Commit Graph

330 Commits

Author SHA1 Message Date
helgeerbe
0085970567 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-11-16 09:20:08 +01:00
MalteSchm
3dceddfe49
Split Huawei setValue in private/public implementation. Prevent setting values when internal power control mode is enabled (#521) 2023-11-15 12:38:35 +01:00
Thomas Basler
89b4b8ea85 Merge branch 'pr1441' into dev 2023-10-31 19:30:56 +01:00
CommanderRedYT
7c875187a8
Implemented mDNS 2023-10-30 20:53:45 +01:00
Bernhard Kirchen
0fa2745ace
Fix: VE.Direct refactor issues from #505 (#516)
* VE.Direct: return non-nullptr as a fallback

the changed return statement was supposed to return a shared_ptr to a
new and valid MPPT data struct as a fallback. however, it did return a
new shared_ptr that was initialized to nullptr.

* VE.Direct: make liveview total use total MPPT values

this change makes the call to VictronMppt.getData() obsolete, which in
turn will therefore not cause an error message on the console if
VE.Direct (MPPT) is not enabled. this change also takes care that once
multiple VE.Direct MPPT charge controllers are supported, the sums of
the respective total values are used in the web app totals.
2023-10-23 13:23:06 +02:00
Philipp Sandhaus
8ba9048f99
Show battery temperature when sensor is present (#511) 2023-10-23 13:22:10 +02:00
Bernhard Kirchen
4d4aadf8de
Feature: AC charger: configurable CAN controller frequency (#500) 2023-10-19 16:16:01 +02:00
Bernhard Kirchen
d23b991f5c
VE.Direct: Fix design issues and prepare support for multiple instances (#505)
* introduce VictronMpptClass

this solves a design issue where the loop() method of a static instance
of VeDirectMpptController, which is part of library code, is called as
part of the main loop() implementation. that is a problem because the
call to this loop() must be handled differently from all other calls:
the lib does not know whether or not the feature is enabled at all.
also, the instance would not be initialized when enabling the feature
during normal operation. that would even lead to a nullptr exception
since the pointer to the serial implementation is still uninitialized.

this new intermediate class is implemented with the support for multiple
Victron charge controllers in mind. adding support for more charge
controllers should be more viable than ever.

fixes #481.

related to #397 #129.

* VE.Direct: move get.*AsString methods to respective structs

those structs, which hold the data to be translated into strings, know
best how to translate them. this change also simplifies access to those
translation, as no parameter must be handed to the respective methods:
they now act upon the data of the instance they are called for. adds
constness to those methods.

* VE.Direct: simplify and clean up get.*AsString methods

use a map, which is much easier to maintain and which reads much easier.
move the strings to flash memory to save RAM.

* DPL: use VictronMpptClass::getPowerOutputWatts method

remove redundant calculation of output power from DPL. consider
separation of concern: VictronMpptClass will provide the total solar
output power. the DPL shall not concern itself about how that value is
calculated and it certainly should be unaware about how many MPPT charge
controllers there actually are.

* VE.Direct: avoid shadowing struct member "P"

P was part of the base struct for both MPPT and SmartShunt controller.
however, P was also part of the SmartShunt controller data struct,
shadowing the member in the base struct.

since P has slightly different meaning in MPPT versus SmartShunt, and
since P is calculated for MPPT controllers but read from SmartShunts, P
now lives in both derived structs, but not in the base struct.

* VE.Direct: isDataValid(): avoid copying data structs

pass a const reference to the base class implementation of isDataValid()
rather than a copy of the whole struct.

* VE.Direct: unify logging of text events

* VE.Direct: stop processing text event if handled by base

in case the base class processed a text event, do not try to match it
against values that are only valid in the derived class -- none will
match.

* VE.Direct MPPT: manage data in a shared_ptr

instead of handing out a reference to a struct which is part of a class
instance that may disappear, e.g., on a config change, we now manage the
lifetime of said data structure using a shared_ptr and hand out copies
of that shared_ptr. this makes sure that users have a valid copy of the
data as long as they hold the shared_ptr.

* VE.Direct MPPT: implement getDataAgeMillis()

this works even if millis() wraps around.

