Commit Graph

20 Commits

Author SHA1 Message Date
Bernhard Kirchen
054a677575 DPL settings in web app: split metadata from config
users are manipulating the DPL using HTTP POST requests. often they are
requesting the current settings using HTTP GET on the respective route,
then change a particular settings, and send all the data back using HTTP
POST. if they failed to remove the metadata node from the JSON,
OpenDTU-OnBattery would not be able to process the JSON due to its size.
the web app does not submit the metadata.

to avoid problems, the metadata is now split from the configuration
data.
2024-03-23 22:13:50 +01:00
Bernhard Kirchen
13bc943dd5 Feature: Refactor/Simplify DPL settings
this changeset refactors the web application's DPL settings view. the
DPL settings can be complex, and they shall be presented in a way that
allows users to comprehend their meaning. irrelevant settings are now
hidden or displayed dynamically based on the influencing settings.

* group SoC thresholds into their own card

* hide battery SoC thresholds if battery disabled. if the user did not
  even enable the battery interface, battery SoC values will not be used
  for DPL decisions. in that case we completely hide the respective
  settings from the DPL admin view. this reduces the amount of settings
  for new users and especially users who don't even have a battery in
  their setup or have no BMS connected.

* group voltage thresholds and improve label texts

* fix load correction factor unit

* fix header (wording)

* group solar-passthrough settings in new card

* group inverter-related settings

* hide solar passthrough settings if VE.Direct is disabled. closes #662.

* completely disable form if any requirement is not met

* list available inverters by name and type. this makes it much more
  convenient to select the right inverter, especially since the order of
  the inverters in the web UI is decoupled from their position in the
  internal array, which was used to select them previously. care was
  taken that old configs select the same inverter after an update.
  when editing the DPL settings, the selects an inverter from the newly
  created drow-down list, and the respective old inverter is
  pre-selected.

* disable form if no inverter is configured (config alert)

* make inverter input selection dynamic. adjust selection to actual
  amount of channels for selected inverter. skip selection altogether if
  inverter has only one channel, or if it is solar powered.

* web app: wording adjustments

* group meta data into new property and exclude from submission. saves
  memory when evaluating the submitted settings.

* hide irrelevant settings if inverter is solar-powered

* move restart hour setting to inverter card. translate setting which
  disabled automatic restart.

* simplify "drain strategy" setting into an on/off toggle. care was
  taken that existing configs work the same after an upgrade. the
  respective drain strategy is translated into the new setting when
  reading the config. once the config is written, the new setting is
  persisted and the old is not part of the config any more.

* show more configuration hints, depending on actual configuration

* replace inputs by InputElement components where possible
2024-03-17 16:50:57 +01:00
Bernhard Kirchen
c6f81806d6 DPL: make "IsInverterSolarPowered" configurable through web app 2024-03-09 15:40:13 +01:00
Bernhard Kirchen
921302bf73 Feature: DPL: add switch allowing to ignore SoC
unfortunately, the battery SoC values reported by battery BMSs are
unreliable, at least for some users, or at least without regular
(manual) full charge cycles to calibrate the BMS. it offers great
advantages to connect OpenDTU-OnBattery to a BMS (MQTT publishing of
values, Home Assistent integration, etc.), but previously the users
were then forced to configure the DPL by SoC values.

this change allows to configure the DPL such that SoC values are
ignored. instead, the voltage limits are used to make DPL decisions, as
if no SoC was available in the first place.

the SoC related setting are hidden from the DPL settings view if SoC
values are configured to be ignored.

closes #654.
2024-02-18 21:46:42 +01:00
Bernhard Kirchen
bb34fa74fd
Fix: use FormFooter in OnBattery-specific forms (#569)
the upstream project introduced a new Vue component "FormFooter", which
is used to end an input form, namely all settings forms. we should not
only use this component as well, but the save button on our forms
actually broke since the text dtuadmin.Save is replaced by base.Save.

also replace the use of dtuadmin.Seconds with base.Seconds, such that an
upstream change to dtuadmin.Seconds will not break the battery admin an
AC charger views.
2023-12-30 16:46:16 +01:00
Bernhard Kirchen
f0def2ae89
Selective verbosity (#318)
* DPL: implement verbose logging switch

* MQTT: implement verbose logging switch

* power meter: implement verbose logging switch

* Hoymiles lib: implement verbose logging switch

* cpp linting: "final" makes "virtual" and "override" redundant

... however, using only "final" is not as verbose.
2023-07-18 09:57:03 +02:00
Bernhard Kirchen
f3297930b5
DPL: account for solar passthrough losses (#307)
* fix another fixable "passtrough" typo

the typo in the config's identifier is not changed to preserve
compatibility while not spending the effort to migrate the setting.

* webapp language: prefer SoC over SOC

* DPL: implement solar passthrough loss factor

in (full) solar passthrough mode, the inverter output power is coupled
to the charge controler output power. the inverter efficiency is already
accounted for. however, the battery might still be slowly discharged for
two reasons: (1) line losses are not accounted for and (2) the inverter
outputs a little bit more than permitted by the power limit.

this is undesirable since the battery is significantly drained if solar
passthrough is active for a longer period of time. also, when using full
solar passthrough and a battery communication interface, the SoC will
slowly degrade to a value below the threshold value for full solar
passthrough. this makes the system switch from charging the battery
(potentially rapidly) to discharging the battery slowly. this switch
might happen in rather fast succession. that's effectively
trickle-charging the battery.

instead, this new factor helps to account for line losses between the
solar charge controller and the inverter, such that the battery is
actually not involved in solar passthrough. the value can be increased
until it is observed that the battery is not discharging when solar
passthrough is active.
2023-07-12 13:20:37 +02:00
helgeerbe
ffa9be0835 fix: #294 Passthrough Spelling 2023-07-07 17:05:44 +02:00
helgeerbe
6ed3ce7417 Fix: #274
Iverter is behind power meter - switch does not work
2023-06-26 12:27:26 +02:00
MalteSchm
e0a8da84d7 full solar passthrough 2023-06-09 13:09:58 +02:00
Martin Dummer
c727e21a49
Feature: add daily restart for the inverter
Add a configurable restart option for the inverter to set the "YieldDay"
values to zero.

Signed-off-by: Martin Dummer <martin.dummer@gmx.net>
2023-06-04 09:14:42 +02:00
helgeerbe
6a9585cd1e Fix: Power Limiter Settings / cannot set permitted current below zero helgeerbe/OpenDTU-OnBattery#171 2023-04-19 14:19:26 +02:00
Adminius
05a5b2367b PowerMeter Class + SDM PowerMeter support 2023-03-21 23:46:54 +01:00
helgeerbe
46ce6ad50f Implement battery drain strategies:
- empty when full
- empty at night
2023-03-16 17:48:22 +01:00
helgeerbe
17dd9db946 set min target power consumption to 0 2023-02-25 20:17:25 +01:00
helgeerbe
43815f6711 power limiter make fields mandtory 2023-02-25 17:25:02 +01:00
helgeerbe
28b24d01ad implement UI for target power consumption 2023-02-24 16:13:32 +01:00
helgeerbe
10f907477d fix name for inverter id and channel id 2023-02-23 22:41:37 +01:00
helgeerbe
56151b0d12 make inverter and channel selectable 2023-02-23 21:46:59 +01:00
helgeerbe
f560f25302 initial merge of power_limiter * missing is inverter and channel setting in gui
* due to bug _webApiPrometheus.init is commented out
2023-02-20 15:56:02 +01:00