Author SHA1 Message Date
Bernhard Kirchen
d6163ddb7d
set default values for pin mappings if not provided (#275) 2023-06-26 11:57:29 +02:00
Bernhard Kirchen
07bb0b03f7
DPL hysteresis fix and refactor of setNewPowerLimit() (#264) 2023-06-26 11:52:33 +02:00
Bernhard Kirchen
9995c1172e
VE.Direct live view enhancements (#269)
* add calculated values to VE.Direct data

solar current, battery output power, and the charger's efficiency can be
calculated from the values reported by the charger. the efficiency must
be taken with a grain of salt. it seems that the solar power value and
the battery output voltage/current are not always in sync. for that
reason a moving average is used to smooth out the calculated efficiency
value.

* show calculated VE.Direct values in web live view

order the values and translations similarly for the input and output,
starting with power at the top, then voltage, then current as the last
of these three.

* VE.Direct live view: use 'd' as unit for days

'd' is the SI unit symbol for days and does not need translation, which
is desirable as units are not translated throughout the project.

* refactor VE.Direct live view

* move Dynamic Power Limiter data into its own type.
* split VE.Direct data into three types: "device", "input", and
  "output". hence all input and output values are now ValueObject, which
  allows to iterate over them using a loop without typing issues.
* generate the tables with input and output values using a loop, rather
  than defining each row individually.
* localize numbers using $n (vue method), which fixes switching the
  number format (dot vs. comma) when switching the language.
* use no decimal point for power values (they are integers), three
  decimal points for kWh values (charger only reports two decimal
  places, but three are easier to read since the unit is *kilo* Wh), one
  decimal point for the efficiency, and two for voltage and current.
* update language tokens to avoid mapping JSON keys to language keys
  (use the JSON keys to access the language tokens).
* re-structure language tokes so the brief keys took over from
  VeDirectFrameHandler always make sense (nest into "input" and
  "output").
* order values similarly from top to bottom: power, then voltage, then
  current. this is following the order of the inverters' details.
* group values by type/unit (yield and max. power) and order them
  "newest" to "oldest" from top to bottom.
* increase the DynamicJsonDocument as it was too small to hold the newly
  added data.

* update webapp_dist to include VE.Direct live view refactoring
2023-06-22 21:32:20 +02:00
Bernhard Kirchen
016e30ec00
DPL: fix efficiency calculation (#270)
there is no need to assume and hardcode a fixed efficiency for the
Victron solar charger. the charger reports the voltage and current at
its battery terminal, which can be used to calculate the charger's
actual power output.

the fallback to 100% for the efficiency of the Hoymiles inverter, in
case it is not producing power, is too optimistic. this commit proposes
to use 96.7% as the efficiency for that case, which is the peak
efficiency for many (all?) Hoymiles inverters as per datasheet. that
value should be closer to the real efficiency that will be achieved once
the inverter is turned on.
2023-06-22 21:30:33 +02:00
helgeerbe
cd1db49a98 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-06-22 21:14:12 +02:00
Thomas Basler
e8fee49dc8 Allow the non-existence of the HOYMILES_PIN_ defines 2023-06-21 19:59:35 +02:00
Thomas Basler
30fbd98274 Fix: Reboot loop occoured when no rf module was configured 2023-06-21 19:56:14 +02:00
helgeerbe
fd58ad2003 feat(add ability to do a polite power meter read): 2023-06-14 16:21:58 +02:00
helgeerbe
080a3eb29e Merge branch 'PM_onDemand' into development 2023-06-14 13:22:19 +02:00
helgeerbe
da7628dafc Fix: Respect minimum on demand poll rate for power meter 2023-06-14 13:21:50 +02:00
helgeerbe
ceb28030a4 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-06-14 13:02:00 +02:00
helgeerbe
ded5ceec58 Fix: Make power limiter intervall configurable
Allows to change the power limiter intervall settings in the config file.
2023-06-14 12:49:54 +02:00
helgeerbe
86ee7e1a64 perf(PowerMeter): query PowerMeter on demand
In addition to the cyclic query of the power meters, they will be queried on demand when total power is requested and last update is older than 1 second.
2023-06-14 11:25:54 +02:00
Dominic Michel
3562e85b5e Change metric type back to gauge 2023-06-13 20:59:24 +02:00
helgeerbe
8dac88e7b9 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-06-12 13:07:44 +02:00
helgeerbe
0fd7b75e83 Fix(Power Limiter): hysteresis is not repected properly 2023-06-12 13:06:31 +02:00
Thomas Basler
08f47c2f4c Fix: Prometheus syntax error with wifi_bssid
Fixes #1021
2023-06-11 20:04:23 +02:00
helgeerbe
e68baa3086 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-06-09 13:16:56 +02:00
MalteSchm
e0a8da84d7 full solar passthrough 2023-06-09 13:09:58 +02:00
Thomas Basler
88cb59d177 Feature: Publish BSSID via prometheus 2023-06-08 19:57:07 +02:00
Thomas Basler
b3e41c957b Feature: Publish BSSID via MQTT 2023-06-08 19:56:44 +02:00
Thomas Basler
91d3cd1da2 Feature: Show BSSID in the web interface 2023-06-08 19:56:22 +02:00
Thomas Basler
721f82a17c Added additional exception handler to also show unknown exceptions in live data api endpoint 2023-06-08 19:39:56 +02:00
Thomas Basler
3b6c529efb Fix: Do not publish leading blanks in MQTT payload
Fixes #1011
2023-06-07 17:58:31 +02:00
helgeerbe
8298a0c36f
Merge pull request #255 from madmartin:inverter_restart
Feature: add daily restart for the inverter
2023-06-05 10:10:14 +02:00
Martin Dummer
c727e21a49
Feature: add daily restart for the inverter
Add a configurable restart option for the inverter to set the "YieldDay"
values to zero.

