Commit Graph

1097 Commits

Author SHA1 Message Date
ranma
f42f018f3e
Fix: sanitize battery manufacturer name string (#1235)
If the string contains control characters for some reason, the browser
will reject the json with the error `bad control character in string
literal`.

This adds a setManufacturer function that validates the string is ASCII
and will cut off the string at the first non-ascii character.

Pylontech: `PYLON` (50 59 4C 4F 4E 20 20 20)
Pytes: `PYTES` (50 59 54 45 53)
Deye: `DY001` (44 59 30 30 31 03 E8 03)

See https://github.com/helgeerbe/OpenDTU-OnBattery/discussions/1226#discussioncomment-10566898
2024-09-09 21:46:47 +02:00
Thomas Basler
b52cd31309 Output WiFi disconnect reason in console 2024-09-02 20:16:03 +02:00
ranma
a87f9fa2cd
Fix: Allow higher-resolution SoC in live view header (#1197)
Commit accc70dea0 added the battery SoC to
the live view header. But due to getSoC() returning an int,
the precision was limited.

This changes getSoC() to return float so when a source with higher
precision is available, the respective precision is shown.
2024-09-02 11:08:21 +02:00
Bernhard Kirchen
9ebbc58930 Fix: Pylontech/Pytes CAN driver: user interrupts at level 2
we are running out of level 1 interrupts on ESP32-S3 boards. for that
reason, until this prooves to be another sort of problem, we allocate
the TWAI's interrupt for the battery CAN implementation at level 2.
2024-08-28 20:08:47 +02:00
Bernhard Kirchen
119bd3a41e Fix: Increase Huawei CAN task stack size
the stack size was already increased by Andreas Boehm in df53f34b51 in
the context of #1144 (SPI port manager). this change aligns the stack
size to a power of two and adds comments. the commit also serves to
place this change more prominently as a fix in the changelogs.
2024-08-28 15:13:23 +02:00
Bernhard Kirchen
1cbf18d4a7 Feature: HttpGetter: cache digest challenge
this allows us to add a valid Authorization header to each but the first
GET request, saving us from performing two GET requests every time we
want to perform the GET request. we still need a new client nonce and we
need to increase the nonce counter, so we also need to calculate a whole
new response, as we cannot just reuse the previous Authorization header
(that would be a replay attack).
2024-08-28 13:32:47 +02:00
Bernhard Kirchen
fd3b65f4bd Feature: HttpGetter: support MD5 digest authentication
the MD5 scheme should still be widely deployed, even though it is
deprecated. it is also still the default if not specific algorithm
is requested by the server.
2024-08-28 13:32:47 +02:00
Bernhard Kirchen
63612e9276 Fix: restart TCP connection if HTTP server sends Connection:close
we previously performed a whole new GET request when doing digest
authentication. it seemed beneficial to reuse the TCP connection to
perform the second GET request, which includes the authentication
tokens. however, if the server sends "Connection: close" we must not
requse the TCP connection for another HTTP request.

this broke authentication against Shelly devices (at least those with
original firmware).

now we explicitly set "Connection: keep-alive" in our request, and reuse
the TCP connection only if te server replies with "Connection:
keep-alive" as well.
2024-08-28 13:32:47 +02:00
Bernhard Kirchen
b5785d032e print SMA HomeManager timestamp as unsigned number 2024-08-24 21:26:35 +02:00
Bernhard Kirchen
2127b0b080 Fix: SMA HomeManager PowerMeter must announce new values
the SMA power meter implementation did not announce that it received a
new datum, such that the power meter data age was never reset. this made
the power meter values outdated and hence invalid, even though new
values were received and processed.
2024-08-24 21:12:25 +02:00
Bernhard Kirchen
821bc27562 Fix: VE.Direct data is invalid if no controller has valid data
the original implementation of the isDataValid() method worked by
returning false if any of the charge controllers had invalid data. if no
charge controllers were configured, this function then also needed to
also return false.

