Commit Graph

1124 Commits

Author SHA1 Message Date
Bernhard Kirchen
54c04aed61 SDM power meter: remove baud rate setting
this setting was not used. the baud rate for the SDM is set to 9600 in
the source code. until the baud rate being customizable is actually
required by somebody, we remove the setting altogether.
2024-06-26 20:51:56 +02:00
Bernhard Kirchen
d99cfd5b31 powermeter refactor: publish values to MQTT in base class
"powertotal" is always published and it is published by the base class
directly. other values are still published by the derived classes, but
use a base class method, which takes care that a common base topic is
used in particular.
2024-06-26 20:51:56 +02:00
Bernhard Kirchen
d4c07836d9 MQTT powermeter: avoid iterating subscriptions
instead of iterating a map with subscriptions, we now bind the target
variable to the callback, which is executed once a message is arrived.
this way, the target variable is already linked to the respective topic
when the callback is executed.

lock the mutex when writing the variable, as the MQTT callback is
executed in a different context (MQTT task) than the main loop task,
which otherwise accesses the variables.
2024-06-26 20:51:56 +02:00
Bernhard Kirchen
5cd6334880 powermeter refactor: avoid reboot on settings change
the current power meter provider will be de-initialized, and a new
instance will be initialized with the new settings.
2024-06-26 20:51:56 +02:00
Bernhard Kirchen
33683d26c8 powermeter refactor: rename providers in enum
the enum values did not change, but their name (only relevant in the
code) are now more expressive.
2024-06-26 20:51:56 +02:00
Bernhard Kirchen
2397e5cdf5 powermeter refactor: split providers into their own classes
it is important to separate the capabilities of each power meter
provider into their own class/source file, as the providers work
fundamentally different and their implementations must not be
intermangled, which made maintenance and improvements a nightmare
in the past.
2024-06-26 20:51:54 +02:00
Marvin Carstensen
8ec1695d1b Feature: support Tibber bridge as power meter interface 2024-06-26 20:50:50 +02:00
Bernhard Kirchen
83c59d7811 convert files with CRLF endings to LF endings
this only changes line endings. inspect this commit with command `git
show <commit-sha> --ignore-space-at-eol` and it will tell you that the
commit appears to be "empty" (since all changes are whitespace changes
near the end of a line, which are ignored in that git show command).

the files to be changed were found and updated using this command:
find lib src include webapp/src -type f | \
    xargs grep --binary-files=without-match --files-with-matches \
    $(printf '\r\n') | xargs dos2unix

the following files were restored afterwards, as they are using CRLF
line endings in the upstream as well:
 - lib/CMT2300a/cmt2300a_defs.h
 - lib/README
 - include/README
2024-06-24 21:57:12 +02:00
Andreas Böhm
79214d750f
refactor PylontechCanBattery to be more generic (#1064) 2024-06-23 19:42:04 +02:00
Bernhard Kirchen
f21f58c67d adjust MessageOutput for changes in espressif/arduino-esp32
the "serial console" over USB would be garbled badly after switching to
"platform = espressif32@6.7.0". this did not happen to the upstream
version of MessageOutput. we used Serial.flush(), which seemed to be
good in the respective context. however, the changes in

github.com/espressif/arduino-esp32/pull/9462

made flush() detrimental. we remove the use of flush(), as it seems not
to be required (in particular, the upstream project does not use it).
2024-06-21 16:57:17 +02:00
Bernhard Kirchen
034026f782 restore JK BMS dummy implementation
broke in be41e6b9. was unusable as the complete type of DummySerial has
to be available in the JK BMS controller header when defining the
unique_ptr managing the dummy instance. this problem is solved by moving
the whole dummy class into its own header.
2024-06-21 16:57:11 +02:00
Bernhard Kirchen
5e3a53d8d3 Merge upstream tag 'v24.6.10' into development 2024-06-21 16:45:41 +02:00
Andreas Böhm
83ac15405e
Feature: Implement DPL 'overscaling' to compensate shading (#956) 2024-06-20 13:32:29 +02:00
cerise21
ccbaf55808
Feature: Set/obtain DPL target power consumption via MQTT 2024-06-20 13:25:41 +02:00
cerise21
1f6fdb7fc0
Feature: Set/obtain DPL upper power limit via MQTT 2024-06-15 20:21:42 +02:00
Bernhard Kirchen
5a007e5352 fix: make SDM power meter use serial port manager
instead of hard-coding the use of hardware UART 2, the SDM power meter
instance now asks for a free hardware serial port to use and
instanciates the respective HardwareSerial object using said port.
2024-06-02 22:41:07 +02:00
Bernhard Kirchen
be41e6b906 refactor serial port manager: hand out UARTs FCFS
get rid of particular compile-time designations by UART index. just hand
out the next free index of hardware UARTs, or indicate that none is
available any more.

use names as keys to register and free UARTs.
2024-06-02 22:41:07 +02:00
Bernhard Kirchen
5a1c3af31f Feature: add support for a third Victron MPPT
only on ESP32-S3-USB. this fiddles with the available hardware UARTs to
make it possible to use a third Victron MPPT. if three MPPTs are defined
int the pin mapping, you will not be able to use the SmartShunt and JK
BMS battery interfaces.

note that using a second MPPT will also conflict with the SDM power
meter, and that conflict is not detected, yet.
2024-06-02 22:41:07 +02:00
Bernhard Kirchen
c22ae2bf8d Feature: show BMS FW and HW version (JK BMS, SmartShunt) 2024-06-01 11:23:22 +02:00
swingstate
561f4be6d6 Feature: SmartShunt: process midpoint voltage and deviation 2024-05-31 21:08:15 +02:00
Bernhard Kirchen
88314f93c2 Fix: properly format Victron MPPT firmware version 2024-05-31 20:16:29 +02:00
Thomas Basler
b27a476507 Fix: Apply inverter settings only once and not for each channel 2024-05-31 00:56:15 +02:00
Thomas Basler
35aa835891 Merge branch 'pr2022' into dev 2024-05-31 00:52:28 +02:00
Stefan Oberhumer
8e8c463849 NFC: Includes list: Remove unneeded PinMapping.h 2024-05-31 00:30:15 +02:00
Thomas Basler
6e607f7f67 Feature: Add option to clear eventlog at midnight 2024-05-31 00:07:28 +02:00
eu-gh
90eb25f503
Fix: Huawei PSU: enforce BatterySoC Limit < 100 in UI (#992) 2024-05-30 21:31:46 +02:00
ButterBetzi
27f264e99b feature: JK BMS: HA auto-discovery for battery temperatures 2024-05-30 21:21:14 +02:00
Bernhard Kirchen
19c8866dd4 fix: Victron MPPT HA auto-discovery: fix unit of temperatures 2024-05-30 20:13:47 +02:00
Thomas Basler
6ce474053e Feature: Show MCU temperature in system info 2024-05-28 23:24:08 +02:00
Thomas Basler
24983acf17 Merge branch 'pr2015' into dev 2024-05-28 20:13:22 +02:00
Bernhard Kirchen
bdc9c09db2 Feature: show ESP32 flash memory size in system info 2024-05-27 21:54:35 +02:00
Bernhard Kirchen
4972892d9a Feature: show ESP32 flash memory size in system info 2024-05-27 21:52:49 +02:00
Thomas Basler
918c3449da Fix #2000: MQTT subscriptions where not updated if MQTT base was changed 2024-05-20 17:56:59 +02:00
Bernhard Kirchen
841523f028 embrace upstream __compiled_constants.h approach 2024-05-07 22:04:36 +02:00
Bernhard Kirchen
255e81e6bd Merge upstream tag 'v24.5.6' into development 2024-05-07 22:03:26 +02:00
Bernhard Kirchen
e1169d4b11 Fix: restore JSON array access for HTTP power meter
this implements accessing array members in an ArduinoJSON object
following the FirebaseJson syntax. the FirebaseJson lib was previously
removed to save flash memory, and logic was implemented to find a JSON
node using the FirebaseJson path syntax, restoring the functionality.
however, array access was not implemented.

