* fix compiler warning in SerialPortManager.cpp: function must not
return void
* clean up and simplify implementation of usesHwPort2()
* make const
* overrides are final
* default implementation returns false
* implement in header, as the implementation is very simple
* rename PortManager to SerialPortManager. as "PortManager" is too
generic, the static instance of the serial port manager is renamed to
"SerialPortManager". the class is therefore renamed to
SerialPortManagerClass, which is in line with other (static) classes
withing OpenDTU(-OnBattery).
* implement separate data ages for MPPT charge controllers
* make sure MPPT data and live data time out
* do not use invalid data of MPPT controlers for calculations
* add :key binding to v-for iterating over MPPT instances
this change adds support for a second Victron MPPT charge controller
using a second serial connection.
* Add device configuration for a second victron mppt
* Update VedirectView for second victron mppt
* Update MqttHandleVedirect for second victron mppt
* Update MqttHandleVedirectHass for second victron mppt
* Handle nonexisting victron controllers with optionals
* Add bool-function to Battery and inherited classes, if uart port 2 is
being used
* Introduced a serial port manager. In order to prevent the battery and
the Victron MPPT to use the same hw serial ports, this class keeps
track of the used ports and their owners.
this change utilizes some of the features from library "frozen", which
was included upstream for the grid profile parser. to improve code
maintainability, a couple of std::maps mapping strings to values or the
other way around were introduced in OpenDTU-OnBattery-specific code at
the expense of some flash and computing overhead.
library "frozen" offers constexpr versions of map and string, which
saves initialization code and offers slightly faster lookups. this
brings the binary size down by ~25kB and should provide a small
performance improvement at runtime.
* Optimize Sun data calculation
* Remove not required enum
* Split config struct into different sub structs
* Feature: Allow configuration of LWT QoS
* Made resetreason methods static
* Feature: Implement offset cache for "YieldDay"
Thanks to @broth-itk for the idea!
Fix: #1258#1397
* Add Esp32-Stick-PoE-A
* remove broken LilyGO_T_ETH_POE config, use device profile instead
* Feature: High resolution Icon and PWA (Progressive Web App) functionality
Fix: #1289
* webapp: Update dependencies
* Initialize TaskScheduler
* Migrate SunPosition to TaskScheduler
* Migrate Datastore to TaskScheduler
* Migrate MqttHandleInverterTotal to TaskSchedule
* Migrate MqttHandleHass to TaskScheduler
* Migrate MqttHandleDtu to TaskScheduler
* Migrate MqttHandleInverter to TaskScheduler
* Migrate LedSingle to TaskScheduler
* Migrate NetworkSettings to TaskScheduler
* Migrate InverterSettings to TaskScheduler
* Migrate MessageOutput to TaskScheduler
* Migrate Display_Graphic to TaskScheduler
* Migrate WebApi to TaskScheduler
* Split InverterSettings into multiple tasks
* Calculate SunPosition only every 5 seconds
* Split LedSingle into multiple tasks
* Upgrade espMqttClient from 1.4.5 to 1.5.0
* Doc: Correct amount of MPP-Tracker
* Added HMT-1600-4T and HMT-1800-4T to DevInfoParser
Fix#1524
* Adjusted inverter names for HMS-1600/1800/2000-4T
* Add channel count to description of detected inverter type (DevInfoParser)
* Adjust device web api endpoint for dynamic led count
* Feature: Added ability to change the brightness of the LEDs
Based on the idea of @moritzlerch with several modifications like pwmTable and structure
* webapp: Update dependencies
* Update olikraus/U8g2 from 2.35.7 to 2.35.8
* Remove not required onWebsocketEvent
* Remove code nesting
* Introduce several const statements
* Remove not required AsyncEventSource
* Doc: Added byte specification to each command
* Feature: Added basic Grid Profile parser which shows the used profile and version
Other values are still outstanding.
* Optimize AlarmLogParser to save memory
* Add libfrozen to project to create constexpr maps
* Feature: First version of GridProfile Parser which shows all values contained in the profile.
* webapp: Update dependencies
* Apply better variable names
* Remove not required casts
* Add additional compiler flags to prevent errors
* Add const statement to several variables
* Replace NULL by nullptr
* Update bblanchon/ArduinoJson from 6.21.3 to 6.21.4
* Add const keyword to method parameters
* Add const keyword to methods
* Use references instead of pointers whenver possible
* Adjust member variable names in MqttSettings
* Adjust member variable names in NetworkSettings
* webapp: Update timezone database to latest version
* webapp: Beautify and unify form footers
* Feature: Allow setting of an inverter limit of 0% and 0W
Thanks to @madmartin in #1270
* Feature: Allow links in device profiles
These links will be shown on the hardware settings page.