the logic was changed in 415c767d such that if at least one charge
controller had valid data, the function would return true. this would
have required to adjust the default return statement as well, but it was
not.

if the user enabled VE.Diret and configured at least one charge
controller in the pin mapping, but this controller never delivered any
data, the function would now errorneously return true, because the
container is not empty.

however, if no controller has valid data, this now means we exit the
loop and then the return value must be false, which is also desired if
the container is empty.
2024-08-24 21:06:44 +02:00
Andreas Böhm
65407dbdd6
fix: update mqtt subscriptions when topic changed (#1156)
* update mqtt subscriptions when topic was changed
* DPL/Huawei: manage MQTT subscriptions in map

---------

Co-authored-by: Bernhard Kirchen <schlimmchen@posteo.net>
2024-08-20 23:44:27 +02:00
Andreas Böhm
e7d454ff0b
Feature: support 'use battery at night' without VE.Direct
previously, we needed VE.Direct enabled to know the
solar charge controller output, which solely decided when
it was "nighttime". since this is now determined by the
wall clock, we can offer this feature to users without a
Victron charge controller connected using VE.Direct.
2024-08-19 20:49:37 +02:00
Andreas Böhm
df53f34b51
Feature: SPIPortManager allows simultaneous use of CMT2300 and Huawei charger
* backport SPIPortManager from @skippermeister
* adapt to support ESP32 and ESP32-S3 and ESP32-C3
* use logic to work with SPI numbering as in the official
  documentation: start with SPI0 and go up to SPI3
* increase Huawei CAN controller stack size to 2000
* increase startup delay for USB_CDC enabled builds to be able to
  catch bootlogs over USB
2024-08-19 20:44:59 +02:00
Bernhard Kirchen
2894d15477 remove obsolete #include 2024-08-16 21:38:16 +02:00
Bernhard Kirchen
5d1d071c8a
Fix: Improve DPL nighttime discharging (#1126)
* fix: DPL: start discharging at night logic error

the switch "always start discharging battery at night" would cause to
stop discharging the battery when there was solar power and the battery
was discharged below the start threshold.

this change introduces a nighttime discharging boolean variable, which
is enabled the instant we decide to start a battery discharge cycle due
to nighttime havin arrived. we reset this variable as soon as it is
daytime (solar power available). in that case, we allow discharging the
battery if the start threshold was reached. this can actually be the
case if the battery is charged with cheap electricity during the night.

removed comments as they merely spell out what the if statement already
expresses quite nicely.

* use SunPosition.isDayPeriod() to check for daytime

---------

Co-authored-by: Andreas Böhm <andreas@boehm.cx>
2024-08-15 20:10:32 +02:00
Andreas Böhm
599c5cea7d
adjustment: reduce precision of charged- and discharged energy for pytes batteries (#1165)
Precision is reduced to match the CAN protocol definition.
2024-08-13 17:51:12 +02:00
Andreas Böhm
df11db1244
fix: add auth check on battery, huawei and powermeter API endpoints (#1155) 2024-08-08 20:58:12 +02:00
Bernhard Kirchen
82b28e3732 Merge upstream tag 'v24.8.5' into development 2024-08-06 21:05:21 +02:00
Thomas Basler
cdaf10a92a Fix: Wifi reconnect issue introduced with #2117 and discussed in #2185 was fixed 2024-08-05 18:31:21 +02:00
Bernhard Kirchen
04513d3f22 webapp: disable OTA firmware dialog for unsupported devices
show a warning instead and cancel uploads with a HTPP 500 response.
2024-08-04 22:38:19 +02:00
Bernhard Kirchen
77af085ad3 Merge upstream tag 'v24.8.1' into development 2024-08-01 20:28:11 +02:00
Thomas Basler
03137e15dd Upgrade ESPAsyncWebServer from 2.10.8 to 3.1.2 2024-08-01 18:11:39 +02:00
Thomas Basler
70dacb5ea6 Merge branch 'pr2168' into dev 2024-08-01 17:53:53 +02:00
vaterlangen
cb5e7e59a5 Feature: add unit for MQTT battery voltage (#1143) 2024-07-31 15:05:41 +02:00
Bernhard Kirchen
1a19f881aa Feature: support JSON payload in MQTT battery provider
this changeset adds support for parsing the MQTT battery provider's SoC
and voltage topics' payloads as JSON to extract a numeric value at a
configurable path.
2024-07-31 15:05:41 +02:00
Andreas Böhm
accc70dea0
feature: show battery voltage, current, and power in live view (#1131)
* show battery voltage, current, and power in live view header (the "totals")
* show battery current and power in extra card
* use soc and current precision in live view
* BatteryStats: do not knowingly publish invalid data: not all battery
  providers know all values the base class manages. make sure to
  prevent publishing invalid values.