this change also addresses leading and trailing and double forward
slashes in the path expression.

moreover, much more expressive error messages are now generated in case
the path could not be resolved.
2024-05-07 20:56:58 +02:00
Alexander Kukushkin
2f7e1f3f70
Fix: solar_passthrough_losses setting persistence (#957)
Due to a typo the value of `solar_passtrough_losses` was lost after a restart.
2024-05-06 11:12:25 +02:00
Bernhard Kirchen
b7a8bdf07b remove rweather/Crypt lib from firmware (save 2.1k of flash)
mbedtls is already integral part of the firmware. use it in favor of
rweather/Crypto library to calculate a sha256 checksum of a string, as
used in the HTTP power meter implementation.
2024-05-06 11:04:24 +02:00
Bernhard Kirchen
1dd64a57fd remove FirebaseJson lib from firmware (save 17.5k of flash)
we used this library solely to interpret the answer of an HTTP web
server as JSON and find a particular value using a path expression in
the HTTP power meter implementation.

since we ran out of flash memory on non-S3 ESP32, we need to cut some
corners. removing FirebaseJson is the last low-hanging fruit that we
currently know of. we can get rid of it by using ArduinoJson (which is
already integral part of the firmware) and implementing a custom logic
to extract a value based on a path expression.

other than the FirebaseJson path "finder", the new implementation
only knows how to access sub-keys delimited by a forward slash. in
particular, accessing array members is not supported any more. I am
hoping that this is simply not an issue. if so, we will have users
complaining and we can add this functionality in a later release.
2024-05-06 11:04:24 +02:00
Thomas Basler
7d2fb3490e Fix #1960: Prometheus API return wrong information in function addPanelInfo 2024-05-04 22:24:40 +02:00
eu-gh
686b5df64e
Feature: Publish Huawei AC charger mode via MQTT (#876) 2024-05-02 21:19:25 +02:00
Thomas Basler
d5a24906fa Merge branch 'pr1920' into dev 2024-05-02 20:59:26 +02:00
Bernhard Kirchen
18dab3cf1c Merge upstream tag 'v24.4.24' into development 2024-05-02 20:49:41 +02:00
Bernhard Kirchen
4cf596eb5a
Merge pull request #923 from helgeerbe/merge-v24.4.12
merge upstream tag v24.4.12, resolve conflicts (helgeerbe), fix eslint errors (schlimmchen) and adopt new web api method to save code duplication (schlimmchen).
2024-04-29 21:17:14 +02:00
Bernhard Kirchen
4e36c8c9ea
Feature: battery interface: use HW serial 0 on ESP32-C3 or S3 (#933)
this allows to use two VE.Direct interfaces, as there is no conflict
regarding HW serial port 2 after making the battery interfaces use
serial port 0 on devices with USB CDC. on those chips HW serial 0 is
free to be used since serial messages are written through the USB
interface directly.
2024-04-29 20:43:35 +02:00
Bernhard Kirchen
84e83f2dbb adopt WebApiClass::parseRequestData() method
saves redundant code, reducing flash usage.
2024-04-29 20:31:50 +02:00
MalteSchm
64738a6246 Introducing defines for RX2/TX2 2024-04-25 22:54:12 +02:00
helgeerbe
fdc5054480 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into merge-v24.4.12 2024-04-25 20:59:19 +02:00
Thomas Basler
f8cc171e4a Fix: Return 404 (and nothing else) if file not found 2024-04-24 22:15:25 +02:00
MalteSchm
f0df583c13
Feature: support for Huawei target power consumption 2024-04-24 20:26:56 +02:00
Bernhard Kirchen
74330a5617 Feature: restart unresponsive inverter
we found that the inverter sometimes stops responding to commands,
especially to the "start producing" command. we now count the number of
consecutive timeouts when trying to send a new limit or power state
commands. after two timeouts were recorded, every additional timeout
will send a restart command to the inverter.

as a last resort, if the counter keeps climbing, the DTU is restarted.

notice that this only targets unresponsive inverters which are
reachable. unreachable inverters are not restarted and do not cause a
DTU reboot. this is important for solar-driven inverters, which are
unreachable during the night. the DPL will not calculate a new limit and
hence the updateInverter() method will do nothing while the target
inverter is unreachable.