Signed-off-by: Martin Dummer <martin.dummer@gmx.net>
2023-06-04 09:14:42 +02:00
helgeerbe
91ce844b36 fix(linter warining): use snprintf istead of strcopy 2023-06-02 13:12:42 +02:00
MalteSchm
e7c8a89bd3 inital version of full solar passthrough
Webinterface change to set full solar passthrough values

Adding webapi and config changes to enable full solar passthrough over certain battery Soc

inital version of full solar passthrough in power limiter

Passthrough mode can be enabled via MQTT

translations

re-enable comment

remove unused variable
2023-06-02 12:49:24 +02:00
Thomas Basler
7f267ff2fb Fix: Lint Error: Almost always, snprintf is better than strcpy 2023-06-01 23:30:13 +02:00
Thomas Basler
5a37948ca9 Fix: If no sunset/sunrise calculation is possible a wrong value is shown
This is catched now and a proper message is shown in the web UI. Also the mode is set to day.
2023-06-01 18:39:50 +02:00
Thomas Basler
24f063dd7b Fix: Prevent partly calculated total data in web ui and display
Leads to zeros where no zeros should be.
2023-05-30 22:10:27 +02:00
Thomas Basler
1c8bd8091b Feature: Allow reordering of the inverters in the live view
Reordering can be done in the inverter settings via drag&drop.
2023-05-29 20:17:07 +02:00
Thomas Basler
e7198073af Feature: Allow configuration of sunset type 2023-05-24 19:21:44 +02:00
Martin
52af52eb3a
Pylontech enhancement (#239) 2023-05-24 09:17:38 +02:00
helgeerbe
a3e7439181 fix(action): sort tags in chronological order 2023-05-24 09:13:04 +02:00
Thomas Basler
752362d2df Feature: Added localization setting to display
Its possible to change the language of the display
2023-05-23 18:25:12 +02:00
helgeerbe
8b64671151 doc: warning, that only 5 inverters are supported at max 2023-05-23 11:04:56 +02:00
helgeerbe
13b318690d fix: linting errors 2023-05-23 10:24:06 +02:00
helgeerbe
47f81f2579 breaking change: Reduce maximum number of invertes to 5 to keep livedata working
livedata json is now calculated as 4096 * MaxInvertes
2023-05-23 10:15:37 +02:00
helgeerbe
b7ac70b1ca Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-05-23 09:19:57 +02:00
Thomas Basler
40820c07f2 Use the new data store in the graphic display class.
With this patch, the display turns off if no inverter is reachable anymore. Previously it turned off if the production was zero.
This fixes #933
2023-05-21 22:40:32 +02:00
Thomas Basler
cd98941c5d Implement global data store to handle all invert total values
Use the new values in the LED, MQTT and Web interface.
2023-05-21 22:37:33 +02:00
helgeerbe
1c7b7d3cdf Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-05-10 18:16:25 +02:00
Thomas Basler
efcbd81927 Feature: Add used PIO environment to the system info page 2023-05-08 21:43:50 +02:00
MalteSchm
065c169b20
Set initial PL state in init() to avoid inverter shutdown on reboot... (#224) 2023-05-08 13:25:02 +02:00
helgeerbe
178d40d5b4 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-05-04 20:24:29 +02:00
Thomas Basler
65b728eebb Fix: No OpenDTU startup of CDC (like Pico or ESP32-S3) devices if no usb host is connected
Should also fix #826
2023-05-03 21:16:27 +02:00
MalteSchm
569edbe69e
static casts set last requested limit for all cases where inverter power is changed (#213) 2023-05-01 21:20:49 +02:00
helgeerbe
8021052cfd PL remove debug messages 2023-04-29 22:53:50 +02:00
helgeerbe
e5af5be70a remove comment 2023-04-29 21:53:05 +02:00