Co-authored-by: Bernhard Kirchen <schlimmchen@posteo.net>
2024-07-27 21:35:58 +02:00
Andreas Böhm
e95b70efeb
Feature: expose 'full solar passsthrough active' via MQTT (#1136) 2024-07-26 20:37:40 +02:00
Andreas Böhm
e3f9da75b9
BREAKING CHANGE: allow multiple OpenDTU-OnBattery instances at same HASS
This breaks existing HASS automation, as entity names and MQTT topics change!

* include dtu-unique-id in DPL MQTT HASS topics to allow multiple DTUs to be controlled
* fix filename "src/MqttHandlVedirectHass.cpp"
* refactor: use values from 'MqttHandleHass', add 'via_device' to all HASS devices
* set step size for power limiter voltage values
2024-07-23 21:27:14 +02:00
Bernhard Kirchen
6ee6eaf0b2
Fix: inverter power limits precision
Hoymiles inverters allow setting relative limits with a precision of 0.1 %.
this changeset allows to utilize this precision.

* preserve accuracy when decoding power limit
* Web API: process floating point limits
* MQTT: process floating point limits
* use appropriate accuracy for limits in web UI
* HASS: step for relative inverter limit is 0.1 %
2024-07-23 21:17:25 +02:00
Bernhard Kirchen
86a49a781a fix: use mutex when writing MQTT power meter value
we previously used the mutex to protect writing the target variable.
however, we would only do that for the old usecase, where a plain float
value in Watts was expected as the topic's payload.
2024-07-22 20:07:38 +02:00
Bernhard Kirchen
5e5a5253f4 fix: initialize MQTT power meter values to zero
avoid using uninitialized memory.
2024-07-22 20:07:38 +02:00
Niko
415c767d1d
Fix: Victron MPPT: be happy with at least one that delivers valid data (#1118) 2024-07-21 19:46:06 +02:00
Sven Sowa
5fee069c65
Remove double call to generateOnBatteryJsonResponse() (#1115)
the 2nd call was added in a merge operation in April
2024-07-21 17:59:57 +02:00
Bernhard Kirchen
926a0b992d improve error messages when probing JSON path value type 2024-07-15 17:41:30 +02:00
Bernhard Kirchen
9e7a0bca31 fix: handle numeric values disguised as strings in JSON
closes #1104.
2024-07-15 17:41:30 +02:00
Andreas Böhm
b90da210be
Fix: Improve overscaling for shaded inputs (#1089) 2024-07-11 15:03:12 +02:00
Bernhard Kirchen
d9d0141fde Merge upstream tag 'v24.6.29' into development 2024-07-10 21:45:43 +02:00
Bernhard Kirchen
e358513495
Merge PR #1077 from helgeerbe/powermeter-refactoring
this PowerMeter refactoring tackles many issues and prepares to solve many more.
2024-07-10 21:20:39 +02:00
Andreas Böhm
6a3f90ff95
Feature: add support for Pytes batteries using CAN (#1088)
Co-authored-by: Bernhard Kirchen <schlimmchen@posteo.net>
2024-07-10 21:01:49 +02:00
Bernhard Kirchen
b808e9ab18 HTTP+JSON power meter: value 1 is always enabled
enabling the HTTP+JSON power meter without enabling at least one value
makes no sense, so value 1 has always been treated as "always enabled".
while doing the power meter refactoring, however, a regression was
introduced that would hide the settings for value 1 in the web UI until
the power meter settings would be saved, which they cannot be due to
missing settings for value 1.
2024-07-01 22:07:55 +02:00
jstammi
1eab3ae773 Fix: explicitly disconnect prior connecting to wifi
to prevent from invalid association packets exchange
#618