publish the timeout counter to MQTT for monitoring purposes.
2024-04-24 16:15:01 +02:00
Bernhard Kirchen
eb9bfd1ac6 Fix: DPL mode 2 for solar-powered inverters
for solar-powered inverters, the unconditional full solar-passthrough
implementation now sets the upper limit configured in the DPL settings.
2024-04-22 12:51:31 +02:00
Bernhard Kirchen
1d4bea24ff Fix: JK BMS: BMS name is second part of product ID 2024-04-18 16:36:11 +02:00
Bernhard Kirchen
4cd690de66 VE.Direct: publish data retrieved from HEX protocol 2024-04-18 13:06:37 +02:00
Bernhard Kirchen
abe01ae36f Feature: HTTP power meter: support changing sign 2024-04-18 12:10:29 +02:00
Bernhard Kirchen
ede1abb5e6 Feature: HTTP power meter: support mW/kW as units 2024-04-18 12:10:29 +02:00
Bernhard Kirchen
247cfe712e HTTP power meter: prevent out-of-bound array access 2024-04-18 12:10:29 +02:00
Bernhard Kirchen
e92701ccdf reuse power meter's HTTP config struct 2024-04-18 12:10:29 +02:00
Stefan Oberhumer
97800434c4 Prevent compiling the whole project on each commit.
Putting the git information into a generated sourcefile prevents
recompiling the whole project after each commit.
2024-04-18 09:02:57 +02:00
Bernhard Kirchen
4bc4defe66 DPL: insist on power meter value more recent than inverter stats
avoid performing a calculation based on a (slightly) outdated power
meter reading, which was aquired just before the limit was actually
applied by the inverter, but which was received by OpenDTU-OnBattery
after the inverter stats.
2024-04-15 23:02:58 +02:00
Bernhard Kirchen
52d7ac9581 Feature: DPL: support setups without power meter
without a power meter configured, the DPL now sets the base load as the
inverter limit if the battery charge allows it. it also takes
solar-passthrough into account, i.e., if the battery is in a charge
cycle but the solar output (Victron MPPT) is significant, the solar
power will be used up until the base load. if the battery reaches the
full solar passthrough threshold, the DPL will match the inverter limit
to the MPPT solar output.
2024-04-15 23:02:58 +02:00
Bernhard Kirchen
7e307114e5 Feature: DPL: introduce base load setting
on power meter issues (usually a timeout), keep the inverter enabled and
make it produce the configured base load limit if the battery can be
discharged. that should be okay since the base load config value is
expected to be small and a little less than the actual household base
load, i.e., if this amount of power is produced, the household will
consume it in any case and no energy is fed into the grid.
2024-04-15 23:02:58 +02:00
Thomas Basler
bf49410f6d Merge branch 'pr1909' into dev 2024-04-12 17:05:51 +02:00
Bernhard Kirchen
4c2822cdbc remove usage of F() macro
frees 888 Bytes of flash.
2024-04-12 15:33:47 +02:00
Bernhard Kirchen
153293e1c7 remove remaining usage of F() macro 2024-04-12 15:28:26 +02:00
Bernhard Kirchen
8b3a1bef47 Fix: show AC input power of Huawei AC charger in live view
makes the value match its description. since most values in the top part
of the live view are related to the AC side of the system, it makes
sense to use the correct value rather than to change the description.
2024-04-11 14:27:47 +02:00
Bernhard Kirchen
f634f58788 Fix: DPL: use correct channel type to get inverter efficiency 2024-04-11 08:28:49 +02:00
PhilJaro
165a9bc168
adjust VE.Direct MPPT yield resulotion (#859) 2024-04-09 20:31:05 +02:00
eu-gh
0ed09aeb4c Feature: Huawei: add SoC stop threshold and verbose logging switch 2024-04-07 17:16:50 +02:00
SW-Nico
b9ad1e3054 VE.Direct: process more values and refactor variable names
* process "IL", "AR" and "MON"
* discard "BMV" and (unsolicited) History Data
* simplify isDataValid()
* veMpptStruct, veStruct: new, verbose variable names, including units,
  and replace floats (save values with original integer precision)
* comment on rollover situation in isDataValid()
2024-04-07 17:13:07 +02:00
Thomas Basler
ea28903761 Move parsing of serial from web request to separate method 2024-04-05 19:14:56 +02:00
Thomas Basler
980e847ccb Feature: Check for out of memory situations when sending json responses
Also shows a nice message in the frontend if an internal error occours
2024-04-05 19:14:56 +02:00
Thomas Basler
2e3125fe8d Feature: Migrated ArduinoJson 6 to 7 2024-04-05 19:14:56 +02:00
Bernhard Kirchen
3934906001
Merge pull request #836 from helgeerbe/merge-v24.3.31
Merges v24.3.31 from upstream
2024-04-03 20:08:09 +02:00
Thomas Basler
b55ca53d1d Fix: Setting DTU options was only possible once without reboot
Fix #1884
2024-04-03 18:35:27 +02:00
Bernhard Kirchen
21cdc69625 Feature: use VE.Direct "network total DC power"
1. makes the DPL use the power generated by all connected charge
   controllers for calculations based on solar passthrough.
2. makes the network total DC power appear as "MPPT Total Power" in the
   live view at the top.
3. shows the network total DC power in the VE.Direct live data card.
2024-04-03 16:33:15 +02:00
Bernhard Kirchen
6b8c93d2e6 polish VE.Direct HEX support
* show charge controller temperature in live view
* send hex requests right after decoding a frame. this seems to have the
  best chance of getting an answer to all requests.
* deem 0xFFFFFFFF value of network total DC power as invalid indicator.
  neither network state, nor network info, nor network mode seem to
  indicate that the charge controller is part of a VE.Smart network. for
  that reason, we revert to always querying the network total DC power
  value, but testing it for max(uin32_t) value, which seems to indicate
  that the charge controller is not part of a VE.Smart network.
* improve (verbose) logging, e.g., use _logId, and print names of
  response codes and known registers, always print error messages,
  add additional tests to prevent overly verbose messages.
* move hex protocol definitions to VeDirectData.h header
  and use enum classes
* define register addresses in enum class
* move values retrieved through hex protocol into main MPPT data struct
* do not send HEX requests if the serial interface cannot send data
* detect whether smart battery sense temperature is available
* web app: make all VE.Direct sub-cards iterable. this makes addind more
  values much simpler and saves a bunch of code in the web app.
* make VeDirectFrameHandler state a type-safe enum class
* unindent MPPT controller loop()
* whitespace cleanup
2024-04-03 16:33:15 +02:00
helgeerbe
ff44267e73 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into merge-v24.3.31 2024-04-03 11:53:03 +02:00
Bernhard Kirchen
43f553d2d4 VE.Direct MQTT: simplify code
the use of a #define is warranted here since it saves a lot of code
duplication and improves code readability.
2024-04-02 21:05:59 +02:00
Bernhard Kirchen
92a7f27919 VE.Direct: use float rather than double
double precision floating point numbers are not needed to handle
VE.Direct values. handling double is implemented in software and hence
*much* more resource intensive.
2024-04-02 21:05:59 +02:00
Bernhard Kirchen
b299b9dc6c VE.Direct: simplify access to data
hand out const& to the data structs. this is possible now that this
struct is "stable", i.e., not reset regularly.
2024-04-02 21:05:59 +02:00
Bernhard Kirchen
ad125ea804 Fix: properly handle fragmented VE.Direct messages
queue every text event until the frame was checked by it checksum. then
process the data directly into the buffer struct. do not clear the
buffer struct, so it will always include the most recent value of a
particular data point.
2024-04-02 21:05:59 +02:00
MalteSchm
8abf614047 Feature: BMS initiated emergency charging
This change logically connects the AC-Charger with the BMS to add BMS
initiated emergency charging and respecting BMS current limits.
2024-04-02 21:05:00 +02:00
Thomas Basler
8add226a7c Save flash: Move WebApi json parsing to separate method to prevent a lot of redundant code 2024-04-01 13:52:09 +02:00
Thomas Basler
6f3b8fb8e1 Fix: Change default NTP server
Fixes #1877
2024-03-31 12:27:27 +02:00
Bernhard Kirchen
91a0992964 fix: VE.Direct MPPT data not always updated in websocket
set the "last published" timestampt after handling *all* MPPTs.
2024-03-26 20:48:39 +01:00
David von Oheimb
811b64adb5 PowerLimiter.cpp: simplification and minor correction of logic table comments 2024-03-25 10:55:00 +01:00
Bernhard Kirchen
12f7caf998 fix: HTTP power meter: retrieve multiple JSON paths
if only a single request was made (switch "Individual HTTP requests per
phase" is off), the user could still enable phase 2 and phase 3 config
and configure a respective JSON path. however, the value was never
extracted from the successful HTTP request for phase 1.

