.4.12
merge upstream tag v24.4.12, resolve conflicts (helgeerbe), fix eslint errors (schlimmchen) and adopt new web api method to save code duplication (schlimmchen).
2024-04-29 21:17:14 +02:00
helgeerbe
fdc5054480 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into merge-v24.4.12 2024-04-25 20:59:19 +02:00
MalteSchm
f0df583c13
Feature: support for Huawei target power consumption 2024-04-24 20:26:56 +02:00
Bernhard Kirchen
abe01ae36f Feature: HTTP power meter: support changing sign 2024-04-18 12:10:29 +02:00
Bernhard Kirchen
ede1abb5e6 Feature: HTTP power meter: support mW/kW as units 2024-04-18 12:10:29 +02:00
Bernhard Kirchen
e92701ccdf reuse power meter's HTTP config struct 2024-04-18 12:10:29 +02:00
Bernhard Kirchen
7e307114e5 Feature: DPL: introduce base load setting
on power meter issues (usually a timeout), keep the inverter enabled and
make it produce the configured base load limit if the battery can be
discharged. that should be okay since the base load config value is
expected to be small and a little less than the actual household base
load, i.e., if this amount of power is produced, the household will
consume it in any case and no energy is fed into the grid.
2024-04-15 23:02:58 +02:00
eu-gh
0ed09aeb4c Feature: Huawei: add SoC stop threshold and verbose logging switch 2024-04-07 17:16:50 +02:00
Thomas Basler
2e3125fe8d Feature: Migrated ArduinoJson 6 to 7 2024-04-05 19:14:56 +02:00
helgeerbe
ff44267e73 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into merge-v24.3.31 2024-04-03 11:53:03 +02:00
MalteSchm
8abf614047 Feature: BMS initiated emergency charging
This change logically connects the AC-Charger with the BMS to add BMS
initiated emergency charging and respecting BMS current limits.
2024-04-02 21:05:00 +02:00
Thomas Basler
6f3b8fb8e1 Fix: Change default NTP server
Fixes #1877
2024-03-31 12:27:27 +02:00
helgeerbe
03435f66ee Feature: Set max number of supported Inverters to 10 (upstream default)
Due to the latest live view api changes, I revert the maximum number of supported inverters to the upstream default (10).
2024-03-22 13:50:16 +01:00
Bernhard Kirchen
b449dd1196 replace VICTRON_MAX_COUNT
determine the amount of controllers actually in use dynamically,
especially to avoid indices which are invalid, causing an error
to be printed, even though the user did not do anything wrong.
2024-03-20 22:11:11 +01:00
helgeerbe
5259fc172a Merge remote-tracking branch 'tbnobody/OpenDTU/master' into v24.3.15 2024-03-20 09:42:35 +01:00
Bernhard Kirchen
13bc943dd5 Feature: Refactor/Simplify DPL settings
this changeset refactors the web application's DPL settings view. the
DPL settings can be complex, and they shall be presented in a way that
allows users to comprehend their meaning. irrelevant settings are now
hidden or displayed dynamically based on the influencing settings.

* group SoC thresholds into their own card

* hide battery SoC thresholds if battery disabled. if the user did not
  even enable the battery interface, battery SoC values will not be used
  for DPL decisions. in that case we completely hide the respective
  settings from the DPL admin view. this reduces the amount of settings
  for new users and especially users who don't even have a battery in
  their setup or have no BMS connected.

* group voltage thresholds and improve label texts

* fix load correction factor unit

* fix header (wording)

* group solar-passthrough settings in new card

* group inverter-related settings

* hide solar passthrough settings if VE.Direct is disabled. closes #662.

* completely disable form if any requirement is not met

* list available inverters by name and type. this makes it much more
  convenient to select the right inverter, especially since the order of
  the inverters in the web UI is decoupled from their position in the
  internal array, which was used to select them previously. care was
  taken that old configs select the same inverter after an update.
  when editing the DPL settings, the selects an inverter from the newly
  created drow-down list, and the respective old inverter is
  pre-selected.

* disable form if no inverter is configured (config alert)

* make inverter input selection dynamic. adjust selection to actual
  amount of channels for selected inverter. skip selection altogether if
  inverter has only one channel, or if it is solar powered.

* web app: wording adjustments

* group meta data into new property and exclude from submission. saves
  memory when evaluating the submitted settings.

* hide irrelevant settings if inverter is solar-powered

* move restart hour setting to inverter card. translate setting which
  disabled automatic restart.

* simplify "drain strategy" setting into an on/off toggle. care was
  taken that existing configs work the same after an upgrade. the
  respective drain strategy is translated into the new setting when
  reading the config. once the config is written, the new setting is
  persisted and the old is not part of the config any more.

* show more configuration hints, depending on actual configuration

* replace inputs by InputElement components where possible
2024-03-17 16:50:57 +01:00
Arman Vartan
75541be248 Feature: Support for second Victron MPPT charge controller
this change adds support for a second Victron MPPT charge controller
using a second serial connection.