(cherry picked from commit b6c320d481eb77b4f4e0407237917d2d897bfd9d)
2024-06-30 20:20:05 +02:00
Thomas Basler
4640ddfba0 Better handling of empty MQTT client id
If the configured client id is empty, the default value (auto generated) will be used
2024-06-29 11:05:04 +02:00
Thomas Basler
ba95f99e03 Feature: Allow custom MQTT Client ID 2024-06-29 00:28:21 +02:00
Bernhard Kirchen
6b19b877c6 power meter refactoring: split loop task init from init()
when performing a test request using the web UI, we need to init() the
respective power meter, but we do not want to start the polling task.
hence we move initialization of the polling task to the poll() function.
it will return if the task is setup already, otherwise setup the task.
2024-06-27 22:18:41 +02:00
Bernhard Kirchen
6b09ca056e Feature: SML power meters: reset SML decoder
implement a function which allows to reset the SML decoder. this new
function is used after a datagram ends. for the SML HTTP power meter
this is simple: after all bytes from the request's answer have been
decoded, we reset the decoder. for the SML serial power meter, we
perform the reset after a datagram ended based on timing (no new bytes
have been received for a specific amount of time).
2024-06-27 22:18:41 +02:00
Bernhard Kirchen
ea454972b9 Feature: SML power meter: handle checksum error
cache the values decoded in the SML datagram and only copy them to the
local stash of values if the checksum of the SML datagram matched. also
makes sure that values from incomplete SML datagrams are not used.