closes #637.
2024-03-23 22:13:59 +01:00
Bernhard Kirchen
b8d0998a49 HTTP power meter: refactor tryGetFloatValueForPhase
unindent code, prepare this method for re-use on the same HTTP response
but with a different JSON path.
2024-03-23 22:13:59 +01:00
Bernhard Kirchen
c41d6f5138 HTTP power meter: remove trailing whitespace
this commit is empty when inspecting it with --ignore-all-space.
2024-03-23 22:13:59 +01:00
Bernhard Kirchen
054a677575 DPL settings in web app: split metadata from config
users are manipulating the DPL using HTTP POST requests. often they are
requesting the current settings using HTTP GET on the respective route,
then change a particular settings, and send all the data back using HTTP
POST. if they failed to remove the metadata node from the JSON,
OpenDTU-OnBattery would not be able to process the JSON due to its size.
the web app does not submit the metadata.

to avoid problems, the metadata is now split from the configuration
data.
2024-03-23 22:13:50 +01:00
Bernhard Kirchen
8bfb5c6523 implement and use Utils::checkJsonOverflow()
this method calls the overflowed() method on the respective
DynamicJsonDocument and prints a respective message if not all
data could be added to the DynamicJsonDocument.
2024-03-23 17:57:13 +01:00
Bernhard Kirchen
1fb2d4262e do not publish live data for broken MPPT controllers
in case the user defines the respective pins, an MPPT controller will be
setup and the websocket would previously publish its invalid data even
if no data at all was received. this lead to using an invalid index and
to publish a useless card. instead, skip those controllers.

if the connection to a controller breaks, it will always present as a
card in the live view with the respective serial number and the last
known data.
2024-03-23 17:56:51 +01:00
Bernhard Kirchen
0154da91ab fix VE.Direct live data response size
PLLIMIT would not (always) be part of the JSON string transmitted to the
web application and trip it. with the help of the ArduinoJson assistant,
new values to use in the response size calculation were introduced.
also, importantly, a constant offset was added for the DPL status and
the JSON structure sourrounding the MPPTs.
2024-03-23 17:56:51 +01:00
Bernhard Kirchen
1c51c2de40 fix and harden BatteryStats update timestamp handling
* updating the SoC or value shall also update the general timestamp, as
  the latter is defined as "any value changed", which includes SoC and
  voltage, of course.
* if the last update is not a valid timestamp at all, the
  updateAvailable method must always return false, obviously.
2024-03-23 17:56:46 +01:00
Bernhard Kirchen
d935283d1f avoid sending null through live data websockets
on the "main" live data websocket this can happen if no
OnBattery-specific data is available to sent but the empty
JSON document is still sent, which trips the web application.

publishing null in the battery live data websocket also trips the web
application, which rightfully assumes a valid object if data is received
through the websocket.
2024-03-23 17:54:45 +01:00
Bernhard Kirchen
13e42051b6 DPL: improve verbose logging (more variables logged) 2024-03-22 21:50:42 +01:00
Snoopy-HSS
bbaed260f5
SMA Homemanager: fix power value calculation
when consuming from the grid, the power meter value shall be positive, and it shall be negative when exporting power.
2024-03-22 10:20:53 +01:00
Bernhard Kirchen
b449dd1196 replace VICTRON_MAX_COUNT
determine the amount of controllers actually in use dynamically,
especially to avoid indices which are invalid, causing an error
to be printed, even though the user did not do anything wrong.
2024-03-20 22:11:11 +01:00
Bernhard Kirchen
8e5e8d169d fix: VE.Direct live data after supporting second MPPT
an error was made when determining whether or not to push a VE.Direct
MPPT's state through the websocket based on its data's age.
2024-03-20 22:11:10 +01:00
helgeerbe
5259fc172a Merge remote-tracking branch 'tbnobody/OpenDTU/master' into v24.3.15 2024-03-20 09:42:35 +01:00
Bernhard Kirchen
cd339a3a14 Feature: implement PowerMeter pin config for serial interfaces
in your pin_mapping.json, add a powermeter object like this:

[
    {
        "name": "My Board",
        ...
        "powermeter": {
            "rx": <num>,
            "tx": <num>,
            "dere": <num>
        },
        ...
    }
]

the SML power meter requires the rx pin to be set. the SDM power meter
requires the rx and tx pins are set. the "dere" pin pin is optional and
if set, this pin controls the driver enable and receiver enable pins of
the RS485 transceiver. the SDM library handles this pin.

closes #771.
2024-03-19 21:27:25 +01:00
PhilJaro
4f0385285c add new Victron SmartShunt values to liveView and MQTT (HASS) 2024-03-17 21:00:32 +01:00
Bernhard Kirchen
45c7243937 polish SMA HomeManager integration
* remove/comment unused variables to avoid compiler warnings

* cleanups: fix indention and style, make variable private, implement
  getters in header and make const.

* optimize message output: respect verbose logging setting. prefix
  output with SMA_HM.

* use newly introduced mutex in PowerMeterClass also for SMA HomeManager

* refactor code for readibility, unindent where possible.
2024-03-17 20:20:29 +01:00
Snoopy-HSS
f6680bd664 Feature: Support SMA HomeManager 2.0 as PowerMeter 2024-03-17 20:20:29 +01:00
Bernhard Kirchen
900326742c fix: prevent getTotalPower() reading intermediate results
the SDM power meter (among others) writes the power consumption of three
phases in multiple steps. this change helps to prevent getTotalPower()
reading intermediate values, e.g., reading a new value for phase 1 but
old values for phase 2 and 3 since phase 2 is currently read.

cache the values, and write them all at once, protected by a mutex,
later.

closes #732.
2024-03-17 16:54:48 +01:00
Bernhard Kirchen
13bc943dd5 Feature: Refactor/Simplify DPL settings
this changeset refactors the web application's DPL settings view. the
DPL settings can be complex, and they shall be presented in a way that
allows users to comprehend their meaning. irrelevant settings are now
hidden or displayed dynamically based on the influencing settings.