* VE.Direct: process frame end event only for valid frames

save a parameters, save a level of indention, save a function call for
invalid frames.
2023-10-19 16:15:29 +02:00
Bernhard Kirchen
116da05114
DPL: (re-)send power limits periodically (#483)
avoid staleness in case the same power limit is calculated over and over
again, hence no new power limit value is calculated and hence no power
limit command is sent to the inverter. staleness occurs in this case if
the first power limit command to establish the respective limit was not
received by the inverter. one can easily simulate a situation where the
same power limit is caluclated over and over again: with a battery above
the start threshold, set a very low upper power limit for the inverter
(DPL setting). that value will be used as the limit as long as the power
meter reading is larger than that.

we could also check the limit reported by the inverter. however, that
value is in percent of the inverter's max AC output, and is often not
the same value as we requested as the limit, but slightly off. we then
would have to decide how much deviation is okay, which is unreasonably
complicated.

closes #478.
2023-10-09 09:51:40 +02:00
Stefan Oberhumer
7f99095fca Remove SUNPOS_UPDATE_INTERVAL define and introduce INVERTER_UPDATE_SETTINGS_INTERVAL. 2023-10-06 11:13:09 +02:00
Stefan Oberhumer
943dfc2dbf Compute sunrise and sunset only if necessary.
Sunrise and -set must recomputed if one of the following conditions is met:
* The date changed (based on the selected timezone)
* Location (Lat/Lon) changed
* Sunset type changed

So instead of calculating that every minute just do it on update via web interface or date change.

If a new config is uploaded, the DTU gets restarted. There is no need to initiate a recalculation in this case.
2023-10-06 10:20:36 +02:00
MalteSchm
b1164d6c69
Move Huawei CAN bus communication to separate thread (#454) 2023-10-02 11:22:10 +02:00
Philipp Sandhaus
7142921021
Integration of Victron SmartShunt via VE.Direct (#452)
* Move Mppt logic to subclass

* Added Definitions for Shunts and restructering

* First integration of SmartShunt data into Web Interface

* Code cleanup

* VE.Direct: whitespace cleanup

* VE.Direct: manage HardwareSerial in unique_ptr

* VE.Direct: _efficiency is only needed by MPPT

* VE.Direct: keep as many members private as possible

* VE.Direct: use int8_t for pins (as before)

* VictronSmartShunt: _verboseLogging is not used

* VE.Direct: OR (off reason) is MPPT specific

it also applies to Phoenix inverters and Smart BuckBoost, but since
there is no support for those, the code is moved to the MPPT controller.

* Added Shunt alarms to liveview
Changed from double to int for several readings

* Update build.yml to allow manual builds

---------

Co-authored-by: Philipp Sandhaus <philipp.sandhaus@cewe.de>
Co-authored-by: Bernhard Kirchen <schlimmchen@posteo.net>
2023-09-22 17:24:57 +02:00
helgeerbe
b081845b95 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-09-19 12:28:00 +02:00
Thomas Basler
35da310420 Initialize variables before first usage 2023-09-18 20:23:00 +02:00
helgeerbe
ed2a189a61 Merge branch 'helgeerbe/issue438' into development 2023-09-18 17:56:58 +02:00
helgeerbe
f2893220a5 fix: #438 2023-09-18 17:56:22 +02:00
helgeerbe
9d6b459dc6 merge of v23.9.13 2023-09-18 10:46:43 +02:00
Bernhard Kirchen
954a98dbc8 JK BMS: Support for MQTT (#432)
* JK BMS: avoid trailing whitespace in debug output

* JK BMS: publish data points through MQTT

* JK BMS: updateFrom: skip data points with equal value

this changes the interpretation of the timestamp in data containers that
are merely updated from other data containers: this is the oldest
timestamp known where the value was as recorded by the data point in its
respective container.

the data container constructed from an answer will -- naturally -- have
the timetamps of its data points set to the time they were constructed.

