Commit Graph

6 Commits

Author SHA1 Message Date
Bernhard Kirchen
5a1c3af31f Feature: add support for a third Victron MPPT
only on ESP32-S3-USB. this fiddles with the available hardware UARTs to
make it possible to use a third Victron MPPT. if three MPPTs are defined
int the pin mapping, you will not be able to use the SmartShunt and JK
BMS battery interfaces.

note that using a second MPPT will also conflict with the SDM power
meter, and that conflict is not detected, yet.
2024-06-02 22:41:07 +02:00
Bernhard Kirchen
4e36c8c9ea
Feature: battery interface: use HW serial 0 on ESP32-C3 or S3 (#933)
this allows to use two VE.Direct interfaces, as there is no conflict
regarding HW serial port 2 after making the battery interfaces use
serial port 0 on devices with USB CDC. on those chips HW serial 0 is
free to be used since serial messages are written through the USB
interface directly.
2024-04-29 20:43:35 +02:00
Bernhard Kirchen
7d6b7252bf polish support for second VE.Direct MPPT charge controller
* fix compiler warning in SerialPortManager.cpp: function must not
  return void

* clean up and simplify implementation of usesHwPort2()
  * make const
  * overrides are final
  * default implementation returns false
  * implement in header, as the implementation is very simple

* rename PortManager to SerialPortManager. as "PortManager" is too
  generic, the static instance of the serial port manager is renamed to
  "SerialPortManager". the class is therefore renamed to
  SerialPortManagerClass, which is in line with other (static) classes
  withing OpenDTU(-OnBattery).

* implement separate data ages for MPPT charge controllers

* make sure MPPT data and live data time out

* do not use invalid data of MPPT controlers for calculations

* add :key binding to v-for iterating over MPPT instances
2024-03-17 16:50:15 +01:00
Arman Vartan
75541be248 Feature: Support for second Victron MPPT charge controller
this change adds support for a second Victron MPPT charge controller
using a second serial connection.

* Add device configuration for a second victron mppt
* Update VedirectView for second victron mppt
* Update MqttHandleVedirect for second victron mppt
* Update MqttHandleVedirectHass for second victron mppt
* Handle nonexisting victron controllers with optionals
* Add bool-function to Battery and inherited classes, if uart port 2 is
  being used
* Introduced a serial port manager. In order to prevent the battery and
  the Victron MPPT to use the same hw serial ports, this class keeps
  track of the used ports and their owners.
2024-03-17 16:50:15 +01:00
Bernhard Kirchen
a012d81427
avoid too frequent SmartShunt data copies (#596)
currently the whole SmartShunt data structure is copied to the
BatteryStats instance in every loop, even though the data cannot
possibly have changed. this is quite an expensive task to do in every
loop. this change tracks the last update timestamp and only does the
copy operation if an actual updated data structure was received from
the smart shunt.
2024-01-07 18:30:02 +01:00
Philipp Sandhaus
7142921021
Integration of Victron SmartShunt via VE.Direct (#452)
* Move Mppt logic to subclass

* Added Definitions for Shunts and restructering

* First integration of SmartShunt data into Web Interface

* Code cleanup

* VE.Direct: whitespace cleanup

* VE.Direct: manage HardwareSerial in unique_ptr

* VE.Direct: _efficiency is only needed by MPPT

* VE.Direct: keep as many members private as possible

* VE.Direct: use int8_t for pins (as before)

* VictronSmartShunt: _verboseLogging is not used

* VE.Direct: OR (off reason) is MPPT specific

it also applies to Phoenix inverters and Smart BuckBoost, but since
there is no support for those, the code is moved to the MPPT controller.

* Added Shunt alarms to liveview
Changed from double to int for several readings

* Update build.yml to allow manual builds

---------

Co-authored-by: Philipp Sandhaus <philipp.sandhaus@cewe.de>
Co-authored-by: Bernhard Kirchen <schlimmchen@posteo.net>
2023-09-22 17:24:57 +02:00