* Doc: Added hint regarding HMS-xxxx-xT-NA inverters
* Feature: Added DeviceProfile for CASmo-DTU
Based on #1565
* Upgrade actions/upload-artifact from v3 to v4
* Upgrade actions/download-artifact from v3 to v4
* webapp: add app.js.gz
* Gridprofileparser: Added latest known values
Thanks to @stefan123t and @noone2k
* webapp: Fix lint errors
* Feature: Add DTU to Home Assistant Auto Discovery
This is based on PR 1365 from @CFenner with several fixes and optimizations
* Fix: Remove debug output as it floods the console
* Fix: Gridprofileparser: Add additional error handling if profile is unknown
* webapp: add app.js.gz
* Fix: Offset cache for "YieldDay" did not work correctly
* webapp: update dependencies
* webapp: add app.js.gz
* Fix: yarn.lock was outdated
* Fix: yarn build error
* Fix: Reset Yield day correction in combination with Zero Yield Day on Midnight lead to wrong values.
* Fix: Allow negative values in GridProfileParser
* Correct variable name
* Fix#1579: Static IP in Ethernet mode did not work correctly
* Feature: Added diagram to display
This is based on the idea of @Henrik-Ingenieur and was discussed in #1504
* webapp: update dependencies
* webapp: add app.js.gz
---------
Co-authored-by: Thomas Basler <thomas@familie-basler.net>
Co-authored-by: Pierre Kancir <pierre.kancir.emn@gmail.com>
* introduce VictronMpptClass
this solves a design issue where the loop() method of a static instance
of VeDirectMpptController, which is part of library code, is called as
part of the main loop() implementation. that is a problem because the
call to this loop() must be handled differently from all other calls:
the lib does not know whether or not the feature is enabled at all.
also, the instance would not be initialized when enabling the feature
during normal operation. that would even lead to a nullptr exception
since the pointer to the serial implementation is still uninitialized.
this new intermediate class is implemented with the support for multiple
Victron charge controllers in mind. adding support for more charge
controllers should be more viable than ever.
fixes#481.
related to #397#129.
* VE.Direct: move get.*AsString methods to respective structs
those structs, which hold the data to be translated into strings, know
best how to translate them. this change also simplifies access to those
translation, as no parameter must be handed to the respective methods:
they now act upon the data of the instance they are called for. adds
constness to those methods.
* VE.Direct: simplify and clean up get.*AsString methods
use a map, which is much easier to maintain and which reads much easier.
move the strings to flash memory to save RAM.
* DPL: use VictronMpptClass::getPowerOutputWatts method
remove redundant calculation of output power from DPL. consider
separation of concern: VictronMpptClass will provide the total solar
output power. the DPL shall not concern itself about how that value is
calculated and it certainly should be unaware about how many MPPT charge
controllers there actually are.
* VE.Direct: avoid shadowing struct member "P"
P was part of the base struct for both MPPT and SmartShunt controller.
however, P was also part of the SmartShunt controller data struct,
shadowing the member in the base struct.
since P has slightly different meaning in MPPT versus SmartShunt, and
since P is calculated for MPPT controllers but read from SmartShunts, P
now lives in both derived structs, but not in the base struct.
* VE.Direct: isDataValid(): avoid copying data structs
pass a const reference to the base class implementation of isDataValid()
rather than a copy of the whole struct.
* VE.Direct: unify logging of text events
* VE.Direct: stop processing text event if handled by base
in case the base class processed a text event, do not try to match it
against values that are only valid in the derived class -- none will
match.
* VE.Direct MPPT: manage data in a shared_ptr
instead of handing out a reference to a struct which is part of a class
instance that may disappear, e.g., on a config change, we now manage the
lifetime of said data structure using a shared_ptr and hand out copies
of that shared_ptr. this makes sure that users have a valid copy of the
data as long as they hold the shared_ptr.
* VE.Direct MPPT: implement getDataAgeMillis()
this works even if millis() wraps around.
* VE.Direct: process frame end event only for valid frames
save a parameters, save a level of indention, save a function call for
invalid frames.
* Move Mppt logic to subclass
* Added Definitions for Shunts and restructering
* First integration of SmartShunt data into Web Interface
* Code cleanup
* VE.Direct: whitespace cleanup
* VE.Direct: manage HardwareSerial in unique_ptr
* VE.Direct: _efficiency is only needed by MPPT
* VE.Direct: keep as many members private as possible
* VE.Direct: use int8_t for pins (as before)
* VictronSmartShunt: _verboseLogging is not used
* VE.Direct: OR (off reason) is MPPT specific
it also applies to Phoenix inverters and Smart BuckBoost, but since
there is no support for those, the code is moved to the MPPT controller.
* Added Shunt alarms to liveview
Changed from double to int for several readings
* Update build.yml to allow manual builds
---------
Co-authored-by: Philipp Sandhaus <philipp.sandhaus@cewe.de>
Co-authored-by: Bernhard Kirchen <schlimmchen@posteo.net>
this avoids the debug buffer being overrun if verbose logging is
disabled in particular. that would happen because the buffer would
only be reset if verbose logging was enabled but filled in any case.
Due to side effects it is possible that the inverter receives the request but the DTU does not receive the answer. In this case the DTU would resend the request but the inverter would generate a event log entry (DTU command failed) because it received the message twice.