* JK BMS: only publish changed values to MQTT broker

all values are still published once every minute if the MQTT retain flag
is NOT set. otherwise, the constant values are only published once on
startup.
2023-09-15 10:06:30 +02:00
helgeerbe
f7bd4a40d8 revert Revert "Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development"
merge of v23.9.11 broke the system. As a workaround upgrade espressif32 from 6.3.2 to 6.4.0 is skipped. See #440
2023-09-14 13:45:23 +02:00
Thomas Basler
a974e217df Fix #1335: Only the first inverter was set to zero at midnight via mqtt 2023-09-13 18:46:23 +02:00
Bernhard Kirchen
24018a1432
JK BMS: Support for MQTT (#432)
* JK BMS: avoid trailing whitespace in debug output

* JK BMS: publish data points through MQTT

* JK BMS: updateFrom: skip data points with equal value

this changes the interpretation of the timestamp in data containers that
are merely updated from other data containers: this is the oldest
timestamp known where the value was as recorded by the data point in its
respective container.

the data container constructed from an answer will -- naturally -- have
the timetamps of its data points set to the time they were constructed.

* JK BMS: only publish changed values to MQTT broker

all values are still published once every minute if the MQTT retain flag
is NOT set. otherwise, the constant values are only published once on
startup.
2023-09-13 12:14:29 +02:00
helgeerbe
2eeb5f1d19 Revert "Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development"
This reverts commit eb1c2dbd8c, reversing
changes made to 0cb42a6424.

merge of v23.9.11 broke the system
2023-09-12 20:18:10 +02:00
helgeerbe
a7ea15cde9 add missing Arduino.h 2023-09-12 19:43:30 +02:00
helgeerbe
eb1c2dbd8c Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-09-12 19:27:32 +02:00
Thomas Basler
9ac6dd6e8d Feature: First very basic support to read the grid profile
The parser is still missing and requires community support to collect data.
2023-09-07 22:08:07 +02:00
Thomas Basler
ec9af886d5 Feature: Added option to set daily yield to zero at midnight 2023-09-05 20:27:52 +02:00
Thomas Basler
7d90937d0f Publish mqtt string stats values periodically if they are set to zero if unreachable 2023-09-04 18:20:51 +02:00
Bernhard Kirchen
68783b450f
Messages: thread-safety and dynamic memory (#418)
* thread-safety and dynamic memory for MessageOutput

* use dynamic memory to allow handling of arbitrary message lenghts.
* keep a message buffer for every task so no task ever mangles the
  message of another task.
* every complete line is written to the serial console and moved to
  a line buffer for sending them through the websocket.
* the websocket is always fed complete lines.
* make sure to feed only as many lines as possible to the websocket
  handler, so that no lines are dropped.
* lock all MessageOutput state against concurrent access.

* MessageOutput: respect HardwareSerial buffer size

the MessageOutput class buffers whole lines of output printed by any
task in order to avoid mangling of text. that means we hand over full
lines to the HardwareSerial instance, which might be too much in one
call to write(buffer, size). we now check the return value of
write(buffer, size) and call the function again with the part of the
message that could not yet be written by HardwareSerial.
2023-09-04 14:08:30 +02:00
Bernhard Kirchen
ba303da742
VE.Direct: Reset state machine on timeout, fix and extend logging (#416)
* VE.Direct: reset state machine on timeout

there will never be a large gap between two bytes of the same frame.
if such a large gap is observed, reset the state machine so it tries
to decode a new frame once more data arrives.

this is helpful in case of corrupted data that prevents the state
machine of transitioning to the final state even though the VE.Direct
data producer is done sending bytes that belong to the same frame.

* VE.Direct: print problems to MessageOutput

this includes the web console in particular, where many users have
access to while the serial console is not attached or monitored.

* VE.Direct: collect serial input into buffer and print

should help debug issues for users.

* VE.Direct: implement and use verbose logging switch
2023-09-04 14:07:48 +02:00
Martin
a7a38e74a1
Feature: add nice Icons for HA autoconfiguration (#413)
* add Icons for Battery and Victron device sensors in Home Assistant
  overriding the boring default icon for many sensors

