Commit Graph

26 Commits

Author SHA1 Message Date
Thomas Basler
4031b71d7d Implemented resend of PowerCommand 2022-10-04 18:12:55 +02:00
Thomas Basler
6cbcfacac6 Renamed several methods from Sample to Simple 2022-10-03 13:14:31 +02:00
Thomas Basler
754913368a Implemented way to periodically fetch the current limit from the inverter
The fetch is only executed at least 4 minutes after the last set command.
Otherwise it would generate a entry in the event log (ID 2)
2022-09-30 18:34:30 +02:00
Thomas Basler
3153ee4993 Implemented getTimeout method in AlarmDataCommand 2022-09-30 18:34:30 +02:00
Thomas Basler
a707ab501d Implemented method to check whether the last command was successfull
This also allows to retransmit the command after specific time if not successfull
2022-09-30 18:34:30 +02:00
Thomas Basler
b8f03eddfd Fixed scheduler issue
When the RF method took very long inverters where skipped
2022-09-25 17:28:50 +02:00
Thomas Basler
b7961024a1 Fetch limit every 10 minutes 2022-09-09 20:17:52 +02:00
Thomas Basler
3e5fb00248 Fetch inverter limit at least once 2022-09-09 18:41:54 +02:00
Thomas Basler
26268479fb Fix #96 and #95 : Reworked handling of inverter editing 2022-08-24 02:53:34 +02:00
Thomas Basler
1456974616 Fix #76: Null Pointer exception when adding a inverter with unkonwn serial number 2022-08-16 19:47:51 +02:00
Thomas Basler
528c56eaa6 Added parser and commands for hardware version and part nr 2022-08-10 20:12:52 +02:00
Thomas Basler
c3a043b1ce Improve handling of firmware data fetch 2022-08-10 19:03:02 +02:00
Thomas Basler
8715320282 Implemented DevInfo command 2022-08-10 19:03:02 +02:00
Thomas Basler
ef5d549f8a Fix exception when deleting a inverter 2022-08-09 21:46:40 +02:00
Thomas Basler
dcc7e47b19 Hoymiles: Introduce init method to have a clean init on beginning
Constructor is not possible for obvious reasons
2022-07-18 21:30:12 +02:00
Thomas Basler
b9bb753906 First try to implement Alarm Log fetching 2022-07-08 18:22:35 +02:00
Thomas Basler
b2271373a4 Print inverter serial as hex 2022-06-30 21:06:23 +02:00
Thomas Basler
ab6261da92 Move the whole stats request into the inverter class
This enables in future releases so send multiple requests for e.g. MI inverters
2022-06-27 19:26:16 +02:00
Thomas Basler
db0a3da803 Generate a second class abstraction to support different inverter types in future 2022-06-24 17:49:14 +02:00
Thomas Basler
f42696d14c Fix change of inverter serial
Because of the inverter type depends on the serial number it's a must to remove and add the inverter of the serial was changed. setSerial doesn't make sense anymore. Move the serial to the constructor
2022-06-22 21:32:37 +02:00
Thomas Basler
52b5cdbdb6 Remove not required include 2022-06-16 14:34:21 +02:00
Thomas Basler
bab5beb170 Move strings from RAM to Flash 2022-06-15 22:21:50 +02:00
Thomas Basler
c9e603b2de Replace EVERY_N_SECONDS with millis
EVERY_N_SECONDS is not updated without a reboot of the controller
2022-06-15 22:15:02 +02:00
Thomas Basler
9bfe6a9e63 First simple implementation of polling algorithm 2022-06-15 19:23:47 +02:00
Thomas Basler
0d9b994c92 Added function t retrieve a inverter just by a given payload fragment 2022-05-31 19:29:05 +02:00
Thomas Basler
0d07e3e09f WIP: Very rough first draft of Hoymiles library 2022-05-30 21:50:08 +02:00