* Add device configuration for a second victron mppt
* Update VedirectView for second victron mppt
* Update MqttHandleVedirect for second victron mppt
* Update MqttHandleVedirectHass for second victron mppt
* Handle nonexisting victron controllers with optionals
* Add bool-function to Battery and inherited classes, if uart port 2 is
  being used
* Introduced a serial port manager. In order to prevent the battery and
  the Victron MPPT to use the same hw serial ports, this class keeps
  track of the used ports and their owners.
2024-03-17 16:50:15 +01:00
Thomas Basler
33bf2117c6 Fix: Set all settings to default when deleting an inverters
Previously some old settings from previous inverters could have been shown in a new inverter
2024-03-13 18:47:28 +01:00
Bernhard Kirchen
b11b1dbcba DPL: define IsInverterSolarPowered config switch 2024-03-08 22:53:34 +01:00
Bernhard Kirchen
3595725f8a Feature: implement subscription to battery voltage MQTT topic
this extends the MqttBattery implementation by an additional topic which
allows to subscribe to receive battery voltage readings through the MQTT
broker. similar to the battery SoC topic, this allows to import a
critical battery data point for the DPL, in case the user chooses to use
voltage thresholds rather than SoC thresholds to control the DPL. if an
otherwise incompatible BMS is available which publishes the battery pack
voltage through MQTT, this can now be used to feed accurate voltage
readings to the DPL.
2024-02-18 22:17:15 +01:00
Bernhard Kirchen
921302bf73 Feature: DPL: add switch allowing to ignore SoC
unfortunately, the battery SoC values reported by battery BMSs are
unreliable, at least for some users, or at least without regular
(manual) full charge cycles to calibrate the BMS. it offers great
advantages to connect OpenDTU-OnBattery to a BMS (MQTT publishing of
values, Home Assistent integration, etc.), but previously the users
were then forced to configure the DPL by SoC values.

this change allows to configure the DPL such that SoC values are
ignored. instead, the voltage limits are used to make DPL decisions, as
if no SoC was available in the first place.

the SoC related setting are hidden from the DPL settings view if SoC
values are configured to be ignored.

closes #654.
2024-02-18 21:46:42 +01:00
helgeerbe
63205f88be Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2024-01-16 17:39:45 +01:00
Thomas Basler
c20caf8097 Feature: Support HMS/HMT inverters in different countries with different frequency bands
Thanks to @Fribur, @homeautomation2022 and @stefan123t
2024-01-14 16:37:34 +01:00
Thomas Basler
ee78698e37 Migrate all frequency calculations to Hz
Previously the code contains calculations  using a mixture  of kHz and Hz.

Thanks to @Fribur
2024-01-13 12:51:20 +01:00
Thomas Basler
637d4f06a3 Feature: Added option to disable the diagram at the display 2024-01-08 14:19:26 +01:00
Thomas Basler
a65f1e48a5 Fix: Access Point not working after firmware update
Fixes #1613
2024-01-05 21:55:15 +01:00
Bernhard Kirchen
e7a005839b
Feature: implement MQTT-driven battery provider (#589)
this battery provider implementation subscribes to a user-configurable
MQTT topic to retrieve the battery SoC value. the value is not
re-published under a different topic. there is no card created in the
web app's live view, since the SoC is already part of the totals at the
top of the live view. that is the only info this battery provider
implements.

closes #293.
relates to #581.
2024-01-04 15:42:10 +01:00
Thomas Basler
c1fc907ecb Fix: Access Point not working after firmware update
Fixes #1613
2024-01-03 22:04:50 +01:00
helgeerbe
d494810975
merge V23.12.16 (#556)
* Optimize Sun data calculation

* Remove not required enum

* Split config struct into different sub structs

* Feature: Allow configuration of LWT QoS

* Made resetreason methods static

* Feature: Implement offset cache for "YieldDay"

Thanks to @broth-itk for the idea!
Fix: #1258 #1397

* Add Esp32-Stick-PoE-A

* remove broken LilyGO_T_ETH_POE config, use device profile instead

* Feature: High resolution Icon and PWA (Progressive Web App) functionality

Fix: #1289

* webapp: Update dependencies

* Initialize TaskScheduler

* Migrate SunPosition to TaskScheduler

* Migrate Datastore to TaskScheduler

* Migrate MqttHandleInverterTotal to TaskSchedule

* Migrate MqttHandleHass to TaskScheduler

* Migrate MqttHandleDtu to TaskScheduler

* Migrate MqttHandleInverter to TaskScheduler

* Migrate LedSingle to TaskScheduler

* Migrate NetworkSettings to TaskScheduler

* Migrate InverterSettings to TaskScheduler

* Migrate MessageOutput to TaskScheduler

* Migrate Display_Graphic to TaskScheduler

* Migrate WebApi to TaskScheduler

* Split InverterSettings into multiple tasks

* Calculate SunPosition only every 5 seconds

* Split LedSingle into multiple tasks

* Upgrade espMqttClient from 1.4.5 to 1.5.0

* Doc: Correct amount of MPP-Tracker

* Added HMT-1600-4T and HMT-1800-4T to DevInfoParser

Fix #1524

* Adjusted inverter names for HMS-1600/1800/2000-4T

* Add channel count to description of detected inverter type (DevInfoParser)