* group SoC thresholds into their own card

* hide battery SoC thresholds if battery disabled. if the user did not
  even enable the battery interface, battery SoC values will not be used
  for DPL decisions. in that case we completely hide the respective
  settings from the DPL admin view. this reduces the amount of settings
  for new users and especially users who don't even have a battery in
  their setup or have no BMS connected.

* group voltage thresholds and improve label texts

* fix load correction factor unit

* fix header (wording)

* group solar-passthrough settings in new card

* group inverter-related settings

* hide solar passthrough settings if VE.Direct is disabled. closes #662.

* completely disable form if any requirement is not met

* list available inverters by name and type. this makes it much more
  convenient to select the right inverter, especially since the order of
  the inverters in the web UI is decoupled from their position in the
  internal array, which was used to select them previously. care was
  taken that old configs select the same inverter after an update.
  when editing the DPL settings, the selects an inverter from the newly
  created drow-down list, and the respective old inverter is
  pre-selected.

* disable form if no inverter is configured (config alert)

* make inverter input selection dynamic. adjust selection to actual
  amount of channels for selected inverter. skip selection altogether if
  inverter has only one channel, or if it is solar powered.

* web app: wording adjustments

* group meta data into new property and exclude from submission. saves
  memory when evaluating the submitted settings.

* hide irrelevant settings if inverter is solar-powered

* move restart hour setting to inverter card. translate setting which
  disabled automatic restart.

* simplify "drain strategy" setting into an on/off toggle. care was
  taken that existing configs work the same after an upgrade. the
  respective drain strategy is translated into the new setting when
  reading the config. once the config is written, the new setting is
  persisted and the old is not part of the config any more.

* show more configuration hints, depending on actual configuration

* replace inputs by InputElement components where possible
2024-03-17 16:50:57 +01:00
Bernhard Kirchen
7d6b7252bf polish support for second VE.Direct MPPT charge controller
* fix compiler warning in SerialPortManager.cpp: function must not
  return void

* clean up and simplify implementation of usesHwPort2()
  * make const
  * overrides are final
  * default implementation returns false
  * implement in header, as the implementation is very simple

* rename PortManager to SerialPortManager. as "PortManager" is too
  generic, the static instance of the serial port manager is renamed to
  "SerialPortManager". the class is therefore renamed to
  SerialPortManagerClass, which is in line with other (static) classes
  withing OpenDTU(-OnBattery).

* implement separate data ages for MPPT charge controllers

* make sure MPPT data and live data time out

* do not use invalid data of MPPT controlers for calculations

* add :key binding to v-for iterating over MPPT instances
2024-03-17 16:50:15 +01:00
Arman Vartan
75541be248 Feature: Support for second Victron MPPT charge controller
this change adds support for a second Victron MPPT charge controller
using a second serial connection.

* Add device configuration for a second victron mppt
* Update VedirectView for second victron mppt
* Update MqttHandleVedirect for second victron mppt
* Update MqttHandleVedirectHass for second victron mppt
* Handle nonexisting victron controllers with optionals
* Add bool-function to Battery and inherited classes, if uart port 2 is
  being used
* Introduced a serial port manager. In order to prevent the battery and
  the Victron MPPT to use the same hw serial ports, this class keeps
  track of the used ports and their owners.
2024-03-17 16:50:15 +01:00
Bernhard Kirchen
21c19f4b7f fix: preserve SmartShunt energy values precision 2024-03-17 08:31:54 +01:00
Bernhard Kirchen
5c6b4a8f12 disable restarting solar-powered inverters
now that users can tell the DPL that their inverter is not powered by a
battery but powered by solar panels, we shall not restart inverters to
reset the daily yield value, if they are solar powered. these inverters
will reboot every night by themselves.
2024-03-14 21:37:47 +01:00
Bernhard Kirchen
8895791145 live data: exclude data if respective feature disabled 2024-03-14 21:37:47 +01:00
Thomas Basler
33bf2117c6 Fix: Set all settings to default when deleting an inverters
Previously some old settings from previous inverters could have been shown in a new inverter
2024-03-13 18:47:28 +01:00
Bernhard Kirchen
784e369482 optimize DPL thresholds MQTT integration
* fix logic in HomeAssistent handler
* also publish voltage thresholds (not just SoC thresholds)
* do not publish irrelevant thresholds to MQTT. if the inverter is
  solar-powered, no thresholds are effectively in use by the DPL and it
  therefore makes no sense to publish them to the broker. similarly, if
  no battery interface is enabled or the SoC values are set to be
  ignored, the SoC thresholds are effectively not in use and will not be
  published to the broker.
* make HA auto-discovery expire. this makes auto-dicovered items
  disappear from Home Assistent if their value is no longer updated.
  changes to settings which cause other thresholds to be relevant will
  then be reflected in Home Assistent even if some thresholds are no
  longer maintaned in MQTT.
* force HA update when related settings change enabling VE.Direct shall
  trigger an update since solar passthrough thresholds become relevant.
  similarly, enabling the battery interface makes SoC thresholds become
  relevant. there are more settings in the power limiter that also
  influence the auto-discoverable items.
* break very long lines
2024-03-10 22:10:02 +01:00
LukasK13
fba5c02346 Feature: Set powerlimiter thresholds via MQTT
publish DPL thresholds to MQTT, add support for setting powerlimiter
thresholds via MQTT, and make these auto-discoverable for Home
Assistent.
2024-03-10 22:10:02 +01:00
Bernhard Kirchen
803b30ca11 fix: wrong unit in battery HomeAssistent exp_aft
the exp_aft value is in seconds.
2024-03-10 21:20:56 +01:00
Bernhard Kirchen
19859ed601
Merge pull request #733 from helgeerbe/dpl-make-shutdown-partially-optional
DPL: Explicit Support for solar-powered inverters
2024-03-10 17:25:30 +01:00
Bernhard Kirchen
c46980d6af fix: more memory for onBattery live data
the allocated memory to create the JSON with onBattery-specific totals
for the live view was too little to contain all values, which are sent
regularly.
2024-03-10 15:57:50 +01:00
Bernhard Kirchen
80edbec769 Feature: DPL: keep inverter running if solar powered
avoid shutting down the inverter at all if the calculated power limit
falls below the lower power limit or if the power meter value is
outdated. do this only if the inverter is setup to be solar powered.
2024-03-09 15:42:09 +01:00
Bernhard Kirchen
91f8f61e63 Feature: DPL: explicit support for solar powered inverters
by default and until this change, we assumed that the inverter
controlled by the DPL is powered by a battery. not all users have a
battery in their system. they still use the DPL to achieve net-zero
export. those users can now tell the DPL that their inverter is powered
by solar modules rather than a battery and the DPL will behave
accordingly.
2024-03-09 15:40:13 +01:00
Bernhard Kirchen
be15050aed DPL: refactor code determining battery charge cycle state 2024-03-09 15:40:13 +01:00
Bernhard Kirchen
c6f81806d6 DPL: make "IsInverterSolarPowered" configurable through web app 2024-03-09 15:40:13 +01:00
Bernhard Kirchen
b11b1dbcba DPL: define IsInverterSolarPowered config switch 2024-03-08 22:53:34 +01:00
Bernhard Kirchen
c42d68812c DPL limit scaling: prevent division by zero
this check was removed on error when moving the scaling code into its
own function.
2024-03-07 21:18:11 +01:00
Bernhard Kirchen
b0795a2131 DPL limit scaling: only for supported models 2024-03-07 21:18:09 +01:00
Bernhard Kirchen
64ad4bded1 fix: DPL: limit scaling sanity checks
do not scale limit if inverter is not producing, as DC channel power is
expected to be close to zero anyways.