moreover, we now only publish values to the MQTT broker that we actually
decoded (successfully) from an SML datagram (we previously published 0.0
as values to topics we never decoded a value for).
2024-06-27 22:18:41 +02:00
Bernhard Kirchen
a1138a2202 Feature: Serial SML power meter: poll asynchronously 2024-06-27 22:18:41 +02:00
Bernhard Kirchen
fb7b710cb7 SML power meter: improve message output
* when printing a message, tell the name of the derived class.
* print total power only when state SML_FINAL reached.
* tell if a checksum verification error occurred.
2024-06-27 22:18:41 +02:00
Bernhard Kirchen
6c06e71fd0 Feature: SDM power meter: switch to software serial
a 9600 baud serial interface does not need a hardware UART. these
changes switch the SDM power meter implementation to use a software
serial instance instead. this is desirable as hardware UARTs are scarce
and users need them for JK BMS and VE.Direct interfaces.
2024-06-27 22:18:41 +02:00
Bernhard Kirchen
a5ba24fdd8 SDM power meter: check stop flag in between transactions
the destructor will block for way too long if we keep holding the
polling mutex while performing a transcation with the SDM power meter.
when reading, we now release the lock. afterwards, i.e., in between
transactions, we check the stop flag so the task terminates in a timely
manner once asked to do so.
2024-06-27 22:18:41 +02:00
Bernhard Kirchen
40423b0e07 SDM power meter: evaluate error code after polling value 2024-06-27 22:18:41 +02:00
Bernhard Kirchen
24f701020c SDM 1-phase power meter: only publish known values
a 1-phase SDM power meter does not know about power or voltage of phase
2 or 3. do not publish values to the respective MQTT topics when using a
single phase SDM power meter.
2024-06-27 22:18:41 +02:00
Bernhard Kirchen
4ad8e88e77 fix: SDM power meter: free HW serial port 2024-06-27 22:18:41 +02:00
Bernhard Kirchen
db869a1144 powermeter refactor: use HTTP1.0
avoid problems with chunked transfer encoding when using the client's
stream to parse a JSON document. fixes the HTTP+JSON power meter to work
with shelly and hichi (Tasmota).
2024-06-27 22:18:41 +02:00
Bernhard Kirchen
15b6a32b92 Feature: support JSON payload in MQTT power meter
the MQTT power meter can now process the messages published at the
respective topics as JSON and extract a power value using a JSON path
(same as in HTTP+JSON power meter). additionally, selecting a unit for
the power value as well as an option to invert the value's sign was
added as well, similar to the HTTPS+JSON power meter.
2024-06-27 22:18:41 +02:00
Bernhard Kirchen
347dd67684 Feature: SDM power meter: poll asynchronously 2024-06-27 22:18:41 +02:00
Bernhard Kirchen
8a46ba9541 Feature: HTTP+JSON power meter: poll asynchronously 2024-06-27 22:18:41 +02:00
Bernhard Kirchen
f6f62a604d Feature: HTTP+SML power meter: poll asynchronously 2024-06-27 22:18:41 +02:00
Bernhard Kirchen
a2a9debd02 Feature: make power meter polling intervals configurable
this change makes the respective setting accessible from the web UI.
2024-06-27 22:18:41 +02:00
Bernhard Kirchen
b891a4c1a3 powermeter refactor: instanciate power meters with config
instead of reading the main config's powermeter struct(s), the
individual power meters now are instanciated using a copy of their
respective config. this allows to instanciate different power meters
with different configs. as a first step, this simplifies instanciating
power meters for test purposes.
2024-06-27 22:18:41 +02:00
Bernhard Kirchen
3f2d9d38fa powermeter refactor: fully structure settings per provider
all power meter providers now have their own configuration struct
defined. a respective method to serialize and deserialize the provider
config is implemented for each provider.
2024-06-27 22:18:41 +02:00
Bernhard Kirchen
e1778eba76 powermeter refactor: use HttpGetter in HTTP SML implementation 2024-06-27 22:18:41 +02:00
Bernhard Kirchen
a08ef4cb43 powermeter refactor: test HTTP+JSON power meter as a whole
apply all config values from the webfrontend, then perform one polling
cycle. display values seperately in the result, and show the resulting
value as well.
2024-06-27 22:18:41 +02:00
Bernhard Kirchen
20ecf2a66b powermeter refactor: add and use HttpGetter class
this new class uses the newly introduced HttpRequestConfig and performs
HTTP requests using this config. it will be reused for other power
meters (SML over HTTP(S)) and may be reused by other features in the
future (battery provider, solar power provider, etc.).
2024-06-27 22:18:41 +02:00
Bernhard Kirchen
6da90de765 remove extraction of basic auth params from URL
the extractUrlComponents method did extract username and password
from the URL and encoded it for basic authentication. however, the
respective result string was never used. we only perform basic
authentication if the auth type is "basic" and if username and
password were supplied through the respective inputs.
2024-06-26 21:25:08 +02:00
Bernhard Kirchen
297b149f84 powermeter refactor: generalize HTTP request config
the parameters to peform an HTTP request by the HTTP(S)+JSON power meter
have been generalized by introducing a new config struct. this is now
used for all values which the HTTP(S)+JSON power meter can retrieve, and
also used by the HTTP+SML power meter implementation. we anticipate that
other feature will use this config as well.

generalizing also allows to share serialization and deserialization
methods in the configuration handler and the web API handler, leading to
de-duplication of code and reduced flash memory usage.