Signed-off-by: Martin Dummer <martin.dummer@gmx.net>
2023-09-04 14:07:24 +02:00
Thomas Basler
abf95634db Replace platform dependent variable types by platform independent 2023-09-03 23:27:53 +02:00
Thomas Basler
6127fbe940 Feature: Added option to set runtime values to zero when inverter becames unreachable 2023-09-02 12:22:22 +02:00
Thomas Basler
b34b22c658 Fix: Workaround: Don't allow memory intensive web functions in parallel
Somehow the API has to be adjusted to reduce memory consumption. For now lets just prevent both methods to allocate memory at the same time.
2023-09-02 01:41:53 +02:00
Thomas Basler
2c41be106e Feature: Allow setting of the Reachable Threshold per inverter 2023-09-01 19:17:12 +02:00
Thomas Basler
c5f9f460cd Feature: Added config option to change MQTT CleanSession Flag 2023-09-01 18:03:30 +02:00
Bernhard Kirchen
f744629b0b
Support for Jikong JK BMS using serial connection (#319) 2023-08-31 16:21:32 +02:00
helgeerbe
d4afc5940a Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-08-29 09:24:25 +02:00
Bernhard Kirchen
96ee78156d
Fix DPL Mode 2 MQTT Status (#402)
* DPL MQTT handler: modernize

* there is no need to tokenize and check the topic of a received MQTT
  message if we only subscribe to a single topic. all messages will be
  for that topic. avoid testing the topic in the callback alltogether.
* use std::string and std::stoi over allocating and deleting a buffer
  and copying charactes around.
* use a switch statement to process the actual payload.
* break a long line.

* DPL: fix getMode() return value

getMode() returned a bool. probably its return type was not adjusted
when the third mode was introduced. this lead to mode 2 being cast to
true implicitly, which in turn was used to construct a String, such that
"1" was published as the DPL mode when in fact it was 2.

make the mode an enum class to avoid such problems in the future.

inline getMode() and setMode().

fix indention.
2023-08-28 13:20:56 +02:00
helgeerbe
ca308d0895 Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-08-28 13:12:07 +02:00
Thomas Basler
701c490654 Feature: Turn off Display before reboot
Thanks for the idea to @StefanOberhumer
This prevents always on Display if the device profile does not contain Display pins anymore after the reboot
2023-08-25 16:57:24 +02:00
Thomas Basler
c91bd42a77 Feature: Turn off LEDs before reboot
Thanks for the idea to @StefanOberhumer
This prevents always on LEDs if the device profile does not contain LEDs pins anymore after the reboot
2023-08-25 13:15:55 +02:00
Thomas Basler
77a90095d9 Move different restart calls into one method 2023-08-25 12:58:53 +02:00
Thomas Basler
6429d64062 Prometheus Endpoint: Simplify code by looping over fields instead of duplicated code 2023-08-22 13:00:52 +02:00
Bernhard Kirchen
7c7a15e016
VE.Direct: websocket and status API response size (#371)
the size allocated for the HTTP request response was too little, while
the size for the buffer of the websocket output was increased already.

add a new member variable and use it in both context, such that
increasing the buffer size to accomodate more space (for the JSON data
in particular) will benefit both contexts in the future.
2023-08-10 13:40:09 +02:00
helgeerbe
21bbed9b8e Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-08-09 12:37:33 +02:00
Bernhard Kirchen
e6eaa001e7
DPL: use testThreshold() in useFullSolarPassthrough() (#357) 2023-08-06 17:00:27 +02:00
Thomas Basler
9179b672f5 Use lock_guard to simplify code 2023-08-05 01:25:53 +02:00
Bernhard Kirchen
aff7924411
Inhibit solar passthrough while battery below stop threshold (#354)
* DPL: improve verbose logging

* shorten DPL log prefix
* canUseDirectSolarPower() was printed two times
* _batteryDischargeEnabled was printed two times
* convert boolean values to human-readable strings
* add units where possible
* split messages into block "before calculating new limit" and "after
  calculating new limit", as the latter cannot rely on _inverter being
  available.
* order messages such that variables whose value is derived from other
  variables are printed later than their dependencies.
* merge output into blocks (one instance near "Printout some stats")
* remove more redundant info (produced in functions outside loop())
* print target grid consumption

* DPL: inhibit solar passthrough while stop threshold reached

* DPL: implement and use isBelowStopThreshold()

we only want to inhibit solar passthrough if the SoC is *below* the stop
threshold, not if it is equal to the stop threshold. otherwise, when
discharging, we would discharge until the battery reached the stop
threshold, then we would also inhibit solar passthrough, until the
battery is charged to the SoC stop threshold plus one percent.
2023-08-04 12:35:37 +02:00
helgeerbe
5335ec1bde Merge remote-tracking branch 'tbnobody/OpenDTU/master' into development 2023-08-04 12:21:16 +02:00