do not scale limit if current inverter limit is small, such that
channels might produce very little power exactly because the limit is so
low.

move the calculation out of setNewPowerLimit and into a new function, so
that we can make use of return statements there.
2024-03-07 20:54:16 +01:00
Thomas Basler
f995287a6e Feature: Add support for HERF inverters 2024-03-06 21:57:18 +01:00
Bernhard Kirchen
50635ee2ce Feature: live view: update with respective frequency
the update frequency of Victron MPPT charger data, the battery Soc, the
huawei charger power, and the power meter differ from one another, and
differ in particular from the inverter update frequency.

the OnBattery-specific data is now handled in a new method, outside the
upstream code, which merely call the new function(s). the new function
will update the websocket independently from inverter updates. also, it
adds the respective data if it actually changed since it was last
updated through the websocket.

for the webapp to be able to recover in case of errors, all values are
also written to the websocket with a fixed interval of 10 seconds.
2024-03-05 11:31:44 +01:00
Bernhard Kirchen
e432f0eca3 make BateryStats::updateAvailable wrap-around-safe 2024-03-05 11:31:44 +01:00
Bernhard Kirchen
8b6e57cda7 Fix: DPL: ensure inverter reaches requested state
we previously only called commitPowerLimit() if the desired limit
changed such that the change was bigger than the hysteresis. we found
that if the limit update was not received and the desired limit would
not change much, the limit of the inverter was wrong for a long time.

to mitigate this, we introduced re-sending the limit update every 60
seconds, regardless of what the limit reported by the inverter was at
that time.

if the power-up command was not received, we also would repeat it only
once every 60 seconds.

this leads to a new kind of staleness and the actual inverter state was
still not matching the desired state.

this new approach effectively adds an additional control loop at the
start of the DPL loop(). that new function compares the requested
inverter state to the actual reported state. it sends updates (limit
update or power on state) until the desired inverter state is reached,
or until a (hard-coded) timeout occurs.

this approach also allows us to send power-up, power-down, and limit
update commands independent from one another and in a particular order.

this should make sure that the inverter is in the desired state even if
conditions change slowly and commands were not received as expected.
2024-03-02 23:39:43 +01:00
Thomas Basler
50abcd1061 Fix: Prevent hiding text on display if it's too long
Fixes: #1797
2024-03-01 19:30:24 +01:00
helgeerbe
c72ae561c7 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2024-02-19 16:03:56 +01:00
helgeerbe
1eb75c322d
Merge pull request #679 from schlimmchen/dpl-voltage-features
DPL Voltage Features
2024-02-19 13:48:12 +01:00
Bernhard Kirchen
9240663552
Feature: show power grid usage on display (#658)
* make efficient use of available display area

fix calculation of the text baselines, using getAscent() in favor of
getMaxCharHeight(), which includes ascent and descent. this moves the
first text up and allows to insert margin between the lines until the
display area is fully utilized.

on large displays, if the small diagram is selected, keep the first line
rather low to avoid collision with the diagram y-axis label. in this mode,
there is still more space between the text lines as before, allowing for
improved readability.

* Feature: show power grid usage on display

if the power meter is enabled, the display will use two of three out
of every three-second time slot to show the grid consumption.

closes #620.
2024-02-19 13:38:57 +01:00
Bernhard Kirchen
c930018764 Feature: DPL: use best available voltage value
the DPL is interested in the battery's voltage to make decisions about
draining the battery or letting it charge (if the user opts to use
voltage thresholds rather than SoC thresholds). using the DC input
voltage reported by the inverter under control has disadvantages:

* the data might be quite old due to the communication protocol
  implementation. more inverters being polled means even more lag. the
  connection being wireless makes this even worse, due to the need
  to retry the occasional lost packet, etc.
* the data is not very accurate, since the DC input of the inverter is
  actually some cabling and a couple of junctions away from the actual
  battery. this voltage drop can mostly only be estimated and is worse
  with higher load. the load correction factor is there to mitigate
  this, but it has its own problems and is cumbersome to calibrate.

instead, this change aims to use more accurate battery voltage readings,
if possible. the DPL now prefers the voltage as reported by the BMS,
since it is for sure the closest to the battery of all measuring points
and measures its voltage accurately regardless of the load (the voltage
reading will still drop with higher loads, but this will be only due to
the battery's internal resistance, not that of cabling or junctions). if
no BMS voltage reading is available, the DPL will instead use the charge
controller's voltage reading, as it is available with much higher
frequency and is assumed to be more accurate as it offers a resolution
of 10mV. only if none of these two sources can be used, the inverter DC
input voltage is assumed as the battery voltage.

closes #655.
2024-02-18 22:17:15 +01:00
Bernhard Kirchen
6df358242c Feature: know and use SoC precision
the Victron SmartShunt communicates the SoC value in permille. this
should be displayed in the web UI accordingly. this is a good excuse to
fully move ownership of the SoC value to the BatteryStats base class and
add a precision indicator variable. this is required to be set each time
a derived class (a battery provider) wants to update the SoC value. the
precision is then used when populating the JSON data for the web UI
(live view).

