@ -12,6 +12,20 @@ The base topic, as configured in the web GUI is prepended to all follwing topics
|
|||||||
| dtu/status | R | Indicates whether OpenDTU network is reachable | online / offline |
|
| dtu/status | R | Indicates whether OpenDTU network is reachable | online / offline |
|
||||||
| dtu/uptime | R | Time in seconds since startup | seconds |
|
| dtu/uptime | R | Time in seconds since startup | seconds |
|
||||||
|
|
||||||
|
## Inverter total topicss
|
||||||
|
|
||||||
|
Enabled inverter means, that only inverters with "Poll inverter data" enabled are considered.
|
||||||
|
|
||||||
|
| Topic | R / W | Description | Value / Unit |
|
||||||
|
| --------------------------------------- | ----- | ---------------------------------------------------- | -------------------------- |
|
||||||
|
| ac/power | R | Sum of AC active power of all enabled inverters | W |
|
||||||
|
| ac/yieldtotal | R | Sum of energy converted to AC since reset watt hours of all enabled inverters | Kilo watt hours (kWh) |
|
||||||
|
| ac/yieldday | R | Sum of energy converted to AC per day in watt hours of all enabled inverters | Watt hours (Wh)
|
||||||
|
| ac/is_valid | R | Indicator whether all enabled inverters where reachable | 0 or 1 |
|
||||||
|
| dc/power | R | Sum of DC power of all enabled inverters | Watt (W) |
|
||||||
|
| dc/irradiation | R | Produced power of all enabled inverter stripes with defined irradiation settings divided by sum of all enabled inverters irradiation | % |
|
||||||
|
| dc/is_valid | R | Indicator whether all enabled inverters where reachable | 0 or 1 |
|
||||||
|
|
||||||
## Inverter specific topics
|
## Inverter specific topics
|
||||||
|
|
||||||
serial will be replaced with the serial number of the inverter.
|