* Adjust device web api endpoint for dynamic led count

* Feature: Added ability to change the brightness of the LEDs

Based on the idea of @moritzlerch with several modifications like pwmTable and structure

* webapp: Update dependencies

* Update olikraus/U8g2 from 2.35.7 to 2.35.8

* Remove not required onWebsocketEvent

* Remove code nesting

* Introduce several const statements

* Remove not required AsyncEventSource

* Doc: Added byte specification to each command

* Feature: Added basic Grid Profile parser which shows the used profile and version

Other values are still outstanding.

* Optimize AlarmLogParser to save memory

* Add libfrozen to project to create constexpr maps

* Feature: First version of GridProfile Parser which shows all values contained in the profile.

* webapp: Update dependencies

* Apply better variable names

* Remove not required casts

* Add additional compiler flags to prevent errors

* Add const statement to several variables

* Replace NULL by nullptr

* Update bblanchon/ArduinoJson from 6.21.3 to 6.21.4

* Add const keyword to method parameters

* Add const keyword to methods

* Use references instead of pointers whenver possible

* Adjust member variable names in MqttSettings

* Adjust member variable names in NetworkSettings

* webapp: Update timezone database to latest version

* webapp: Beautify and unify form footers

* Feature: Allow setting of an inverter limit of 0% and 0W

Thanks to @madmartin in #1270

* Feature: Allow links in device profiles

These links will be shown on the hardware settings page.

* Doc: Added hint regarding HMS-xxxx-xT-NA inverters

* Feature: Added DeviceProfile for CASmo-DTU

Based on #1565

* Upgrade actions/upload-artifact from v3 to v4

* Upgrade actions/download-artifact from v3 to v4

* webapp: add app.js.gz

* Gridprofileparser: Added latest known values

Thanks to @stefan123t and @noone2k

* webapp: Fix lint errors

* Feature: Add DTU to Home Assistant Auto Discovery

This is based on PR 1365 from @CFenner with several fixes and optimizations

* Fix: Remove debug output as it floods the console

* Fix: Gridprofileparser: Add additional error handling if profile is unknown

* webapp: add app.js.gz

* Fix: Offset cache for "YieldDay" did not work correctly

* webapp: update dependencies

* webapp: add app.js.gz

* Fix: yarn.lock was outdated

* Fix: yarn build error

* Fix: Reset Yield day correction in combination with Zero Yield Day on Midnight lead to wrong values.

* Fix: Allow negative values in GridProfileParser

* Correct variable name

* Fix #1579: Static IP in Ethernet mode did not work correctly

* Feature: Added diagram to display

This is based on the idea of @Henrik-Ingenieur and was discussed in #1504

* webapp: update dependencies

* webapp: add app.js.gz

---------

Co-authored-by: Thomas Basler <thomas@familie-basler.net>
Co-authored-by: Pierre Kancir <pierre.kancir.emn@gmail.com>
2023-12-27 11:49:57 +01:00
Thomas Basler
0ddc7fd28d Feature: Added diagram to display
This is based on the idea of @Henrik-Ingenieur and was discussed in #1504
2023-12-19 17:26:24 +01:00
Thomas Basler
d6494fa791 Add const keyword to method parameters 2023-12-12 00:21:14 +01:00
Thomas Basler
9ae791edd4 Feature: Added ability to change the brightness of the LEDs
Based on the idea of @moritzlerch with several modifications like pwmTable and structure
2023-12-07 12:46:38 +01:00
Thomas Basler
1de3b48166 Feature: Implement offset cache for "YieldDay"
Thanks to @broth-itk for the idea!
Fix: #1258 #1397
2023-11-22 20:21:25 +01:00
Thomas Basler
ee4811bbe7 Feature: Allow configuration of LWT QoS 2023-11-19 16:17:10 +01:00
Thomas Basler
b85c53f476 Split config struct into different sub structs 2023-11-19 14:53:26 +01:00
helgeerbe
0085970567 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-11-16 09:20:08 +01:00
CommanderRedYT
7c875187a8
Implemented mDNS 2023-10-30 20:53:45 +01:00
Bernhard Kirchen
4d4aadf8de
Feature: AC charger: configurable CAN controller frequency (#500) 2023-10-19 16:16:01 +02:00
helgeerbe
f7bd4a40d8 revert Revert "Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development"
merge of v23.9.11 broke the system. As a workaround upgrade espressif32 from 6.3.2 to 6.4.0 is skipped. See #440
2023-09-14 13:45:23 +02:00
helgeerbe
2eeb5f1d19 Revert "Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development"
This reverts commit eb1c2dbd8c, reversing
changes made to 0cb42a6424.

merge of v23.9.11 broke the system
2023-09-12 20:18:10 +02:00
helgeerbe
eb1c2dbd8c Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-09-12 19:27:32 +02:00