related to #573.
2024-02-18 22:17:15 +01:00
Bernhard Kirchen
7c069b1cc4 replace BatteryStats::isValid() method
in the respective context, the DPL only needs to be sure that the SoC
value is not outdated. it should not even care about other values
reported by the battery interface. hence, the isValid() method shall be
concerned with the SoC value timestamp only. the method is renamed for
clarity.
2024-02-18 22:17:15 +01:00
Bernhard Kirchen
3595725f8a Feature: implement subscription to battery voltage MQTT topic
this extends the MqttBattery implementation by an additional topic which
allows to subscribe to receive battery voltage readings through the MQTT
broker. similar to the battery SoC topic, this allows to import a
critical battery data point for the DPL, in case the user chooses to use
voltage thresholds rather than SoC thresholds to control the DPL. if an
otherwise incompatible BMS is available which publishes the battery pack
voltage through MQTT, this can now be used to feed accurate voltage
readings to the DPL.
2024-02-18 22:17:15 +01:00
Bernhard Kirchen
30bfffb848 BatteryStats: manage battery pack voltage in base class
the BatteryStats base class shall be able to tell the total battery pack
voltage. for that reason, and to avoid code duplication, the voltage is
now handled in the base class and treated as a datum that is common to
all battery providers.
2024-02-18 21:49:12 +01:00
Bernhard Kirchen
921302bf73 Feature: DPL: add switch allowing to ignore SoC
unfortunately, the battery SoC values reported by battery BMSs are
unreliable, at least for some users, or at least without regular
(manual) full charge cycles to calibrate the BMS. it offers great
advantages to connect OpenDTU-OnBattery to a BMS (MQTT publishing of
values, Home Assistent integration, etc.), but previously the users
were then forced to configure the DPL by SoC values.

this change allows to configure the DPL such that SoC values are
ignored. instead, the voltage limits are used to make DPL decisions, as
if no SoC was available in the first place.

the SoC related setting are hidden from the DPL settings view if SoC
values are configured to be ignored.

closes #654.
2024-02-18 21:46:42 +01:00
Thomas Basler
d26333dd76 Apply automatic code formatting 2024-02-10 23:37:44 +01:00
Thomas Basler
1d2055cc89 Merge branch 'pr1732' into dev 2024-02-10 23:37:09 +01:00
Thomas Basler
1973cb986c Merge branch 'pr1731' into dev 2024-02-10 23:37:03 +01:00
Thomas Basler
d635a9babd Merge branch 'pr1729' into dev 2024-02-10 23:36:47 +01:00
Bernhard Kirchen
6036d8efea implement oscillating screensaver
this implementation avoids the display content jumping the full
screensaver offset from right to left when the modulo operator
wraps. this change makes the display content walk from right to
left as it did walk from left to right.
2024-02-10 18:41:47 +01:00
Bernhard Kirchen
5f51c80022 Fix: make text of total production fit displays
in case the total production is larger than 1 MWh, i.e., 1000 kWh, the
text on the respective line becomes too large such that it reaches out
of the display when the screensaver is enabled.

this happens on the small and large displays.

this change switches the number format to a float without decimal places
if the total production is larger or equal to 1000 kWh. this saves a dot
and a digit, making the text short enough to fit the display even when
the screensaver moved the display contents as far to the right as it
does.
2024-02-10 17:38:32 +01:00
Bernhard Kirchen
25a66a1722 make efficient use of available display area
fix calculation of the text baselines, using getAscent() in favor of
getMaxCharHeight(), which includes ascent and descent. this moves the
first text up and allows to insert margin between the lines until the
display area is fully utilized.

on large displays, if the small diagram is selected, keep the first line
rather low to avoid collision with the diagram y-axis label. in this mode,
there is still more space between the text lines as before, allowing for
improved readability.
2024-02-10 13:33:51 +01:00
helgeerbe
b794f46ef0 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2024-02-09 20:14:58 +01:00
Bernhard Kirchen
1865113842 Feature: JK BMS Home Assistent integration
* pylontech HA integration: remove unused method/variable

* make MqttHandlePylontechHassClass::publishConfig() private.
  there are no outside users of that method.

* rename to MqttHandleBatteryHass

* battery HA integration: merge methods and bring back forceUpdate().
  even though the forceUpdate() method was not in use before, it makes
  sense to implement it and use it when the battery config changes.
  rather than controlling a separate flag, it now changes the _doPublish
  flag of the class, which also triggers publishing the device config to
  Home Assistant when an MQTT connection problem was detected. since
  both situations are now handled similarly, we can merge the loop() and
  publishConfig() methods.

* battery: provider specific sensors for HA

* move Battery MQTT loop to BatteryStats
  the BatteryStats class should handle the MQTT publishing, including the
  interval. for the calculation of a reasonable Home Assistent expiration
  value this class now also knows the maximum publish interval.

* JK BMS: fix publishing values for Home Assistent
  Home Assistent values expire, because we set them to expire after three
  MQTT publish durations. for that reason, we need to re-publish all
  values after our self-inflicted full publish interval.

* define JK BMS sensors for Home Assistent

closes #482.
2024-02-05 21:22:07 +01:00
Bernhard Kirchen
c2b49931be Fix: must call Pylontech Home Assistent init() method
previously, the Pytlontech Home Assistent class implementation had an
init() method, that was never called, as it did nothing. the class
relied on its loop() method being called from the main loop(). after
switching to the TaskScheduler approach, the Pylontech Home Assistent
class init() method was adjusted to register a task that calls the
loop() method periodically. however, the init() method was still not
called.
2024-02-05 20:54:34 +01:00
Thomas Basler
7e2064e264 Feature: Added support for boards with 16MB flash and PSRAM 2024-02-02 20:33:42 +01:00
Thomas Basler
1b637f0870 BREAKING CHANGE: Web API Endpoint /api/livedata/status and /api/prometheus/metrics
Yield total and Yield day where moved from the AC section to the INV section
2024-01-30 22:29:25 +01:00
Thomas Basler
e1564780d6 BREAKING CHANGE: Web API Endpoint /api/livedata/status and /api/prometheus/metrics
Power DC was moved from the AC section to the INV section
2024-01-30 22:29:25 +01:00
Thomas Basler
c27ecc3620 BREAKING CHANGE: Web API Endpoint /api/livedata/status
To reduce the heap usage it is necessary to send the inverters one by one instead of a huge response. A simple call to `/api/livedata/status` returns just some very general information. If detailed inverter information are required the inverter serial number has to appended `?inv=<serial number>`.
The websocket also returns only one inverter at a time. It as to be assembled at client side.
2024-01-30 22:29:25 +01:00
Thomas Basler
557c5d645e Remove all files but the pin_mapping.json from filesystem on factory reset
This allows to create more user defined files and get them deleted on factory reset.
2024-01-30 22:29:12 +01:00
Thomas Basler
48a722f826 Merge branch 'pr1642' into dev 2024-01-30 20:47:45 +01:00
Thomas Basler
a848275bb9 Merge branch 'pr1706' into dev 2024-01-30 19:34:19 +01:00
Sabouflage
5d7512e026 fix(mqtt): setting MQTT LWT online message for frontend 2024-01-30 19:03:23 +01:00
Sabouflage
dfed23261a fix(mqtt): MQTTs LWT QoS config used also for TLS connections 2024-01-30 19:02:57 +01:00
Stefan Oberhumer
e752c433af Use http header ETag caching for all static content.
Using the md5sum as ETag http header value should enable caching on all static http content.
2024-01-30 00:35:23 +01:00
Thomas Basler
2716f4c5df Removed not required pointer to AsyncServer instance 2024-01-27 01:09:55 +01:00
Thomas Basler
f0061b976d Merge branch 'pr1676' into dev 2024-01-26 16:48:15 +01:00
Thomas Basler
4e669d8932 Feature: Add support for ST7567 GM12864I-59N Display 2024-01-26 16:05:56 +01:00
helgeerbe
1916d6d6a8 check twice a second for new vedirect data on live viw 2024-01-26 14:32:44 +01:00
helgeerbe
ebacc2f25f Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2024-01-25 23:36:32 +01:00
Stefan Oberhumer
7aece2e143 Call SunPosition.isDayPeriod() once 2024-01-23 09:42:13 +01:00
Thomas Basler
4f2fbaaf2a Remove unused function parameter 2024-01-20 23:12:59 +01:00
Thomas Basler
16fbad92ac simplify calculations in WebApi_ws_Live 2024-01-20 11:38:52 +01:00
Thomas Basler
7bc1a17fac Move task initialization from init method to constructor
This saves flash
2024-01-20 11:24:57 +01:00
Thomas Basler
251d197fb6 Migrate WebApi loop() methods to scheduler tasks 2024-01-20 02:00:22 +01:00
Thomas Basler
e66060e769 Move the conversation from time_t to String into DevInfoParser 2024-01-20 01:09:42 +01:00
Thomas Basler
dcc157261e Don't perform redundant conversions 2024-01-20 00:32:13 +01:00
helgeerbe
f305b40be0 Merge pull request #612 from Fribur:development
- fix to HttpPowermeter not using explicitly specified non standard ports
- Revert back to using FirebaseJson instead of ArduinoJson
2024-01-17 13:26:52 +01:00
helgeerbe
63205f88be Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2024-01-16 17:39:45 +01:00
Thomas Basler
c20caf8097 Feature: Support HMS/HMT inverters in different countries with different frequency bands
Thanks to @Fribur, @homeautomation2022 and @stefan123t
2024-01-14 16:37:34 +01:00
Thomas Basler
2c92750100 webapp: Remove hard coded min/max frequencies for CMT module 2024-01-13 12:51:20 +01:00
Thomas Basler
ee78698e37 Migrate all frequency calculations to Hz
Previously the code contains calculations  using a mixture  of kHz and Hz.