a new web UI component is implemented to manage a set of HTTP request
settings.
2024-06-26 21:25:08 +02:00
Bernhard Kirchen
ccba7d8036 move JSON path resolver to Utils class for re-use 2024-06-26 21:25:05 +02:00
Bernhard Kirchen
673b9f4fa8 powermeter refactor: use destructors to de-initialize 2024-06-26 20:51:56 +02:00
Bernhard Kirchen
e78f5849c1 Feature: decode more OBIS values in SML power meters
supersedes #951.
2024-06-26 20:51:56 +02:00
Bernhard Kirchen
75c07c17f2 powermeter refactor: SML lib: replace double by float
avoid additional conversions and avoid double for the fact that
calculations on type double are implemented in software, whereas
float is handled in hardware on ESP32.
2024-06-26 20:51:56 +02:00
Bernhard Kirchen
6108d24795 powermeter refactor: introduce PowerMeterSml
this new class handles SML data. it uses the SML lib to decode values
and manages those. this de-duplicates code as the class is applicable
to all power meters that collect SML data.
2024-06-26 20:51:56 +02:00
Bernhard Kirchen
6e44a6d750 powermeter refactor: allow destruction of httpClient
make sure the wifiClient used by the httpClient lives longer than the
httpClient, as it accesses the pointer to the wifiClient in its
destructor.
2024-06-26 20:51:56 +02:00
Bernhard Kirchen
54c04aed61 SDM power meter: remove baud rate setting
this setting was not used. the baud rate for the SDM is set to 9600 in
the source code. until the baud rate being customizable is actually
required by somebody, we remove the setting altogether.
2024-06-26 20:51:56 +02:00
Bernhard Kirchen
d99cfd5b31 powermeter refactor: publish values to MQTT in base class
"powertotal" is always published and it is published by the base class
directly. other values are still published by the derived classes, but
use a base class method, which takes care that a common base topic is
used in particular.
2024-06-26 20:51:56 +02:00
Bernhard Kirchen
d4c07836d9 MQTT powermeter: avoid iterating subscriptions
instead of iterating a map with subscriptions, we now bind the target
variable to the callback, which is executed once a message is arrived.
this way, the target variable is already linked to the respective topic
when the callback is executed.

lock the mutex when writing the variable, as the MQTT callback is
executed in a different context (MQTT task) than the main loop task,
which otherwise accesses the variables.
2024-06-26 20:51:56 +02:00
Bernhard Kirchen
5cd6334880 powermeter refactor: avoid reboot on settings change
the current power meter provider will be de-initialized, and a new
instance will be initialized with the new settings.
2024-06-26 20:51:56 +02:00
Bernhard Kirchen
33683d26c8 powermeter refactor: rename providers in enum
the enum values did not change, but their name (only relevant in the
code) are now more expressive.
2024-06-26 20:51:56 +02:00
Bernhard Kirchen
2397e5cdf5 powermeter refactor: split providers into their own classes
it is important to separate the capabilities of each power meter
provider into their own class/source file, as the providers work
fundamentally different and their implementations must not be
intermangled, which made maintenance and improvements a nightmare
in the past.
2024-06-26 20:51:54 +02:00
Marvin Carstensen
8ec1695d1b Feature: support Tibber bridge as power meter interface 2024-06-26 20:50:50 +02:00
Bernhard Kirchen
83c59d7811 convert files with CRLF endings to LF endings
this only changes line endings. inspect this commit with command `git
show <commit-sha> --ignore-space-at-eol` and it will tell you that the
commit appears to be "empty" (since all changes are whitespace changes
near the end of a line, which are ignored in that git show command).