Thanks to @Fribur
2024-01-13 12:51:20 +01:00
Thomas Basler
638f52a8da Feature: Add current limit to prometheus output
Fixes #1617
2024-01-13 11:33:58 +01:00
Thomas Basler
f013698471 Feature: Added fullscreen diagram to display 2024-01-13 11:31:12 +01:00
Fribur
e136e096f4
Merge branch 'development' into development 2024-01-08 11:00:59 -05:00
Thomas Basler
637d4f06a3 Feature: Added option to disable the diagram at the display 2024-01-08 14:19:26 +01:00
Bernhard Kirchen
a012d81427
avoid too frequent SmartShunt data copies (#596)
currently the whole SmartShunt data structure is copied to the
BatteryStats instance in every loop, even though the data cannot
possibly have changed. this is quite an expensive task to do in every
loop. this change tracks the last update timestamp and only does the
copy operation if an actual updated data structure was received from
the smart shunt.
2024-01-07 18:30:02 +01:00
helgeerbe
dd5d5ce9fd Prevent empty HASS auto discovery topics if memory allocation fails (onBattery) 2024-01-07 10:31:06 +01:00
helgeerbe
d0e1da7b1d Prevent config corruption by checking whether memory allocation was successfull. (onBattery) 2024-01-07 10:30:12 +01:00
helgeerbe
d6d274f078 Prevent empty HASS auto discovery topics if memory allocation fails (onBattery) 2024-01-06 22:51:35 +01:00
helgeerbe
ec93004724 Better handling of out of memory situations in live data websocket (onBattery) 2024-01-06 22:42:34 +01:00
helgeerbe
210fce67ce Use auto keyword and references more often (onBattery) 2024-01-06 22:10:07 +01:00
Bernhard Kirchen
2608080708 Feature: add heap details to system info and prometheus (#595)
this change adds the values of ESP.gteMaxAllocHeap() and
ESP.getMinFreeHead() to the prometheus metrics and the system
information object. the web UI uses these values to diplay the size of
the largest free contiguous block, calculate a rough estimate for the
level of fragmentation, and the maximum usage of heap memory since boot
in absolute and relative amounts.
2024-01-06 20:12:35 +01:00
Fribur
92de3e9f87 fixed a bug where under one condition DNS was not tried for resolving host IP 2024-01-05 20:54:53 -05:00
helgeerbe
d5155a07be Remove F macro from onBattery extensions 2024-01-05 23:02:26 +01:00
Thomas Basler
6573c51052 Use auto keyword and references more often 2024-01-05 22:04:54 +01:00
Thomas Basler
24c8a40fad Use Utils::checkJsonAlloc in ConfigurationClass 2024-01-05 21:56:34 +01:00
Thomas Basler
f968179b60 Better handling of out of memory situations in live data websocket 2024-01-05 21:56:34 +01:00
Thomas Basler
f00cd1bd61 Prevent empty HASS auto discovery topics if memory allocation fails 2024-01-05 21:55:15 +01:00
Thomas Basler
88d75673fc Prevent config corruption by checking whether memory allocation was successfull. 2024-01-05 21:55:15 +01:00
Thomas Basler
a65f1e48a5 Fix: Access Point not working after firmware update
Fixes #1613
2024-01-05 21:55:15 +01:00
Thomas Basler
2a15677923 Fix: Optimize network connection handling
This should provide a more reliable connection to several AP types. See #576
2024-01-05 21:55:15 +01:00
Bernhard Kirchen
377406f10c
Feature: add heap details to system info and prometheus (#595)
this change adds the values of ESP.gteMaxAllocHeap() and
ESP.getMinFreeHead() to the prometheus metrics and the system
information object. the web UI uses these values to diplay the size of
the largest free contiguous block, calculate a rough estimate for the
level of fragmentation, and the maximum usage of heap memory since boot
in absolute and relative amounts.
2024-01-05 21:46:31 +01:00
Fribur
e09ffcbb53 shorter parameter names 2024-01-05 14:39:32 -05:00
Fribur
85d0f2a8fb HttpPowerMeterClass: change order of resolving hostname
OpenDTU console gets spammed with "WifiGeneric::hostByName() error when first trying to resolve the hostname via DNS. So reverse order: first try mDNS, if that fails try DNS. Also ensure that https bool is passed correctly to HTTPClient::begin(). Lastly, concatenate strings for building Digest authorization using "+" and not via snprintf.
2024-01-05 14:36:19 -05:00