the files to be changed were found and updated using this command:
find lib src include webapp/src -type f | \
    xargs grep --binary-files=without-match --files-with-matches \
    $(printf '\r\n') | xargs dos2unix

the following files were restored afterwards, as they are using CRLF
line endings in the upstream as well:
 - lib/CMT2300a/cmt2300a_defs.h
 - lib/README
 - include/README
2024-06-24 21:57:12 +02:00
Andreas Böhm
79214d750f
refactor PylontechCanBattery to be more generic (#1064) 2024-06-23 19:42:04 +02:00
Bernhard Kirchen
f21f58c67d adjust MessageOutput for changes in espressif/arduino-esp32
the "serial console" over USB would be garbled badly after switching to
"platform = espressif32@6.7.0". this did not happen to the upstream
version of MessageOutput. we used Serial.flush(), which seemed to be
good in the respective context. however, the changes in

github.com/espressif/arduino-esp32/pull/9462

made flush() detrimental. we remove the use of flush(), as it seems not
to be required (in particular, the upstream project does not use it).
2024-06-21 16:57:17 +02:00
Bernhard Kirchen
034026f782 restore JK BMS dummy implementation
broke in be41e6b9. was unusable as the complete type of DummySerial has
to be available in the JK BMS controller header when defining the
unique_ptr managing the dummy instance. this problem is solved by moving
the whole dummy class into its own header.
2024-06-21 16:57:11 +02:00
Bernhard Kirchen
5e3a53d8d3 Merge upstream tag 'v24.6.10' into development 2024-06-21 16:45:41 +02:00
Andreas Böhm
83ac15405e
Feature: Implement DPL 'overscaling' to compensate shading (#956) 2024-06-20 13:32:29 +02:00
cerise21
ccbaf55808
Feature: Set/obtain DPL target power consumption via MQTT 2024-06-20 13:25:41 +02:00
cerise21
1f6fdb7fc0
Feature: Set/obtain DPL upper power limit via MQTT 2024-06-15 20:21:42 +02:00
Bernhard Kirchen
5a007e5352 fix: make SDM power meter use serial port manager
instead of hard-coding the use of hardware UART 2, the SDM power meter
instance now asks for a free hardware serial port to use and
instanciates the respective HardwareSerial object using said port.
2024-06-02 22:41:07 +02:00
Bernhard Kirchen
be41e6b906 refactor serial port manager: hand out UARTs FCFS
get rid of particular compile-time designations by UART index. just hand
out the next free index of hardware UARTs, or indicate that none is
available any more.

use names as keys to register and free UARTs.
2024-06-02 22:41:07 +02:00
Bernhard Kirchen
5a1c3af31f Feature: add support for a third Victron MPPT
only on ESP32-S3-USB. this fiddles with the available hardware UARTs to
make it possible to use a third Victron MPPT. if three MPPTs are defined
int the pin mapping, you will not be able to use the SmartShunt and JK
BMS battery interfaces.

note that using a second MPPT will also conflict with the SDM power
meter, and that conflict is not detected, yet.
2024-06-02 22:41:07 +02:00
Bernhard Kirchen
c22ae2bf8d Feature: show BMS FW and HW version (JK BMS, SmartShunt) 2024-06-01 11:23:22 +02:00
swingstate
561f4be6d6 Feature: SmartShunt: process midpoint voltage and deviation 2024-05-31 21:08:15 +02:00
Bernhard Kirchen
88314f93c2 Fix: properly format Victron MPPT firmware version 2024-05-31 20:16:29 +02:00
Thomas Basler
b27a476507 Fix: Apply inverter settings only once and not for each channel 2024-05-31 00:56:15 +02:00
Thomas Basler
35aa835891 Merge branch 'pr2022' into dev 2024-05-31 00:52:28 +02:00
Stefan Oberhumer
8e8c463849 NFC: Includes list: Remove unneeded PinMapping.h 2024-05-31 00:30:15 +02:00
Thomas Basler
6e607f7f67 Feature: Add option to clear eventlog at midnight 2024-05-31 00:07:28 +02:00
eu-gh
90eb25f503
Fix: Huawei PSU: enforce BatterySoC Limit < 100 in UI (#992) 2024-05-30 21:31:46 +02:00
ButterBetzi
27f264e99b feature: JK BMS: HA auto-discovery for battery temperatures 2024-05-30 21:21:14 +02:00